ERserver

iSeries

Networking

iSeries Communications Management

ERserver

iSeries

Networking

iSeries Communications Management

© Copyright International Business Machines Corporation 1998, 2001. All rights reserved.

US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract with IBM Corp.

Contents

Part 1. Getting started with AS/400 communications

. . .

. . . . . . .

. . . . 1

Chapter 1.

Print this topic . . . . . . . . . . . . . .

. . . .

. . . . . . .

. .

.

.

3

Chapter 2.

Configuring AS/400 for communications . . . .

. . . .

. . . . . . .

. .

.

.

5

Creating a network interface description . . . . . . . . .

. . . .

. . . . . . .

. .

.

.

5

Creating a network server description . . . . . . . . . .

. . . .

. . . . . . .

. .

.

.

5

Creating a line description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Chapter 3. Optimizing communications performance . . . . . . . . . . . .

. . .

. .

.

7

Improving wide area network performance . . . . . . . . . . . . . . . . . .

. . .

. .

.

7

Adjusting WAN protocols for optimum AS/400 performance . . . . . . . . . .

. . .

. .

.

7

Adjusting the WAN line speed for optimum AS/400 performance. . . . . . . . .

. . .

. .

.

7

WAN line speed considerations for IOPs . . . . . . . . . . . . . . . . .

. . .

. .

.

8

Improving local area network performance . . . . . . . . . . . . . . . . . .

. . .

. .

.

9

Adjusting LANs for optimum communications performance . . . . . . . . . . .

. . .

. .

.

9

Adjusting LAN lines for optimum communications performance . . . . . . . . .

. . .

. .

.

9

LAN line speed considerations for IOPs . . . . . . . . . . . . . . . . . .

. .

. .

.

10

Improving data path performance . . . . . . . . . . . . . . . . . . . . .

. .

. .

.

10

Considerations for subsystem configuration for error recovery performance . . . . .

. .

. .

.

11

Communications performance considerations for interactive jobs . . . . . . . . .

. .

. .

.

12

Communications performance considerations for batch jobs . . . . . . . . . . .

. .

. .

.

13

Mixing interactive and batch jobs on a WAN line . . . . . . . . . . . . . . .

. .

. .

.

13

Performance considerations for AnyNet communications . . . . . . . . . . . .

. .

. .

.

14

Subsystems . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. .

. .

.

15

Chapter 4. Communications applications . . . . . . . . . . . . . . . . . .

. .

. .

.

17

User written APPC applications . . . . . . . . . . . . . . . . . . . .

.

. .

.

.

.

.

17

Distributed data management (DDM) . . . . . . . . . . . . . . . . . .

.

. .

.

.

.

.

17

Application program interface (API) performance considerations . . . . . . . .

. . . .

. .

.

17

Performance considerations for intersystem communications function . . . . .

. . . .

. .

.

18

Performance considerations for Common Programming Interface Communications

. . . .

. .

.

19

Chapter 5. Communicating with host systems . . . . . . . . . . . . . .

. . . .

. .

.

21

Matching AS/400 parameters for a host system . . . . . . . . . . . . . .

. . . .

. .

.

21

Matching AS/400 line description parameters for a host system . . . . . . .

. . . .

. .

.

21

Matching AS/400 controller description parameters for a host system . . . . .

. . . .

. .

.

23

Matching AS/400 device description parameters for a host system . . . . . .

. . . .

. .

.

24

Matching AS/400 mode and class-of-service description parameters for a host system . . . . . . 25

Configuring dependent LU requester (DLUR) . . . . . . .

. . . . . . . . .

.

. .

.

.

.

31

Configuring the host controller description . . . . . . .

. . . . . . . . .

.

. .

.

.

.

31

Configuring the device descriptions . . . . . . . . . . . . . . . . . . . . . . . . . 31

Chapter 6. Communicating with a remote AS/400 system . . . . . . .

. .

. . . . . .

.

33

Matching AS/400 line description parameters for a remote AS/400 system . .

. .

. . . . . .

.

33

Matching AS/400 controller description parameters for a remote AS/400 system

. .

. . . . . .

.

35

Matching AS/400 device description parameters for a remote AS/400 system .

. .

. . . . . .

.

36

Connecting one AS/400 to another AS/400 system . . . . . . . . . . .

. .

. . . . . .

.

37

Chapter 7. Communicating with remote workstation controllers . . . . .

. .

. . . . . .

.

41

Matching AS/400 parameters for 5494 controllers. . . . . . . . . . . .

. .

. . . . . .

.

41

Matching AS/400 parameters for a 5494 connected by token-ring . . . . .

. .

. . . . . .

.

41

Matching AS/400 parameters for a 5494 connected by Ethernet . . . . .

. .

. . . . . .

.

44

© Copyright IBM Corp. 1998, 2001

iii

Matching AS/400 parameters for a 5494 connected by frame relay . . . . . . . . . . . .

.

46

Matching AS/400 parameters for a 5494 connected by SDLC . . . . . . . . . . . . . .

.

48

Matching AS/400 parameters for a 5494 connected by X.21 . . . . . . . . . . . . . . .

.

52

Matching AS/400 parameters for a 5494 connected by X.25 . . . . . . . . . . . . . . .

.

54

Matching AS/400 parameters for 3x74 controller . . . . . . . . . . . . . . . . . . . .

.

58

Matching AS/400 parameters for a 3174 controller . . . . . . . . . . . . . . . . . .

.

58

Matching AS/400 parameters for a 3274 controller . . . . . . . . . . . . . . . . . .

.

60

Matching AS/400 parameters for finance controllers . . . . . . . . . . . . . . . . . . .

.

62

Matching AS/400 parameters for 470x finance controllers . . . . . . . . . . . . . . . .

.

62

Matching AS/400 parameters for FBSS finance controllers . . . . . . . . . . . . . . .

.

64

Matching AS/400 parameters for retail controllers . . . . . . . . . . . . . . . . . . . .

.

67

Matching AS/400 parameters for 3651 retail controllers . . . . . . . . . . . . . . . .

.

68

Matching AS/400 parameters for 3684 retail controllers . . . . . . . . . . . . . . . .

.

70

Matching AS/400 parameters for 4680/4690 LINE parameter . . . . . . . . . . . . . .

.

72

Matching AS/400 parameters for 4680/4690 LINK parameter . . . . . . . . . . . . . .

.

73

Matching AS/400 parameters for 4684 retail controllers . . . . . . . . . . . . . . . .

.

74

Chapter 8. Troubleshooting communications problems . . . . . . . . . . . . . . . .

.

79

Displaying message queues to solve communication problems . . . . . . . . . . . . . . .

.

79

Displaying the Product Activity Log to solve communication problems . . . . . . . . . . . .

.

80

Displaying the Print Error Log to solve communication problems . . . . . . . . . . . . . .

.

80

Job logs and communication problems . . . . . . . . . . . . . . . . . . . . . .

.

80

Solving communication problems using communications trace . . . . . . . . . . . . . . .

.

81

System service tools and communication problems . . . . . . . . . . . . . . . . . .

.

82

Trace Common Programming Interface (CPI) Communications (TRCCPIC) command . . . . .

. 82

Solving communication problems using the system problem log . . . . . . . . . . . . . .

.

83

Solving communication problems using status information . . . . . . . . . . . . . . . .

.

84

Considerations for system tuning during error recovery. . . . . . . . . . . . . . . . . .

.

84

Using error messages to aid in error recovery . . . . . . . . . . . . . . . . . . . . .

.

84

Solving communication problems using reason codes . . . . . . . . . . . . . . . . . .

.

84

Chapter 9. Networking concepts . . . . . . . . . . . . . . . . . . . . . . . . .

.

87

Advanced Peer-to-Peer Networking . . . . . . . . . . . . . . . . . . . . . . . . .

.

87

Advanced program-to-program communications

. . .

. . . . . . . . .

. . .

. . . .

.

.

88

Dependent LU requester support . . . . . .

. . .

. . . . . . . . .

. . .

. . . .

.

.

88

High-performance routing . . . . . . . .

. . .

. . . . . . . . .

. . .

. . . .

.

.

89

HPR architecture option sets . . . . . . . . . . . . . . . . . . . . . . . . . . . 89

Internetwork packet exchange support . . . .

. . . . . . .

. . . . . . .

. .

.

. . .

.

89

What is Systems Network Architecture. . . .

. . . . . . .

. . . . . . .

. .

.

. . .

.

90

What is TCP/IP . . . . . . . . . . . .

. . . . . . .

. . . . . . .

. .

.

. . .

.

90

Chapter 10. Common networking standards

. . . . . . .

. . . . . . .

. .

.

. . .

.

91

Local area network standards . . . . . . .

. . . . . . .

. . . . . . .

. .

.

. . .

.

91

ATM on AS/400 . . . . . . . . . . .

. . . . . . .

. . . . . . .

. .

.

. . .

.

91

Distributed data interface network . . . .

. . . . . . .

. . . . . . .

. .

.

. . .

.

91

Ethernet networks . . . . . . . . . .

. . . . . . .

. . . . . . .

. .

.

. . .

.

91

Token-ring networks . . . . . . . . .

. . . . . . .

. . . . . . .

. .

.

. . .

.

92

Wireless network . . . . . . . . . .

. . . . . . .

. . . . . . .

. .

.

. . .

.

92

Wide area network standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93

Asynchronous communications . . .

. . . . . . . . .

. . . . . . .

.

. . . .

.

.

93

Binary synchronous communications .

. . . . . . . . .

. . . . . . .

.

. . . .

.

.

93

Frame relay networks . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . 93

Integrated services digital network . . . . . . . . . . . . . . . . . . . . .

. . . . 94

Synchronous data link control network . .

. . . . . . . . . . . . . .

. .

. . .

.

.

.

94

X.25

network . . . . . . . . . . .

. . . . . . . . . . . . . .

. .

. . .

.

.

.

95

X.21

network . . . . . . . . . . .

. . . . . . . . . . . . . .

. .

. . .

.

.

.

95

iv Version 5

Part 1. Getting started with AS/400 communications

The AS/400 is an extremely versatile system for networking technologies, supporting a broad range of communication protocols. Protocols that are supported include TCP/IP, APPC, APPN, HPR, Remote workstation, asynchronous, and binary synchronous communications.

AS/400 communications configuration is done by either manually or automatically creating a set of configuration objects that represent the local and remote systems that are to communicate. The types of objects required for a communications configuration vary, depending on the type of communications being configured.

Many factors can affect the performance of the AS/400 in a communications environment. To achieve the best performance with your particular environment review the topics, Optimizing communications performance, and Communications applications.

You can configure your AS/400 system to communicate with another AS/400 system, a non-AS/400 system, or a remote controller. For information on how to do this, see the following:

vCommunicating with host systems

vCommunicating with a remote AS/400 system

vCommunicating with remote workstation controllers

Communication problems are inevitable and will probably be an issue as you manage your network. If you suspect that you are having communication problems, review the topic Troubleshooting communication problems.

Before beginning to work with AS/400 communications, you may want to review the topics, Chapter 9, “Networking concepts” on page 87 and Chapter 10, “Common networking standards” on page 91. Here, you can find information related to some of the technologies common to deploying modern networking solutions in an AS/400 environment.

© Copyright IBM Corp. 1998, 2001

1

2 Version 5

Chapter 1. Print this topic

To view or download the PDF version, select Getting started with AS/400 communications (about 721 KB or 110 pages).

To save a PDF on your workstation for viewing or printing:

1.Open the PDF in your browser (click the link above).

2.In the menu of your browser, click File.

3.Click Save As...

4.Navigate to the directory in which you would like to save the PDF.

5.Click Save.

If you need Adobe Acrobat Reader to view or print these PDFs, you can download a copy from theAdobe Web site (www.adobe.com/prodindex/acrobat/readstep.html).

© Copyright IBM Corp. 1998, 2001

3

4 Version 5

Chapter 2. Configuring AS/400 for communications

Follow these steps to configure your AS/400:

1. Depending on the type of hardware you have, you may need to refer to the following topics:

vCreating a network server description

vCreating a network interface description

2.You define lines by creating line descriptions. Depending on your hardware, the lines may be attached to a network server, or a network interface.

Creating a network interface description

Network interface descriptions for asynchronous transfer mode (ATM), frame relay, and integrated services digital network (ISDN) protocols describe the communications interface.

To create a network interface description, do the following:

1.Type one of these commands on any AS/400 command line for the type of network interface you are

creating and press F4:

v Create Network Interface (ATM) (CRTNWIATM)

vCreate Network Interface (Frame Relay Network) (CRTNWIFR)

vCreate Network Interface Description for ISDN (CRTNWIISDN)

2.Use the on-line help information to choose the correct parameter values.

3.Press Enter. The network interface description is created.

Creating a network server description

A network server description describes which Integrated PC Server the local area network (LAN) and the application will be using.

To create a network server description, do the following:

1.Type the Create Network Server Description (CRTNWSD) command on any AS/400 command line and press F4.

2.Use the on-line help information to choose the parameter settings.

3.Press Enter. The network server description is created.

Creating a line description

You create line descriptions to describe the physical line connection and the data link protocol to be used between the AS/400 system and the network.

To create line descriptions, do the following:

1.Type one of these commands on any AS/400 command line to define the type of line you are creating

and press F4.

v Create Line Description (Ethernet) (CRTLINETH)

vCreate Line Description (Distributed Data Interface (DDI)) (CRTLINDDI)

vCreate Line Description (Frame Relay) (CRTLINFR)

vCreate Line Description for (IDLC) (CRTLINIDLC)

vCreate Line Description (Synchronous Data Link Control (SDLC)) (CRTLINSDLC)

vCreate Line Description (Token-ring) (CRTLINTRN)

vCreate Line Description (Wireless) (CRTLINWLS)

vCreate Line Description (X.25) (CRTLINX25)

2.Use the online help information to choose the correct parameter values.

3.Press Enter. The line description is created.

© Copyright IBM Corp. 1998, 2001

5

6 Version 5

Chapter 3. Optimizing communications performance

Many factors can affect the performance of AS/400 application programs. To achieve the best performance with your particular communications environment, you may want to review these topics:

vImproving wide area network (WAN) performance.

vImproving local area network (LAN) performance.

vImproving data path performance.

Improving wide area network performance

To achieve better performance with your AS/400 when communicating in a wide area network (WAN), you need to consider the following:

v“Adjusting WAN protocols for optimum AS/400 performance”

v“Adjusting the WAN line speed for optimum AS/400 performance”

v“WAN line speed considerations for IOPs” on page 8

Adjusting WAN protocols for optimum AS/400 performance

Wide area network (WAN) protocols affect the communications performance on AS/400. Let us use X.25 for our example. For each X.25 communications controller, the AS/400 has some processing limitation for the line, the line speed, and the total number of virtual circuits that can be used. Performance degradation can be reduced by observing these limitations.

To optimize AS/400 performance for wide area networks, perform these tasks:

vReduce the total number of frames by using larger frames.

vTo take advantage of these large frame sizes, change the MAXFRAME parameter on the line description (LIND) to reflect the maximum value. For X.25, increase the DFTPKTSIZE and MAXFRAME parameters to their maximum value.

vConfigure a WAN line as full-duplex to provide you with a higher throughput for applications that can take advantage of this mode. This can also provide higher throughput for multiple users.

vIncrease frame relay to capacity.

The data rate for a given protocol may increase as frame size increases. Under these circumstances, the central processing unit (CPU) and the input/output processor (IOP) do not do as much processing. Fewer and larger frames also make more efficient use of the communications line (higher effective data rate) because of fewer overhead bytes and line turn-arounds.

Frame relay has equivalent performance over RS449, X.21, and V.35 assuming equal line speeds and conditions. Frame relay performance (CPU time) is similar to or slightly better than Synchronous Data Link Control. For properly tuned large transfer applications, the CPU and IOP have no problem using the line speed to capacity.

For information about configuring AS/400 communications, see the Communications Configuration book.

Adjusting the WAN line speed for optimum AS/400 performance

In many cases, the communications line is the largest contributor to overall response time in the wide area network (WAN). Therefore, you should closely plan and manage its performance. In general, having the appropriate line speed is the key consideration for gaining the best performance.

To adjust the line speed for your wide area network, perform these tasks:

vCheck the difference in performance between half-duplex utilization and full-duplex utilization on the line description.

© Copyright IBM Corp. 1998, 2001

7

vFor interactive environments, keep line use below 30% to maintain predictable and consistent response times. Exceeding 50% line use usually slows down response time. The line use can be measured with the AS/400 performance tools.

vFor large transfer environments, or for environments in which only a small number of users are sharing a line, increase line use to allow for acceptable response times.

vThe CPU usage for fractional T1 support and other high-speed WAN connections is similar to any other line that runs the same type of work. As the speed of a line increases from a traditional low speed to a high-speed or full T1/E1/J1 speed, performance characteristics may change as follows:

With interactive transactions, performance may be slightly faster.

With a large transfer, performance may be significantly faster.

With a single job, performance may be too serialized to use the entire bandwidth.

With high throughput, performance is more sensitive to frame size.

With high throughput, performance is more sensitive to application efficiency.

With synchronous data link control (SDLC), the communications controller CPU usage increases because of polling.

Additional considerations for adjusting the wide area network line speed are the following:

vA common misconception about the line speed of each attached communications line is that central processing unit (CPU) resource is used in a uniform fashion. Exact statements cannot be made about the number of lines that any given AS/400 model can support.

vMost communications applications use a lot of CPU resource (to process data, to support disk input and output) and communications line resource (to send and receive data or display I/O). The amount of line resource that is used is proportional to the total number of bytes that are sent or received on the line.

Some additional CPU resource is used to process the communications software to support the individual sends (puts or writes) and receives (gets or reads). Communications input/output processor resource is also used to support the line activity.

vWhen a single job is running disk operations or doing non-overlapped CPU processing, the communications link is idle. If several sessions transfer concurrently, then the jobs are more interleaved and make better use of the communications link.

vPolling is an important consideration for synchronous data link control (SDLC) environments. All SDLC polling is handled by the communications controller and is governed by parameters in both the line and controller descriptions.

vFor information about AS/400 configuration, see the Communications Configuration book.

vFor more information about performance tools, see the Performance Tools for AS/400 book.

WAN line speed considerations for IOPs

When configuring a communications controller, you should consider both subsystem storage and aggregate line speed. Subsystem storage is the amount of storage available on the communications controller. Aggregate line speed is the sum of individual lines speeds that are attached to the communications controller.

The following information can help you understand network line speed considerations for input/output processors (IOPs).

vFor interactive environments, you should not exceed 60% use on the communications IOP. Exceeding this threshold in a large transfer environment or with a small number of concurrent users may still offer acceptable performance. Use the AS/400 performance tools to get the utilization.

vYou can attach multiple IOPs to an AS/400 system. The maximum number of IOPs that can be attached is determined by the AS/400 model. It is important to distribute the work load across several IOPs if the performance capabilities of a single IOP is exceeded.

vEven though an IOP can support certain configurations, a given AS/400 model may not have enough system resource (for example, CPU processing capacity) to support the work load over the lines.

vThe use of larger frames generally improves large transfer performance in terms of capacity for the communications IOP and in terms of system response time. The amount of time that the IOP spends

8 Version 5

processing a larger frame is only slightly more than the amount needed to process a smaller frame. If you use larger frames to transfer a single system message or block of data, decreases the total number of frames required to complete the transfer.

vThe values for IOP use in synchronous data link control (SDLC) environments do not necessarily increase consistently with the number of work stations or with the workload. An IOP can spend more time polling when the application is not using the line. It is possible to see a relatively high IOP use at low throughput levels.

vFor information on AS/400 configuration, see the Communications Configuration book.

vFor more information on performance tools, see the Performance Tools for AS/400 book.

Improving local area network performance

To achieve better performance with your AS/400 when communicating in a local area network (LAN), you need to consider the following.

v“Adjusting LANs for optimum communications performance”

v“Adjusting LAN lines for optimum communications performance”

v“LAN line speed considerations for IOPs” on page 10

Adjusting LANs for optimum communications performance

Local area networks (LAN) affect the communications performance on AS/400. Improvements to LAN input/output (IOPs) in the areas of increased central processing unit (CPU) time, IOP capacity, and support of IOP assist make them more efficient. This efficiency allows advanced program-to-program communications (APPC) to send request units to the IOP, passing the processing cost of processing frame to the IOP.

The following information can help you understand the protocol considerations for local area networks.

vA Data Link Control (DLC) can achieve a significantly higher data rate than other supported line types. This is due to the desirable combination of having a high media speed along with large frame sizes.

vWhen several sessions use a line or LAN concurrently, the aggregate data rate may be higher than when only one session is used.

vTo achieve good performance in a multi-user interactive LAN environment, you should manage the number of active users so that LAN media use does not exceed 50%. (A 25% utilization is recommended for Ethernet environments because of media collisions that causes the program to loop). Operating at higher utilization may decrease response time because of excess queueing time for the line. In a large transfer environment in which a small number of users contend for the line, a higher line use may still offer acceptable performance.

For more information about AS/400 configuration, see the Communications Configuration book.

Adjusting LAN lines for optimum communications performance

Several parameters in the line description (LIND) and the controller description (CTLD) play an important role in system performance that you can change.

The following information can help you to understand the line considerations for local area networks.

vMAXFRAME on the line description (LIND) and the controller description (CTLD): Maximizing the frame size in a LAN environment supplies the best performance for large transfers. A large frame size does not negatively affect performance for small transfers. Configure both the AS/400 system and the other link station for large frames. Otherwise, of the two maximum frame size values, the smaller is used when you transfer data. Bridges may also limit the maximum frame size. You should change the default value from 1994 to a larger size.

vLANMAXOUT on the CTLD (for advanced program-to-program communications (APPC) environments): This parameter governs how often the sending system waits for an acknowledgment. The LANACKFRQ

Chapter 3. Optimizing communications performance 9

parameter value on one system should never have a greater value than the LANMAXOUT parameter value on the other system. The parameter values of the sending system should match the values on the receiving system.

vSetting appropriate values for the LANMAXOUT parameter along with the LAN acknowledgment frequency (LANACKFRQ) parameter for both the sending stations and receiving stations is essential for optimal performance. Other values may decrease throughput by 50% or even more if conditions trigger time-outs.

vLANWDWSTP for advanced program-to-program communications (APPC) on the controller description (CTLD): If there are network congestion or overruns to certain target system adapters, then increasing the value from the default of *NONE to 2 or more may improve performance.

