Operator’s Manual
XL, 5, 10
Oxygen Concentrators Standard,
with SensO2®and HomeFill™II
Invacare 5 with SensO |
2 |
Invacare 5 |
Model IRC5LXO2 |
|
Model IRC5LX |
Invacare 10 with SensO |
Invacare 10 |
|
|
2 |
|
Model IRC10LXO2 |
Model IRC10LX |
|
Dealer: This manual MUST be given to the end user.
User: Before using this product, read this manual and save for future reference.
For more information regarding Invacare products, parts, and services, please visit www.invacare.com
WARNING
WARNING
DO NOT OPERATE THIS EQUIPMENT WITHOUT FIRST READING AND UNDERSTANDING THIS MANUAL. IF YOU ARE UNABLE TO UNDERSTAND THE WARNINGS, CAUTIONS, AND INSTRUCTIONS, CONTACT INVACARE TECHNICAL SERVICES BEFORE ATTEMPTING TO USE THIS EQUIPMENT - OTHERWISE SERIOUS INJURY OR PROPERTY DAMAGE MAY RESULT.
There are many different types of humidifiers, oxygen tubing, cannulas and masks that can be used with this device. You should contact your local home care provider for recommendations on which of these devices will be best for you. They should also give you advice on the proper usage, maintenance, and cleaning.
WARNING
Platinum™Series |
2 |
Part No 1118353 |
TABLE OF CONTENTS |
|
ACCESSORIES .................................................. |
2 |
SPECIAL NOTES ............................................... |
5 |
SECTION 1—GENERAL GUIDELINES .................. |
6 |
Maintenance.......................................................................................... |
8 |
Radio Frequency Interference.......................................................... |
8 |
To Reduce The Risk Of Burns, Electrocution, Fire Or |
|
Injury To Persons................................................................................ |
9 |
Polarized Plug Instruction................................................................ |
10 |
SECTION 2—FEATURES .................................. |
11 |
SECTION 3—HANDLING ................................. |
12 |
Unpacking............................................................................................ |
12 |
Inspection............................................................................................ |
12 |
Storage................................................................................................. |
12 |
SECTION 4—SPECIFICATIONS ......................... |
13 |
SECTION 5—OPERATING INSTRUCTIONS ....... |
23 |
Introduction........................................................................................ |
23 |
Select a Location ............................................................................... |
23 |
Recommended Guidelines for Optimum Performance............ |
24 |
Plug in Power Cord .......................................................................... |
24 |
Connect Humidifier (If So Prescribed)......................................... |
25 |
Power Switch ..................................................................................... |
27 |
Flowrate............................................................................................... |
28 |
SensO2 Oxygen Purity Indicator (If Your Unit Features |
|
the O2 Sensor Feature).................................................................... |
29 |
Initial Startup of the Concentrator ............................................... |
29 |
Explanation of Oxygen Purity Indicator Lights........................... |
29 |
Indicators (If Your Unit Does Not Feature the O2 Sensor) ... |
30 |
Part No 1118353 |
3 |
Platinum™Series |
TABLE OF CONTENTS |
|
SECTION 6—MAINTENANCE .......................... |
32 |
Routine Maintenance........................................................................ |
32 |
SECTION 7—TROUBLESHOOTING GUIDE ......... |
35 |
LIMITED WARRANTY .................................... |
38 |
Platinum™Series |
4 |
Part No 1118353 |
SPECIAL NOTES
SIGNAL WORD |
MEANING |
|
|
|
Danger indicates an imminently hazardous situation |
|
which, if not avoided, will result in death or serious |
DANGER |
injury. |
|
|
|
Warning indicates a potentially hazardous situation |
|
which, if not avoided, could result in death or seri- |
WARNING |
ous injury. |
|
|
|
Caution indicates a potentially hazardous situation |
|
which, if not avoided, may result in property dam- |
CAUTION |
age. |
|
|
|
|
DANGER
Users MUST not smoke while using this device. Keep all matches, lighted cigarettes or other sources of ignition out of the room in which this product is located. No smoking signs should be prominently displayed. Textiles and other materials that normally would not burn are easily ignited and burn with great intensity in oxygen enriched air. Failure to observe this warning can result in severe fire, property damage and cause physical injury or death.
