Image 105071 Owner's Manual

Loading...
Image 105071 Owner's Manual

Model No. 831.105071

Serial No.

Write the serial number in the space above for reference. The serial number decal is on the frame behind the access cover.

To schedule repair service or to purchase parts

call SEARS toll-free at:

1 -800 -4-MY -HOME

®

 

(1-800

-469-4663)

 

24 hours a day 7

days week

 

To purchase or inquire about a Sears Maintenance Agreement

call SEARS toll-free at:

1 -800 -361 -6665

CAUTION

Read all precautions and instructions in this manual before

using this equipment. Save this manual for future reference.

®

USER’S MANUAL

Visit our website at

www.imagefitness.com

TABLE OF CONTENTS

IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . .

. . . .3

BEFORE YOU BEGIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . .

. . . . . . . . . . . .6

CHOOSING A LOCATION FOR THE HYDROTHERAPY SPA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

 

SET-UP AND ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . .

. . . . . . . . . .8

POSTING THE WARNING SIGN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. .

. . . . . . .10

USING THE HYDROTHERAPY SPA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . .

. . . .11

MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . .

. . . . . . . . . . . . .15

MAINTENANCE NOTES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . .

. . . . . . . . .19

TROUBLE-SHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . .

. . . . . . . . . .20

PART LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. .

. . . . . . . . . . . . . . . .22

EXPLODED DRAWING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . .

. . . . . . . . . .23

ORDERING REPLACEMENT PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Back C

over

IMAGE is a registered trademark of ICON Health & Fitness, Inc.

2

IMPORTANT SAFETY INSTRUCTIONS

WARNING: TO REDUCE THE RISK OF DROWNING, ELECTRIC SHOCK, OR SERIOUS INJURY, READ THE FOLLOWING IMPORTANT PRECAUTIONS BEFORE USING THE RENEW 515.

READ AND FOLLOW ALL INSTRUCTIONS

1.It is the responsibility of the owner to ensure that all users of the hydrotherapy spa are adequately informed of all precautions.

2.Use the hydrotherapy spa only as described

in this manual.

3.The hydrotherapy spa is intended for home use only. Do not use the spa in any commercial, rental, or institutional setting.

4.Use the hydrotherapy spa only on a level surface. Do not use the spa on carpet or other materials that could be damaged by moisture. Do not use the spa on rough or sharp surfaces such as gravel or wood chips.

5.The hydrotherapy spa will weigh approximately 2,000 pounds (908 kgs) when it is filled with water. Be sure that the location you select for the spa will support this weight, plus the weight of the occupants.

6.Inspect and tighten all parts regularly; replace any worn or missing parts immediately.

7.DANGER—Risk of injury: Do not remove or alter the covers on the suction fittings. Never operate the hydrotherapy spa if the suction guard is missing or broken. If you need to replace a suction fitting, be sure to use only manufacturer-recommended parts. Keep hair

and body parts away from the suction guard. Do not allow long hair to float freely in the water; long hair should be restrained with a bathing cap.

8.IMPORTANT: Do not allow the hydrotherapy

spa to be exposed to direct sunlight when it is empty. The surface of the spa shell can reach temperatures as high as 150°F (65°C) in a matter of minutes if exposed to the sun while it is empty. These high temperatures can cause significant damage, such as blistering of the shell surface and warping of the spa shell. Any damage caused by sun expo-

sure is not covered under warranty.

9.Do not bring any object into the hydrotherapy spa that could damage the spa shell.

10.Never insert any object into any opening.

11.Do not use breakable containers near or in

the hydrotherapy spa.

12.Do not sit on the spa cover or place objects on it. It is not designed to support weight.

13.Remove any water or debris that may collect on the spa cover.

14.Keep children under 12 and pets away from the hydrotherapy spa when it is not in use.

15.Keep all chemicals away from children and pets.

16.The pH and chemical balance of the water must be maintained as explained in this manual (see pages 11 and 16). Failure to do so may cause injury to users or damage to the spa, and it will void the warranty.

17.Individuals with infections and open sores or wounds should not use the hydrotherapy

spa. Bacteria thrive in warm and hot water. Always keep the spa disinfected and maintain the proper chemical balance.