In general, setting the LANMAXOUT parameter value to *CALC or 2 offers the best performance for interactive environments and adequate performance for larger transfer environments.

vFor large transfer environments, changing the LANMAXOUT value may significantly increase performance. As starting points, use the following guidelines:

When you are communicating with a recent model personal computer, increase the LANMAXOUT parameter, but keep the LANACKFRQ parameter set to *CALC. For older models of personal computers, use *CALC for both values to limit buffer overruns.

If LANACKFRQ and LANMAXOUT parameter values are changed without noticeable performance improvements, change the values back to *CALC.

For more information on AS/400 communications, see the Communications Configuration book.

LAN line speed considerations for IOPs

When configuring an AS/400 system with communications lines and local area networks (LANs), you should not overload an input/output processor (IOP) to prevent possible system performance bottlenecks.

The following information can help you to understand the line speed considerations for IOPs.

vThe integrated PC server performance is similar to the 2619 and the 2617 IOPs for host LAN functions. For send and receive scenarios, performance is equivalent. For large transfers, the 6506 IOP is slightly faster than the 2619 TRLAN IOP, but slightly slower than the 2617 Ethernet IOP. These differences are not significant enough to choose one over the other.

vThe 100 Mbps Ethernet support provides the best LAN performance. The IOP can be optimally configured to have an aggregate transfer rate of 27 Mbps. Multiple concurrent large transfers may be required to drive at that rate.

vWhen analyzing communications performance that includes the 2619 TRLAN IOP, you should be aware that resources other than the IOP use can become the bottleneck.

vYou should have the highest capacity IOP available for file serving. You should have the highest capacity IOP available for environments that use many communications input and output operations for each transaction. The highest capacity IOP also minimizes the overall response time.

See the following references for more detail:

vFor more information about AS/400 communications, see the Communications Configuration book.

vFor more information on IOP performance, see the Performance Tools for AS/400 book.

Improving data path performance

To assess the performance of your data path, you may want to review the following topics:

vConsiderations for subsystem configuration for error recovery performance

vCommunications performance considerations for interactive jobs

vConsider communications performance for batch jobs

10 Version 5

vMix interactive and batch jobs on a wide area network line

vPerformance considerations for AnyNet communications

vSubsystems

Considerations for subsystem configuration for error recovery performance

Each piece of work that runs on the AS/400 system is called a job. Each job is a single, identifiable sequence of processing actions that represents a single use of the system. The basic types of jobs performed are interactive jobs, batch jobs, spooling jobs, autostart jobs, and prestart jobs.

Jobs that run in subsystems do all work that is performed on the AS/400. As the number of users on the system increases, it becomes important for you to consider how the communications and interactive subsystems should be configured.

The configuration of subsystems has little impact in normal data path operations. However, multiple subsystems can provide multiple processes to do cleanup and recovery when error conditions occur. This can result in improved performance.

As the number of users on the system increases, you must consider the importance of how subsystems are configured:

vConsider limiting the number of devices that are serviced by a single subsystem. Between 200 and 300 devices for each subsystem are recommended. Use the following recommendations to divide these users:

The number of users in any given subsystem

The connectivity used to access the system

The type of work the users do

The geographic location of the users

vCreate additional communications and interactive subsystems to split the work into multiple subsystems.

vThe work that is performed in the QCMN subsystem is for connecting and disconnecting from the system. Error recovery considerations are important in the configuration of the communications subsystem.

vTo prevent a subsystem from ever allocating a device, ensure that there are no workstation or type entries for the devices that you do what allocated by that subsystem.

vOnly use the AT(*ENTER) option if you must allow jobs to transfer into that subsystem.

vFor each subsystem you have defined, you need to identify which users will run in which subsystems. Use the Add Work Station Entry (ADDWSE) command and the Remove Work Station Entry (RMVWSE) command. You can set up work stations entries that identify which devices that subsystem should allocate, as well as which devices a subsystem should not allocate.

Note: You can use the ADDWSE commands while the subsystem is active. However, subsystems do not reallocate device locks dynamically. Eventually, it may be necessary to end and restart the subsystems to have the device locks allocated to the desired subsystem.

To specify the devices a communications subsystem should allocate:

ADDCMNE SBSD(libname/sbsname) DEV(devname*) MODE(modename)

To specify the devices a communications subsystem should not allocate:

ADDCMNE SBSD(libname/sbsname) DEV(devname*) MODE(modename) MAXACT(0)

Note: Database and file servers run only in QSERVER. Do not attempt to allocate sessions running over the QSERVER mode description. You can do this by adding the following communication entry to your subsystem:

ADDCMNE (SBSD(libname/sbsname) DEV(devname*) MODE(QSERVER) MAXACT(0)

See the following example for a way of configuring your communications subsystem.

Chapter 3. Optimizing communications performance 11

Example: Communications subsystem configuration

1.Create a duplicate of QCMN:

CRTDUPOBJ OBJ(QCMN) FROMLIB(QSYS) OBJTYPE(*SBSD) TOLIB(MYLIB) NEWOBJ(MYCMN)

2.Set up the communication entries:

ADDCMNE SBSD(MYLIB/MYCMN) DEV(PC*)

ADDCMNE SBSD(MYLIB/MYCMN) DEV(PC*) MODE(QSERVER) MAXACT(0)

ADDCMNE SBSD(QSYS/QCMN) DEV(PC*) MODE(QPCSUPP) MAXACT(0)

3. If desired, update your system startup program to start your new subsystems automatically.

Communications performance considerations for interactive jobs

An interactive job is one that uses a keyboard and character-type display. If a job needs the user to type on the keyboard and display character results, that job is probably considered interactive. Interactive in this sense means that the job and the user depend on each other to get the work done.

To optimize communications performance for interactive jobs, consider the following:

vAttach work stations through communications requires more CPU overhead than 5250 local workstations.

vUse a twinaxial controller to provide better performance than an American National Standard Code for Information Interchange (ASCII) controller.

vKeep the line utilization below 30 percent for best performance when interactive users are attached. This will maintain predictable and consistent response times. Exceeding 50 to 60 percent line utilization will usually cause unacceptable response times.

If your system has interactive users who are connected many different ways, you should consider configuring your interactive subsystems to separate the users. Local workstation, remote workstations, 5250 display station pass-through, or Telnet are some examples of these types of connections that should be separated. When you configure interactive subsystems, identify how you want the interactive users to be separated and create the appropriate subsystem descriptions.

During error recovery, when many users risk losing their sessions at one time, an interactive subsystem can be very busy performing device recovery. This device recovery can adversely affect the work of other users in the subsystem who would otherwise be unaffected by the failure. Therefore, you may need to change how the interactive subsystems are configured. However, multiple subsystems can provide multiple processes to do cleanup and recovery when error conditions occur. This can result in improved performance.

The example below shows how to configure an interactive subsystem to allocate devices that begin with devname* and present a signon display on those display devices:

ADDWSE SBSD(libname/sbsname) WRKSTNDEV(devname*) AT(SIGNON)

Use the following example to configure an interactive subsystem so that the device name devname* is not allocated and a signon display does not appear.

ADDWSE SBSD(libname/sbsname) WRKSTNDEV(devname*) AT(*ENTER)

Adding workstation entries with AT(*ENTER) allows you to use the Transfer Job (TFRJOB) function into that subsystem. If the TFRJOB function is not required or necessary, there is no need to add the workstation entries with AT(*ENTER).

To specify the devices an interactive subsystem should allocate when the subsystem is started:

ADDWSE SBSD(libname/sbsname) WRKSTN(devname*) AT(*SIGNON)

To specify the devices an interactive subsystem should not allocate when the subsystem is started:

ADDWSE SBSD(libname/sbsname) WRKSTN(devname*) AT(*ENTER)

v See the following example for a way of configuring your interactive subsystem.

12 Version 5

Example: Interactive subsystem configuration

1.Create a subsystem description:

CRTSBSD SBSD(MYLIB/MYINTER) POOLS((1 *BASE) (2 *INTERACT))

2.Create a class

CRTCLS CLS(MYLIB/MYCLASS) RUNPTY(20)

3.add routing entries to your subsystem:

ADDRTGE SBSD(MYLIB/MYINTER) SEQNBR(10) CMPVAL(QCMDI) PGM(QSYS/QCMD) POOLID(2) ADDRTGE SBSD(MYLIB/MYINTER) SEQNBR(9999) CMPVAL(*ANY) PGM(QSYS/QCMD) POOLID(2)

4.Create a job queue, and add the job queue entry to your new subsystem:

CRTJOBQ JOBQ(MYLIB/MYJOBQ)

ADDJOBQE SBSD(MYLIB/MYINTER) JOBQ(MYLIB/MYJOBQ) MAXACT(200)

5.Set up the workstation name entries. Remove all the *ALL workstation type entries first, and then add the appropriate workstation name entries:

RMVWSE SBSD(QSYS/QINTER) WRKSTNTYPE(*ALL) ADDWSE SBSD(QSYS/QINTER) WRKSTN(QPADEV*) ADDWSE SBSD(MYLIB/MYINTER) WRKSTN(PC*)

6.If desired, update your system startup program to start your new subsystems automatically.

Communications performance considerations for batch jobs

Each piece of work run on the AS/400 system is called a job. Each job is a single, identifiable sequence of processing actions that represents a single use of the system. The basic types of jobs that are performed are interactive jobs, batch jobs, spooling jobs, autostart jobs, and prestart jobs.

Batch jobs are predefined groups of processing actions that are submitted to the system to be performed with little or no interaction between the user and the system. Batch jobs can be tuned for optimized performance.

To optimize batch jobs for communications, consider the following:

vBreak the application into pieces and having multiple batch threads (jobs) operate concurrently.

vReduce the number of open and close operations, input and output operations.

vIf you have a considerable amount of main storage available, consider using the Set Object Access (SETOBJACC) command. This command preloads the complete database file, database index, or program into the assigned main storage pool if sufficient storage is available. The objective is to improve performance by eliminating disk-read/write operations.

vTry to limit the number of communications input and output operations by doing fewer (and perhaps larger) application sends and receives when communications lines are used.

vBlock the data in the application. Try to place the application on the same system as the frequently accessed data.

For more information about batch job performance, see the Communications Management book.

Mixing interactive and batch jobs on a WAN line

When interactive users and large transfers are running on a communications line concurrently, you may need to change configuration parameters. You should be able to configure AS/400 communications to work with interactive and batch jobs.

To mix interactive and batch jobs on a wide area network (WAN) line, consider the following to keep interactive performance acceptable:

vUse Advanced Peer-to-Peer Networking (APPN) transmission priority to prioritize the interactive user’s transfer over that of the large transfer. This is the preferred method to transfer batch and interactive jobs.

Chapter 3. Optimizing communications performance 13

vChange the request/response unit size to a lower value for the large transfer. This parameter setting optimizes response time at the expense of large transfer performance.

vReduce the pacing values for the large transfer to slow it down, which allows the interactive users more windows for getting on the line.

Note: The overall central processing unit time increases for the large transfer.

For more information about AS/400 communications, see the Communications Configuration book.

Performance considerations for AnyNet communications

AnyNet communications is a good performance factor for you to consider. It is more expensive to use than any of the OS/400 protocols because you spend twice as much to run two protocols.

To optimize AnyNet performance, consider the following:

vFor send and receive pairs, the most efficient use of an interface is with its own protocol stack. That is, intersystem communications function (ICF) and common programming interface communications (CPI Communications) perform the best with advanced program-to-program communications (APPC). There is additional CPU time when the crossover between the protocols processes.

vEach communications interface performs differently depending on the scenario. ICF and CPI Communications perform the best with APPC.

Note: An alternative to AnyNet communications is to have SNA and TCP/IP running parallel or over the same lines in your network. Hence, performance implications can be surpassed by not using AnyNet.

For more information about AnyNet/400 sockets, see the book Sockets Programming .

Setting up the AnyNet environment

AnyNet/400 is an AnyNet family product. These products allow you to use application programs that are written for a certain communications protocol but also run over non-native communications protocols without changing (or even re-compiling) the application program. The choice of the destination address controls whether the request is sent over the native protocols or through the AnyNet code and on to a non-native protocol.

To configure Transmission Control Protocol/Internet Protocol (TCP/IP) over advanced program-to-program communications (APPC), you need to take two basic actions:

1.Identify the set of IP addresses to route over the SNA network.

2.Tell the system how to convert the IP address to the SNA format.

For more information about APPC Over TCP/IP Configuration, see the APPC Programming book.

For more information about IPX Support, see the Internetwork Packet Exchange (IPX) Support.

For related information about AnyNet, see:

“AnyNet communications for the AS/400 system” “Performance considerations for AnyNet communications”

AnyNet communications for the AS/400 system

AnyNet is an IBM implementation of the Multiprotocol Transport Networking (MPTN) architecture, such as AnyNet/2 and AnyNet/Multiple Virtual Storage (MVS). AnyNet capability allows applications and associated services that use application programming interfaces, such as sockets, intersystem communications function (ICF), or CPI Communications, the flexibility to use alternative network protocols, such as Systems Network Architecture (SNA) or TCP/IP. AnyNet is a family of products that allow applications that

14 Version 5

are written for one type of network protocol to run over a different type of network protocol. For example, without AnyNet, your choice of application program interface (API) dictates your choice of network protocol, or your choice of network protocol dictates your choice of APIs.

AnyNet allows you to mix and match applications with network protocols. In fact, you can do this without changing your application programs. Your destination address (such as a remote location) determines the type of network protocol to use.

vAnyNet/400 Sockets

This support converts TCP/IP addresses to SNA addresses that are based on tables that are configured by the network administrator. Programs supported include File Transfer Protocol (FTP), Simple Mail Transfer Protocol (SMTP), Simple Network Management Protocol (SNMP), PING, and user-written sockets programs.

TCP/IP over SNA

TCP/IP over IPX

vAnyNet/400 APPC (advanced program-to-program communications)

This support allows programs that are written to traditional APPC APIs (such as ICF, CPI-Communications, and CICS/400) to be run over non-APPC networks. The application program uses Location names to specify the source and destination address. A TCP/IP domain name server converts these location names to IP addresses. Programs supported include distributed data management (DDM), Distributed Relational Database Architecture (DRDA), SNA distribution services (SNADS), display station pass-through, Client Access, user-written CPI-Communications programs, and user-written ICF programs .

APPC over TCP/IP

APPC over IPX

For more information about using both AnyNet and nonAnyNet sockets, see the Sockets Programming book.

Subsystems

A subsystem is a single, predefined operating environment through which the system coordinates work flow and resource usage. OS/400 can contain several that are independent operating subsystems. The run-time characteristics of a subsystem are defined in an object that is called a subsystem description. IBM supplies several subsystem descriptions that can be used with or without modification:

QINTER

Used for interactive jobs

QBATCH

Used for batch jobs

QBASE

Used for both interactive and communications batch jobs

QCMN

Used for communications batch jobs

QSERVER

File server system

QSYSWRK

Used for general system work

QUSRWRK

This is the default subsystem used for TCP/IP Client Access Host Servers that used to run in QSYSWRK.

A new subsystem can also be defined with the Create Subsystem Description (CRTSBSD) command.

Chapter 3. Optimizing communications performance 15

For more information about creating subsystems, see the Work Management book.

16 Version 5

Chapter 4. Communications applications

Communications applications that are used in an APPC (advanced program-to-program) environment are also available to be used in an APPN and HPR environment; only the method by which data is transported is changed. APPC delivers the data from applications higher in the SNA layers down to APPN for transportation through the network. User-written APPC applications and distributed data management (DDM) are fully supported in an APPN and HPR environment. The topic, Application programming interface (API) performance considerations gives a more complete discussion of APPC applications.

When you encounter problems that indicate that the route to the remote location cannot be found, you can attempt to make the connection again with the Start Pass-Through (STRPASTHR) command. See the topic, Solving remote communication problems using STRPASTHR for more information.

For information on Connecting Windows 95/NT Clients to your AS/400, see Client Access.

User written APPC applications

APPN performs many functions in a communications environment. Therefore, it is important to consider time-out parameters in APPC programs which use ICF. In particular, it may be important to increase the WAITFILE parameter for these applications so that they do not time-out while waiting for APPN functions to be performed.

APPN function is transparent to APPC programs using APPN take advantage of the following routing functions:

vNon-adjacent nodes appear adjacent and so APPC programs may communicate directly to programs in non-adjacent nodes (without any APPC programs on the intermediate nodes).

vPerformance is improved for APPC programs with session endpoints that are not physically adjacent in the network.

vAPPC programs may communicate directly to programs in nodes in an adjacent APPN network through network nodes.

Distributed data management (DDM)

DDM is a function of the operating system that allows an application program or user on one system to use database files stored on remote systems. The systems must be connected by a communications network, and the remote systems must also be using DDM.

DDM on the AS/400 allows application programs or users to:

vAccess data files that reside on remote systems (target systems). The remote systems can also access data files on the local AS/400 system.

vAn application can add, change, and delete data records in a file that exist on a target system.

vCreate, delete, or rename files on a remote system.

vCopy a file from one system to another.

When DDM is in use, neither the application program nor the program user needs to know if the file that is needed exists locally or on a remote system. Remote and local file processing are essentially handled the same way.

Application program interface (API) performance considerations

To achieve better performance with your AS/400, you need to consider the application programming interface (API) available on the AS/400. To optimize APPC performance, consider the following:

© Copyright IBM Corp. 1998, 2001

17

vUsing larger sends for a given large transfer (record sizes) provides a higher application data rate and decreases CPU time. With the larger record size, the CPU has less processing to do because there are fewer application reads and writes to transfer the same amount of data.

vIf a value of *CALC is selected for maximum Systems Network Architecture (SNA) request/response unit (RU), the system selects an efficient size compatible with the frame size. The frame size is on the line description that you choose. Changing the RU size to a value other than *CALC may negate the performance feature.

vCompression with APPC should be used with caution and only for slower speed wide area network (WAN) environments. Many suggest that compression should be used with speeds 19.2 kbps and slower.

vIf you are doing tasks that include repetitive, small puts; better performance is achieved if you use ICF or CPI Communications.

See the following topics for a more complete discussion of APPC applications:

vPerformance considerations for Intersystem Communications Function

vPerformance considerations for Common Programming Interface communications

For information about AS/400 communications, see the Communications Configuration book.

For more information about CICS/400, see the CICS/400 Administration and Operations Guide .

Performance considerations for intersystem communications function

You can use intersystem communications function (ICF) to write application programs that you want to communicate with advanced program-to-program communications (APPC). ICF also provides program-to-device communications between the AS/400 system and hardware devices. You must determine which system is to send data first before you write the program. ICF data management handles the communication functions and the data for your program. In particular, ICF should be used to do tasks that include repetitive, small inputs.

To optimize ICF performance, consider the following:

vEliminate unused record formats.

vUse separate record formats instead of multipurpose record formats with option indicators.

vCode to use the same record format for repeated operations.

vSet the maximum program devices equal to 1.

vUse a nonshared file.

vUse a separate indicator area.

vThe use of the ICF keywords force data and confirm should be minimized.

vUse the Request to Send keyword only when necessary.

vUse the Invite Only keyword when soliciting input from multiple devices, otherwise use the Read keyword instead.

vIf using the Invite keyword to solicit from multiple program devices, follow it with a Read-from-invited operation, not a Read operation.

To create device descriptions to get your system set up for ICF, do the following:

1.Type the appropriate Create Device Description commands on the AS/400 command line and press F4.

2.Use the online help information to choose the parameter values.

3.Press Enter. The device description is created.

For more information about ICF, see

v“Application program interface (API) performance considerations” on page 17

vICF Programming

18 Version 5

Performance considerations for Common Programming Interface Communications

You can use Common Programming Interface Communications (CPI Communications) to write application programs that you want to communicate with advanced program-to-communications (APPC). The interface makes use of the System Network Architecture (SNA) LU (logical unit) 6.2 architecture to do the following:

vEstablish a conversation

vSend and receive data

vExchange control information

vEnd a conversation

vNotify a partner program of errors.

Intersystem communications feature (ICF) and CPI Communications programs have similar performances for small data transfers.

To optimize CPI Communications application programs, do the following:

vMinimize the use of flush and confirm.

vReceive a compile record and parse it in your buffer.

vDo not use multiple receive calls to receive a single record.

vUse Request-to-Send only when necessary.

To add or change communications entries to get the system set up for CPI Communications, do the following:

1. Type appropriate command on the AS/400 command line and press F4.

vAdd Communications Entry (ADDCMNE)

vRemove Communications Entry (RMVCMNE)

vChange Communications Entry (CHGCMNE)

2.Use the online help information to change, add, or remove parameter values.

3.Press Enter. The communications entries are added, changed or removed.

For more information about configuring CPI Communications, see:

v“Application program interface (API) performance considerations” on page 17

vCICS/400 Administration and Operations Guide

Chapter 4. Communications applications 19

20 Version 5

Chapter 5. Communicating with host systems

You can configure the AS/400 system to communicate with a host system by matching AS/400 parameters.

Another option for AS/400 users is Dependent LU Requester Support (DLUR). DLUR allows dependent secondary logical units (LU 0, 1, 2, and 3) an entry point into the APPN network. DLUR support gives the appearance of having an adjacent connection to VTAM, but allows traversing the APPN network through intermediate nodes. To configure DLUR, see the page Configuring Dependent LU Requester (DLUR).

Matching AS/400 parameters for a host system

You can configure the AS/400 system to communicate with a host system. This configuration requires the coordination of parameters and values. The list contains only those configuration prompts and parameters that require coordination on both the AS/400 and the host system. In addition, some of the parameters that are listed may not apply to your particular configuration.

For examples of connecting an AS/400 to a host system, see “Examples: Connecting AS/400 to a host system” on page 26.

