Q U I C K S T A R T G U I D E

F I B R E C H A N N E L S W I T C H I N S T A L L A T I O N

z

 

 

S A N b o x ® 9 0 0 0 S e r i e s

 

f o r W i n d o w s ® O p e r a t i n g S y s t e m s

 

 

 

Purchasers of OEM products should consult with the OEM for support.

Support Headquarters

QLogic Corporation

 

12984 Valley View Road

 

Eden Prairie, Minnesota 55344-3657

 

USA

QLogic Web Site

www.qlogic.com

Technical Support Web Site

support.qlogic.com

Technical Support Email

support@qlogic.com

Technical Training Email

tech.training@qlogic.com

North American Region

 

Email

support@qlogic.com

Phone

+1-952-932-4040

Fax

+1 952-974-4910

Europe, Middle East, and Africa Region

 

Email

emeasupport@qlogic.com

Phone Numbers by Language

+353 1 6924960 - English

 

+353 1 6924961 - Français

 

+353 1 6924962 - Deutsch

 

+353 1 6924963 - Español

 

+353 1 6924964 - Português

 

+353 1 6924965 - Italiano

Asia Pacific Region

 

Email

apacsupport@qlogic.com

Phone Numbers by Language

+63-2-885-6712 - English

 

+63-2-885-6713 - (Mandarin)

 

+63-2-885-6714 - (Japanese)

 

+63-2-885-6715 - (Korean)

Latin and South America Region

 

Email

calasupport@qlogic.com

Phone Numbers by Language

+52 55 5278 7016 - English

 

+52 55 5278 7017 - Español

 

+52 55 5278 7015 - Português

Quick Start Guide

Installation Instructions

Congratulations on your purchase of the SANbox® 9000 Series Fibre Channel Switch. This guide describes the steps to install and activate your new switch using a Windows® workstation. For advanced options and instructions (including Solaris®, Linux®, and Mac OS X® installations), refer to the SANbox 9000 Series Stackable Chassis Switch Installation Guide on the product CD.

NOTE: Do not apply power to the switch until instructed in Step 4.

Step 1. Verify the Package Contents

The SANbox 9000 Series Fibre Channel Switch is shipped with the following items:

1SANbox 9000 Series Fibre Channel Switch

2AC Power cords

1 Rail kit

1 RJ-45/RS-232 console adapter

1 Enterprise Fabric Suite 2007 CD

NOTE: Transceivers and stacking cables, if you ordered them, are packaged separately.

Step 2. Mount the Switch

WARNING!! Two people are required to safely lift and install the switch into a rack. To avoid personal injury or damage to the switch, arrange for assistance.

You can mount the SANbox 9000 Series switch on a flat surface or in a rack. Allow minimum clearances of 2 inches in front and 8 inches in the rear for cabling.

For a rack mount, install the SANbox 9000 Series rail kit in a standard 19" rack as described in the SANbox 9000 Series Stackable Chassis Switch Rack Mounting Guide that is packaged with the switch.

Step 3. Install Transceivers

An SFP transceiver is required for each switch port that will be connected to a device.

To install an SFP transceiver, insert the transceiver into the switch port and gently press until it snaps in place. The transceiver will fit only one way. If the transceiver does not install under gentle pressure, flip it over and try again.

3

Step 4. Apply Power to the Switch

The maximum current requirements are 10 amps at 100 VAC or 4.2 amps at 240 VAC.

Attach the AC power cords to the Power Supply blades and wall outlets or power strips. Secure the strain relief bales to the plugs. Place the On/Off switches in the On position.

The switch runs its self tests and begins normal operation – this may take a few minutes. Observe the Maintenance Panel and verify that the CPU0 blade Heartbeat LED is blinking about once per second and the Chassis Fault LED is NOT illuminated.

