PARTS MANUAL Gas Furnace F9MVT, G9MVT

Safety Labeling and Signal Words

DANGER, WARNING, CAUTION, and NOTE

The signal words DANGER, WARNING, CAUTION, and NOTE are used to identify levels of hazard seriousness. The signal word DANGER is only used on product labels to signify an immediate hazard. The signal words WARNING, CAUTION, and NOTE will be used on product labels and throughout this manual and other manuals that may apply to the product.

DANGER − Immediate hazards which will result in severe personal injury or death.

WARNING − Hazards or unsafe practices which could result in severe personal injury or death.

CAUTION − Hazards or unsafe practices which may result in minor personal injury or product or property damage.

NOTE − Used to highlight suggestions which will result in enhanced installation, reliability, or operation.

Signal Words in Manuals

The signal word WARNING is used throughout this manual in the following manner:

!WARNINGWARN G

The signal word CAUTION is used throughout this manual in the following manner:

!CAUTION

Signal Words on Product Labeling

Signal words are used in combination with colors and/or pictures on product labels.

TABLE OF CONTENTS

Model Number Identification . . . . . . . . . . . . . . . . . . . . . 2

Parts Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

9

MODELS

F9MVT0401410A1 . . . . . . . . . . . . . G9MVT0401410A1 F9MVT0601714A1 . . . . . . . . . . . . . G9MVT0601714A1 F9MVT0801716A1 . . . . . . . . . . . . . G9MVT0801716A1 F9MVT0802120A1 . . . . . . . . . . . . . G9MVT0802120A1 F9MVT1002116A1 . . . . . . . . . . . . . . G9MVT1002116A1 F9MVT1002120A1 . . . . . . . . . . . . . G9MVT1002120A1 F9MVT1202422A1 . . . . . . . . . . . . . G9MVT1202422A1

!WARNING

ELECTRICAL SHOCK HAZARD

Failure to turn off electric power could result in personal injury or death.

Before installing or servicing system, turn off main power to the system. There may be more than one disconnect switch, including accessory heater(s).

440 03 4221 00 March. 2012

PARTS MANUAL

 

 

 

 

 

 

 

 

 

 

Gas Furnace: F9MVT, G9MVT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODEL NUMBER IDENTIFICATION GUIDE

 

 

 

 

 

DIGIT POSITION

1

2

 

3

 

4

5

 

6,7,8

 

9,10

11,12

13

14

 

(F/G) = Mainline

*

9

 

M

 

V

T

 

060

 

17

14

A

1

 

N = Entry

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9 = 90+% AFUE

EFFICIENCY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M = Multiposition

 

 

POSITION

 

 

 

 

 

 

 

 

 

 

A = Modulating ECM Variable Speed Blower

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V = ECM Variable Speed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X = ECM Blower

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S = Single−stage

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T = Two−stage

 

 

 

 

 

TYPE

 

 

 

 

 

 

 

 

 

C = Communicating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E = Extra AFUE Efficiency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T = Two−Stage

 

 

 

 

 

FEATURE

 

 

 

 

 

 

 

040 = 40,000 BTU/hr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

060 = 60,000 BTU/hr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

080 = 80,000 BTU/hr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100 = 100,000 BTU/hr

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

120 = 120,000 BTU/hr

 

 

 

 

 

 

 

HEAT INPUT

 

 

 

 

 

14

= 14−3/16”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

17

= 17−1/2”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

= 21”

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24

= 24−1/2”

 

 

 

 

 

 

 

 

CABINET WIDTH

 

 

 

 

08

= 800 CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

= 1200 CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

= 1400 CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

= 1600 CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

= 2000 CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

= 2200 CFM

 

 

 

NOMINAL MAXIMUM COOLING AIRFLOW @ .5 IN. W.C.

 

 

 

SALES (MAJOR) REVISION DIGIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENGINEERING (MINOR) REVISION DIGIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ECM-Electronically Commutated Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACCESSORIES PART NUMBER IDENTIFICATION GUIDE

 

 

 

 

DIGIT POSITION

 

 

 

 

1

2

 

3

 

4

5, 6, 7

8, 9

10, 11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

A

 

H

 

A

001

01

DH

 

N = Non−Branded

 

 

 

 

BRANDING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A = Accessory

 

 

 

 

PRODUCT GROUP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H = Heating

 

 

 

 

 

 

 

KIT USAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A = Original

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

B = 2nd Generation

 

 

 

 

 

 

 

 

MAJOR SERIES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Product Identifier Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Package Quantity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of Kit (Example: DH = Draft Hood − Chimney Adapter)

 

 

 

 

 

 

 

 

 

 

 

2

440 03 4221 00

International Comfort Products F9MVT0401410A1, G9MVT0401410A1, F9MVT0601714A1, G9MVT0601714A1, F9MVT0801716A1 User Manual

PARTS MANUAL

Gas Furnace: F9MVT, G9MVT

 

 

PARTS DIAGRAM

NOTE: This illustration is for reference only. Your unit may differ in appearance or may not include all components shown.

X

A

D

PP

23

MM

M

Z

 

 

ZZ

 

 

G

B

C

3

 

 

E

8

7

5

 

 

30

 

VV

J

13

31

KK 9MAC−1

440 03 4221 00

3

PARTS MANUAL

Gas Furnace: F9MVT, G9MVT

 

 

PARTS DIAGRAM

NOTE: This illustration is for reference only. Your unit may differ in appearance or may not include all components shown.

14

P

15

12

T

TT

10

16A

16B

11

9MAC−2

4

440 03 4221 00

Loading...