For information about configuring host systems, see the manuals VTAM Installation and Resource Definition, SC23-0111, and Network Control Program Resource Definition Reference, SC30-3254.

v“Matching AS/400 line description parameters for a host system”

v“Matching AS/400 controller description parameters for a host system” on page 23

v“Matching AS/400 device description parameters for a host system” on page 24

v“Matching AS/400 mode and class-of-service description parameters for a host system” on page 25

vFor more information on AS/400 parameters, see Communications Configuration .

Matching AS/400 line description parameters for a host system

You must match host system communications configuration parameters with AS/400 values. A description of these AS/400 values are in the following table. For information about configuring host systems, see the manuals VTAM Installation and Resource Definition, SC23-0111, and Network Control Program Resource Definition Reference, SC30-3254.

You can specify some host system parameters on multiple definition statements, such as the GROUP, LINE, PU, and LU. The following table lists only the lowest level definition statement that is used by the host system.

To configure an AS/400 to a host system:

vSee “Examples: Connecting AS/400 to a host system” on page 26 for an example of connecting an AS/400 to a host system.

vUse the following table for the line description parameter.

© Copyright IBM Corp. 1998, 2001

21

 

AS/400

Host Definition

 

AS/400 Prompt

Parameter

Statement

Host Parameter

 

 

 

 

Local adapter address

ADPTADR

PATH

DIALNO

 

 

 

Host DIALNO parameter is a concatenation of:

 

 

 

SSAP/DSAP/remote-adapter-address.

 

 

 

AS/400 CRTLINTRN command ADPTADR value must

 

 

 

match the remote-adapter-address portion of the host

 

 

 

DIALNO parameter. The DSAP portion of the DIALNO

 

 

 

parameter must correspond to the SSAP value

 

 

 

specified on the AS/400 controller description.

 

 

 

 

 

 

PU

MACADDR

 

 

 

For 9370/LAN only, the AS/400 line description

 

 

 

ADPTADR must match the host MACADDR parameter.

 

 

 

MACADDR can be coded as an 8- or 12-digit

 

 

 

hexadecimal number; the 8-digit variation assumes

 

 

 

4000 in the first four positions (4000xxxxxxxx).

 

 

 

 

Connection type

CNN

GROUP

DIAL

 

 

 

If the AS/400 line description CNN parameter is

 

 

 

*SWTPP or *SHM, DIAL=YES must be specified for the

 

 

 

host system; if CNN is *MP or *NONSWTPP, DIAL=NO

 

 

 

must be specified.

 

 

 

If CNN(*MP) is specified, the SERVICE

 

 

 

macroinstruction must be used to specify the sequence

 

 

 

in which stations are served.

 

 

 

 

Exchange identifier

EXCHID

PU

IDBLK, IDNUM

 

 

 

The AS/400 block number (digits 1-3 of the EXCHID) is

 

 

 

always 056. The remaining 5 digits (based on the

 

 

 

system serial number if *SYSGEN is used) are

 

 

 

specified in the IDNUM parameter.

 

 

 

 

Line speed

LINESPEED

LINE

SPEED

 

 

 

Line speeds specified for each system must match.

 

 

 

 

Maximum frame size

MAXFRAME

PU

MAXDATA

 

 

 

Values specified for each system must match.

 

 

 

 

NRZI data encoding

NRZI

LINE

NRZI

 

 

 

Values specified for each system must match.

 

 

 

 

Station address

STNADR

PU

ADDR

 

 

 

AS/400 system station address must be unique within

 

 

 

host PU definitions. (Ignored within 9370/LAN

 

 

 

environment.)

 

 

 

 

For more information on AS/400 parameters, see Communications Configuration .

For steps on how to create a line description, see “Creating a line description” on page 5.

22 Version 5

Matching AS/400 controller description parameters for a host system

You must match host system communications configuration parameters with AS/400 values. A description of the AS/400 values are in the following table. For information about configuring host systems, see the manuals VTAM Installation and Resource Definition, SC23-0111, and Network Control Program Resource Definition Reference, SC30-3254.

You can specify some host system parameters on multiple definition statements, such as the GROUP, LINE, PU, and LU. The following table lists only the lowest level definition statement that is used by the host system.

To configure an AS/400 to a host system:

vSee “Examples: Connecting AS/400 to a host system” on page 26 for an example of connecting an AS/400 to a host system.

vUse the following table for the controller description parameter.

 

AS/400

Host Definition

 

AS/400 Prompt

Parameter

Statement

Host Parameter

 

 

 

 

Adjacent link station

ADJLNKSTN

PU

name

 

 

 

AS/400 adjacent link station name must match the

 

 

 

name assigned to the PU macro instruction in the host

 

 

 

system switched major node definition. This match is

 

 

 

required if AS/400 host controller description specifies

 

 

 

RMTCPNAME(*ANY), SWITCHED(*YES) or

 

 

 

SNBU(*YES), and LINKTYPE is *SDLC or *IDLC.

 

 

 

This parameter should be specified only if the host

 

 

 

system is running VTAM Version 4 Release 1 or later

 

 

 

and NCP Version 6 Release 2 or later.

 

 

 

 

LAN remote adapter

ADPTADR

LINE

LOCADD

address

 

 

Values specified for each system must match. If

 

 

 

 

 

 

LOCADD is specified, ECLTYPE=PHYSICAL must also

 

 

 

be specified on the GROUP definition statement.

 

 

 

 

 

 

PORT

MACADDR

 

 

 

For 9370/LAN only, the AS/400 controller description

 

 

 

ADPTADR must match the host MACADDR parameter.

 

 

 

MACADDR can be coded as an 8- or 12-digit

 

 

 

hexadecimal number; the 8-digit variation assumes 4000

 

 

 

in the first four positions (4000xxxxxxxx).

 

 

 

 

Destination service

DSAP

PORT

SAPADDR

access point

 

 

For 9370/LAN only, the AS/400 controller description

 

 

 

 

 

 

DSAP must match the host SAPADDR parameter.

 

 

 

The SAPADDR parameter is a decimal value (4-252);

 

 

 

the AS/400 value is specified as a 2-digit hexadecimal

 

 

 

number.

 

 

 

 

Local exchange

LCLEXCHID

PU

IDBLK, IDNUM

identifier

 

 

For parallel connections only. Required if the AS/400

 

 

 

 

 

 

system specifies RMTCPNAME(*ANY),

 

 

 

SWITCHED(*YES), and LINKTYPE is *SDLC or *IDLC.

 

 

 

The LCLEXCHID specified must match the values

 

 

 

specified in the switched major node definition PU

 

 

 

macro instruction.

 

 

 

 

Chapter 5. Communicating with host systems 23

 

AS/400

Host Definition

 

AS/400 Prompt

Parameter

Statement

Host Parameter

 

 

 

 

Maximum frame size

MAXFRAME

GROUP

MAXDATA

 

 

 

Values specified for each system must match.

 

 

 

 

Remote control point

RMTCPNAME

VTAMLST

SSCPNAME

name

 

 

Required only if APPN(*YES). AS/400 controller

 

 

 

 

 

 

description value must match SSCPNAME specified in

 

 

 

the Virtual Telecommunications Access Method (VTAM)

 

 

 

start options list (ATCSTRyy).

 

 

 

 

Remote network

RMTNETID

VTAMLST

NETID

identifier

 

 

Required only if APPN(*YES). AS/400 controller

 

 

 

 

 

 

description value must match NETID specified in the

 

 

 

VTAM start options list (ATCSTRyy).

 

 

 

 

Source service access

SSAP

PU

SAPADDR

point

 

 

For 9370/LAN only, the AS/400 controller description

 

 

 

 

 

 

DSAP must match the host SAPADDR parameter.

 

 

 

The SAPADDR parameter is a decimal value (4-252);

 

 

 

the AS/400 value is specified as a 2-digit hexadecimal

 

 

 

number.

 

 

 

 

SSCP identifier

SSCPID

VTAMLST

SSCPID

 

 

 

Required if APPN(*YES) or if RMTCPNAME is not

 

 

 

specified. AS/400 controller description value must

 

 

 

match SSCPID specified in the VTAM start options list

 

 

 

(ATCSTRyy).

 

 

 

The SSCPID parameter is a decimal value (0-65535);

 

 

 

the AS/400 value is specified as a 12-digit hexadecimal

 

 

 

number, of which the first 2 digits are 05.

 

 

 

 

Station address

STNADR

PU

ADDR

 

 

 

AS/400 system station address must be unique within

 

 

 

host PU definitions. Controller description STNADR

 

 

 

must match the value specified in the line description.

 

 

 

 

For more information on AS/400 parameters, see Communications Configuration .

Matching AS/400 device description parameters for a host system

You must match host system communications configuration parameters with AS/400 values. A description of the AS/400 values are in the following table. For information about configuring host systems, see the manuals VTAM Installation and Resource Definition, SC23-0111, and Network Control Program Resource Definition Reference, SC30-3254.

You can specify some host system parameters on multiple definition statements, such as the GROUP, LINE, PU, and LU. The following table lists only the lowest level definition statement that is used by the host system.

To configure an AS/400 to a host system:

vSee “Examples: Connecting AS/400 to a host system” on page 26 for an example of connecting an AS/400 to a host system.

24 Version 5

v Use the following table for the device description parameter.

 

AS/400

Host Definition

 

AS/400 Prompt

Parameter

Statement

Host Parameter

 

 

 

 

Local location name

LCLLOCNAME

DFHTCT

NETNAME

 

 

 

AS/400 LCLLOCNAME value must match CICS/VS

 

 

 

terminal control table NETNAME parameter and the

 

 

 

label used on the LU definition statement.

 

 

 

 

Local location address

LOCADR

LU

LOCADDR

 

 

 

Values specified for each system must match.

 

 

 

The LOCADDR parameter is a decimal value (0-255);

 

 

 

the AS/400 value is specified as a 2-digit hexadecimal

 

 

 

number.

 

 

 

 

Location password

LOCPWD

DFHTCT

BINDPWD

 

 

 

Values specified for each system must match.

 

 

 

 

Dependent location

DEPLOCNAME

LU

LU

name

 

 

This parameter is only used for DLUR support. This

 

 

 

 

 

 

value is optional. If specified, it must match LUNAME

 

 

 

received on ACTLUREQUEST.

 

 

 

 

Mode description

MODE

MODEENT

LOGMODE

name

 

 

AS/400 mode description name must be defined in the

 

 

 

 

 

 

host logon mode table using the LOGMODE parameter

 

 

 

on the MODEENT macro instruction. The mode name

 

 

 

must also be included in the CICS/VS terminal control

 

 

 

table (DFHTCT) MODENAM parameter.

 

 

 

 

Remote location name

RMTLOCNAME

LU

LOGAPPL

 

 

 

Values specified for each system must match.

 

 

 

 

Remote network

RMTNETID

BUILD

NETID

identifier

 

 

Values specified for each system must match.

 

 

 

 

 

 

 

For more information on AS/400 parameters, see Communications Configuration.

Matching AS/400 mode and class-of-service description parameters for a host system

You must match host system communications configuration parameters with AS/400 values. A description of the AS/400 values are in the following table. For information about configuring host systems, see the manuals VTAM Installation and Resource Definition, SC23-0111, and Network Control Program Resource Definition Reference, SC30-3254.

You can specify some host system parameters on multiple definition statements, such as the GROUP, LINE, PU, and LU. The following table lists only the lowest level definition statement that is used by the host system.

To configure an AS/400 to a host system:

vSee “Examples: Connecting AS/400 to a host system” on page 26 for an example of connecting an AS/400 to a host system.

vUse the following table for the mode and class-of-service description parameter.

Chapter 5. Communicating with host systems 25

 

AS/400

Host Definition

 

AS/400 Prompt

Parameter

Statement

Host Parameter

 

 

 

 

Mode description

MODD

MODEENT

LOGMODE

name

 

 

AS/400 mode description name specified on the AS/400

 

 

 

 

 

 

CRTMODD command (MODD parameter) must be

 

 

 

defined in the host logon mode table using the

 

 

 

LOGMODE parameter on the MODEENT macro

 

 

 

instruction. The mode name must also be included in

 

 

 

the CICS/VS terminal control table (DFHTCT)

 

 

 

MODENAM parameter.

 

 

 

 

Class-of-service

COSD

MODEENT

COS

description name

 

 

AS/400 class-of-service description name specified on

 

 

 

 

 

 

the AS/400 Create Class-of-Service Description

 

 

 

(CRTCOSD) command (COSD parameter) and

 

 

 

CRTMODD command (COS parameter) must be

 

 

 

defined in the host logon mode table using the COS

 

 

 

parameter on the MODEENT macro instruction. The

 

 

 

class-of-service description must also be defined in the

 

 

 

VTAM class-of-service table.

 

 

 

 

For more information on AS/400 parameters, see Communications Configuration .

Examples: Connecting AS/400 to a host system

Configuration parameters must be coordinated when you connect an AS/400 system to a host system.

Example 1: AS/400 to host system over a nonswitched SDLC line.

This diagram shows the AS/400 values that need to match the VTAM values when you use a nonswitched SDLC line.

26 Version 5

Example 2: AS/400 to host system over a token-ring line.

This diagram shows the AS/400 values that need to match the VTAM values when you use a token-ring line.

Chapter 5. Communicating with host systems 27

Example 3: AS/400 system for DLUR support with the host system.

28 Version 5

This diagram shows the AS/400 values that need to match the VTAM values when you use AS/400 DLUR and VTAM.

Example 4: AS/400 with APPN connection to VTAM

This diagram shows the AS/400 values that need to match the VTAM values when you connect with APPN.

Chapter 5. Communicating with host systems 29

30 Version 5

Configuring dependent LU requester (DLUR)

Dependent LU Requester (DLUR) allows dependent secondary logical units (LU 0, 1, 2, and 3) an entry point into the APPN network. DLUR support gives the appearance of having an adjacent connection to VTAM, but allows traversing the APPN network through intermediate nodes.

Note: DLUR uses logmode CPSVRMGR. This is created internally as part of the APPN and DLUR support. If CPSVRMGR exists as a user-defined logmode on any of the systems in your network, it must be deleted. Use the Work with Mode Descriptions (WRKMODD) command and specify the option to delete CPSVRMGR.

To configure the AS/400 system to communicate with DLUR, perform these steps:

1.Configure a host controller description

2.Configure device descriptions

3.Verify that an APPN connection into the network exists (host or APPC controller with *YES specified for the APPN parameter).

Configuring the host controller description

Use the Create Controller Description (SNA Host) (CRTCTLHOST) command to create the controller description. If you have already created a controller description for such functions as 3270 emulation or NRF, you must change the link type to *DLUR. Follow these steps:

1.Retrieve the configuration description for the Dependent LU Requester (DLUR) controller description using the Retrieve Configuration Source (RTVCFGSRC) command.

2.Edit the member to change the link type to *DLUR.

3.Convert the source to a CL program.

4.Create the CL program using the CRTCLPGM command.

5.Delete the configuration using the DLTCTLD command.

6.Call the CL program to create the new configuration.

An explanation of some of the fields on the Create Controller Description (SNA Host) (CRTCTLHOST) screen are as follows:

Local exchange identifier

Matches the ID block and ID number parameters from the PU definition on VTAM.

Dependent PU name

Matches the name of the PU specified on the PU definition on VTAM.

Note: If the local exchange identifier and the dependent PU name are specified, both must match the definitions on VTAM. If both parameter values do not match, the ACTPU will be rejected.

If the *DIAL value is specified for the INLCNN parameter, the primary DLUS name (PRIDLUS), and either the local exchange identifier (LCLEXCHID), or the dependent PU name (DEPPUNAME) must be specified.

Control point name and network identifier for the primary DLUS name

Matches the SSCP name and NETID parameters on the VTAM startup options.

For the last step see, Configuring the device descriptions.

Configuring the device descriptions

Use the Create Device Description (CRTDEVDSP) command to create the device.

Dependent location name

Matches the LU name on the LU definition on VTAM.

Chapter 5. Communicating with host systems 31

Note: This must match the VTAM LU name with the corresponding local location address (LOCADDR) on VTAM.

For more information on DLUR see, Dependent LU Requester Support (DLUR).

32 Version 5

Chapter 6. Communicating with a remote AS/400 system

Using advanced program-to-program communications (APPC), you can configure the AS/400 system to communicate with another AS/400 system. This configuration requires the coordination of configuration parameters and values. Only those configuration prompts and parameters that require coordination on both the AS/400, and the remote AS/400 system are listed. In addition, some of the parameters that are listed may not apply to your particular configuration. See the following topics for more information:

v“Matching AS/400 line description parameters for a remote AS/400 system”

v“Matching AS/400 controller description parameters for a remote AS/400 system” on page 35

v“Matching AS/400 device description parameters for a remote AS/400 system” on page 36

For an example of connecting one AS/400 to another AS/400 system, see “Connecting one AS/400 to another AS/400 system” on page 37.

For more information on AS/400 parameters, see the Communications Configuration book.

Matching AS/400 line description parameters for a remote AS/400 system

You must coordinate communications configuration parameters between local and remote AS/400 systems. These parameters are described in the following table. This table shows those prompts and parameters that must be coordinated when you specify line descriptions for the local and remote AS/400 systems.

To configure a local AS/400 to a remote AS/400:

vSee “Connecting one AS/400 to another AS/400 system” on page 37 for an example of connecting one AS/400 to another AS/400 system.

vUse the following table for the line descriptions.

 

AS/400

Remote AS/400

 

AS/400 Prompt

Parameter

Parameter

Notes

 

 

 

 

Local adapter address

ADPTADR

ADPTADR

Adapter address of the local system (specified on the

 

 

 

line description) must be matched at the remote system

 

 

 

in the controller description ADPTADR parameter.

 

 

 

If the AS/400 system uses an Ethernet line through an

 

 

 

8209 LAN Bridge, see ″Appendix C: Local Area Network

 

 

 

Addressing Considerations″ in the Communications

 

 

 

Configurationbook.

 

 

 

 

Insert network

ADRINSERT

ADRINSERT

If X.25 DCE support is specified (X25DCE(*YES) or

address in packets

 

 

X25DCE(*NEG)), ADRINSERT(*YES) should be

 

 

 

specified for both systems.

 

 

 

 

Data bits per

BITSCHAR

BITSCHAR

Values specified for each system must match.

character

 

 

 

 

 

 

 

© Copyright IBM Corp. 1998, 2001

33

 

AS/400

Remote AS/400

 

AS/400 Prompt

Parameter

Parameter

Notes

 

 

 

 

Connection initiation

CNNINIT

CNNINIT

If X.25 DCE support is specified (X25DCE(*YES)) for

 

 

 

either system, CNNINIT(*LOCAL) should also be

 

 

 

specified on that system’s line description. The other

 

 

 

system (with X25DCE(*NO) specified) should specify

 

 

 

CNNINIT(*REMOTE) or CNNINIT(*WAIT).

 

 

 

For switched connections, both systems can also

 

 

 

specify X25DCE(*NEG) to negotiate the Distributed

 

 

 

Computing Environment (DCE) and data terminal

 

 

 

equipment (DTE) roles and CNNINIT(*CALLER) to allow

 

 

 

either system to initiate the connection by making the

 

 

 

call.

 

 

 

See the X25DCE parameter for additional

 

 

 

considerations.

 

 

 

 

Duplex

DUPLEX

DUPLEX

Depending on the type of communications used, the

 

 

 

values specified for the DUPLEX parameters may need

 

 

 

to be coordinated.

 

 

 

 

Ethernet standard

ETHSTD

ETHSTD

Values specified for each system must be coordinated.

 

 

 

Both systems must specify the same standard (*ETHV2

 

 

 

or *IEEE8023) or at least one system must specify

 

 

 

*ALL.

 

 

 

 

Exchange identifier

EXCHID

EXCHID

Remote AS/400 controller description EXCHID must

 

 

 

match the local AS/400 line description EXCHID. The

 

 

 

first three digits of the exchange identifier, known as the

 

 

 

block number, is 056 for the AS/400 line. You can use

 

 

 

the Work with Line Descriptions (WRKLIND) command

 

 

 

to determine this value.

 

 

 

 

Logical channel

LGLCHLE

LGLCHLE

If X.25 DCE support is specified (X25DCE(*YES) or

entries

 

 

X25DCE(*NEG)), logical channel types and channel

 

 

 

numbers must be coordinated. See also the

 

 

 

considerations for the X25DCE parameter.

 

 

 

 

Line speed

LINESPEED

LINESPEED

For asynchronous lines, the line speeds specified for

 

 

 

each system must match.

 

 

 

 

Modulus

MODULUS

MODULUS

If X.25 DCE support is specified (X25DCE(*YES) or

 

 

 

X25DCE(*NEG)), modulus values specified for each

 

 

 

system must match.

 

 

 

The values specified for this parameter should match for

 

 

 

all communications types.

 

 

 

 

Local network address

NETADR

CNNNBR

For switched virtual circuits (SVCs), the NETADR

 

 

 

parameter on the local system line description must

 

 

 

match the CNNNBR parameter on the controller

 

 

 

description for the remote system.

 

 

 

 

NRZI data encoding

NRZI

NRZI

Values specified for each system must match (*YES or

 

 

 

*NO).

 

 

 

 

Data link role

ROLE

ROLE

The value specified for the local system line description

 

 

 

ROLE parameter should match the controller description

 

 

 

ROLE parameter specified at the remote system.

 

 

 

 

Number of stop bits

STOPBITS

STOPBITS

Values specified for each system must match.

 

 

 

 

Switched connection

SWTCNN

SWTCNN

Values specified for each system must be compatible.

type

 

 

(*DIAL or *ANS must not be specified for both systems.)

 

 

 

 

34 Version 5

 

AS/400

Remote AS/400

 

AS/400 Prompt

Parameter

Parameter

Notes

 

 

 

 

X.25 DCE support

X25DCE

X25DCE

If X.25 DCE support is used (X25DCE(*YES)), only one

 

 

 

of the AS/400 line descriptions should specify *YES.

 

 

 

The system specifying X25DCE(*YES) should also

 

 

 

specify CNNINIT(*LOCAL); the other AS/400 system

 

 

 

should specify X25DCE(*NO) and CNNINIT(*REMOTE)

 

 

 

or CNNINIT(*WAIT).