CHASSIS

 

CHASSIS

GOOD LED

 

FAULT LED

CPU0

HEARTBEAT

LED

Step 5. Verify Workstation Requirements

Verify that your workstation can support the Enterprise Fabric Suite 2007™ application with the following minimum requirements:

Windows® 2003 SP1/SP2/R2 and XP

256 MB memory minimum; 512 MB recommended

150 MB disk space

1 GHz processor

Video card with 256 colors

CD ROM drive, RJ-45 Ethernet port

Internet Browser: Microsoft® Internet Explorer® 5.0, Netscape Navigator® 6.0, Firefox® 1.0, or Mozilla™ 1.5

Java® 2 Standard Edition Runtime Environment 1.4.2

The default IP address of a new switch is 10.0.0.1. Ensure that your workstation is configured to communicate with the 10.0.0 subnet.

4

Step 6. Connect the Workstation to the Switch

Connect the CPU0 blade Ethernet port directly to the workstation using an Ethernet cable, or indirectly through a switch or hub. The Ethernet port automatically discovers straight and cross-over cables. You must have a live Ethernet connection when the workstation powers up.

NOTE: The Maintenance Panel Ethernet ports on the front of the switch are disabled and should not be used for the initial installation. You can enable the Maintenance Panel Ethernet ports after the switch is operational.

CPU0 BLADE

ETHERNET PORT

Step 7. Install Enterprise Fabric Suite 2007

The Enterprise Fabric Suite 2007 application includes the Configuration Wizard. This wizard auto-detects and configures the switch based on selected options and recommended settings. To install the Enterprise Fabric Suite 2007 application on a Windows workstation/server, perform the following steps:t

1.Insert the Enterprise Fabric Suite 2007 disk into the CDROM drive.

2.Select the Enterprise Fabric Suite 2007 tab at the top of the screen.

3.Click Agree in response to the End User License Agreement.

4.Select Install for Windows 2003, XP.

5.Double click the Windows_6.08.xx.exe file to begin installation.

6.Enter the serial number and license key provided to activate the Enterprise Fabric Suite 2007 application.

If the product introduction screen does not open, open the CD with Windows Explorer and run the installation program with the following path:

Switch_Manager\Windows_6.08.xx.exe

Step 8. Obtain Network Configuration

Obtain the IP address and subnet mask from your network administrator. Be sure that your workstation is configured for the same subnet.

5

Step 9. Run the Configuration Wizard

Double-click the Enterprise Fabric Suite 2007 shortcut, or select Enterprise Fabric Suite 2007 from Start menu, depending on how you installed it.

The Configuration Wizard tool auto-detects and configures the switch based on selected options and recommended settings. Follow the instructions to set network parameters and the password. The default user name is admin; the default password is password.

NOTE: If you are using an Ethernet switch and the auto-connect process fails due to a time out, try a direct connection from your workstation to the switch using an Ethernet cross-over cable.

Step 10. Connect Devices and Switches

Connect fiber optic cables between the installed transceivers and their corresponding devices. Each port auto-negotiates the proper port type with the connected device or switch.

Congratulations

You have successfully installed your QLogic SANbox 9000 Series Switch

6

© 2007 QLogic Corporation. QLogic, the QLogic logo, SANbox, and Enterprise Fabric Suite 2007 are trademarks or registered trademarks of QLogic Corporation. Microsoft , Windows, and Internet Explorer are registered trademarks of the Microsoft Corporation. MacOS X is a registered trademark of Apple Computer, Inc. Linux is a registered trademark of Linus Torvalds. Mozilla and Firefox are trademarks or registered trademarks of the Mozilla Foundation. Netscape Navigator is a registered trademarks of Netscape Communications Corporation. Java and Solaris are registered trademarks of Sun Microsystems, Inc. All other brands and product names are trademarks or registered trademarks of their respective owners. Information supplied by QLogic is believed to be accurate and reliable. QLogic Corporation assumes no responsibility for any errors in this brochure. QLogic Corporation reserves the right, without notice, to makes changes in product design or specifications.

*50688-03

A*

QLogic Corporation

26650 Aliso Viejo Parkway

Aliso Viejo, CA 92656

J949.389.6000

www.qlogic.com

50688-03 A