Intermatic ET171CR User Manual

Document1 8/26/03 8:38 AM Page 1
TIMER SUPPLY:
120 V.A.C. 60 Hz. 3.0 Watts maximum
SWITCH RATING:
MODEL: ET171CR
IN TYPE 3R RAINPROOF ENCLOSURE, SUITABLE FOR POOL EQUIPMENT CONTROL IF INSTALLED 5 FT. OR MORE FROM EDGE OF POOL.
•30 Amps Inductive/Resistive 24/120/240V A.C., 60 Hz.
•20 Amps Resistive 28V D.C. • 1
•2
•20 Amps Ballast 277V A.C., 60 Hz.
TIMER
POWER
ELECTRONIC
rating shown above. | PROGRAMMING |
|
RESET TIME SWITCH:
•Press recessed RESET switch to reset microprocessor and remove all previous set points.
TO SET TIME AND DAY OF WEEK:
•Place three position selector in PROGRAM.
•Place two position selector in CLK.
•Press HOUR andMINUTE buttons to select current time and day (day
1is Sunday, day 2 Monday, etc.,). Note clock is 12 hour AM/PM repeating.
TO PROGRAM SET POINTS:
•Place three position selector in PROGRAM.
•Place two position selector in OUTPUT.
•Press HOUR andMINUTE buttons to select set point time.
•Press DAY button to select day whichON orOFF set point is to occur.
•Press ON/OFF button to selectON orOFF set points.
•Press ENTER to enter selected set point time for the day selected.
•To repeat the same set point for other day(s), use DAY button to select the next day the set point is to occur, then pressENTER.
•Repeat for as many days as required.
•Repeat above procedure for all remaining set points required.
TO REVIEW PROGRAM SET POINTS:
•Place three position selector in PROGRAM.
•Place two position selector in OUTPUT.
•Display will show all zeros if there are no set points programmed.
•If set points have been entered, the display will show a program time, ON orOFF and the day theON/OFF switching operation is to occur. The display shows the first set point in chronological order beginning with Sunday (day 1).
•Press ENTER to review all remaining set points in chronological sequence.
•The display shows “E:nd” after last set point is displayed.
TO ADD OR DELETE SET POINTS:
•To add set point time, press HOUR and /orMINUTE to change time displayed. Then pressENTER. Set point is now added.
•To delete a set point, press ON/OFF two times (display will show all dashes).
*FOR AUTOMATIC OPERATION, THREE POSITION SWITCH MUST BE IN “AUTO”.
For battery | replacement, | use industrial grade | AA standard nonrechargeable | ||
battery | 1.5 | volts. To replace battery, press battery tray in | and downward to | ||
remove | the | battery holder. | Replace battery, being | sure to | observe the correct |
battery polarity. Replace battery __/__/__ (3 yrs. after installation of Time Switch).