CWT-00
C1100
Chilled Water Tank & Cold Only Faucet
Owner’s Manual
Installation, Care & Use
Instalacion, cuidado & uso
Congratulations on your purchase of this quality InSinkErator® water product. In addition
to complete operating and care instructions, in this Owner’s Manual you will find instructions for installing both:
•CWT-00 Chilled Water Tank with an existing hot/cool water dispenser – See pages 4-6
•CWT-00 Chilled Water Tank with a C1100 Cold Only Faucet – See pages 7-9
WHAT YOU SHOULD KNOW BEFORE YOU BEGIN
■IMPORTANT: After unpacking chilled water tank, place the unit upright for 1 hour before connecting power.
■For best results, the cold water faucet should be installed prior to installing the chilled water tank.
■For your satisfaction and safety, read all instructions, cautions, warnings and dangers before installing or using this chilled water tank.
■This particular unit is not intended for commercial use.
■Make sure that all electrical wiring and connections conform to local codes.
■A standard 120-volt grounded electrical outlet is required under the sink for the chilled water tank’s electrical power.
■It is recommended that a separate circuit providing power only to the chilled water tank be used.
■The wall outlet powering the chilled water tank must be fused and should not be controlled by the same wall switch used by the food waste disposer.
■It is recommended that a dedicated control valve be installed on the cold water line supplying water to this system. Make sure all water supply control valves do not have a backflow preventer in them.
■If you suspect elevated levels of chlorine in your water, it is recommended to use our water filtration system.
■The water pressure to the chilled water tank should be between a minimum of 30 psi (207kPa) and a maximum of 100 psi (689kPa).
■The chilled water tank may cause an increase in temperature in your cabinet when running.
■The chilled water tank has a refrigeration compressor, which may generate noise while running.
■The chilled water tank should only be installed in an upright position.
■The chilled water tank is intended only for chilling water.
WHAT YOU NEED TO GET STARTED
Equipment Required: (sold separately)
■ Cold water faucet |
■ Adjustable wrench |
■ T-fitting |
■ Utility knife |
■ Dedicated control valve |
■ Tape measure / ruler |
Equipment You May Need: |
■ Hole saw / hole punch ■ Basin wrench |
If you will be installing a dedicated cold only water faucet and intend to use the sprayer hole in your sink for that faucet, you may need a basin wrench and a 1/8" plug or a 1/4" hose line cap (not supplied).
If you need to cut a mounting hole in your stainless steel sink, you may need a 11⁄4" - 11⁄2" hole saw made for cutting stainless steel or a hole punch. Consult a professional if you are drilling into a surface other than stainless steel.
2
HOW TO USE THIS INSTRUCTION MANUAL
These instructions are separated into main sections, indicated by numbers, and subsections, indicated by capital letters. The manual is setup this way to allow you to take a break at any point after completing a section or subsection without affecting the installation process.
What you’ll see in the instruction manual:
B
Outlet
2
3
Property Damage: Do not pinch or break tubing. Do not distort the last 1 inch of tubing.
Attach supplied quick connect elbow to end of supplied blue 1/4" tube.
Attach quick connect elbow with on front
|
tank outlet to |
water supply line on |
Carefully |
trim blue tube to correct |
1 . |
Using quick connect elbow, connect blue tube to faucet water supply.
1
2Contains simple illustrations that provide visual instruction to support the narrative.
3CAUTIONS, WARNINGS and DANGERS that will require your attention during the step.
An imminently hazardous situation, which, if not avoided, will result in death or serious injury.
A potentially hazardous situation, which, if not avoided, could result in death or serious injury.
A potentially hazardous situation, which, if not avoided, may result in minor or moderate injury.
PACKAGE COMPONENTS
|
CWT-00 |
C1100 |
|
White Tubing - 4' |
|
|
Rubber O-Ring |
|
|
|
|
|
|
|
Hex Nut |
Blue Tubing - 4' |
|
|
|
“Y” Quick Connector |
|
|
Semi-circular Mounting Plate |
|
|
|
|
Quick Connect Elbows (3) |
Chilled Water Tank |
Cold Only Faucet |
Hex Tool |
3
These instructions assume hot/cool faucet has already been installed. Refer to Installation, Care & Use manual included with hot/cool water dispenser.
