InSinkErator CWT-00, F-C1100 User Manual

0 (0)

CWT-00

C1100

Chilled Water Tank & Cold Only Faucet

Owner’s Manual

Installation, Care & Use

Instalacion, cuidado & uso

Congratulations on your purchase of this quality InSinkErator® water product. In addition

to complete operating and care instructions, in this Owner’s Manual you will find instructions for installing both:

CWT-00 Chilled Water Tank with an existing hot/cool water dispenser – See pages 4-6

CWT-00 Chilled Water Tank with a C1100 Cold Only Faucet – See pages 7-9

WHAT YOU SHOULD KNOW BEFORE YOU BEGIN

IMPORTANT: After unpacking chilled water tank, place the unit upright for 1 hour before connecting power.

For best results, the cold water faucet should be installed prior to installing the chilled water tank.

For your satisfaction and safety, read all instructions, cautions, warnings and dangers before installing or using this chilled water tank.

This particular unit is not intended for commercial use.

Make sure that all electrical wiring and connections conform to local codes.

A standard 120-volt grounded electrical outlet is required under the sink for the chilled water tank’s electrical power.

It is recommended that a separate circuit providing power only to the chilled water tank be used.

The wall outlet powering the chilled water tank must be fused and should not be controlled by the same wall switch used by the food waste disposer.

It is recommended that a dedicated control valve be installed on the cold water line supplying water to this system. Make sure all water supply control valves do not have a backflow preventer in them.

If you suspect elevated levels of chlorine in your water, it is recommended to use our water filtration system.

The water pressure to the chilled water tank should be between a minimum of 30 psi (207kPa) and a maximum of 100 psi (689kPa).

The chilled water tank may cause an increase in temperature in your cabinet when running.

The chilled water tank has a refrigeration compressor, which may generate noise while running.

The chilled water tank should only be installed in an upright position.

The chilled water tank is intended only for chilling water.

WHAT YOU NEED TO GET STARTED

Equipment Required: (sold separately)

Cold water faucet

Adjustable wrench

T-fitting

Utility knife

Dedicated control valve

Tape measure / ruler

Equipment You May Need:

■ Hole saw / hole punch ■ Basin wrench

If you will be installing a dedicated cold only water faucet and intend to use the sprayer hole in your sink for that faucet, you may need a basin wrench and a 1/8" plug or a 1/4" hose line cap (not supplied).

If you need to cut a mounting hole in your stainless steel sink, you may need a 114" - 112" hole saw made for cutting stainless steel or a hole punch. Consult a professional if you are drilling into a surface other than stainless steel.

2

HOW TO USE THIS INSTRUCTION MANUAL

These instructions are separated into main sections, indicated by numbers, and subsections, indicated by capital letters. The manual is setup this way to allow you to take a break at any point after completing a section or subsection without affecting the installation process.

What you’ll see in the instruction manual:

B

Outlet

2

3

Property Damage: Do not pinch or break tubing. Do not distort the last 1 inch of tubing.

Attach supplied quick connect elbow to end of supplied blue 1/4" tube.

Attach quick connect elbow with on front

 

tank outlet to

water supply line on

Carefully

trim blue tube to correct

1 .

Using quick connect elbow, connect blue tube to faucet water supply.

1

2Contains simple illustrations that provide visual instruction to support the narrative.

3CAUTIONS, WARNINGS and DANGERS that will require your attention during the step.

An imminently hazardous situation, which, if not avoided, will result in death or serious injury.

A potentially hazardous situation, which, if not avoided, could result in death or serious injury.

A potentially hazardous situation, which, if not avoided, may result in minor or moderate injury.

PACKAGE COMPONENTS

 

CWT-00

C1100

White Tubing - 4'

 

 

Rubber O-Ring

 

 

 

 

 

 

Hex Nut

Blue Tubing - 4'

 

 

 

“Y” Quick Connector

 

 

Semi-circular Mounting Plate

 

 

 

Quick Connect Elbows (3)

Chilled Water Tank

Cold Only Faucet

Hex Tool

3

InSinkErator CWT-00, F-C1100 User Manual

These instructions assume hot/cool faucet has already been installed. Refer to Installation, Care & Use manual included with hot/cool water dispenser.

Follow these steps for installing chilled water tank with instant hot/cool water dispenser.

1 APREPARATION

< 18"

<11"

< 15"

Property Damage: Do not place objects on top of chilled water tank which could obstruct the fan.

Unplug instant hot water tank and hold handle in open position until cool water flows from spout.

Turn off water supply.

Identify the undersink location for the chilled water tank.

For best performance, allow for a minimum 2" space around the sides and top of the chilled water tank.

The chilled water tank will require a minimum footprint of 15" wide by 11" deep.

Ensure that there is a minimum of 18" vertical clearance for the chilled water tank.

OVERVIEW OF A TYPICAL INSTALLATION with Instant Hot Water Dispenser

Shown with optional filtration

Instant Hot/Cool

Water Dispenser Faucet

Copper Tubing

Food

Waste

Disposer

Blue Tubing

Filter

 

Air-Activated

Instant

SinkTop Switch

White Tubing

Hot Water

 

Tank

 

Note: Chilled water tank must be plugged directly into open wall outlet.

4

Follow these steps for installing chilled water tank with instant hot/cool water dispenser.

2 AINSTALLING THE WATER TANK

to

 

 

 

Inlet

 

 

 

 

 

on

 

 

 

chilled water tank to water supply valve

 

 

 

(See Step 3). Carefully trim white 1/4"

 

 

Property Damage: All tub

tube, allowing ample slack in tubing.

