PARTS MANUAL Gas Furnace F9MVT, G9MVT
Safety Labeling and Signal Words
DANGER, WARNING, CAUTION, and NOTE
The signal words DANGER, WARNING, CAUTION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER is only used on product labels to signify an immediate hazard. The signal words WARNING, CAUTION, and NOTE will be used on product labels and throughout this manual and other manuals that may apply to the product.
DANGER − Immediate hazards which will result in severe personal injury or death.
WARNING − Hazards or unsafe practices which could result in severe personal injury or death.
CAUTION − Hazards or unsafe practices which may result in minor personal injury or product or property damage.
NOTE − Used to highlight suggestions which will result in enhanced installation, reliability, or operation.
Signal Words in Manuals
The signal word WARNING is used throughout this manual in the following manner:
!WARNINGWARN G
The signal word CAUTION is used throughout this manual in the following manner:
!CAUTION
Signal Words on Product Labeling
Signal words are used in combination with colors and/or pictures on product labels.
TABLE OF CONTENTS
Model Number Identification . . . . . . . . . . . . . . . . . . . . . 2
Parts Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
3 |
Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . |
9 |
MODELS
F9MVT0401410A1 . . . . . . . . . . . . . G9MVT0401410A1 F9MVT0601714A1 . . . . . . . . . . . . . G9MVT0601714A1 F9MVT0801716A1 . . . . . . . . . . . . . G9MVT0801716A1 F9MVT0802120A1 . . . . . . . . . . . . . G9MVT0802120A1 F9MVT1002116A1 . . . . . . . . . . . . . . G9MVT1002116A1 F9MVT1002120A1 . . . . . . . . . . . . . G9MVT1002120A1 F9MVT1202422A1 . . . . . . . . . . . . . G9MVT1202422A1
!WARNING
ELECTRICAL SHOCK HAZARD
Failure to turn off electric power could result in personal injury or death.
Before installing or servicing system, turn off main power to the system. There may be more than one disconnect switch, including accessory heater(s).
440 03 4221 00 March. 2012
PARTS MANUAL |
|
|
|
|
|
|
|
|
|
|
Gas Furnace: F9MVT, G9MVT |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
MODEL NUMBER IDENTIFICATION GUIDE |
|
|
|
|
|
|||||||||
DIGIT POSITION |
1 |
2 |
|
3 |
|
4 |
5 |
|
6,7,8 |
|
9,10 |
11,12 |
13 |
14 |
|
|
(F/G) = Mainline |
* |
9 |
|
M |
|
V |
T |
|
060 |
|
17 |
14 |
A |
1 |
|
|
N = Entry |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
9 = 90+% AFUE |
EFFICIENCY |
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
M = Multiposition |
|
|
POSITION |
|
|
|
|
|
|
|
|
|
|
|||
A = Modulating ECM Variable Speed Blower |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
V = ECM Variable Speed |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
X = ECM Blower |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
S = Single−stage |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
T = Two−stage |
|
|
|
|
|
TYPE |
|
|
|
|
|
|
|
|
|
|
C = Communicating |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
E = Extra AFUE Efficiency |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
T = Two−Stage |
|
|
|
|
|
FEATURE |
|
|
|
|
|
|
|
|||
040 = 40,000 BTU/hr |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
060 = 60,000 BTU/hr |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
080 = 80,000 BTU/hr |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
100 = 100,000 BTU/hr |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
120 = 120,000 BTU/hr |
|
|
|
|
|
|
|
HEAT INPUT |
|
|
|
|
|
|||
14 |
= 14−3/16” |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
17 |
= 17−1/2” |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
21 |
= 21” |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
24 |
= 24−1/2” |
|
|
|
|
|
|
|
|
CABINET WIDTH |
|
|
|
|
||
08 |
= 800 CFM |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
12 |
= 1200 CFM |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
14 |
= 1400 CFM |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
16 |
= 1600 CFM |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
20 |
= 2000 CFM |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
22 |
= 2200 CFM |
|
|
|
NOMINAL MAXIMUM COOLING AIRFLOW @ .5 IN. W.C. |
|
|
|
||||||||
SALES (MAJOR) REVISION DIGIT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ENGINEERING (MINOR) REVISION DIGIT |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
ECM-Electronically Commutated Motor |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||
|
ACCESSORIES PART NUMBER IDENTIFICATION GUIDE |
|
|
|
|
|||||||||||
DIGIT POSITION |
|
|
|
|
1 |
2 |
|
3 |
|
4 |
5, 6, 7 |
8, 9 |
10, 11 |
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
N |
A |
|
H |
|
A |
001 |
01 |
DH |
|
N = Non−Branded |
|
|
|
|
BRANDING |
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
A = Accessory |
|
|
|
|
PRODUCT GROUP |
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
H = Heating |
|
|
|
|
|
|
|
KIT USAGE |
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
A = Original |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
B = 2nd Generation |
|
|
|
|
|
|
|
|
MAJOR SERIES |
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Product Identifier Number |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Package Quantity |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||
Type of Kit (Example: DH = Draft Hood − Chimney Adapter) |
|
|
|
|
|
|
|
|
|
|
|
2 |
440 03 4221 00 |
PARTS MANUAL |
Gas Furnace: F9MVT, G9MVT |
|
|
PARTS DIAGRAM
NOTE: This illustration is for reference only. Your unit may differ in appearance or may not include all components shown.
X
A
D
PP
23
MM |
M |
Z
|
|
ZZ |
|
|
G |
B |
C |
3 |
|
|
E |
8 |
7 |
5 |
|
|
|
30 |
|
VV |
J
13
31
KK 9MAC−1
440 03 4221 00 |
3 |
PARTS MANUAL |
Gas Furnace: F9MVT, G9MVT |
|
|
PARTS DIAGRAM
NOTE: This illustration is for reference only. Your unit may differ in appearance or may not include all components shown.
14
P
15
12
T |
TT |
10
16A
16B
11
9MAC−2
4 |
440 03 4221 00 |