18.Shower before and after using the hydrotherapy spa. This will remove any deodorant, perspiration, or body oils that could contaminate the water. Showering after will remove any residual chemicals and any bacteria that may have been in the spa.

19.WARNING—The Ground Fault Circuit Interrupter (GFCI), must be tested before

each use. To test the GFCI, press the “test” button while the hydrotherapy spa is running. The spa should shut off. Press the “reset” button. The spa should resume nor-

3

2) solid copper

mal operation. If the spa continues to run after the “test” button is pressed, then the GFCI is damaged. Do not use the spa until the GFCI has been repaired or replaced by a qualified electrician.

20.Keep all electrical appliances such as radios, telephones, televisions and lights at least five feet (1.5 m) away from the water.

21.DANGER—Risk of electric shock: Do not set

up the hydrotherapy spa within five feet (1.5

m)of any metal objects or surfaces. As an alternative, you may use the spa within five feet (1.5 m) of metal objects if each metal object is permanently connected to the bond-

ing LVG on the controller of this unit by a

minimum No. 6 AWG (1.3 mm

conductor. At least two lugs marked “BONDING LUGS” are provided on the external surface or on the inside of the supply terminal box or compartment. To reduce the risk of electric shock, connect the local common bonding grid in the area of the hot tub or spa to these terminals with an insulated or bare copper conductor not smaller than 6 AWG.

All field-installed metal components such as rails, ladders, drains, or other similar hardware within 3 m of the spa or hot tub shall be bonded to the equipment grounding bus with copper conductors not smaller than 6 AWG.

22.Do not operate the pump motor when the spa is empty. The pump motor may be seriously damaged if it is operated without water circu-

lating. The cut-off valves must always be open when using the spa (see step 2 on page 8).

23.DANGER—Risk of drowning: Exercise extreme caution to prevent unauthorized and unsupervised use of the hydrotherapy spa by children. Children must always be supervised.

24.DANGER—To reduce the risk of drowning:

Never use the hydrotherapy spa alone;

Children should not use the spa unless

they are supervised by an adult;

Keep pets away from the spa at all times;

Always replace and lock the spa cover

when the spa is not in use.

25.WARNING—To reduce the risk of injury: The water temperature should never exceed

104°F (40°C). Water temperature in excess of 100°F (38°C) may be injurious to your health. If you plan to remain in the hydrotherapy spa

for more than 10 to 15 minutes, lower the temperature to 100°F (38°C) or below. Lower temperatures are also recommended for chil-

dren. Children should not be allowed to swim under the surface of the water in the spa.

26. WARNING—To reduce the risk of injury: Always use an accurate thermometer to determine the water temperature before using the hydrotherapy spa.

27WARNING—To reduce the risk of injury: Pregnant women should consult with their physician before using the hydrotherapy spa. Pregnant women should not use the spa if

the water temperature is above 100°F (38°C); the unborn child could be seriously harmed.

This is especially important during the first 90 days of the pregnancy.

28.DANGER—To reduce the risk of drowning: Prolonged immersion in the hydrotherapy spa may cause hyperthermia, a dangerous condition that occurs when the internal body temperature rises several degrees above the

normal body temperature of 98.6°F (37°C). The symptoms of hyperthermia include nau-

sea, dizziness, drowsiness, and fainting. Effects include: a lack of awareness, inability to perceive heat or danger, and a greater risk of drowning due to a loss of consciousness.

Special note: Individuals suffering from hyperthermia may be unable to realize that they must exit the hydrotherapy spa, and they also may be physically unable to do so.

29.WARNING—To reduce the risk of drowning:

Do not use the hydrotherapy spa if you are under the influence of alcohol or drugs. Heat from the water, in conjunction with alcohol or drugs can cause loss of consciousness.

30.WARNING—To reduce the risk of injury or drowning: Consult your physician about possible side-effects of any medications you may be taking before using the hydrotherapy

spa. Heat from the water, in conjunction with some medications, may cause drowsiness

and increase the risk of drowning. Others

can effect blood pressure, heart rate, and circulation.

31.Do not use the hydrotherapy spa immediately after strenuous exercise.

