THIS MANUAL MUST BE GIVEN TO THE USER OF
THE COMPRESSOR.
REFER TO THE INFORMATION ON PAGE 3 OF THIS
MANUAL.
USER:
BEFORE USING THE COMPRESSOR, READ THIS
MANUAL AND SAVE FOR FUTURE REFERENCE.
SPECIAL NOTES
SPECIAL NOTES
WARNING
DO NOT INSTALL, ASSEMBLE OR OPERATE THIS
EQUIPMENT WITHOUT FIRST READING AND
UNDERSTANDING THIS INSTRUCTION MANUAL,
THE CONCENTRATOR OWNERS MANUAL, AND
THE OXYGEN CYLINDER WARNING LABEL. IF
YOU ARE UNABLE TO UNDERSTAND THE
WARNINGS, CAUTIONS AND INSTRUCTIONS,
CONTACT A DEALER OR TECHNICAL PERSONNEL
IF APPLICABLE BEFORE ATTEMPTING TO INSTALL
THIS EQUIPMENT - OTHERWISE, INJURY OR
DAMAGE MAY OCCUR.
SPECIAL NOTES
Check all parts for shipping damage. In case of damage, DO NOT use. Contact
Invacare for further instruction.
WARNING/CAUTION notices used in this manual apply to hazards or unsafe
practices which could result in personal injury or property damage.
NOTICE
The Venture HomeFill II Compressor is for use with specially designed Invacare 5 liter HomeFill II compatible concentrators set at 3 L/min or less ONLY.
To determine if your Invacare 5 liter concentrator is HomeFill II compatible,
examine the lower right corner of the rear of the concentrator for an outlet
fitting, as shown below.
Concentrator
VENTURE
®
HOMEFILL II COMPRESSOR2
Outlet Fitting
CONTENTS/DEALER INFORMATION
TABLE OF CONTENTS
SPECIAL NOTES .............................................................................. 2
NOTE: Invacare recommends leaving a full cylinder of oxygen with the patient AFTER setting up the
HomeFill II compressor.
CHECKLIST
Before leaving a Venture HomeFill II Compressor with a user, the following checklist MUST be
completed:
❑ Make sure the pressure test on cylinder has not expired.
❑ Instruct the user on the safe operation of the concentrator and review ALL warnings.
❑ Instruct the user on the safe operation of the Venture HomeFill II compressor and review
ALL warnings.
❑ Leave a full cylinder of oxygen with the user.
❑ Leave a copy of ALL warnings and filling instructions with the user.
3VENTURE
®
HOMEFILL II COMPRESSOR
DEALER INFORMATION
SPECIFICATIONS/LABEL LOCATIONS
SPECIFICATIONS
Regulatory Listing:
Operating temperature:
Storage temperature:
SPECIFICATIONS
Input Pressure Required:
Input FLOW Required:
Input O2% Required:
Shipping Weight:
Double Insulated Product
ETL Certified Complying with UL1097 (US)
ETL Certified Complying with CAN/CSA C22.2 No. 68
(Canada)
COMPRESSOR SPECIFICATIONS
50 to 95° F (10 to 35° C) @ 20 to 60%
non-condensing humidity
-10 to 150° F (-23 to 65° C) @ 15 to 95% humidity
14 - 21 psi
2 L/min
This unit contains moving and high pressure
components. Manufacturer service only.
!
LABEL LOCATIONS
FRONTLEFT SIDE
WARNING
!
PART NO.
1075221
Keep all connections free of oil and grease to avoid
violent ignition. See Owner's Manual before cleaning.
PART NO.
1075220
WARNING
!
Keep all connections free of oil and grease.
See owners manual before cleaning.
Cylinders filled on this unit must be labeled "Contents
of this cylinder is the product of an oxygen concentrator."
VENTURE
®
HOMEFILL II COMPRESSOR4
PART NO.