 

 

 

For switched connections, both systems can also

 

 

 

specify X25DCE(*NEG) to negotiate the DCE and DTE

 

 

 

roles, and CNNINIT(*CALLER) to allow either system to

 

 

 

initiate the connection by making the call.

 

 

 

 

For more information on AS/400 parameters, see the Communications Configuration book.

For steps on how to create a line description, see “Creating a line description” on page 5.

Matching AS/400 controller description parameters for a remote AS/400 system

You must coordinate communications configuration parameters between local and remote AS/400 systems. The parameters are described in the following table. This table shows those prompts and parameters that must be coordinated when you specify controller descriptions for the local and remote AS/400 systems.

To configure a local AS/400 to a remote AS/400:

vSee “Connecting one AS/400 to another AS/400 system” on page 37 for an example of connecting one AS/400 to another AS/400 system.

vUse the following table for the controller descriptions.

 

AS/400

Remote AS/400

 

 

AS/400 Prompt

Parameter

Parameter

 

Notes

 

 

 

 

local area network

ADPTADR

ADPTADR

The adapter address specified on the local system

(LAN) remote adapter

 

 

controller description must match the line description

address

 

 

ADPTADR parameter specified by the remote system.

 

 

 

If the AS/400 system uses an Ethernet line through an

 

 

 

8209 LAN Bridge, see ″Appendix C: Local Area Network

 

 

 

Addressing Considerations″ in the Communications

 

 

 

Configuration

book.

 

 

 

 

Connection number

CNNNBR

NETADR

For X.25 switched virtual circuits (SVCs), the CNNNBR

 

 

 

parameter on the local system controller description

 

 

 

must match the NETADR parameter on the line

 

 

 

description for the remote system.

 

 

 

 

Connection password

CNNPWD

CNNPWD

For switched virtual circuits (SVCs), passwords

 

 

 

specified for each system must match.

 

 

 

 

Destination service

DSAP

SSAP

DSAP specified for the local AS/400 system must match

access point

 

 

the SSAP specified in the remote AS/400 controller

 

 

 

description.

 

 

 

 

 

 

Chapter 6. Communicating with a remote AS/400 system 35

 

AS/400

Remote AS/400

 

AS/400 Prompt

Parameter

Parameter

Notes

 

 

 

 

Exchange identifier

EXCHID

EXCHID

If used, the local AS/400 controller description EXCHID

 

 

 

must match the remote AS/400 line description

 

 

 

EXCHID. The first three digits of the exchange identifier,

 

 

 

known as the block number, is 056 for the AS/400 line.

 

 

 

You can use the WRKLIND command to determine this

 

 

 

value.

 

 

 

 

Initial connection

INLCNN

INLCNN

Values specified for each system must be coordinated;

 

 

 

INLCNN(*ANS) must not be specified for both systems.

 

 

 

 

Link protocol

LINKPCL

LINKPCL

For X.25 connections, values specified for each system

 

 

 

must match; both must be *QLLC or *ELLC.

 

 

 

 

Remote control point

RMTCPNAME

LCLCPNAME

RMTCPNAME specified on the local AS/400 system

name

 

 

controller description must match the local control point

 

 

 

name specified in the network attributes of the remote

 

 

 

AS/400 system.

 

 

 

 

Remote network

RMTNETID

LCLNETID

RMTNETID specified on the local AS/400 system

identifier

 

 

controller description must match the local network ID

 

 

 

specified in the network attributes of the remote AS/400

 

 

 

system.

 

 

 

 

Data link role

ROLE

ROLE

The value specified for the local AS/400 controller

 

 

 

description ROLE parameter must match the remote

 

 

 

AS/400 line description ROLE value.

 

 

 

 

X.25 reverse charging

RVSCRG

RVSCRG

Values specified for each system must be coordinated.

 

 

 

 

Switched network

SNBU

SNBU

Values specified for each system must match.

backup

 

 

 

 

 

 

 

Source service access

SSAP

DSAP

SSAP specified for the local AS/400 system must match

point

 

 

the DSAP specified in the remote AS/400 controller

 

 

 

description.

 

 

 

 

Station address

STNADR

STNADR

Values specified for each system must match, unless

 

 

 

both controller descriptions specify ROLE(*NEG).

 

 

 

 

Note: For asynchronous controllers (CRTCTLASC command), if the remote system controller description specifies RMTVFY(*YES), the local system controller description must specify a local identifier (LCLID parameter) and local location name (LCLLOCNAME parameter). The remote system must also create a configuration list with the LCLID and LCLLOCNAME values from the local system controller description.

For more information on AS/400 parameters, see the Communications Configuration book.

Matching AS/400 device description parameters for a remote AS/400 system

You must coordinate communications configuration parameters between local and remote AS/400 systems. The parameters are described in the following table. This table shows those prompts and parameters that must be coordinated when you specify device descriptions for the local and remote AS/400 systems.

To configure a local AS/400 to a remote AS/400:

vSee “Connecting one AS/400 to another AS/400 system” on page 37 for an example of connecting one AS/400 to another AS/400 system.

vUse the following table for the device description.

36 Version 5

 

AS/400

Remote AS/400

 

 

AS/400 Prompt

Parameter

Parameter

 

Notes

 

 

 

 

 

LCLLOCNAME

RMTLOCNAME

For systems not using APPN (APPN(*NO) specified for

 

 

 

the controller and device descriptions), this value must

 

 

 

match the value specified by the RMTLOCNAME

 

 

 

parameter on the remote system device description.

 

 

 

APPC device descriptions are automatically created as

 

 

 

needed by the AS/400 APPN support, when the

 

 

 

following is specified on the controller description:

 

 

 

v

APPN(*YES)

 

 

 

v

AUTOCRTDEV(*ALL)

Location Password

LOCPWD

LOCPWD

This parameter must match on both the local and

 

 

 

remote APPC device.

 

 

 

Note: If you want a value other than *NONE for APPN

 

 

 

devices, this value must be configured on the

 

 

 

QAPPNRMT configuration list.

 

 

 

 

Mode

MODE

MODE

For systems not using APPN (APPN(*NO) specified for

 

 

 

the controller and device descriptions), this value must

 

 

 

match the value specified by the MODE parameter on

 

 

 

the remote device description.

 

 

 

For systems using APPN (APPN(*YES) specified for the

 

 

 

controller and device descriptions), the specified mode

 

 

 

description must exist on the remote system. The mode

 

 

 

description name need not be specified in the remote

 

 

 

device description.

 

 

 

 

Remote location name

RMTLOCNAME

LCLLOCNAME

For systems not using APPN (APPN(*NO) specified for

 

 

 

the controller and device descriptions), this value must

 

 

 

match the value specified by the LCLLOCNAME

 

 

 

parameter on the remote device description.

 

 

 

APPC device descriptions are automatically created as

 

 

 

needed by AS/400 APPN support if APPN(*YES) is

 

 

 

specified for the controller description.

 

 

 

 

 

RMTNETID

LCLNETID

RMTNETID specified on the local AS/400 system device

 

 

 

description must match the local network ID specified in

 

 

 

the network attributes of the remote AS/400 system.

 

 

 

 

Single session

SNGSSN

SNGSSN

For Element 1 ( single-session device description), this

 

 

 

parameter must match on both the local and remote

 

 

 

APPC device.

 

 

 

Note: If you want a value other than *NO for APPN

 

 

 

devices, this value must be configured on the

 

 

 

QAPPNRMT configuration list.For Element 2 (number of

 

 

 

single-session conversations), this parameter does not

 

 

 

need to match the remote device.

 

 

 

 

 

For more information on AS/400 parameters, see the Communications Configuration book.

Connecting one AS/400 to another AS/400 system

Configuration parameters must be coordinated when you specify controller, device, and line descriptions for the local and remote AS/400.

Example 1: AS/400 to AS/400 using X.25

Chapter 6. Communicating with a remote AS/400 system 37

This example shows the matching parameters between an AS/400 connecting to another AS/400 that uses X.25.

Example 2: AS/400 to AS/400 using SDLC

38 Version 5

This example shows the matching parameters between an AS/400 connecting to another AS/400 that uses SDLC.

Example 3: AS/400 to AS/400 using one-way automatic dialing

This example shows the matching parameters between an AS/400 connecting to another AS/400 that uses one-way automatic-dial function.

Chapter 6. Communicating with a remote AS/400 system 39

40 Version 5

Chapter 7. Communicating with remote workstation controllers

You can configure the AS/400 system to communicate with another AS/400 system, a non-AS/400 system, or a remote controller. This configuration requires the coordination of configuration parameters and values.

To configure your AS/400 to communicate with remote workstation controllers, see the following:

v“Matching AS/400 parameters for 5494 controllers”

v“Matching AS/400 parameters for 3x74 controller” on page 58

v“Matching AS/400 parameters for finance controllers” on page 62

v“Matching AS/400 parameters for retail controllers” on page 67

Matching AS/400 parameters for 5494 controllers

You must coordinate the configuration parameters and values to configure the AS/400 system to communicate with a 5494 controller. You can coordinate these values automatically or manually. Pick one of the ways:

vTo automatically connect the AS/400 to a 5494 controller, you can use the automatic remote controller (QAUTORMT) system value.

vTo manually connect the AS/400 to a 5494, you can use the following examples and the tables.

The list contains only those configuration prompts and parameters that require coordination on both AS/400 and the 5494 controller. In addition, some of the parameters that are listed may not apply to your particular configuration.

“Matching AS/400 parameters for a 5494 connected by token-ring”

“Matching AS/400 parameters for a 5494 connected by Ethernet” on page 44

“Matching AS/400 parameters for a 5494 connected by frame relay” on page 46

“Matching AS/400 parameters for a 5494 connected by SDLC” on page 48

“Matching AS/400 parameters for a 5494 connected by X.21” on page 52

“Matching AS/400 parameters for a 5494 connected by X.25” on page 54

For more information about configuring the 5494, see these books:

vIBM 5494 Remote Control Unit Planning Guide, GA27-3936

vIBM 5494 Remote Control Unit User’s Guide, GA27-3852

vRemote Work Station Support .

Matching AS/400 parameters for a 5494 connected by token-ring

You must coordinate communications configuration parameters between AS/400 and the 5494 controller that is connected by token-ring. You can coordinate these values automatically or manually. Pick one of these ways:

vTo automatically connect the AS/400 to a 5494 controller, you can use the automatic remote controller (QAUTORMT) system value.

vTo manually connect the AS/400 to a 5494:

See “Example: Connecting AS/400 to a 5494 controller connected by token-ring” on page 43 for an example of connecting AS/400 to a 5494 controller by token-ring.

Use the following table to configure the AS/400 to a 5494 controller that is connected by token-ring.

The following table gives a description of the parameters . The related fields and subfields from the 5494 configuration display, the AS/400 configuration value, and the matching 5494 value to enter are shown.

For more information about configuring the 5494, see these books:

vIBM 5494 Remote Control Unit Planning Guide, GA27-3936,

vIBM 5494 Remote Control Unit User’s Guide, GA27-3852

© Copyright IBM Corp. 1998, 2001

41

AS/400

 

 

5494

AS/400

 

 

 

 

 

 

 

Prompt

AS/400 Parameter

Field

Subfield

Value

5494 Value

Notes

 

 

 

 

 

 

 

Local

ADPTADR

H1

5

-

-

Values specified in the AS/400

adapter

 

 

 

 

 

line description (CRTLINTRN

address

 

 

 

 

 

command) and for the 5494

 

 

 

 

 

 

Remote Controller Unit must

 

 

 

 

 

 

match.

 

 

 

 

 

 

 

local area

ADPTADR

15

-

-

-

Values specified for the AS/400

network

 

 

 

 

 

CRTCTLAPPC command and

(LAN)

 

 

 

 

 

for the 5494 Remote Control

remote

 

 

 

 

 

Unit must match.

adapter

 

 

 

 

 

 

address

 

 

 

 

 

 

 

 

 

 

 

 

 

Destination

(DSAP)

F

-

-

-

Values specified for the AS/400

service

 

 

 

 

 

CRTCTLAPPC command and

access

 

 

 

 

 

for the 5494 Remote Control

point

 

 

 

 

 

Unit must match.

 

 

 

 

 

 

 

Local

LCLLOCNAME

H1

1

-

-

Values specified for the AS/400

location

 

 

 

 

 

CRTCTLRWS command and for

name

 

 

 

 

 

the 5494 Remote Control Unit

 

 

 

 

 

 

must match. This will probably

 

 

 

 

 

 

match LCLLOCNAME in the

 

 

 

 

 

 

network attributes. This value

 

 

 

 

 

 

will probably match the

 

 

 

 

 

 

LCLLOCNAME in the network

 

 

 

 

 

 

attributes.

 

 

 

 

 

 

 

Remote

RMTCPNAME

13

-

-

-

Values specified for the AS/400

control

 

 

 

 

 

CRTCTLAPPC command and

point name

 

 

 

 

 

for the 5494 Remote Control

 

 

 

 

 

 

Unit must match.

 

 

 

 

 

 

 

Remote

RMTNETID

11

3

-

-

Values specified for the AS/400

network

 

 

 

 

 

CRTCTLAPPC and

identifier

 

 

 

 

 

CRTCTLRWS commands and

 

 

 

 

 

 

for the 5494 Remote Control

 

 

 

 

 

 

Unit must match. This will

 

 

 

 

 

 

probably match LCLNETID in

 

 

 

 

 

 

the network attributes and H1:2.

 

 

 

 

 

 

 

Remote

RMTLOCNAME

12

-

-

-

Values specified for the AS/400

location

 

 

 

 

 

CRTCTLRWS command and for

name

 

 

 

 

 

the 5494 Remote Control Unit

 

 

 

 

 

 

must match.

 

 

 

 

 

 

 

42 Version 5

AS/400

 

 

5494

AS/400

 

 

 

 

 

 

 

Prompt

AS/400 Parameter

Field

Subfield

Value

5494 Value

Notes

 

 

 

 

 

 

 

Link type

LINKTYPE

AA

-

*LAN

4

5494 configuration values must

 

 

 

 

 

 

match the values specified for

 

 

 

 

 

 

the LINKTYPE parameter on the

 

 

 

 

 

 

CRTCTLAPPC command. For

 

 

 

 

 

 

advanced program-to-program

 

 

 

 

 

 

communications (APPC)

 

 

 

 

 

 

controllers that specify

 

 

 

 

 

 

LINKTYPE(*SDLC), the value

 

 

 

 

 

 

specified in the 5494

 

 

 

 

 

 

configuration must be

 

 

 

 

 

 

compatible with the physical

 

 

 

 

 

 

interface (INTERFACE

 

 

 

 

 

 

parameter) specified on the

 

 

 

 

 

 

CRTLINSDLC command.

 

 

 

 

 

 

Select 4 for the network

 

 

 

 

 

 

connections.

 

 

 

 

 

 

 

Example: Connecting AS/400 to a 5494 controller connected by token-ring

Configuration parameters must be coordinated when you connect an AS/400 system to a 5494 controller that is connected by token-ring.

The following diagram shows the AS/400 parameters and 5494 parameters that need to match when you use token-ring.

Chapter 7. Communicating with remote workstation controllers 43

Matching AS/400 parameters for a 5494 connected by Ethernet

You must coordinate communications configuration parameters between AS/400 and the 5494 controller that is connected by Ethernet. A description of these parameters are in the following table. Then the related fields and subfields from the 5494 configuration display, and the AS/400 configuration value and the matching 5494 value entered in the display subfield. You can coordinate these values manually or automatically. Pick one of these ways:

44 Version 5

vTo automatically connect the AS/400 to a 5494 controller, you can use the automatic remote controller (QAUTORMT) system value.

vTo manually connect the AS/400 to a 5494 controller:

See “Example: Connecting AS/400 to a 5494 controller connected by Ethernet” for an example of connecting AS/400 to a 5494 controller by Ethernet.

Use the following table to configure the AS/400 to a 5494 controller that is connected by Ethernet.

For more information about configuring the 5494, see these books:

vIBM 5494 Remote Control Unit Planning Guide, GA27-3936

vIBM 5494 Remote Control Unit User’s Guide, GA27-3852

AS/400

AS/400

 

5494

 

AS/400

 

 

 

 

 

 

 

 

Prompt

Parameter

Field

 

Subfield

 

Value

5494 Value

Notes

 

 

 

 

 

 

 

 

 

Local

ADPTADR

H1

 

5

-

 

-

Values specified in the AS/400 line

adapter

 

 

 

 

 

 

 

description (CRTLINTRN command)

address

 

 

 

 

 

 

 

and for the 5494 Remote Controller

 

 

 

 

 

 

 

 

Unit must match.

 

 

 

 

 

 

 

 

 

LAN remote

ADPTADR

15

 

-

-

 

-

Values specified for the AS/400

adapter

 

 

 

 

 

 

 

CRTCTLAPPC command and for

address

 

 

 

 

 

 

 

the 5494 Remote Control Unit must

 

 

 

 

 

 

 

 

match.

 

 

 

 

 

 

 

 

 

Local

LCLLOCNAME

H1

 

1

-

 

-

Values specified for the AS/400

location

 

 

 

 

 

 

 

CRTCTLRWS command and for the

name

 

 

 

 

 

 

 

5494 Remote Control Unit must

 

 

 

 

 

 

 

 

match. This will probably match

 

 

 

 

 

 

 

 

LCLLOCNAME in the network

 

 

 

 

 

 

 

 

attributes. This value will probably

 

 

 

 

 

 

 

 

match the LCLLOCNAME in the

 

 

 

 

 

 

 

 

network attributes.

 

 

 

 

 

 

 

 

 

Remote

RMTCPNAME

13

 

-

-

 

-

Values specified for the AS/400

control

 

 

 

 

 

 

 

CRTCTLAPPC command and for

point name

 

 

 

 

 

 

 

the 5494 Remote Control Unit must

 

 

 

 

 

 

 

 

match.

 

 

 

 

 

 

 

 

 

Remote

RMTNETID

11

 

3

-

 

-

Values specified for the AS/400

network

 

 

 

 

 

 

 

CRTCTLAPPC and CRTCTLRWS

identifier

 

 

 

 

 

 

 

commands and for the 5494

 

 

 

 

 

 

 

 

Remote Control Unit must match.

 

 

 

 

 

 

 

 

This will probably match LCLNETID

 

 

 

 

 

 

 

 

in the network attributes and H1:2.

 

 

 

 

 

 

 

 

 

Remote

RMTLOCNAME

12

 

-

-

 

-

Values specified for the AS/400

location

 

 

 

 

 

 

 

CRTCTLRWS command and for the

name

 

 

 

 

 

 

 

5494 Remote Control Unit must

 

 

 

 

 

 

 

 

match.

 

 

 

 

 

 

 

 

 

Example: Connecting AS/400 to a 5494 controller connected by Ethernet

Configuration parameters must be coordinated when you connect an AS/400 system to a 5494 controller.

Example: AS/400 to 5494 controller that is connected by Ethernet

The following diagram shows the AS/400 parameters and 5494 parameters that need to match when you use Ethernet.

Chapter 7. Communicating with remote workstation controllers 45

Matching AS/400 parameters for a 5494 connected by frame relay

You must coordinate the communications configuration parameters between AS/400 and the 5494 controller connected by frame relay. A description of the parameters are in the following table. Then, related fields and subfields from the 5494 configuration display and the AS/400 configuration value and the matching 5494 value. You can coordinate these values automatically or manually. Pick one of these ways:

vTo automatically connect the AS/400 to a 5494 controller, you can use the automatic remote controller (QAUTORMT) system value.

vTo manually configure the AS/400 to a 5494 controller:

See “Example: Connecting an AS/400 to a 5494 controller connected by frame relay” on page 47 for an example of connecting AS/400 to a 5494 controller by frame relay.

Use the following table to configure the AS/400 to a 5494 that is connected by frame relay.

For more information about configuring the 5494, see these books:

46 Version 5

vIBM 5494 Remote Control Unit Planning Guide, GA27-3936

vIBM 5494 Remote Control Unit User’s Guide, GA27-3852

AS/400

 

 

5494

AS/400

 

 

 

 

 

 

 

Prompt

AS/400 Parameter

Field

Subfield

Value

5494 Value

Notes

 

 

 

 

 

 

 

Local

ADPTADR

H1

5

-

-

Values specified in the AS/400

adapter

 

 

 

 

 

line description (CRTLINTRN

address

 

 

 

 

 

command) and for the 5494

 

 

 

 

 

 

Remote Controller Unit must

 

 

 

 

 

 

match.

 

 

 

 

 

 

 

LAN

ADPTADR

15

-

-

-

Values specified for the AS/400

remote

 

 

 

 

 

CRTCTLAPPC command and

adapter

 

 

 

 

 

for the 5494 Remote Control

address

 

 

 

 

 

Unit must match.

 

 

 

 

 

 

 

Local

LCLLOCNAME

H1

1

-

-

Values specified for the AS/400

location

 

 

 

 

 

CRTCTLRWS command and

name

 

 

 

 

 

for the 5494 Remote Control

 

 

 

 

 

 

Unit must match. This will

 

 

 

 

 

 

probably match LCLLOCNAME

 

 

 

 

 

 

in the network attributes. This

 

 

 

 

 

 

value will probably match the

 

 

 

 

 

 

LCLLOCNAME in the network

 

 

 

 

 

 

attributes.

 

 

 

 

 

 

 

Link type

LINKTYPE

AA

-

*LAN

4

5494 configuration values must

 

 

 

 

 

 

match the values specified for

 

 

 

 

 

 

the LINKTYPE parameter on

 

 

 

 

 

 

the CRTCTLAPPC command.

 

 

 

 

 

 

For APPC controllers that

 

 

 

 

 

 

specify LINKTYPE(*SDLC), the

 

 

 

 

 

 

value specified in the 5494

 

 

 

 

 

 

configuration must be

 

 

 

 

 

 

compatible with the physical

 

 

 

 

 

 

interface (INTERFACE

 

 

 

 

 

 

parameter) specified on the

 

 

 

 

 

 

CRTLINSDLC command.

 

 

 

 

 

 

Select 4 for the network

 

 

 

 

 

 

connections.