Follow these steps for installing chilled water tank with instant hot/cool water dispenser.
1 APREPARATION
< 18"
<11"
< 15"
Property Damage: Do not place objects on top of chilled water tank which could obstruct the fan.
■Unplug instant hot water tank and hold handle in open position until cool water flows from spout.
■Turn off water supply.
■Identify the undersink location for the chilled water tank.
■For best performance, allow for a minimum 2" space around the sides and top of the chilled water tank.
■The chilled water tank will require a minimum footprint of 15" wide by 11" deep.
■Ensure that there is a minimum of 18" vertical clearance for the chilled water tank.
OVERVIEW OF A TYPICAL INSTALLATION with Instant Hot Water Dispenser
Shown with optional filtration
Instant Hot/Cool
Water Dispenser Faucet
Copper Tubing
Food
Waste
Disposer
Blue Tubing
Filter
|
Air-Activated |
|
Instant |
SinkTop Switch™ |
|
White Tubing |
||
Hot Water |
||
|
||
Tank |
|
Note: Chilled water tank must be plugged directly into open wall outlet.
4
Follow these steps for installing chilled water tank with instant hot/cool water dispenser.
2 AINSTALLING THE WATER TANK |
to |
|||
|
|
|
Inlet |
|
|
|
|
|
on |
|
|
|
chilled water tank to water supply valve |
|
|
|
|
(See Step 3). Carefully trim white 1/4" |
|
|
|
Property Damage: All tub |
tube, allowing ample slack in tubing. |
|
|
|
squarely with no |
|
|
|
B |
|
■ Attach supplied quick connect elbow to |
|
|
|
|
Outlet |
|
|
White Tape |
|
|
|
|
|
|
water tank outlet to water supply line |
|
|
|
|
on faucet. Carefully trim blue tube to |
|
|
|
|
correct length. |
|
|
Property Damage: Do not |
■ Using quick connect elbow, connect |
||
|
|
Do not distort the last 1 |
remaining end of blue tube to unmarked |
|
3 |
Pull on connection to ensu |
copper tube coming from faucet. |
|
|
A |
WATER CONNECTION |
|
||
From |
■ Install a T-fitting (not included) |
|
||
|
water |
onto the cold water supply line. |
|
|
|
|
Brass Nut |
|
|
|
|
Ferrule |
|
|
|
|
Brass Insert |
■ Install dedicated water control valve |
|
|
|
|
||
|
|
|
with 3/8" compression fitting. |
|
|
|
|
■ Install brass nut, ferrule and tube insert |
|
|
|
|
on to white 3/8" tube which runs from |
|
|
|
|
filter or “Y” quick-connect fitting. |
|
|
Property Damage: Join |
■ Insert the white 3/8" tube into the 3/8" |
||
|
to cold water supply only |
compression fitting and tighten. |
|
|
|
valves must not prevent b |
|
|
B |
To hot water |
dispenser |
|
White Tape |
|
To chilled water tank “Inlet”
To remove tube(s) or plug depress the release ring and
■Remove existing “Y” quick-connect fitting and discard.
■Connect white 3/8" tube from the filter or water supply into the supplied “Y” quick-connect fitting until it stops.
■Insert 1/4" white tube from tank inlet into the 3/8" to 1/4" quick-connect fitting.
■Identify copper HOT water tube, which is marked with white tape. Install that tube into the 3/8" to 1/4" quick-connect fitting.
5
Follow these steps for installing chilled water tank with instant hot/cool water dispenser.
FILL TANK & CONNECT POWER |
||
4 A |
■ Turn on the cold water supply. |
|
|
■ Depress the cold faucet handle |
|
|
and hold it until water flows from |
|
|
the spout. |
|
|
■ Allow water to run for at least |
|
|
60 seconds after water begins to |
|
|
flow from faucet. |
|
Property Damage: Before plugging in |
■ Depress the hot water handle until |
|
chilled water tank, check for leaks in all |
water flows smoothly. |
|
water supply connections. |
||
|
B
Property Damage: A standard grounded outlet is required under the sink.