1075238
GENERAL GUIDELINESPROCEDURE 1
This Procedure includes the following:
General Warnings
Handling Warnings
In order to ensure the safe installation, assembly and operation of the VENTURE
HOMEFILL II COMPRESSOR these instructions MUST be followed:
GENERAL WARNINGS
Caution: Federal law restricts this device to sale by or on order of a physician,
or any other practitioner licensed by the law of the State in which he/she
practices to use or order the use of this device.
The use of this device is limited to the oxygen patient. Cylinders MUST be used
ONLY by the oxygen patient and are not to be distributed to any other individual for any purpose.
DO NOT use parts, accessories or adapters other than those authorized by
Invacare or warranty will be voided.
NEVER block the air openings of the product or place it on a soft surface, such
as a bed or couch, where the air opening may be blocked. Keep the openings
free from lint, hair and the like.
DO NOT disassemble. There are minimal serviceable parts on the Venture
HomeFill II Compressor. If any service is required, contact Invacare technical
service.
If the compressor has a damaged cord or plug, if it is not working properly, if it
has been dropped or damaged, or submersed in water, call a qualified technician for examination and repair.
If any leakage of the oxygen cylinder is detected DO NOT attempt to use the
cylinder. Turn the flow selector knob on the regulator to 0. If leakage persists, place the cylinder outdoors and notify your Home Health Care Provider
or Service Representative of this condition.
DO NOT allow oil from your hands or other source to come into contact with
the regulator or cylinder valve connection. These solutions may be flammable
and cause injury.
The HomeFill II is equipped with a High Pressure Relief Valve to ensure the
users safety. When activated, this safety feature will make an extremely loud
noise. If this noise occurs, turn the unit OFF and contact your Home Health
Care Provider or Service Representative.
Before moving or repositioning either the compressor or concentrator, always
disconnect the AC power cords and the interconnect hose between the compressor and concentrator. Failure to do so may result in damage to the unit or
personal injury.
Children should always be supervised around the HomeFill unit. When used
with the HomeFill table or similar elevated support surfaces, a child could pull
over any such table causing the unit to fall. Failure to observe this warning
may result in personal injury or product damage.
GENERAL GUIDELINES
Use extreme care when handling and filling an oxygen cylinder. Full oxygen cylinders are under pressure and can become a projectile if dropped or mishandled.
NEVER transport a compressor with a cylinder connected to or stored on the
compressor, otherwise injury or damage can occur.
HANDLING WARNINGS
5VENTURE
®
HOMEFILL II COMPRESSOR
INITIAL SETUPPROCEDURE 2
This Procedure includes the following:
Compressor Initial Setup Checklist
Choosing a Location
Transporting the Compressor
Installing the Power Cord
Connecting the Compressor to the Concentrator
NOTE: DEALERS ONLY - Refer to DEALER INFORMATION on PAGE 3 of this manual BEFORE
performing this procedure.
INITIAL SETUP
COMPRESSOR INITIAL SETUP CHECKLIST
Before operating the HomeFill II Compressor for the first time, complete the following checklist:
❑ Choose a location for the compressor.
❑ Transport the compressor to the desired location.
❑ Connect the power cord to the compressor.
❑ Connect the compressor to the concentrator.
CHOOSING A LOCATION
The compressor should be at least three (3) inches away from walls, draperies or furniture to
ensure sufficient air flow.
Avoid placing the compressor next to heaters, radiators or hot air registers.
DO NOT use in a closet.
The compressor should sit on a hard flat stable surface, such as a table.
TRANSPORTING THE COMPRESSOR (FIGURE 1)
NEVER transport a compressor with a cylinder connected to or stored on the
compressor, otherwise injury or damage can occur.
When transporting the compressor, be careful not to bump the compressor or
the connectors into obstacles. Otherwise damage to the compressor may occur.
There are two (2) methods to safely transport
the compressor:
A. ONE HAND - Grasp the handle at the
bottom rear of the compressor.
B. TWO HANDS - Grasp the hand grips on
the sides of the compressor.
VENTURE
®
HOMEFILL II COMPRESSOR6
WARNING
CAUTION
Hand
Grip
FIGURE 1 - TRANSPORTING THE
Hand
Grip
Handle
COMPRESSOR
Loading...
+ 14 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.