 

 

 

 

 

 

 

Remote

RMTCPNAME

13

-

-

-

Values specified for the AS/400

control

 

 

 

 

 

CRTCTLAPPC command and

point name

 

 

 

 

 

for the 5494 Remote Control

 

 

 

 

 

 

Unit must match.

 

 

 

 

 

 

 

Remote

RMTNETID

11

3

-

-

Values specified for the AS/400

network

 

 

 

 

 

CRTCTLAPPC and

identifier

 

 

 

 

 

CRTCTLRWS commands and

 

 

 

 

 

 

for the 5494 Remote Control

 

 

 

 

 

 

Unit must match. This will

 

 

 

 

 

 

probably match LCLNETID in

 

 

 

 

 

 

the network attributes and

 

 

 

 

 

 

H1:2.

 

 

 

 

 

 

 

Remote

RMTLOCNAME

12

-

-

-

Values specified for the AS/400

location

 

 

 

 

 

CRTCTLRWS command and

name

 

 

 

 

 

for the 5494 Remote Control

 

 

 

 

 

 

Unit must match.

 

 

 

 

 

 

 

Example: Connecting an AS/400 to a 5494 controller connected by frame relay

Configuration parameters must be coordinated when you connect an AS/400 system to a 5494 controller.

Chapter 7. Communicating with remote workstation controllers 47

The following diagram shows the AS/400 parameters and 5494 parameters that need to match when you use frame relay.

Matching AS/400 parameters for a 5494 connected by SDLC

You must coordinate communications configuration parameters between AS/400 and the 5494 controller that is connected by SDLC. These parameters are described in the following table. Then the related fields and subfields from the 5494 configuration display are listed next. These values are followed by the AS/400 configuration value and the matching 5494 value to be entered in the display subfield. You can coordinate these values automatically or manually. Pick one of these ways:

vTo automatically connect the AS/400 to a 5494 controller, you can use the automatic remote controller (QAUTORMT) system value.

vTo manually connect the AS/400 to a 5494 controller:

See “Example: Connecting AS/400 to a 5494 controller connected by SDLC” on page 50 for an example of connecting AS/400 to a 5494 controller by SDLC

Use the following table to configure the AS/400 connected by SDLC.

48 Version 5

For more information about configuring the 5494, see these books:

vIBM 5494 Remote Control Unit Planning Guide, GA27-3936

vIBM 5494 Remote Control Unit User’s Guide, GA27-3852

AS/400

AS/400

 

5494

 

 

 

 

 

 

 

 

Prompt

Parameter

Field

Subfield

AS/400 Value

5494 Value

Notes

 

 

 

 

 

 

 

Connection

CNN

3

1

*NONSWTPP

0

 

type

 

 

 

*MP

 

 

 

 

 

 

 

 

 

 

 

 

 

*SWTPP

1

 

 

 

 

 

 

 

 

 

 

 

3

*MP

0

 

 

 

 

 

 

 

 

 

 

 

 

*NONSWTPP

1

 

 

 

 

 

*SWTPP

 

 

 

 

 

 

 

 

 

Duplex

Duplex

3

2

*HALF

0

 

 

 

 

 

 

 

 

 

 

 

 

*FULL

1

 

 

 

 

 

 

 

 

NRZI data

NRZI

3

4

*YES

0

 

encoding

 

 

 

 

 

 

 

 

 

*NO

1

 

 

 

 

 

 

 

 

 

 

 

 

 

Local

LCLLOCNAME

H1

1

-

-

Values specified for the AS/400

location

 

 

 

 

 

CRTCTLRWS command and

name

 

 

 

 

 

for the 5494 Remote Control

 

 

 

 

 

 

Unit must match. This will

 

 

 

 

 

 

probably match LCLLOCNAME

 

 

 

 

 

 

in the network attributes. This

 

 

 

 

 

 

value will probably match the

 

 

 

 

 

 

LCLLOCNAME in the network

 

 

 

 

 

 

attributes.

 

 

 

 

 

 

 

Link type

LINKTYPE

AA

-

*SDLC

0,2,3

5494 configuration values must

 

 

 

 

 

 

match the values specified for

 

 

 

 

 

 

the LINKTYPE parameter on

 

 

 

 

 

 

the CRTCTLAPPC command.

 

 

 

 

 

 

For APPC controllers that

 

 

 

 

 

 

specify LINKTYPE(*SDLC), the

 

 

 

 

 

 

value specified in the 5494

 

 

 

 

 

 

configuration must be

 

 

 

 

 

 

compatible with the physical

 

 

 

 

 

 

interface (INTERFACE

 

 

 

 

 

 

parameter) specified on the

 

 

 

 

 

 

CRTLINSDLC command.

 

 

 

 

 

 

Select 0 for communications

 

 

 

 

 

 

using SDLC lines other than

 

 

 

 

 

 

X.21 connections.

 

 

 

 

 

 

 

Remote

RMTCPNAME

13

-

-

-

Values specified for the AS/400

control

 

 

 

 

 

CRTCTLAPPC command and

point name

 

 

 

 

 

for the 5494 Remote Control

 

 

 

 

 

 

Unit must match.

 

 

 

 

 

 

 

Remote

RMTNETID

11

3

-

-

Values specified for the AS/400

network

 

 

 

 

 

CRTCTLAPPC and

identifier

 

 

 

 

 

CRTCTLRWS commands and

 

 

 

 

 

 

for the 5494 Remote Control

 

 

 

 

 

 

Unit must match. This will

 

 

 

 

 

 

probably match LCLNETID in

 

 

 

 

 

 

the network attributes and H1:2.

 

 

 

 

 

 

 

Chapter 7. Communicating with remote workstation controllers 49

AS/400

AS/400

 

5494

 

 

 

 

 

 

 

 

Prompt

Parameter

Field

Subfield

AS/400 Value

5494 Value

Notes

 

 

 

 

 

 

 

Remote

RMTLOCNAME

12

-

-

-

Values specified for the AS/400

location

 

 

 

 

 

CRTCTLRWS command and

name

 

 

 

 

 

for the 5494 Remote Control

 

 

 

 

 

 

Unit must match.

 

 

 

 

 

 

 

Station

STNADR

2

-

-

-

Values specified in the AS/400

address

 

 

 

 

 

controller description and for

 

 

 

 

 

 

the 5494 Remote Control Unit

 

 

 

 

 

 

must match. This value must

 

 

 

 

 

 

also be specified as the last 2

 

 

 

 

 

 

digits of the AS/400 EXCHID

 

 

 

 

 

 

parameter.

 

 

 

 

 

 

 

Example: Connecting AS/400 to a 5494 controller connected by SDLC

Configuration parameters must be coordinated when you connect an AS/400 system to a 5494 controller.

The following diagram shows the AS/400 parameters and 5494 parameters that need to match when you use SDLC.

50 Version 5

Chapter 7. Communicating with remote workstation controllers 51

Matching AS/400 parameters for a 5494 connected by X.21

You must coordinate communications configuration parameters between AS/400 and the 5494 remote controller that is connected by X.21. These parameters are described in the following table. Then the related fields and subfields from the 5494 configuration display are listed next. These values are followed by the AS/400 configuration value and the matching 5494 value to be entered in the display subfield. You can coordinate these values automatically or manually. Pick one of these ways:

vTo automatically connect the AS/400 to a 5494 controller, you can use the automatic remote controller (QAUTORMT) system value.

vTo manually connect the AS/400 to a 5494 controller:

See “Example: Connecting AS/400 to a 5494 controller connected by X.21” on page 53 for an example of connecting AS/400 to a 5494 controller by X.21.

Use the following table to configure the AS/400 to a 5494 controller by X.21.

For more information about configuring the 5494, see these books:

vIBM 5494 Remote Control Unit Planning Guide, GA27-3936

vIBM 5494 Remote Control Unit User’s Guide, GA27-3852,

AS/400

AS/400

 

5494

 

 

 

 

 

 

 

 

Prompt

Parameter

Field

Subfield

AS/400 Value

5494 Value

Notes

 

 

 

 

 

 

 

Connection

CNNNBR

15

-

-

-

Values specified for the AS/400

number

 

 

 

 

 

 

 

 

 

 

 

CRTCTLAPPC command and

 

 

 

 

 

 

for the 5494 Remote Control

 

 

 

 

 

 

Unit must match. If the AS/400

 

 

 

 

 

 

CRTCTLAPPC command

 

 

 

 

 

 

specifies CNNNBR(*DC), the

 

 

 

 

 

 

X.21 direct-call user facility

 

 

 

 

 

 

must be used to make the

 

 

 

 

 

 

connection.

 

 

 

 

 

 

 

Local

LCLLOCNAME

H1

1

-

-

Values specified for the AS/400

location

 

 

 

 

 

CRTCTLRWS command and

name

 

 

 

 

 

for the 5494 Remote Control

 

 

 

 

 

 

Unit must match. This will

 

 

 

 

 

 

probably match LCLLOCNAME

 

 

 

 

 

 

in the network attributes. This

 

 

 

 

 

 

value will probably match the

 

 

 

 

 

 

LCLLOCNAME in the network

 

 

 

 

 

 

attributes.

 

 

 

 

 

 

 

Remote

RMTCPNAME

13

-

-

-

Values specified for the AS/400

control

 

 

 

 

 

CRTCTLAPPC command and

point name

 

 

 

 

 

for the 5494 Remote Control

 

 

 

 

 

 

Unit must match.

 

 

 

 

 

 

 

Remote

RMTNETID

11

3

-

-

Values specified for the AS/400

network

 

 

 

 

 

CRTCTLAPPC and

identifier

 

 

 

 

 

CRTCTLRWS commands and

 

 

 

 

 

 

for the 5494 Remote Control

 

 

 

 

 

 

Unit must match. This will

 

 

 

 

 

 

probably match LCLNETID in

 

 

 

 

 

 

the network attributes and H1:2.

 

 

 

 

 

 

 

Remote

RMTLOCNAME

12

-

-

-

Values specified for the AS/400

location

 

 

 

 

 

CRTCTLRWS command and

name

 

 

 

 

 

for the 5494 Remote Control

 

 

 

 

 

 

Unit must match.

 

 

 

 

 

 

 

52 Version 5

AS/400

AS/400

 

5494

 

 

 

 

 

 

 

 

Prompt

Parameter

Field

Subfield

AS/400 Value

5494 Value

Notes

 

 

 

 

 

 

 

Link type

LINKTYPE

AA

-

*X21

4

5494 configuration values must

 

 

 

 

 

 

match the values specified for

 

 

 

 

 

 

the LINKTYPE parameter on

 

 

 

 

 

 

the CRTCTLAPPC command.

 

 

 

 

 

 

Select 2 for X.21 network

 

 

 

 

 

 

connections.

 

 

 

 

 

 

 

Station

STNADR

2

-

-

-

Values specified in the AS/400

address

 

 

 

 

 

controller description and for

 

 

 

 

 

 

the 5494 Remote Control Unit

 

 

 

 

 

 

must match. This value must

 

 

 

 

 

 

also be specified as the last 2

 

 

 

 

 

 

digits of the AS/400 EXCHID

 

 

 

 

 

 

parameter.

 

 

 

 

 

 

 

Example: Connecting AS/400 to a 5494 controller connected by X.21

Configuration parameters must be coordinated when you connect an AS/400 system to a 5494 controller.

The following diagram shows the AS/400 parameters and 5494 parameters that need to match when you use X.21.

Chapter 7. Communicating with remote workstation controllers 53

Matching AS/400 parameters for a 5494 connected by X.25

You must coordinate communications configuration parameters between the AS/400 and the 5494 controller that is connected by X.25. These parameters are described in the following table. Then the related fields and subfields from the 5494 configuration display are listed next. These values are followed by the AS/400 configuration value and the matching 5494 value to be entered in the display subfield. You can coordinate these values automatically or manually. Pick one of these ways:

vTo automatically connect the AS/400 to a 5494 controller, you can use the automatic remote controller (QAUTORMT) system value.

vTo manually connect the AS/400 to a 5494 controller:

See “Example: Connecting AS/400 to a 5494 controller connected by X.25” on page 56 for an example of connecting AS/400 to a 5494 controller by X.25.

Use the following table to connect an AS/400 to a 5494 controller that is connected by X.25.

For more information about configuring the 5494, see these books: v IBM 5494 Remote Control Unit Planning Guide, GA27-3936

54 Version 5

v IBM 5494 Remote Control Unit User’s Guide, GA27-3852

AS/400

AS/400

 

5494

AS/400

 

 

 

 

 

 

 

Prompt

Parameter

Field

 

Subfield

Value

5494 Value

Notes

 

 

 

 

 

 

 

 

Default

DFTPKTSIZE

5

 

1

64

0

 

packet size

 

 

 

 

 

 

 

 

 

 

 

128

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

256

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

512

3

 

 

 

 

 

 

 

 

 

Local

LCLLOCNAME

H1

 

1

-

-

Values specified for the AS/400

location

 

 

 

 

 

 

CRTCTLRWS command and for the

name

 

 

 

 

 

 

5494 Remote Control Unit must

 

 

 

 

 

 

 

match. This will probably match

 

 

 

 

 

 

 

LCLLOCNAME in the network

 

 

 

 

 

 

 

attributes. This value will probably

 

 

 

 

 

 

 

match the LCLLOCNAME in the

 

 

 

 

 

 

 

network attributes.

 

 

 

 

 

 

 

 

X.25 link

LINKPCL

6

 

2

*QLLC

01

 

protocol

 

 

 

 

 

 

 

 

 

 

 

*ELLC

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Link type

LINKTYPE

AA

 

-

*X25

1

5494 configuration values must

 

 

 

 

 

 

 

match the values specified for the

 

 

 

 

 

 

 

LINKTYPE parameter on the

 

 

 

 

 

 

 

CRTCTLAPPC command. For

 

 

 

 

 

 

 

APPC controllers that specify

 

 

 

 

 

 

 

LINKTYPE(*SDLC), the value

 

 

 

 

 

 

 

specified in the 5494 configuration

 

 

 

 

 

 

 

must be compatible with the

 

 

 

 

 

 

 

physical interface (INTERFACE

 

 

 

 

 

 

 

parameter) specified on the

 

 

 

 

 

 

 

CRTLINSDLC command.

 

 

 

 

 

 

 

Select 1 for communications using

 

 

 

 

 

 

 

X.25 lines.

 

 

 

 

 

 

 

 

X.25

NETLVL

6

 

5

1988

0

Used for X.25 communications only.

network

 

 

 

 

 

 

 

 

 

 

 

1984

1

 

level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1980

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote

RMTCPNAME

13

 

-

-

-

Values specified for the AS/400

control

 

 

 

 

 

 

CRTCTLAPPC command and for

point name

 

 

 

 

 

 

the 5494 Remote Control Unit must

 

 

 

 

 

 

 

match.

 

 

 

 

 

 

 

 

Remote

RMTNETID

11

 

3

-

-

Values specified for the AS/400

network

 

 

 

 

 

 

CRTCTLAPPC and CRTCTLRWS

identifier

 

 

 

 

 

 

commands and for the 5494

 

 

 

 

 

 

 

Remote Control Unit must match.

 

 

 

 

 

 

 

This will probably match LCLNETID

 

 

 

 

 

 

 

in the network attributes and H1:2.

 

 

 

 

 

 

 

 

Remote

RMTLOCNAME

12

 

-

-

-

Values specified for the AS/400

location

 

 

 

 

 

 

CRTCTLRWS command and for the

name

 

 

 

 

 

 

5494 Remote Control Unit must

 

 

 

 

 

 

 

match.

 

 

 

 

 

 

 

 

Chapter 7. Communicating with remote workstation controllers 55

AS/400

AS/400

 

5494

AS/400

 

 

 

 

 

 

 

Prompt

Parameter

Field

 

Subfield

Value

5494 Value

Notes

 

 

 

 

 

 

 

 

Station

STNADR

2

 

-

-

-

Values specified in the AS/400

address

 

 

 

 

 

 

controller description and for the

 

 

 

 

 

 

 

5494 Remote Control Unit must

 

 

 

 

 

 

 

match. This value must also be

 

 

 

 

 

 

 

specified as the last 2 digits of the

 

 

 

 

 

 

 

AS/400 EXCHID parameter.

 

 

 

 

 

 

 

 

Example: Connecting AS/400 to a 5494 controller connected by X.25

Configuration parameters must be coordinated when you connect an AS/400 system to a 5494 controller.

The following diagram shows the AS/400 parameters and 5494 parameters that need to match when you use X.25.

56 Version 5

Chapter 7. Communicating with remote workstation controllers 57

Matching AS/400 parameters for 3x74 controller

You must match the AS/400 configuration parameters with some configuration questions and sequence numbers when you configure the 3174 and 3274 controllers.

For an example of connecting an AS/400 to a 3174 retail controller, see “Example: Connecting an AS/400 to a 3174 control unit” on page 61.

v“Matching AS/400 parameters for a 3174 controller”

v“Matching AS/400 parameters for a 3274 controller” on page 60

Matching AS/400 parameters for a 3174 controller

You must match the AS/400 configuration parameters with the configuration questions and sequence numbers to configure the 3174 controller. These parameters are described in the following table.

For more information about configuring the 3174 controllers, see these books:

v3174 Subsystem Control Unit Customizing Guide

v3174 Establishment Controller Supplemental Customer Information for Configuration Support C Release 4 Ethernet Attachment, GA27-3994 has information about Ethernet support.

To configure the AS/400 to a 3174 controller:

vSee “Example: Connecting an AS/400 to a 3174 control unit” on page 61 for an example of connecting an AS/400 to a 3174 retail controller.

vUse the following table to connect an AS/400 to a 3174 remote controller.

 

 

3174

 

 

AS/400

AS/400

Configuration

 

 

Prompt

Parameter

Questions

Notes

 

 

 

 

 

 

LAN remote

ADPTADR

084, 106

Ethernet Address

 

adapter

 

 

If the AS/400 system uses an Ethernet line to connect to the

address1

 

 

 

 

 

3174 controller, use table C-3 on page C-4 in ″Appendix C:

 

 

 

Local Area Network Addressing Considerations″ of the

 

 

 

Communications Configuration

book to convert the

 

 

 

value specified for question 084. Specify the converted

 

 

 

address for the ADPTADR parameter on the CRTCTLRWS

 

 

 

or CRTCTLAPPC command.

 

 

 

 

Token-Ring Network Address of the 3174

 

 

 

If the AS/400 system uses a Token-Ring network line to

 

 

 

connect to the 3174 controller, values specified for question

 

 

 

106 and for the ADPTADR parameter on the CRTCTLRWS

 

 

 

or CRTCTLAPPC command must match.

 

 

 

If the AS/400 system uses an Ethernet line through an 8209

 

 

 

LAN Bridge, see ″Appendix C: Local Area Network

 

 

 

Addressing Considerations″ in the Communications

 

 

 

Configuration book.

 

 

 

 

 

 

58 Version 5

 

 

3174

 

AS/400

AS/400

Configuration

 

Prompt

Parameter

Questions

Notes

 

 

 

 

Local adapter

ADPTADR

107

Token-Ring Network Address of the Gateway

address

 

 

If the AS/400 system uses a Token-Ring network line to

 

 

 

 

 

 

connect to the 3174 controller, values specified for question

 

 

 

107 and for the ADPTADR parameter on the CRTLINTRN

 

 

 

command must match.

 

 

 

If the AS/400 system uses an Ethernet line through an 8209

 

 

 

LAN Bridge, see ″Appendix C: Local Area Network

 

 

 

Addressing Considerations″ in the Communications

 

 

 

Configuration book, for information about specifying the

 

 

 

ADPTADR parameter on the CRTLINETH command.

 

 

 

 

Connection

CNNNBR

423

Host DTE Address (HNAD)

number

 

 

For X.25 lines, the numbers specified on the CRTLINX25

 

 

 

 

 

 

command and in question 423 must match.

 

 

 

 

 

 

368

X.21 Switched Short-Hold Mode Dial Number

 

 

 

For X.21 short-hold mode connections, the numbers

 

 

 

specified on the CRTCTLRWS command and in question

 

 

 

368 must match.

 

 

 

 

 

 

424

3174 DTE Address

 

 

 

For X.25 SVCs, the connection number specified on the

 

 

 

CRTCTLRWS command and in question 424 must match.

 

 

 

 

Destination

DSAP

940

Ring Address Assignment

service access

 

 

The value specified for the DSAP parameter on the

point

 

 

 

 

 

CRTCTLRWS command must match the SAP@ specified for

 

 

 

the 3174 on the Ring Address Assignment display. Used for

 

 

 

token-ring only.

 

 

 

 

Exchange

EXCHID

215

Physical Unit Identification

identifier

 

 

For switched connections, the 5-digit hexadecimal value

 

 

 

 

 

 

specified for question 215 must match the last 5 digits of the

 

 

 

exchange identifier specified on the CRTCTLRWS

 

 

 

command.

 

 

 

 

Link type

LINKTYPE

101

Host Attachment (3174)

 

 

 

Values specified on the CRTCTLRWS command and for

 

 

 

question 101 must match as follows:

 

 

 

v LINKTYPE(*SDLC), 101 = 2

 

 

 

v LINKTYPE(*X25), 101 = 3

 

 

 

v LINKTYPE(*LAN), 101 = 7 (token ring)

 

 

 

v LINKTYPE(*LAN), 101 = 8 (Ethernet)

Modem data

MODEMRATE

318

Fullor Half-Speed Transmission

rate select

 

 

The values specified for the MODEMRATE parameter on the

 

 

 

 

 

 

CRTLINSDLC and CRTLINX25 commands must match

 

 

 

question 318 as follows:

 

 

 

v If MODEMRATE(*FULL), 318 = 0

 

 

 

v If MODEMRATE(*HALF), 318 = 1

Chapter 7. Communicating with remote workstation controllers 59

 

 

3174

 

AS/400

AS/400

Configuration

 

Prompt

Parameter

Questions

Notes

 

 

 

 

Local network

NETADR

423

Host DTE Address (HNAD)

address

 

 

For X.25 SVCs, the network address specified on the

 

 

 

 

 

 

CRTLINX25 command and in question 423 must match.