32.To avoid injury, exercise care when entering or exiting the spa.

4

33.WARNING—To reduce the risk of injury: It is especially important for persons over the age of 35 or persons with pre-existing health problems, such as obesity, heart disease, high or low blood pressure, circulatory problems, or diabetes to consult their physician before using this product.

34.WARNING—The included warning sign must

be posted where all users of the spa can see and read it (see POSTING THE WARNING SIGN on page 13).

35. CAUTION—The hydrotherapy spa is not

designed for in-ground installation. Do not install the hydrotherapy spa in-ground.

36.Disconnect the electric power supply before servicing the spa.

37.If you feel pain or dizziness at any time while using the hydrotherapy spa, discontinue use

and contact a physician.

38.Minimum Electrical Ratings:

240 Volt Minimum Supply Conductor Ampacity: 40 Amps

240 Volt Minimum Breaker/Fuse: 40 Amps

120 Volt Minimum Supply Conductor Ampacity: 15 Amps

120 Volt Minimum Breaker/Fuse: 15 Amps

39.A green terminal or a terminal marked G, GR, Ground, Grounding, or with the symbol is located inside the supply terminal box or compartment. To reduce the risk of electric shock, this terminal must be connected to

the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in size to the circuit conductors supplying this equipment.

40.WARNING DECAL PLACEMENT: Locate the

decals shown at right and familiarize yourself with this information.

Continuous exposure of the spa surface to direct sunlight or ultra-violet rays may cause damage to

the spa’s surface, will void the warranty, and will result in potentially hazardous surface temperatures.To avoid sun damage, the cover

should be in place when the spa is not in use.

WARNING: Read all instructions before using the hydrotherapy spa. ICON assumes no

responsibility for personal injury or property damage sustained by or through the use of this product.

SAVE THESE INSTRUCTIONS

5

BEFORE YOU BEGIN

Thank you for selecting the innovative IMAGE

® Renew

For your safety and benefit, read this manual care-

 

515 hydrotherapy spa. The RENEW 515 offers the

 

fully before using the RENEW 515.

If you have addi-

features and quality of a traditional hot tub at an

 

tional questions, please call SEARS at 1-800-

 

affordable price. And best of all, the RENEW 515 lets

 

4MYHOME (469-4663), or SEARS 1-877-LEFOYER

 

you enjoy the benefits of hydrotherapy in the comfort

 

(533-6937) 24 hours a day. To help us assist you,

and privacy of your own home.

 

please note the product model number and serial num-

 

 

 

ber before calling. The model number is 831.105071.

 

Hydrotherapy is a proven method for soothing tired

 

The serial number can be found on a decal attached to

 

muscles after exercise or for relieving the stress of a

 

frame inside the spa (see the front cover of this manu-

 

busy life. The warm environment stimulates blood flow,

 

al).

 

which is essential in the healing process, and the pow-

 

 

 

erful massage action further eases tension and stress

 

Before reading further, please familiarize yourself with

throughout the body. The RENEW 515 gives you the

 

the parts that are labeled in the drawing below.

 

specialized treatment you need to feel your best.

 

 

 

 

 

Console

Spa Shell

 

 

Light

Spa Cover

Access

 

 

Filter

 

 

Cover

 

 

 

 

 

 

 

 

Cover Latch

 

Wood

Panels

Locking

 

 

 

 

 

 

Buckle

6

CHOOSING A LOCATION FOR THE HYDROTHERAPY SPA

There are many factors to consider when choosing a location to set up the hydrotherapy spa. These factors vary depending on whether you use the hydrotherapy spa inside or outside. We have listed several factors you may wish to consider as you decide where you want to use the hydrotherapy spa.

If you set up the hydrotherapy spa inside:

1.The hydrotherapy spa will increase the level of humidity in your home. The location you choose should be well ventilated. You may need to install a ventilation fan or use a dehumidifier.

2.The hydrotherapy spa should be close to a source of water.

3.Do not use the hydrotherapy spa on carpet or other material that may be damaged by moisture. We recommend that you place the hydrotherapy

spa on a waterand stain-resistant, non-slip surface with a floor drain for any water that may splash from the hydrotherapy spa.