Do not use an extension cord set with the chilled water tank.
■Check all connections to ensure they are tight and that there are no leaks.
■Plug in chilled water tank and hot water dipenser tank.
■Prior to drinking water from the chilled water tank, run the water for at least 5 minutes to flush lines.
Allow up to 60 minutes for water to reach target temperature.
Gurgling or hissing is normal during the initial heating cycle.
The SinkTop Switch™ from InSinkErator® conveniently switches power between two electrical outlets, which allows the chilled water tank, hot water dispenser and food waste disposer to be connected to the same electrical outlet. The chilled water tank should not be plugged into the SinkTop Switch. The chilled water tank must be connected directly into the open wall outlet. For more information visit www.insinkerator.com.
6
The instructions on pages 7-9 will guide you through the installation of the InSinkErator C1100 Cold Only Faucet and your Chilled Water Tank.
InSinkErator C1100
Cold Only Faucet
Follow these steps for installing chilled water tank with a cold only faucet.
1 APREPARATION
< 18"
<11"
< 15"
Property Damage: Do not place objects on top of chilled water tank which could obstruct the fan.
■Turn off water supply.
■Identify the undersink location for the chilled water tank.
■For best performance, allow for a minimum 2" space around the sides and top of the chilled water tank.
■The chilled water tank will require a minimum footprint of 15" wide by 11" deep.
■Ensure that there is a minimum of 18" vertical clearance for the chilled water tank.
OVERVIEW OF A TYPICAL INSTALLATION with Cold Only Faucet
Shown with optional filtration
Cold Only Faucet
Blue Tubing |
Copper Tubing |
|
|
|
|
|
|
Food |
|
White Tubing |
Waste |
|
Disposer |
Filter
Air-Activated
Chilled SinkTop Switch™
Water
Tank
7
Follow these steps for installing chilled water tank with a cold only faucet.
INSTALLING THE COLD ONLY FAUCET |
|
2 A |
components. |
|
surface, carefully |
|
copper tubing. |
|
black O-ring is |
|
properly seated in the base of the |
|
faucet (the groove on the underside |
Property Damage: Do not pinch |
of the faucet base). |
|
|
tubing. Do not distort the last |
|
B
An assistant may be needed the faucet in place
while securing the
■Feed tube down through sink hole until the base is at rest.
■From under the sink, place the semi-circular mounting plate onto the threaded stud.
■Place hex nut onto the threaded stud. Ensure faucet is at desired angle.
■Insert screwdriver into hole on side of hex tool (creating a “T”), and use tool to tighten nut and secure faucet.
3 |
INSTALLING |
|
TANK |
|
|
■ Attach supplied quick connect elbow to |
|
|
|
|
end of supplied white 1/4" tube. |
|
Inlet |
|
■ Attach quick connect elbow to water |
|
|
|
Inlet on front of chilled water tank. |
|
|
|
■ Measure distance from water inlet on |
|
|
|
chilled water tank to water supply |
|
|
|
valve (See Step 3). Carefully trim white |
|
Property Damage: All t |
|
1/4" tube, allowing ample slack in tubing. |
|
|
|
|
|
squarely with |
|
|
|
B |
|
■ Attach supplied quick connect elbow to |
|
|
|
end of supplied blue 1/4" tube. |
|
Inlet |
|
■ Attach quick connect elbow with blue |
|
|
|
tube to water Outlet on front of chilled |
|
|
|
water tank. |
|
|
|
■ Measure distance from chilled water tank |
|
|
|
outlet to water supply line on faucet. |
|
Property Damage: Do not |
. |
Carefully trim blue tube to correct length. |
|
■ Using quick connect elbow, connect |
||
|
Do not distort the last |
|
|
|
Pull on connection to en |
|
blue tube to faucet water supply. |
8