 

 

 

 

NRZI data

NRZI

313

NRZ or NRZI Encoding

encoding

 

 

For SDLC lines only, the values specified on the

 

 

 

 

 

 

CRTLINSDLC command and in question 313 must match as

 

 

 

follows:

 

 

 

v If NRZI(*NO), 313 = 0

 

 

 

v If NRZI(*YES), 313 = 1

Source service

SSAP

940

Ring Address Assignment

access point

 

 

The value specified for the SSAP parameter on the

 

 

 

 

 

 

CRTCTLRWS command must match the SAP@ associated

 

 

 

with the Ring@ (adapter address) of the AS/400 system on

 

 

 

the Ring Address Assignment display. Used for token-ring

 

 

 

only.

 

 

 

 

Short-hold

SHM

367

X.21 Switched Short-Hold Mode

mode

 

 

Values specified on the CRTCTLRWS command and in

 

 

 

 

 

 

question 367 match as follows:

 

 

 

v If SHM(*NO), 367 = 0

 

 

 

v If SHM(*YES), 367 = 2

Station address

STNADR

104

Control Unit Address

 

 

 

Value specified for question 104 must match the STNADR

 

 

 

specified on the CRTCTLRWS command.

 

 

 

 

Switched

SWITCHED

317

Telecommunication Facilities

connection

 

 

Values specified on the CRTLINSDLC command and in

 

 

 

 

 

 

question 317 match as follows:

 

 

 

v If SWITCHED(*NO), 317 = 0

 

 

 

v If SWITCHED(*YES), 317 = 1

Note: If you are using a 3174 Model 1L Gateway to connect an AS/400 system to a host system on a Token-Ring, the value specified for item 900 (Token-Ring Network Address of the Gateway) must match the value specified for the ADPTADR parameter on the CRTCTLHOST command.

Matching AS/400 parameters for a 3274 controller

You match the AS/400 configuration parameters with the configuration questions and sequence numbers to configure the 3274 controller. These parameters are described in the following table.

For more information about configuring the 3274 controller, see the 3274 Control Unit Planning, Setup, and Customizing Guide.

To configure the AS/400 to a 3274 controller:

vSee “Example: Connecting an AS/400 to a 3174 control unit” on page 61 for an example of connecting an AS/400 to a 3174 retail controller.

vUse the following table to connect an AS/400 to a 3274 controller.

60 Version 5

 

 

3274

 

AS/400

AS/400

Sequence

 

Prompt

Parameter

Number

Notes

 

 

 

 

Connection

CNNNBR

411

3274 DTE Address

number

 

 

For X.25 SVCs, the connection number specified on the

 

 

 

 

 

 

CRTCTLRWS command and in sequence number 411 must

 

 

 

match.

 

 

 

 

Exchange

EXCHID

215

Physical Unit Identification

identifier

 

 

For switched connections, the 5-digit hexadecimal value specified

 

 

 

 

 

 

for sequence number 215 must match the last 5 digits of the

 

 

 

exchange identifier specified on the CRTCTLRWS command.

 

 

 

 

X.25 link

LINKPCL

403

Logical Link Control

protocol

 

 

For X.25 connections, values specified must match. Specify

 

 

 

 

 

 

LINKPCL(*QLLC) on the CRTCTLRWS command; specify 1

 

 

 

(QLLC) for sequence number 403.

 

 

 

 

Link type

LINKTYPE

331

BSC/SDLC/X.25 Protocol

 

 

 

Values specified on the CRTCTLRWS command and in

 

 

 

sequence number 331 must match as follows:

 

 

 

v If LINKTYPE(*SDLC), 331 = 1

 

 

 

v If LINKTYPE(*X25), 331 = 2

Local network

NETADR

410

Host DTE Address (HNAD)

address

 

 

For X.25 SVCs, the network address specified on the

 

 

 

 

 

 

CRTLINX25 command and in sequence number 410 must match.

 

 

 

 

Modem data

MODEMRATE

318

Fullor Half-Speed Transmission

rate select

 

 

The values specified for the MODEMRATE parameter on the

 

 

 

 

 

 

CRTLINSDLC and CRTLINX25 commands must match sequence

 

 

 

number 318 as follows:

 

 

 

v If MODEMRATE(*FULL), 318 = 0

 

 

 

v If MODEMRATE(*HALF), 318 = 1

NRZI data

NRZI

313

NRZ or NRZI Encoding

encoding

 

 

For SDLC lines only, the values specified must match as follows:

 

 

 

 

 

 

v If NRZI(*NO), 313 = 0

 

 

 

v If NRZI(*YES), 313 = 1

Short-hold

SHM

362

X.21 Switched Options

mode

 

 

If SHM(*YES) is specified on the CRTCTLRWS command, digit 7

 

 

 

 

 

 

or 8 of question 362 must be set to 1. (For example, xxxxxx10

 

 

 

indicates that the DCE is supported for direct calls.)

 

 

 

 

Station address

STNADR

302

Control Unit Address

 

 

 

Value specified for item 302 must match that specified on the

 

 

 

CRTCTLRWS command.

 

 

 

 

Example: Connecting an AS/400 to a 3174 control unit

Configuration parameters must be coordinated when you connect an AS/400 system to a 3174 controller.

Chapter 7. Communicating with remote workstation controllers 61

The following diagram shows the AS/400 parameters and 3174 parameters that need to match when you use token-ring.

Matching AS/400 parameters for finance controllers

You must coordinate several parameter values that are specified for the AS/400 system and in the controller configuration for finance communications.

For an example of connecting an AS/400 to a 4701 finance controller, see “Example: Connecting AS/400 to a finance network” on page 67.

v“Matching AS/400 parameters for 470x finance controllers”

v“Matching AS/400 parameters for FBSS finance controllers” on page 64

Matching AS/400 parameters for 470x finance controllers

You must match the AS/400 configuration parameters with the configuration (CPGEN) for the 4701 and 4702 finance controllers. These parameters are described in the following table.

AS/400 prompts are listed in alphabetical order by parameter name; the AS/400 commands on which the parameters are specified are included in the rightmost column of the table.

For more information about configuring the 4700 controllers, see Volume 6 of the 4700 Finance Communication System Controller Programming Library, GC31-2068.

To configure the AS/400 to a 470x finance controller:

vSee “Example: Connecting AS/400 to a finance network” on page 67 for an example of connecting an AS/400 to a 4701 finance controller.

vUse the following table to connect an AS/400 to a 4701 finance controller.

62 Version 5

 

AS/400

 

 

AS/400 Prompt

Parameter

4700 Macro

4700 Parameter

 

 

 

 

Connection

CNN

COMLINK

ACB

type

 

 

For SDLC finance communications, if the line is switched

 

 

 

 

 

 

(CNN(*SWTPP) on the CRTLINSDLC command or

 

 

 

SWITCHED(*YES) on the CRTCTLFNC command), include the

 

 

 

SWM value on the ACB parameter (ACB = SWM).

 

 

 

 

Exchange

EXCHID

X25CKT

XID

identifier

 

 

The values specified for the 4700 and the AS/400 system must

 

 

 

 

 

 

match. The block number for the 4700 (first 3 digits of the

 

 

 

AS/400 EXCHID parameter) must be 057.

 

 

 

The 4700 parameter values are decimal numbers; the AS/400

 

 

 

values are hexadecimal.

 

 

 

 

X.25 link

LINKPCL

X25CKT

LLC

protocol

 

 

For X.25 finance communications, the LLC parameter must

 

 

 

 

 

 

specify QLLC for the type of logical link control.

 

 

 

LINKPCL(*QLLC) must also be specified on the AS/400

 

 

 

CRTCTLFNC command.

 

 

 

 

Link type

LINKTYPE

COMLINK

TYPE

 

 

 

4700 TYPE parameter must match the LINKTYPE parameter

 

 

 

specified on the AS/400 CRTCTLFNC command.

 

 

 

v If LINKTYPE(*SDLC), specify TYPE = 4502.

 

 

 

v If LINKTYPE(*X25), specify TYPE = 1424.

Local location

LOCADR

STATION

ID

address

 

 

If the optional LUA parameter is not specified, the value

 

 

 

 

 

 

specified for the 4700 ID parameter must match the value

 

 

 

specified for the LOCADR parameter on the AS/400 create

 

 

 

device description command. If LUA is specified, the LUA

 

 

 

parameter value must match the LOCADR parameter.

 

 

 

The 4700 parameter values are decimal numbers; the AS/400

 

 

 

values are hexadecimal.

 

 

 

 

Chapter 7. Communicating with remote workstation controllers 63

 

AS/400

 

 

AS/400 Prompt

Parameter

4700 Macro

4700 Parameter

 

 

 

 

Maximum

MAXFRAME

COMLINK

CNL

frame size

 

 

Value specified for the 4700 CNL parameter must be

 

 

 

 

 

 

coordinated with the value specified for the AS/400 MAXFRAME

 

 

 

parameter on the CRTCTLFNC command. Because the

 

 

 

MAXFRAME parameter includes transmission and request

 

 

 

header lengths, MAXFRAME should be 9 bytes longer than the

 

 

 

4700 MWL parameter.

 

 

 

 

 

 

 

MWL

 

 

 

Value specified for the 4700 MWL parameter must be

 

 

 

coordinated with the value specified for the AS/400 MAXFRAME

 

 

 

parameter on the CRTCTLFNC command. Because the

 

 

 

MAXFRAME parameter includes transmission and request

 

 

 

header lengths, MAXFRAME should be 9 bytes longer than the

 

 

 

4700 MWL parameter.

 

 

 

If the AS/400 maximum length of request unit (MAXLENRU

 

 

 

parameter) specified for device descriptions attached to the 4700

 

 

 

controller is larger than the MAXFRAME parameter specified for

 

 

 

the controller description, the 4700 should also specify

 

 

 

OPTIONS=(SEGMENT).

 

 

 

 

NRZI data

NRZI

COMLINK

ACB

encoding

 

 

For SDLC finance communications, if the line does not use NRZI

 

 

 

 

 

 

data encoding (NRZI(*NO) on the CRTLINSDLC command),

 

 

 

include the DCE value on the ACB parameter (ACB = DCE).

 

 

 

 

Station address

STNADR

X25CKT

CUA

 

 

 

The values specified for the AS/400 STNADR parameter on the

 

 

 

CRTCTLFNC command must match the physical address (CUA)

 

 

 

parameter specified for the 4700.

 

 

 

 

Matching AS/400 parameters for FBSS finance controllers

You must coordinate several parameter values that are specified for the AS/400 system and IBM Financial Branch System Services (FBSS) finance controllers in the controller configuration. The following table shows those AS/400 configuration parameters that must match values on the SDLC, Token-Ring, or X.25DLC configuration displays for FBSS controllers.

AS/400 prompts are listed in alphabetical order by parameter name; the AS/400 commands on which the parameters are specified are included in the rightmost column of the table.

For more information about configuring FBSS controllers, see the IBM Financial Branch System Services Installation Planning and Administration Guide, SC19-5173.

For more information about configuring the 4700 controllers, see Volume 6 of the 4700 Finance Communication System Controller Programming Library, GC31-2068.

To configure the AS/400 to a FBSS finance controller:

vSee “Example: Connecting AS/400 to a finance network” on page 67 for an example of connecting an AS/400 to a 4701 finance controller.

vUse the following table to connect an AS/400 to a 4701 finance controller.

64 Version 5

 

 

FBSS

 

 

 

AS/400

Configuration

 

 

AS/400 Prompt

Parameter

Display

FBSS Prompt

 

 

 

 

 

 

LAN adapter address

ADPTADR

Token Ring

PC address

 

 

 

Communications

If the AS/400 system uses a Token-Ring network line

 

 

 

 

 

 

to connect to the FBSS controller, values specified for

 

 

 

the FBSS and on the ADPTADR parameter on the

 

 

 

CRTLINTRN command must match.

 

 

 

 

If the AS/400 system uses an Ethernet line through

 

 

 

an 8209 LAN Bridge, see ″Appendix C: Local Area

 

 

 

Network Addressing Considerations″ in the

 

 

 

Communications Configuration

book.

 

 

 

 

 

 

 

 

Host/37xx/4700 address

 

 

 

 

If the AS/400 system uses a Token-Ring network line

 

 

 

to connect to the FBSS controller, values specified for

 

 

 

the FBSS and on the ADPTADR parameter on the

 

 

 

CRTLINTRN command must match.

 

 

 

 

If the AS/400 system uses an Ethernet line through

 

 

 

an 8209 LAN Bridge, see ″Appendix C: Local Area

 

 

 

Network Addressing Considerations″ in the

 

 

 

Communications Configuration

book.

 

 

 

 

 

Connection type

CNN

SDLC

Switched line

 

 

 

Communications

Values specified for the FBSS and AS/400

 

 

 

 

 

 

configurations must match:

 

 

 

 

v If the FBSS response is Yes, CNN(*SWTPP) must

 

 

 

be specified for the CRTLINSDLC command and

 

 

 

SWITCHED(*YES) for the CRTCTLFNC command.

 

 

 

v If the FBSS response is No, CNN(*NONSWTPP) or

 

 

 

CNN(*MP) must be specified for the CRTLINSDLC

 

 

 

command and SWITCHED(*NO) for the

 

 

 

CRTCTLFNC command.

 

 

 

 

 

 

Destination service

DSAP

Token Ring

Service access point for PC

 

access point

 

Communications

Values specified for the FBSS and for the DSAP

 

 

 

 

 

 

parameter on the CRTCTLFNC command must

 

 

 

match.

 

 

 

 

 

 

Duplex

DUPLEX

SDLC

Line mode

 

 

 

Communications

Values specified for the FBSS and AS/400

 

 

 

 

 

 

configurations must match:

 

 

 

 

v If the FBSS response is Turn. required,

 

 

 

DUPLEX(*HALF) must be specified for the

 

 

 

CRTLINSDLC command.

 

 

 

 

v If the FBSS response is CRTS (Continuous request

 

 

 

to send), DUPLEX(*FULL) must be specified for

 

 

 

the CRTLINSDLC command.

 

 

 

 

 

 

Chapter 7. Communicating with remote workstation controllers 65

 

 

FBSS

 

 

AS/400

Configuration

 

AS/400 Prompt

Parameter

Display

FBSS Prompt

 

 

 

 

Exchange identifier

EXCHID

SDLC

Identification block and Identification number

 

 

Communications

The values specified for the FBSS controller must

 

 

 

 

 

 

match the value specified in the EXCHID parameter

 

 

 

of the CRTCTLFNC command. The EXCHID

 

 

 

parameter must be specified as: xxxyyyyy, where xxx

 

 

 

matches the FBSS Identification block and yyyyy

 

 

 

matches the FBSS Identification number.

 

 

 

 

Link type

LINKTYPE

Communication

Data Link Control

 

 

Servers

Values specified for the FBSS and AS/400

 

 

 

 

 

 

configurations must match:

 

 

 

v If the FBSS response is SDLC, LINKTYPE(*SDLC)

 

 

 

must be specified for the CRTCTLFNC command.

 

 

 

v If the FBSS response is TRDLC, LINKTYPE(*LAN)

 

 

 

must be specified for the CRTCTLFNC command.

 

 

 

v If the FBSS response is X25DLC, LINKTYPE(*X25)

 

 

 

must be specified for the CRTCTLFNC command.

 

 

 

 

Local location address

LOCADR

Session-Id and LU

Host Logical Unit Numbers

 

 

Assignments

FBSS logical unit number must match the LOCADR

 

 

 

 

 

 

parameter value specified on the CRTDEVFNC

 

 

 

command.

 

 

 

The FBSS logical unit assignments are decimal

 

 

 

numbers; the AS/400 values must be hexadecimal.

 

 

 

 

 

 

LU Assignments

Host Logical Unit Numbers

 

 

for Display

FBSS logical unit number must match the LOCADR

 

 

Emulators

 

 

 

parameter value specified on the CRTDEVDSP or

 

 

LU Assignments

CRTDEVPRT command for 3270 devices attached to

 

 

for 3287 Printer

the FBSS controller.

 

 

Emulator

The FBSS logical unit assignments are decimal

 

 

 

 

 

 

numbers; the AS/400 values must be hexadecimal.

 

 

 

 

NRZI data encoding

NRZI

SDLC

N.R.Z.I.

 

 

Communications

Values specified for the AS/400 CRTLINSDLC

 

 

 

 

 

 

command and the FBSS controller must match.

 

 

 

 

Source service access

SSAP

Token Ring

Service access point for Host/37xx/4700

point

 

Communications

Values specified for the FBSS and for the SSAP

 

 

 

 

 

 

parameter on the CRTCTLFNC command must

 

 

 

match.

 

 

 

 

SSCP identifier

SSCPID

SSCP Names

SSCP namexx

 

 

 

If used, the value specified for the FBSS controller

 

 

 

must match the last 10 digits of the SSCPID

 

 

 

parameter on the CRTCTLFNC command.

 

 

 

 

Station address

STNADR

SDLC

Station address

 

 

Communications

Values specified for the AS/400 CRTCTLFNC

 

 

 

 

 

 

command and the FBSS controller must match.

 

 

 

 

66 Version 5

Example: Connecting AS/400 to a finance network

Configuration parameters must be coordinated when you connect an AS/400 system to a 4701 finance controller.

Finance communications use high-level language operations and communications functions that allow you to communicate between an AS/400 system and finance controllers.

Matching AS/400 parameters for retail controllers

You must coordinate several AS/400 parameter values with retail controllers for retail communications. These values are specified for the AS/400 system and in the controller configuration.

For an example on connecting an AS/400 to a 4690 retail controller, see “Examples: Connecting AS/400 to a 4690 retail controller” on page 75.

To match parameters for VTAM definition statements, see the following.

v“Matching AS/400 controller description parameters for a host system” on page 23

v“Matching AS/400 device description parameters for a host system” on page 24

v“Matching AS/400 line description parameters for a host system” on page 21

For more information about configuring the 3651 controller, see the IBM Programmable Store System Language and Host Services: Macro Reference, GC30-3076, book.

Chapter 7. Communicating with remote workstation controllers 67

To configure an AS/400 to a retail controller, see the following.

v“Matching AS/400 parameters for 3651 retail controllers”

v“Matching AS/400 parameters for 3684 retail controllers” on page 70

v“Matching AS/400 parameters for 4680/4690 LINE parameter” on page 72

v“Matching AS/400 parameters for 4680/4690 LINK parameter” on page 73

v“Matching AS/400 parameters for 4684 retail controllers” on page 74

Matching AS/400 parameters for 3651 retail controllers

You must coordinate several parameter values for retail communications. These values are specified for the AS/400 system and the 3651 retail controller. The following table lists those AS/400 parameters that must match values for the 3651 retail controllers.

Before you match parameters for 3651 retail controllers, you need to match AS/400 controller, device, and line descriptions parameters with the host system.

AS/400 parameters are listed in alphabetical order; the commands on which the parameters are specified are included in the rightmost column of the table.

For more information about configuring the 3651 controller, see the IBM Programmable Store System Language and Host Services: Macro Reference

To configure the AS/400 to a 3651 retail controller, use the following table.

 

AS/400

3651 Definition

 

AS/400 Prompt

Parameter

Statement

3651 Parameter

 

 

 

 

Connection type

CNN

QFHOST

SDLCLIN

 

 

 

Value specified for the AS/400 CNN parameter on the

 

 

 

CRTLINSDLC command must match the values

 

 

 

specified for bits 2 and 3 of the 3651 SDLCLIN

 

 

 

parameter.

 

 

 

 

Duplex

DUPLEX

QFHOST

SDLCLIN

 

 

 

Value specified for the AS/400 DUPLEX parameter on

 

 

 

the CRTLINSDLC command must match the value

 

 

 

specified for bit 6 of the 3651 SDLCLIN parameter.

 

 

 

 

Exchange identifier

EXCHID

QFHOST

SENDID

 

 

 

3651 SENDID parameter must match the last 5 digits of

 

 

 

the EXCHID parameter specified on the AS/400

 

 

 

CRTLINSDLC command. (This parameter is used only

 

 

 

for switched line communications.)

 

 

 

 

 

 

 

RECVID

 

 

 

3651 RECVID parameter must match the last 5 digits of

 

 

 

the EXCHID parameter specified on the AS/400

 

 

 

CRTCTLRTL command.

 

 

 

 

Modem data rate

MODEMRATE

QFHOST

SDLCLIN

 

 

 

Value specified for the AS/400 MODEMRATE parameter

 

 

 

on the CRTLINSDLC command must match the value

 

 

 

specified for bit 5 of the 3651 SDLCLIN parameter.

 

 

 

 

NRZI data encoding

NRZI

QFHOST

SDLCLIN

 

 

 

Value specified for the AS/400 NRZI parameter on the

 

 

 

CRTLINSDLC command must match the value specified

 

 

 

for bit 1 of the 3651 SDLCLIN parameter.

 

 

 

 

68 Version 5

 

AS/400

3651 Definition

 

AS/400 Prompt

Parameter

Statement

3651 Parameter

 

 

 

 

SSCP identifier

SSCPID

QFHOST

SSCPID

 

 

 

3651 SSCPID parameter must match the SSCPID

 

 

 

parameter specified on the AS/400 CRTCTLRTL

 

 

 

command.

 

 

 

 

Station address

STNADR

QFHOST

SDLCPOL

 

 

 

3651 SDLCPOL parameter must match the STNADR

 

 

 

parameter specified on the AS/400 CRTCTLRTL

 

 

 

command.

 

 

 

 

Switched connection

SWITCHED

QFHOST

SDLCLIN

 

 

 

Value specified for the AS/400 SWITCHED parameter

 

 

 

on the CRTCTLRTL command must match the values

 

 

 

specified for bits 2 and 3 of the 3651 SDLCLIN

 

 

 

parameter.

 

 

 

 

Note: For the AS/400 system, the 3651 QFHOST definition must specify DIRATT=NO.

The value specified for the AS/400 parameters on the CRTLINSDLC command must match the values specified on the 3651 SDLCLIN parameter.

For information about the SDLCLIN parameter, see “Specifying the SDLCLIN parameter for 3651 retail controllers”.