4.Be sure that the location you choose is stable. It must be able to support the weight of the hydrotherapy spa when it is filled with water, plus the weight of the occupants. The hydrotherapy

spa weighs approximately 2,000 pounds (908 kgs) when filled with water.

5.Do not use the hydrotherapy spa above a finished living area, due to the risk of water damage.

6.Make sure that there is enough room around the

hydrotherapy spa to permit servicing. The dimen-

sions of the spa are: 5’ 10” W x 6’ 4” L x 2’ 6” H (153 cm x 183 cm x 61 cm). Allow for this size when choosing the location.

7.The hydrotherapy spa is not designed for in-floor installation. However, it is compatible with a deck system that is built flush with the top of the spa, provided you leave access to the motor for servicing.

8.Make sure to note any other considerations, such

as aesthetics or privacy concerns, that may affect the safety or enjoyment of using the hydrotherapy spa.

If you set up the hydrotherapy spa outside:

1.Check your local building codes concerning the use of outdoor spas.

2.The hydrotherapy spa should be close to a source of water.

3.We recommend that you place the hydrotherapy

spa on a waterand stain-resistant, non-slip surface. Do not use the hydrotherapy spa on rough

or sharp surfaces such as gravel or wood chips.

4.Make sure that the location you choose is stable. It must be able to support the weight of the

hydrotherapy spa when it is filled with water, plus the weight of the occupants. The hydrotherapy

spa weighs approximately 2,000 pounds (908 kgs) when filled with water.

5.Consider environmental factors such as rain, wind, shade, sunlight, etc.

6.You should be able to monitor the use of the

hydrotherapy spa from your home to prevent unauthorized use by children. You may want to enclose the spa with a fence and self-latching gate to prevent unauthorized use.

7.Make sure that there is enough room around the hydrotherapy spa to permit servicing. The dimen-

sions of the spa are: 5’ 10” W x 6’ 4” L x 2’ 6” H (153 cm x 183 cm x 61 cm). Allow for this size when choosing the location.

8.The hydrotherapy spa is not designed for in-

ground installation. However, it is compatible with a deck system that is built flush with the top of the spa, provided you leave access to the motor for servicing.

9.Make sure to note any other considerations, such as aesthetics or privacy, that may affect the safety or enjoyment of using the hydrotherapy spa.

7

SET-UP AND ASSEMBLY

Before beginning assembly, carefully read the following information and instructions:

Place all parts in a cleared area and remove the packing materials from the spa shell; do not dispose of the packing materials until assembly is completed and the spa is in operation.

Assembly requires two people.

During assembly, make sure that all parts are oriented as shown in the drawings.

Read each assembly step before you begin.

Tighten all parts as you assemble them, unless instructed to do otherwise.

ASSEMBLY REQUIRES THE FOLLOWING

TOOLS (NOT INCLUDED):

One (1) phillips screwdriver

You may also need a small amount of soap or wax.

1.

Before beginning assembly, make sure that you

1

 

have read and understand the information on

 

 

 

the previous two pages.

 

 

 

Remove the four screws from the access cover on

 

 

the console side of the spa. Remove the access

 

 

cover by sliding it down and then pulling the bottom

 

 

of it away from the spa.

Be careful not to damage

 

 

the spa shell.

 

 

Remove the power cord with the GFCI from inside the spa.

Access

Cover

Screws

Power Cord

2.Locate and check the positions of the two cut-off valves. The cut-off valves may have been closed at

the factory during manufacturing. However, the cutoff valves must be open when the spa is operated.

To open the valves, turn the handles and pull them

out to the open position. IMPORTANT: THE

MOTOR WILL BE DAMAGED IF IT IS OPERATED WITH THE CUT-OFF VALVES CLOSED.

Next, close the valve knob on the drain hose. Thread the cap onto the drain hose. Thread the

drain plug into the Pump Motor (13). Tighten the pump fittings.

2

 

 

Cut-off Valve

 

 

 

Cut-off

 

 

 

Valve

 

 

 

 

 

13

 

 

 

Drain Hose

Cap

Valve

Drain

Pump

Knob

Plug

Fittings

 

8

+ 16 hidden pages