 

 

 

squarely with no

 

 

 

B

 

Attach supplied quick connect elbow to

 

 

 

Outlet

 

 

White Tape

 

 

 

 

 

water tank outlet to water supply line

 

 

 

on faucet. Carefully trim blue tube to

 

 

 

correct length.

 

 

Property Damage: Do not

Using quick connect elbow, connect

 

 

Do not distort the last 1

remaining end of blue tube to unmarked

3

Pull on connection to ensu

copper tube coming from faucet.

 

A

WATER CONNECTION

 

From

Install a T-fitting (not included)

 

 

water

onto the cold water supply line.

 

 

 

Brass Nut

 

 

 

Ferrule

 

 

 

 

Brass Insert

Install dedicated water control valve

 

 

 

 

 

 

with 3/8" compression fitting.

 

 

 

 

Install brass nut, ferrule and tube insert

 

 

 

on to white 3/8" tube which runs from

 

 

 

filter or “Y” quick-connect fitting.

 

 

Property Damage: Join

Insert the white 3/8" tube into the 3/8"

 

to cold water supply only

compression fitting and tighten.

 

 

valves must not prevent b

 

 

B

To hot water

dispenser

White Tape

 

To chilled water tank “Inlet”

To remove tube(s) or plug depress the release ring and

Remove existing “Y” quick-connect fitting and discard.

Connect white 3/8" tube from the filter or water supply into the supplied “Y” quick-connect fitting until it stops.

Insert 1/4" white tube from tank inlet into the 3/8" to 1/4" quick-connect fitting.

Identify copper HOT water tube, which is marked with white tape. Install that tube into the 3/8" to 1/4" quick-connect fitting.

5

Follow these steps for installing chilled water tank with instant hot/cool water dispenser.

FILL TANK & CONNECT POWER

4 A

Turn on the cold water supply.

 

Depress the cold faucet handle

 

and hold it until water flows from

 

the spout.

 

Allow water to run for at least

 

60 seconds after water begins to

 

flow from faucet.

Property Damage: Before plugging in

Depress the hot water handle until

chilled water tank, check for leaks in all

water flows smoothly.

water supply connections.

 

B

Property Damage: A standard grounded outlet is required under the sink.

Do not use an extension cord set with the chilled water tank.

Check all connections to ensure they are tight and that there are no leaks.

Plug in chilled water tank and hot water dipenser tank.

Prior to drinking water from the chilled water tank, run the water for at least 5 minutes to flush lines.

Allow up to 60 minutes for water to reach target temperature.

Gurgling or hissing is normal during the initial heating cycle.

The SinkTop Switchfrom InSinkErator® conveniently switches power between two electrical outlets, which allows the chilled water tank, hot water dispenser and food waste disposer to be connected to the same electrical outlet. The chilled water tank should not be plugged into the SinkTop Switch. The chilled water tank must be connected directly into the open wall outlet. For more information visit www.insinkerator.com.

6

The instructions on pages 7-9 will guide you through the installation of the InSinkErator C1100 Cold Only Faucet and your Chilled Water Tank.

InSinkErator C1100

Cold Only Faucet

Follow these steps for installing chilled water tank with a cold only faucet.

1 APREPARATION

< 18"

<11"

< 15"

Property Damage: Do not place objects on top of chilled water tank which could obstruct the fan.

Turn off water supply.

Identify the undersink location for the chilled water tank.

For best performance, allow for a minimum 2" space around the sides and top of the chilled water tank.

The chilled water tank will require a minimum footprint of 15" wide by 11" deep.

Ensure that there is a minimum of 18" vertical clearance for the chilled water tank.

OVERVIEW OF A TYPICAL INSTALLATION with Cold Only Faucet

Shown with optional filtration

Cold Only Faucet

Blue Tubing

Copper Tubing

 

 

 

 

 

Food

 

White Tubing

Waste

 

Disposer

Filter

Air-Activated

Chilled SinkTop Switch

Water

Tank

7

Follow these steps for installing chilled water tank with a cold only faucet.

INSTALLING THE COLD ONLY FAUCET

2 A

components.

 

surface, carefully

 

copper tubing.

 

black O-ring is

 

properly seated in the base of the

 

faucet (the groove on the underside

Property Damage: Do not pinch

of the faucet base).

 

tubing. Do not distort the last

 

B

An assistant may be needed the faucet in place

while securing the

Feed tube down through sink hole until the base is at rest.

From under the sink, place the semi-circular mounting plate onto the threaded stud.

Place hex nut onto the threaded stud. Ensure faucet is at desired angle.

Insert screwdriver into hole on side of hex tool (creating a “T”), and use tool to tighten nut and secure faucet.

3

INSTALLING

 

TANK

 

 

Attach supplied quick connect elbow to

 

 

 

end of supplied white 1/4" tube.

 

Inlet

 

Attach quick connect elbow to water

 

 

 

Inlet on front of chilled water tank.

 

 

 

Measure distance from water inlet on

 

 

 

chilled water tank to water supply

 

 

 

valve (See Step 3). Carefully trim white

 

Property Damage: All t

 

1/4" tube, allowing ample slack in tubing.

 

 

 

 

squarely with

 

 

 

B

 

Attach supplied quick connect elbow to

 

 

 

end of supplied blue 1/4" tube.

 

Inlet

 

Attach quick connect elbow with blue

 

 

 

tube to water Outlet on front of chilled

 

 

 

water tank.

 

 

 

Measure distance from chilled water tank

 

 

 

outlet to water supply line on faucet.

 

Property Damage: Do not

.

Carefully trim blue tube to correct length.

 

Using quick connect elbow, connect

 

Do not distort the last

 

 

Pull on connection to en

 

blue tube to faucet water supply.

8

Loading...