Specifying the SDLCLIN parameter for 3651 retail controllers

The following table describes how to coordinate values for parameters on the AS/400 CRTLINSDLC and CRTCTLRTL commands with bits that are specified for the 3651 SDLCLIN parameter.

The SDLCLIN parameter is specified as a series of 8 bits, designated 0 through 7 (01234567). The default value for the SDLCLIN parameter when used with an SDLC line is 01100001, or hex 61.

The default value for each bit is underlined in the Bit Value column.

To configure the AS/400 to a 3651 controller, use the following table.

 

 

AS/400 Parameter

 

SDLCLIN Bit

Bit Value

and Value

Notes

 

 

 

 

0

0

None

Data terminal ready. There is no equivalent

 

 

 

parameter for the AS/400 system. Specify 0 to

 

 

 

indicate that the data terminal ready (DTR) signal is

 

 

 

on when the controller is powered on, or 1 to

 

 

 

indicate that the DTR is off when the controller is

 

 

 

powered on.

 

1

None

 

 

 

 

 

This bit should be set to 1 only if the configuration

 

 

 

being defined includes IBM world trade data

 

 

 

communications equipment (DCE) in a switched

 

 

 

network.

 

 

 

 

1

0

NRZI(*NO)

Specify 1 if the data communications equipment

 

 

 

(DCE) provides the clocking or if NRZI data

 

1

NRZI(*YES)

 

encoding is used.

 

 

 

 

 

 

 

Chapter 7. Communicating with remote workstation controllers 69

 

 

AS/400 Parameter

 

SDLCLIN Bit

Bit Value

and Value

Notes

 

 

 

 

2 and 3

00

SWITCHED(*YES)

Bit 2: Specify 1 if using nonswitched

 

 

CNN(*SWTPP)

communications, or 0 if using switched

 

 

 

communications. If switched, the SENDID parameter

 

01

Not valid

 

must also be specified.

 

 

 

 

10

SWITCHED(*NO) and

 

Bit 3: Specify 1 if using a multipoint communications

 

 

CNN(*NONSWTPP)

 

 

 

protocol, or 0 if not. 01 is not a valid combination for

 

11

SWITCHED(*NO) and

 

these bits.

 

 

CNN(*MP)

 

 

 

 

 

 

 

4

0

None (See Notes)

Direct attachment. This bit must be set to 0 for

 

 

 

communications with the AS/400 system. There is no

 

1

None

 

equivalent parameter for the AS/400 system.

 

 

 

 

 

 

 

5

0

MODEMRATE(*FULL)

Modem data rate.

 

 

 

 

 

1

MODEMRATE(*HALF)

 

 

 

 

 

6

0

DUPLEX(*HALF)

Data carrier setting.

 

 

 

 

 

1

DUPLEX(*FULL)

 

 

 

 

 

7

0

None

Answer tone generation. There is no equivalent

 

 

 

parameter for the AS/400 system. Specify 0 to

 

 

 

indicate that the modem generates the answer tone,

 

1

None

 

or 1 to indicate that the controller generates the

 

 

 

 

 

 

answer tone.

 

 

 

 

For information about SDLC, see “Synchronous data link control network” on page 94.

Matching AS/400 parameters for 3684 retail controllers

You must coordinate parameters with the AS/400 system and the 3684 retail controller. The following table lists those parameters.

AS/400 parameters are listed in alphabetical order; the commands on which the parameters are specified are included in the rightmost column of the table.

To configure the AS/400 to a 3684 controller, use the following table.

 

 

3684

 

AS/400

AS/400

Definition

 

Prompt

Parameter

Statement

3684 Parameter

 

 

 

 

Connection

CNN

QFSFGLNK

LINECON

type

 

 

Value specified for the AS/400 CNN parameter on the

 

 

 

 

 

 

CRTLINSDLC command must match the values specified for bits

 

 

 

2 and 3 of the 3684 LINECON parameter.

 

 

 

 

Duplex

DUPLEX

QFSFGLNK

LINECON

 

 

 

Value specified for the AS/400 DUPLEX parameter on the

 

 

 

CRTLINSDLC command must match the value specified for bit 6

 

 

 

of the 3684 LINECON parameter.

 

 

 

 

70 Version 5

 

 

3684

 

AS/400

AS/400

Definition

 

Prompt

Parameter

Statement

3684 Parameter

 

 

 

 

Exchange

EXCHID

QVSFGLNK

SENDID

identifier

 

 

3684 SENDID parameter must match the last 5 digits of the

 

 

 

 

 

 

EXCHID parameter specified on the AS/400 CRTCTLRTL

 

 

 

command.

 

 

 

 

 

 

 

RECVID

 

 

 

3684 RECVID parameter must match the last 5 digits of the

 

 

 

EXCHID parameter specified on the AS/400 CRTLINSDLC

 

 

 

command. (This parameter is used only for switched line

 

 

 

communications.)

 

 

 

 

Modem data

MODEMRATE

QFSFGLNK

LINECON

rate

 

 

Value specified for the AS/400 MODEMRATE parameter on the

 

 

 

 

 

 

CRTLINSDLC command must match the value specified for bit 5

 

 

 

of the 3684 LINECON parameter.

 

 

 

 

NRZI data

NRZI

QFSFGLNK

LINECON

encoding

 

 

Value specified for the AS/400 NRZI parameter on the

 

 

 

 

 

 

CRTLINSDLC command must match the value specified for bit 1

 

 

 

of the 3684 LINECON parameter.

 

 

 

 

Switched

SNBU

QFSFGLNK

LINECON

network backup

 

 

Value specified for the AS/400 SNBU parameter on the

 

 

 

 

 

 

CRTLINSDLC command must match the value specified for bit 4

 

 

 

of the 3684 LINECON parameter.

 

 

 

 

SSCP identifier

SSCPID

QVSFGLNK

SSCPID

 

 

 

3684 SSCPID parameter must match the SSCPID parameter

 

 

 

specified on the AS/400 CRTCTLRTL command.

 

 

 

 

Station address

STNADR

QVSFGLNK

POLCHAR

 

 

 

3684 POLCHAR parameter must match the 2-digit hexadecimal

 

 

 

address specified for the STNADR parameter on the AS/400

 

 

 

CRTCTLRTL command. Allowed values are in the range 01

 

 

 

through FE.

 

 

 

 

Switched

SWITCHED

QFSFGLNK

LINECON

connection

 

 

Value specified for the AS/400 SWITCHED parameter on the

 

 

 

 

 

 

CRTCTLRTL command must match the values specified for bits

 

 

 

2 and 3 of the 3684 LINECON parameter.

 

 

 

 

Note: For the AS/400 system, the 3684 QVSFGLNK, QVSFCOMM, and QVSFSESN definitions must each specify DATALNK=SDLC.

Values specified for the AS/400 parameters on the CRTCTLRTL and CRTLINSDLC commands must match the values specified on the 3684 LINECON parameter.

Specifying the LINECON parameter for 3684 retail controllers

The following table describes how to coordinate values that are specified for parameters on the AS/400 CRTLINSDLC and CRTCTLRTL commands. You must coordinate the values with bits that are specified for the 3684 LINECON parameter.

The LINECON parameter is specified as a series of 8 bits, designated 0 through 7 (01234567). The default value for the LINECON parameter when used with an SDLC line is 01000001, or hex 41.

Chapter 7. Communicating with remote workstation controllers 71

The default value for each bit is underlined in the Bit Value column.

To configure the AS/400 to a 3684 retail controller, use the following table.

 

 

AS/400 Parameter and

 

LINECON Bit

Bit Value

Value

Notes

 

 

 

 

0

0

None

Enabled at initial microprogram load (IML). There is no

 

 

 

equivalent parameter for the AS/400 system. Specify 0

 

1

None

to indicate that the controller is enabled at IML, or 1 to

 

 

 

indicate that the controller is not enabled at IML.

 

 

 

 

1

0

NRZI(*NO)

Specifies NRZI data encoding with leading pads (1) or

 

 

 

non-NRZI without leading pads (0).

 

1

NRZI(*YES)

 

 

 

 

 

 

2 and 3

00

SWITCHED (*YES) and

Bit 2: Specify 1 is using nonswitched communications,

 

 

CNN(*SWTPP)

or 0 if using switched communications. If switched, the

 

 

 

SENDID parameter must also be specified.

 

01

Not valid

 

 

 

 

 

Bit 3: Specify 1 if using a multipoint communications

 

10

SWITCHED(*NO) and

 

 

CNN(*NONSWTPP)

protocol, or 0 if not. 01 is not a valid combination for

 

 

 

these bits.

 

11

SWITCHED(*NO) and

 

 

 

 

CNN(*MP)

 

 

 

 

 

4

0

SNBU(*NO)

Switched network backup.

 

 

 

 

 

1

SNBU(*YES)

 

 

 

 

 

5

0

MODEMRATE(*FULL)

Data rate select speed.

 

 

 

 

 

1

MODEMRATE(*HALF)

 

 

 

 

 

6

0

DUPLEX(*HALF)

Data carrier setting.

 

 

 

 

 

1

DUPLEX(*FULL)

 

 

 

 

 

7

0

None

Answer tone generation. There is no equivalent

 

 

 

parameter for the AS/400 system. Specify 0 to indicate

 

1

None

that the controller generates the answer tone, or 1 to

 

 

 

indicate that the answer tone is omitted.

 

 

 

 

Matching AS/400 parameters for 4680/4690 LINE parameter

You must coordinate parameters between the AS/400 and the 4680 or 4690 retail controller. The following table lists those parameters. The 4680 controller requires configuration of the SDLC/SNA LINE parameter.

AS/400 parameters are listed in alphabetical order; the commands on which the parameters are specified are included in the rightmost column of the table.

For more information about configuring the 4680, see the IBM 4680 Store System: Programming Guide.

To configure the AS/400 to a 4680/4690 controller:

vSee “Examples: Connecting AS/400 to a 4690 retail controller” on page 75 for an example of an AS/400 connecting to a 4690 retail controller.

vUse the following table to connect an AS/400 to a 4690 retail controller.

72 Version 5

AS/400 Prompt

AS/400 Parameter

4680 Line Parameter

 

 

 

Connection type

CNN

4680 CONNECTION TYPE parameter value must be coordinated with

 

 

the values specified for the AS/400 CNN and SWTCNN parameters on

 

 

the CRTLINSDLC command and with the SWITCHED and INLCNN

 

 

parameters on the CRTCTLRTL command.

 

 

v If CNN(*NONSWTPP) and SWITCHED(*NO) are specified for the

 

 

AS/400 system, specify CONNECTION TYPE = 1 for the 4680.

 

 

v If CNN(*MP) and SWITCHED(*NO) are specified for the AS/400

 

 

system, specify CONNECTION TYPE = 2 for the 4680.

 

 

v If CNN(*SWTPP), SWITCHED(*YES), INLCNN(*DIAL), and either

 

 

SWTCNN(*DIAL) or SWTCNN(*BOTH) are specified for the AS/400

 

 

system, specify CONNECTION TYPE = 3 for the 4680.

 

 

v If CNN(*SWTPP), SWITCHED(*YES), INLCNN(*DIAL), and either

 

 

SWTCNN(*DIAL) or SWTCNN(*BOTH) are specified for the AS/400

 

 

system, specify CONNECTION TYPE = 4 for the 4680. This

 

 

configuration allows the 4680 to manually answer calls from the

 

 

AS/400 system or to manually call the AS/400 system.

 

 

v If CNN(*SWTPP), SWITCHED(*YES), INLCNN(*ANS), and either

 

 

SWTCNN(*ANS) or SWTCNN(*BOTH) are specified for the AS/400

 

 

system, specify CONNECTION TYPE = 4 for the 4680. This

 

 

configuration requires the 4680 to manually call the AS/400 system.

 

 

 

Initial connection

INLCNN

See description for the CNN (Connection type) parameter.

 

 

 

Modem data rate

MODEMRATE

4680 DATA RATE parameter must match the MODEMRATE parameter

select

 

specified on the AS/400 CRTLINSDLC command.

 

 

 

NRZI data encoding

NRZI

4680 NRZI MODE parameter must match the NRZI parameter specified

 

 

on the AS/400 CRTLINSDLC command.

 

 

 

Station address

STNADR

4680 STATION ADDRESS parameter must match the STNADR

 

 

parameter specified on the AS/400 CRTCTLRTL command.

 

 

 

Switched

SWITCHED

See description for the CNN (Connection type) parameter.

connection

 

 

 

 

 

Switched

SWTCNN

See description for the CNN (Connection type) parameter.

connection

 

 

 

 

 

Matching AS/400 parameters for 4680/4690 LINK parameter

You must coordinate parameters between the AS/400 and the 4680 store controller. The following tables lists the parameter values. The 4680 controller requires configuration of the SDLC/SNA LINK parameter.

AS/400 parameters are listed in alphabetical order; the commands on which the parameters are specified are included in the rightmost column of the table.

For more information about configuring the 4680 controller, see the IBM 4680 Store System: Programming Guide.

To configure the AS/400 to a 4680/4690 controller:

vSee “Examples: Connecting AS/400 to a 4690 retail controller” on page 75 for an example of an AS/400 connecting to a 4690 retail controller.

vUse the following table to connect an AS/400 to a 4680/4690 retail controller.

AS/400 Prompt

AS/400 Parameter

4680 Link Parameter

 

 

 

Exchange identifier

EXCHID

For switched lines only, the 4680 EXCHANGE ID parameter must match

 

 

the EXCHID parameter specified on the AS/400 CRTCTLRTL command.

 

 

 

Chapter 7. Communicating with remote workstation controllers 73

AS/400 Prompt

AS/400 Parameter

4680 Link Parameter

 

 

 

Local location

LOCADR

4680 SESSION ADDRESS parameter must match the LOCADR

address

 

parameter specified on the AS/400 CRTDEVRTL command. Session

 

 

address 01 is reserved for host command processor sessions.

 

 

 

SSCP identifier

SSCPID

4680 SSCP ID parameter must match the SSCPID parameter specified on

 

 

the AS/400 CRTCTLRTL command.

 

 

 

Matching AS/400 parameters for 4684 retail controllers

You must coordinate parameter values with the AS/400 and the 4684 retail controller when running IBM Retail Industry Programming Support Services (RIPSS). The following table lists those parameters.

AS/400 parameters are listed in alphabetical order; the commands on which the parameters are specified are included in the rightmost column of the table.

For more information about configuring for RIPSS on the 4684, see the IBM Retail Industry Programming Support Services: Planning and Installation Guide, SC33-0650.

To configure the AS/400 to a 4684 controller:

vSee “Examples: Connecting AS/400 to a 4690 retail controller” on page 75 for an example of an AS/400 connecting to a 4690 retail controller.

vUse the following table to connect to a 4690 retail controller.

 

AS/400

RIPSS Configuration

 

AS/400 Prompt

Parameter

Display

RIPSS Prompt

 

 

 

 

LAN remote

ADPTADR

TRDLC Server Data

Local node (Hex)

adapter address

 

 

For Token-Ring connections, the values specified

 

 

 

 

 

 

for the RIPSS configuration and for the AS/400

 

 

 

CRTCTLRTL command must match.

 

 

 

 

Local adapter

ADPTADR

TRDLC Server Data

Remote node (Hex)

address

 

 

For Token-Ring connections, the values specified

 

 

 

 

 

 

for the RIPSS configuration and for the AS/400

 

 

 

CRTLINTRN command must match.

 

 

 

 

Destination service

DSAP

TRDLC Server Data

Local SAP (Hex)

access point

 

 

For Token-Ring connections, the values specified

 

 

 

 

 

 

for the RIPSS configuration and for the AS/400

 

 

 

CRTCTLRTL command must match.

 

 

 

 

Duplex

DUPLEX

SDLC Server Data

4-wire constant RTS?

 

 

 

For SDLC connections, the values specified for

 

 

 

RIPSS and AS/400 configurations must match:

 

 

 

v If the RIPSS response is N, DUPLEX(*HALF)

 

 

 

must be specified for the CRTLINSDLC

 

 

 

command.

 

 

 

v If the RIPSS response is Y, DUPLEX(YES) must

 

 

 

be specified for the CRTLINSDLC command.

 

 

 

 

74 Version 5

 

AS/400

RIPSS Configuration

 

AS/400 Prompt

Parameter

Display

RIPSS Prompt

 

 

 

 

Exchange identifier

EXCHID

SDLC Server Data

Block number (hex) and XID (hex)

 

 

 

For SDLC connections, the values specified for the

 

 

 

RIPSS configuration must match the value

 

 

 

specified in the EXCHID parameter of the

 

 

 

CRTCTLRTL command. The EXCHID parameter

 

 

 

must be specified as: xxxyyyyy, where xxx

 

 

 

matches the RIPSS Block number and yyyyy

 

 

 

matches the RIPSS XID.

 

 

 

For switched connections, the block number must

 

 

 

be 005.

 

 

 

 

Local location

LOCADR

SNA Server Data,

LOC Address (Dec)

address

 

Session Data

The values specified for the RIPSS configuration

 

 

 

 

 

 

must match the values specified on the LOCADR

 

 

 

parameter of the CRTDEVRTL command.

 

 

 

Note that the RIPSS LOC Address is a decimal

 

 

 

value; the AS/400 value is a 2-digit hexadecimal

 

 

 

number.

 

 

 

 

NRZI data

NRZI

SDLC Server Data

Data coding/decoding

encoding

 

 

For SDLC connections, the values specified for the

 

 

 

 

 

 

AS/400 CRTLINSDLC command and the RIPSS

 

 

 

configuration must match:

 

 

 

v If the RIPSS response is NRZI, NRZI(*YES)

 

 

 

must be specified for the CRTLINSDLC

 

 

 

command.

 

 

 

v If the RIPSS response is NRZ, NRZI(*NO) must

 

 

 

be specified for the CRTLINSDLC command.

 

 

 

 

SSCP identifier

SSCPID

HST Server Data

SSCP Name

 

 

 

For SDLC connections, if used, the value specified

 

 

 

by the RIPSS configuration must match the last 10

 

 

 

digits of the SSCPID parameter specified on the

 

 

 

CRTCTLRTL command.

 

 

 

 

Station address

STNADR

SDLC Server Data

Poll address (hex)

 

 

 

For SDLC connections, values specified for the

 

 

 

AS/400 CRTCTLRTL command and the RIPSS

 

 

 

configuration must match.

 

 

 

 

Examples: Connecting AS/400 to a 4690 retail controller

AS/400 retail communications provide the ability to attach retail controllers to the AS/400 system. Retail communications manage data with the intersystem communications function (ICF) file. For communications to begin between programs, the retail communications device must first be configured and varied on.

Example 1: AS/400 to 4690 LU0 connection over token-ring network

Chapter 7. Communicating with remote workstation controllers 75

Example 2: AS/400 to 4690 PEER connection over token-ring network

76 Version 5

Chapter 7. Communicating with remote workstation controllers 77

78 Version 5

Chapter 8. Troubleshooting communications problems

If you suspect you have a problem with communications connectivity, the AS/400 system provides a set of tools to help you with problem analysis tasks. The list below contains some of the more common tools for communications problem analysis.

You can do the following to identify communication problems:

v“Displaying message queues to solve communication problems”

v“Displaying the Product Activity Log to solve communication problems” on page 80

v“Displaying the Print Error Log to solve communication problems” on page 80

You can do the following to solve communication problems:

v“Solving communication problems using communications trace” on page 81

v“Solving communication problems using the system problem log” on page 83

v“Solving communication problems using status information” on page 84

v“Considerations for system tuning during error recovery” on page 84

v“Using error messages to aid in error recovery” on page 84

In addition, when a local system rejects an incoming program start request, a message is sent to the system operator message queue. You can use reason codes to determine why the program start request was rejected.

Displaying message queues to solve communication problems

Message queues receive some messages that are related to communications failures. The message lists possible causes of the problem and additional information, depending on the problem, and the suggested problem analysis tool.

To display message queues, follow these steps:

1.On the AS/400 command line, type DSPMSG MSGQ(XXXX), in which XXXX may be: v The message queue identified by the QCFGMSGQ system value

The default value is QSYSOPR

Or, message queue if the system value has been changed

vFor lines, controllers, and devices which support the MSGQ parameter, the message queue is specified in the configuration object

vFor display devices, the message queue that matches the device name

2.Press the Enter key.

3.In the Display Message display, read the messages pertaining to communications problems that are displayed in the message queue. The object name in the message directs you to the communications objects in error.

4.For messages in the queue with an * in the farthest left position, press F14 to perform additional tests. This calls the Work with Problems tool.

For related information, see:

vMessage queues

v“Solving communication problems using the system problem log” on page 83

v“Job logs and communication problems” on page 80

v“System service tools and communication problems” on page 82

v“Using error messages to aid in error recovery” on page 84

© Copyright IBM Corp. 1998, 2001

79

Displaying the Product Activity Log to solve communication problems

The Print Error Log and the Product Activity Log provide you with important information for solving communications problems.

To view the product activity log, do the following:

1.Display or print the product activity log using these steps:

v Type STRSST (Start System Service Tools) on any AS/400 command line, and press the Enter key. v In the System Service Tools menu, select Option 1 to display or print the product activity log.

For more information about the Product Activity Log, see the Communications Management book.

For related information, see:

vHistory logs

v“System service tools and communication problems” on page 82

v“Using error messages to aid in error recovery” on page 84

Displaying the Print Error Log to solve communication problems

The Print Error Log and the Product Activity Log provide you with important information for solving communications problems.

To view the Print Error Log, do the following:

1.Type PRTERRLOG (Print Error Log) on any AS/400 command line. Press the Enter key.

The command places a formatted printer file of the machine error log in a spooled printer file that is named QPCSMPRT or in a specified output file.

2.Find and read these error logs.

For more information about displaying the Print Error Log, see the Communications Management book.

A variety of job logs may contain information that helps you determine the cause of a communications problem. For a detailed description of these job logs, see: “Job logs and communication problems”

Job logs and communication problems

A variety of job logs may contain information that helps you determine the cause of a communications problem. Many of these logs contain messages that can help you understand what the system has done concerning your communications functions. The following are some of the most useful jobs to review when you have a communications problem:

QSYSARB

System arbiter. This job log is for devices, and communications in general. It also contains ONLINE at IPL messages.