Part No 1118353 |
5 |
Platinum™Series |
SECTION 1—GENERAL GUIDELINES
SECTION 1—GENERAL GUIDELINES
WARNING
SECTION 1 - GENERAL GUIDELINES contains important information for the safe operation and use of this product. DO NOT use this product or any available optional equipment without first completely reading and understanding these instructions and any additional instructional material such as Owner’s Manuals, Service Manuals or Instruction Sheets supplied with this product or optional equipment. If you are unable to understand the Warnings, Cautions or Instructions, contact a healthcare professional, dealer or technical personnel before attempting to use this equipment - otherwise, injury or damage may occur.
DANGER
Platinum™Series |
6 |
Part No 1118353 |
SECTION 1—GENERAL GUIDELINES
WARNING
The use of oxygen therapy requires that special care be taken to reduce the risk of fire. Any materials that will burn in air, and some that will not, are easily ignited and burn rapidly in high concentrations of oxygen. For safety concerns, it is necessary that all sources of ignition be kept away from the product and preferably out of the room in which it is being used. NO SMOKING signs should be prominently displayed.
A spontaneous and violent ignition may occur if oil, grease or greasy substances come in contact with oxygen under pressure. These substances MUST be kept away from the oxygen concentrator, tubing and connections, and all other oxygen equipment. DO NOT use any lubricants unless recommended by Invacare.
Part No 1118353 |
7 |
Platinum™Series |
SECTION 1—GENERAL GUIDELINES
WARNING
NEVER block the air openings of the product or place it on a soft surface, such as a bed or couch, where the air opening may be blocked. Keep the openings free from lint, hair and the like. Fill humidifier with water to the level shown by the manufacturer. DO NOT overfill.
The Invacare Oxygen Concentrator was specifically designed to minimize routine preventive maintenance. Only professionals of the healthcare field or persons fully conversant with this process such as factory trained personnel should perform preventive maintenance or performance adjustments on the oxygen concentrator.
Platinum™Series |
8 |
Part No 1118353 |
SECTION 1—GENERAL GUIDELINES
WARNING
To Reduce The Risk Of Burns,
Electrocution, Fire Or Injury To
Persons.
This device is to be used only in accordance with the prescription of a physician and this Owner’s Manual. If at any time the patient or attendant conclude that the patient is receiving an insufficient amount of oxygen, the supplier and/or physician should be contacted IMMEDIATELY.
Part No 1118353 |
9 |
Platinum™Series |
SECTION 1—GENERAL GUIDELINES
WARNING
As a safety feature, this appliance has a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT attempt to defeat this safety feature.
Platinum™Series |
10 |
Part No 1118353 |
SECTION 2—FEATURES
SECTION 2—FEATURES
|
|
Oxygen Purity Indicator Lights |
|
|
(SensO2 model only)/ Fault |
Oxygen Outlet |
and Power Indicator Lights |
|
|
|
(LX model only) |
Flowmeter |
|
Power Switch |
|
|
|
|
|
Circuit Breaker |
|
|
Elapsed Time Meter |
|
|
Cabinet Filter |
|
|
(one of two shown) |
|
|
ACCESSORIES (NOT SHOWN): |
|
|
Remote Humidifier/Flowmeter Accessory - |
|
|
IRCRF5 (Platinum 5 and XL Only) |
REAR VIEW |
PreciseRX™ Pediatric Humidifier/Flowmeter |
|
|
|
Accessory - IRCPF16 (Platinum 5 and XL Only) |
|
|
HomeFill II home oxygen compressor - |
|
|
IOH200 |
|
|
NOTE: This outlet fitting is to be used only |
|
|
for filling oxygen cylinders with the |
|
|
HomeFill II home oxygen compressor. The |
|
|
outlet fitting does not affect concentrator |
|
|
performance. Refer to the HomeFill II |
|
|
owner's manual, part number 1100873, for |
|
|
connection and operating instructions. |
Power |
Outlet |
When not in use, the plug provided with the |
Cord |
Fitting |
concentrator should be inserted into the |
|
|
outlet fitting. For more information about the |
|
|
HomeFill II, contact your Invacare dealer. |
Part No 1118353 |
11 |
Platinum™Series |
SECTION 3—HANDLING
SECTION 3—HANDLING
3.Carefully remove all the components from the
carton. |
FIGURE 3.1 Unpacking |
Platinum™Series |
12 |
Part No 1118353 |