QSYSCOMM1

Communications and input/output system job. This job log is for problem logging and for local area network (LAN) manager messages. It also contains ONLINE at IPL messages for network servers and their lines.

QCMNARB01 through QCMNARB99

Communications arbiter. These job logs contain information for communications startup, take-down, and error recovery.

QLUS Logical unit services.

QLUR Logical unit (LU) 6.2 resynchronization job. This job log is for two-phase commit synchronization processing.

80 Version 5

QPASVRP

Target 5250 display station pass-through primary server job. This job log is for target pass-through communications functions.

QPASVRS

Target 5250 display station pass-through secondary server job. These contain more detailed messages for target pass-through communication functions

Subsystem jobs (QINTER and QCMN)

Interactive subsystem and communication subsystem. These job logs are for subsystem jobs.

For more information on pass-through primary jobs, see the Remote Work Station Support book.

Solving communication problems using communications trace

Sometimes, program debugging tasks are easier if you can trace the data that is sent and received on the communications line or within the network server. To run a communications trace, use the following commands:

STRSST (Start Service Tools)

The STRSST command takes you to a menu of tools to obtain error log information and communications trace information. For a detailed description of system service tools, see: “System service tools and communication problems” on page 82

STRCMNTRC (Start Communications Trace)

The STRCMNTRC command starts a communications trace for the specified line, network interface description, or network server description. The communications trace continues until one of the following occurs:

vThe system runs the End Communications Trace (ENDCMNTRC) command

vA physical line problem causes the trace to end

vThe Communications Trace function of the STRSST command ends the trace

vThe *STOPTRC parameter is specified, and the buffer becomes full

ENDCMNTRC (End Communications Trace)

The ENDCMNTRC command ends the trace currently running on the specified line, network interface description, or network server description. The ENDCMNTRC command saves the communications trace buffer and the associated System Licensed Internal Code (SLIC) data.

PRTCMNTRC (Print Communications Trace)

The PRTCMNTRC command writes the communications trace data for the specified line, network interface description, or network server description to a spooled file or a database file. The system can print trace data multiple times in either form, and parameters on the command allow for dividing and formatting of the data.

DLTCMNTRC (Delete Communications Trace)

The DLTCMNTRC command deletes the communications trace buffer and associated SLIC data for the specified line, network interface description, or network server description. The communications trace can be deleted once the trace has ended.

CHKCMNTRC (Check Communications Trace)

The CHKCMNTRC command returns the communications trace status for a specific line, network interface description, or network server description. The CHKCMNTRC command returns status for all of the traces of a specific type that exist on the system. The system returns the status through a message.

TRCCPIC (Trace Common Programming Interface (CPI) Communications)

You can start to trace Common Programming Interface (CPI) Communications either before running a job or after a job is active to find out where the error might have occurred. The TRCCPIC command captures information about CPI-Communications calls that is processed by your program.

For more information on how to access System Service Tools, see the Backup and Recovery book.

Chapter 8. Troubleshooting communications problems 81

System service tools and communication problems

You may sometimes need to obtain an error log printout or communications trace data that your IBM service representative can review. For the line trace, someone familiar with the protocol used on the line may need to review the files. You can use these additional functions through the system service tools, using the Start System Services Tool (STRSST) command.

Because System Service Tool (SST) also provides other functions, only the correctly authorized user profiles with CRTUSRPRF SPCAUT (*SERVICE) should use the STRSST command. The system-supplied profiles QSECOFR and QSRV have this authority.

Use the communications trace function in the following situations:

vMessage information or other problem analysis is not sufficient to identify a problem

vCommunications support personnel suspects a protocol error

vTo verify that the system sends and receives valid data

You can trace multiple lines from each workstation by using the communications trace option. The system traces a maximum of two lines on the same communications controller subsystem at the same time. Only one trace can exist for the same configuration object at the same time. The system supports all line speeds and protocols.

For more information about these tests, contact your IBM service representative.

Trace Common Programming Interface (CPI) Communications (TRCCPIC) command

You can start to trace Common Programming Interface (CPI) Communications either before running a job or after a job is active to find out where the error might have occurred. The TRCCPIC command captures information about CPI-Communications calls that is processed by your program. The system collects trace information in a current job, or in a job that is serviced by a Start Service Job (STRSRVJOB) command.

(For a CPI Communication program you could trace a job that is started as a result of a received program start request.) You can issue the TRCCPIC command in one of the following ways:

vUsing the System Menu

vTyping TRCCPIC *ON on a command line

vAdding the TRCCPIC command to a control language (CL) or a REstructured eXtended eXecutor (REXX) program

vTyping TRCCPIC on the command line and pressing F4 (Prompt)

If you type TRCCPIC on the command line and press F4, an initial prompt is displayed for the Trace Option Setting. If *ON is specified and you press enter, the Trace CPI Communications display appears.

This display enables you to set the following parameters:

Trace option setting

Specifies whether the collection of trace information is to be started, stopped, or ended.

*ON

Starts Trace CPI Communications. This is the default value for the command.

*OFF

Stops Trace CPI Communications. The current information is written to the spooled printer file or to the database file, and the trace table. The trace information is then deleted.

*END

Ends Trace CPI Communications. The trace table and all trace information are destroyed.

Maximum storage to use

Specifies the maximum amount of storage to use for the trace information collected. The prompt appears only if you have selected *ON for the Trace option setting prompt.

200 K

The number of bytes (1 K equals 1024 bytes) of storage. This is the default value.

82 Version 5

1-16000 K

The valid range for the maximum number of bytes used for storing collected trace information.

Trace full

Specifies whether new trace records replace old trace records or whether the trace is stopped when the maximum storage that you specified has been reached. This prompt appears only if you have selected *ON for the Trace option setting prompt.

*WRAP

When the trace storage area is full, new trace information is written over the old trace information, starting at the beginning of the storage area. This is the default value.

*STOPTRC

No new trace information is saved when the trace storage area is full. You must reissue the TRCCPIC command, specifying (*OFF) for the SET parameter, to retrieve the output of the trace information collected in the trace storage area.

User data length

Specifies the maximum length of user data to be saved for each trace record in the storage area. This prompt affects only the tracing of user data on the Send_Data and Receive calls. This parameter does not affect the tracing of log data on Set_Log_Data, Send_Error, or Deallocate calls. This prompt appears only if you specified *ON on the Trace option setting prompt.

128

The number of bytes for the user data length. This is the default value.

0-4096

The valid range of bytes for the user data length.

Trace Common Programming Interface (CPI) Communications continues to collect trace records until you stop the trace or until the trace storage area becomes full. The amount of trace storage depends on the value that is specified on the Trace full prompt. If the trace storage area becomes full and the collection of trace records stops, you must enter the TRCCPIC command again to create output. The output that is created by the TRCCPIC command is directed either to the spooled printer file, QSYSPRT, or to a database output file that you specify. If the output file that you specify already exists, it must have the same attributes as the system-supplied file, QACM0TRC.

You can stop a trace procedure in one of the following ways:

vUsing the System Menu

vTyping TRCCPIC *OFF on the command line

vAdding the TRCCPIC command to a CL or a REXX program

vTyping TRCCPIC on the command line and pressing F4 (Prompt)

Type TRCCPIC on the command line and press F4. Specify *OFF for the Trace option setting and you are prompted for the OUTPUT parameter.

Solving communication problems using the system problem log

Error conditions that are communications-related can make entries in the system problem log. You can access the log to see the lists of problems that are detected by the system or by the user.

To access the system problem log, type WRKPRB on any AS/400 command line, and press F4.

Tips: You can select a subset of the problems that are listed in the problem log by selecting the problem status. A problem that is listed in the log has one of the following as a status:

vOPENED: The problem was identified; problem analysis has not been run.

vREADY: The system has run problem analysis; the problem is ready to be prepared.

vPREPARED: The system added information that relates to the problem.

vSENT: The problem was sent to the service support location.

Chapter 8. Troubleshooting communications problems 83

You can also sort the WRKPRB display by the date the problem was entered into the log.

Note: Use the WRKPRB command for the menu options, additional problem analysis, or documenting problem records.

Solving communication problems using status information

You can often diagnose the communications problem by checking communications status. Status information for network servers, network interfaces, lines, controllers, or devices may represent the symptom of the problem.

To check and change the communication configuration on the system, do the following:

1.Type the Work with Configuration Status (WRKCFGSTS) command on any AS/400 command line.

2.Press F4. The Work with Configuration Status display appears.

3.Specify the configuration type for the CFGTYPE parameter.

4.Specify the configuration description for the CFGD parameter.

Note: You may subset this list produced by WRKCFGSTS based on the status of the objects using the STATUS parameter. For example, if you want to see just the failed objects, specify STATUS(*FAILED).

Considerations for system tuning during error recovery

The overall performance tuning that is done by the system can play a significant role during error recovery scenarios. For example, you may need to change the machine pool if it is too small because it can cause excessive error recovery times.

vPerformance Adjustment – QPFRADJ

The automatic performance adjustment function of the system is set to 2 when the system is shipped. The system can automatically adjust the performance of the system based on this value. Automatic adjustment may be a desirable feature, particularly when unexpected loads hit the system. Automatic adjustment can help the system perform better through these peak loads.

vSubsystem considerations

You should consider dividing communications users (whether they are remote workstation or APPC communication users) into multiple subsystems. If communications fails, all users who are in a single subsystem may be affected as a result of the communications recovery that is performed on their systems. For more information, see:

– “Considerations for subsystem configuration for error recovery performance” on page 11

Using error messages to aid in error recovery

When problems occur in communications, there are many places you can look for error messages and additional information to help resolve the problems. See the topics below for the most common places to look for APPC error information.

vMessages queues, see “Displaying message queues to solve communication problems” on page 79

vJob logs, see “Job logs and communication problems” on page 80

vOther logs, see “Displaying the Product Activity Log to solve communication problems” on page 80 and “Displaying the Print Error Log to solve communication problems” on page 80

vStart Service tools, see “System service tools and communication problems” on page 82

vCommunications trace, see “Solving communication problems using communications trace” on page 81

Solving communication problems using reason codes

When the local system rejects an incoming program start request, a message is sent to the system operator message queue. You can use the message information to determine why the program start request was rejected.

84 Version 5

Refer to Table 13 for an explanation on reason codes for failed program start requests.

Table 1. Reason Codes for Rejected Program Start Requests

Reason

 

Code

Reason Description

401Program start request received to a device that is not allocated to an active subsystem.

402Requested device is currently being held by a Hold Communications Device (HLDCMNDEV) command.

403User profile is not accessible.

404Job description is not accessible.

405Output queue is not accessible.

406Maximum number of jobs defined by subsystem description are already active.

407Maximum number of jobs defined by communications entry are already active.

408Maximum number of jobs defined by routing entry are already active.

409Library on library list is exclusively in use by another job.

410Group profile cannot be accessed.

411Insufficient storage in machine pool to start job.

412System value not accessible.

413QSERVER not started

501Job description was not found.

502Output queue was not found.

503Class was not found.

504Library on initial library list was not found.

505Job description or job description library is damaged.

506Library on library list is destroyed.

507Duplicate libraries were found on library list.

508Storage-pool defined size is zero.

602 Transaction program-name value is reserved but not supported.

604Matching routing entry was not found.

605Program was not found.

704Password is not valid.

705User is not authorized to device.

706User is not authorized to subsystem description.

707User is not authorized to job description.

708User is not authorized to output queue.

709User is not authorized to program.

710User is not authorized to class.

711User is not authorized to library on library list.

712User is not authorized to group profile.

713User ID is not valid.

714Default user profile is not valid.

715Neither password nor user ID was provided, and no default user profile was specified in the communications entry.

718 No user ID.

722A user ID was received but a password was not sent.

723No password was associated with the user ID.

725User ID does not follow naming convention.

726User profile is disabled.

730 Password has expired.

801Program initialization parameters are present but not allowed.

802Program initialization parameter exceeds 2000 bytes.

803Subsystem is ending.

804Prestart job is inactive or is ending.

805WAIT(NO) was specified on the prestart job entry and no prestart job was available.

806The maximum number of prestart jobs that can be active on a prestart job entry was exceeded.

807Prestart job ended when a program start request was being received.

Chapter 8. Troubleshooting communications problems 85

Table 1. Reason Codes for Rejected Program Start Requests (continued)

Reason

 

Code

Reason Description

901

Program initialization parameters are not valid.

902

Number of parameters for program not valid.

903

Program initialization parameters required but not present.

1001

System logic error. Function check or unexpected return code encountered.

1002

System logic error. Function check or unexpected return code encountered while receiving program

 

initialization parameters.

1501

Character in procedure name not valid.

1502

Procedure not found.

1503

System/36 environment library not found.

1504

Library QSSP not found.

1505

File QS36PRC not found in library QSSP.

1506

Procedure or library name is greater than 8 characters.

1507

Current library not found.

1508

Not authorized to current library.

1509

Not authorized to QS36PRC in current library.

1510

Not authorized to procedure in current library.

1511

Not authorized to System/36 environment library.

1512

Not authorized to file QS36PRC in System/36 environment library.

1513

Not authorized to procedure in System/36 environment library.

1514

Not authorized in library QSSP.

1515

Not authorized to file QS36PRC in QSSP.

1516

Not authorized to procedure in QS36PRC in QSSP.

1517

Unexpected return code from System/36 environment support.

1518

Problem phase program not found in QSSP.

1519

Not authorized to problem phase program in QSSP.

1520

Maximum number of target programs started (100 per System/36 environment).

2501

System logic error. Function check or unexpected return code encountered while processing a program

 

start request.

2502

Temporarily unable to allocate needed resources for a program start request.

2503

No subsystem accepting program start requests for this device.

 

 

86 Version 5

Chapter 9. Networking concepts

If you would like more information on networking topics, review the following:

vAdvanced Peer-to-Peer Networking support

vAdvanced Program-to-Program Communications

vDependent LU Requester Support (DLUR)

vHigh-performance routing (HPR)

vInternet packet exchange support

vSystems Network Architecture

vTCP/IP

Advanced Peer-to-Peer Networking

Advanced Peer-to-Peer Networking (APPN) is one type of data communications support that is provided by the AS/400 system. This support routes data in a network between two or more advanced program-to-program systems. The systems do not need to be directly connected in the same network or adjacent networks.

The APPC/APPN support handles all of the SNA protocol requirements when your system is communicating with a remote system that uses the LU session type 6.2 and node type 2.1 architectures. The remote system can be any of the following systems:

vAS/400 system

vSystem/36

vSystem/38

vIBM personal computer

vDisplaywriter

vSeries/1

v5520 Administrative System

vRISC System/600 (Reduced Instruction Set Computer)

vDPPX/370 (Distribute Processing Programming Executive

vOne of the following host systems:

System/370

System/390

30XX processor

43XX processor

9370 system

Another system that supports the appropriate level of architecture

The AS/400 APPN support is an enhancement to the SNA Node Type 2.1 architecture that supplies networking functions. These enhancements are easy-to-use, are dynamic; and give control of the network to the peer systems that make up the network. APPN provides you with the following advanced functions:

vDistributed directory services

vDynamic route selection that is based on user-specified values

vIntermediate session routing

vRouting of data by using transmission priorities.

With the exception of intermediate session routing, HPR builds on and uses these APPN functions. For more information on HPR, see high-performance routing.

© Copyright IBM Corp. 1998, 2001

87

Advanced program-to-program communications

Advanced program-to-program communications (APPC) is data communications support that allows programs on an AS/400 system to communicate with programs on other systems having compatible communications support, such as: System/38 and System/36. APPC on the AS/400 system provides an application programming interface to the Systems Network Architecture (SNA) LU type 6.2 and node type 2.1 architectures that makes it possible to communicate with System/390.

The APPC support handles all of the SNA protocol requirements when your system is communicating with a remote system that uses the LU type 6.2 and node type 2.1 architectures. You can connect your system to any other system that supports the APPC program interface. APPC application programs can also communicate over lines using the Internet Protocol (IP) of Transmission Control Protocol/Internet Protocol (TCP/IP).

The AS/400 APPC support handles the protocol needed for communicating between an application program that runs on your AS/400 system, and an application that runs on a remote system. The protocol consists of a set of verbs that are common to the local and remote systems in a network. However, the way in which each system provides a program interface to the verbs may differ.

The AS/400 system provides the following program interfaces:

vThe intersystem communications function (ICF) file interface. In ICF, the LU 6.2 verbs are carried out by using data description specifications (DDS) keywords and system-supplied formats.

vThe Common Programming Interface (CPI) Communications call interface. Using CPI Communication calls carries the LU 6.2 verbs.

vThe CICS file interface. In CICS/400 support, the LU 6.2 verbs are carried out by using EXEC CICS commands.

vThe sockets application program interface (API). For the sockets API, the LU 6.2 verbs are carried out by using the socket functions.

The APPC support also handles networking functions, and allows peer systems in a network to start and end sessions without a controlling host system.

The AS/400 Advanced Peer-to-Peer Networking (APPN) support is an enhancement to the node type 2.1 architecture. APPN provides additional networking functions such as searching distributed directories, dynamically selecting routes, routing of intermediate sessions, creating and starting remote locations, and routing data by using transmission priorities.

Built upon APPN, high-performance routing (HPR) is an enhancemnet to APPN that enables improved availability and persistence during network outages.

Dependent LU requester support

Dependent LU Requester Support (DLUR) allows dependent secondary logical units (LU 0, 1, 2, and 3) an entry point into the APPN network. DLUR support gives the appearance of having an adjacent connection to VTAM, but allows traversing the APPN network through intermediate nodes.

DLUR supports the following controllers, displays, and printers:

vHost devices, including 3270 emulation (*EML), remote job entry (*RJE), and program-to-program communications (*PGM)

vSNA Passthrough upstream devices

vDHCF display devices

vNRF display and printer devices

vSNUF devices (DSNX)

The normal SSCP-PU and SSCP-LU flows for dependent LUs are encapsulated in a control point server (CP-SVR) pipe. This pipe consists of two LU 6.2 sessions:

88 Version 5

vSend

vReceive

At the primary end of the pipe is a Dependent LU Server (DLUS). At the secondary end of the pipe is a Dependent LU Requester (DLUR). DLUS and DLUR support the activation and deactivation of dependent physical units (PUs) and logical units (LUs) in the APPN network. The pipe consists of a pair of LU 6.2 conversations where two APPC applications (DLUR and DLUS) exchange dependent SNA SSCP flows. The flows are encapsulated in a general data stream (GDS) variable and sent in LU 6.2 logical records. The pair of conversations that are used to transmit encapsulated SNA is called the CP-SVR Pipe.

To configure DLUR, see the page Configuring Dependent LU Requester.

High-performance routing

High-Performance Routing (HPR) is the evolution of Advanced Peer-to-Peer Networking (APPN). HPR enhances APPN data routing performance and reliability, especially when using higher-speed lower-error links.

To support high-speed communications facilities, certain changes to the APPN architecture are required. These are necessary to allow switching in intermediate nodes to be done at a lower layer and to enable faster switching than in base APPN support. HPR changes the existing APPN intermediate session routing by using automatic network routing (ANR), which maximizes the storage and processing requirement in intermediate nodes. Each outbound packet has a predetermined path through the network so that intermediate routing nodes need not remember anything about HPR sessions that flow through them. Intermediate routing nodes in HPR simply route data that is based on information that is contained within the packet itself.

The HPR function can operate under a base architecture, or can operate under the base architecture plus options. There are performance capabilities available under the Tower RTP option not available with the base. The page, HPR architecture option sets can give you a more thorough explanation of what architecture option is right for you.

HPR architecture option sets

HPR-base option: Its primary function is to provide automatic network routing (ANR). Products that only use this function can participate as intermediate nodes in one or more rapid-transport protocol (RTP) connections. This type of implementation cannot be an end point of an RTP connection.

An addition to the base option is HPR Link-Level Error Recovery. A system that supports high-speed links does not always require link-level error recovery. It is optional because when link-level error recovery is eliminated there can be faster communications when using high-quality data transmission.

RTP Tower Option: Implementations that support this option can act as an endpoint and are able to transport logical unit (LU) to LU session traffic across HPR networks by using RTP connections. An RTP connection can only be made between two systems that support RTP. That is, there can only be a mix of systems in a given RTP connection’s path through the network (ones that only support the HPR base option and ones that support the HPR tower option). However, there is the stipulation that at least the two end points in the path support the HPR tower option. Otherwise, APPN is used.

Note: An implementation that has the RTP Tower Option also supports the base option. These systems can run as intermediate systems in the path.

Internetwork packet exchange support

If your group or business has an established Novell LAN, you can connect AS/400 into your business using the OS/400 Internetwork Packet Exchange (IPX).

Chapter 9. Networking concepts 89

Internetwork Packet Exchange support is the AS/400 implementation of the NetWare communication protocols. These protocols include IPX, Sequenced Packet Exchange (SPX), Router Information Protocol (RIP), Service Advertising Protocol (SAP), and NetWare Link Service Protocol (NLSP). Other related NetWare functions are also included. This set of communications protocols supports peer-to-peer connectivity functions in both local area networks and wide area networks.

What is Systems Network Architecture

In IBM networks, Systems Network Architecture (SNA) is the layered logical structure, formats, protocols, and operational sequences that are used for transmitting information units through networks. SNA also controls the configuration and operation of networks.

APPC, APPN, and HPR are some examples of the protocols included within SNA. They can be used to connect the AS/400 with other IBM systems, or non-IBM systems, to connect remote controllers, and to maintain a high-level of security on your system.

What is TCP/IP

Transmission Control Protocol/Internet Protocol (TCP/IP) is a set of network protocols that enables computers to share resources and exchange information across a network. TCP/IP allows hosts to communicate with each other regardless of the host or user’s physical location, the operating system, or the network medium. TCP/IP operates in many different network environments, that include the Internet and corporate Intranets.

For more information, see the topic TCP/IP configuration fastpath.

90 Version 5

Chapter 10. Common networking standards

These topics introduce the types of common networking standards that are supported by the AS/400 system. See the following topics for more information:

vLocal area network standards

vWide area network standards

Local area network standards

A LAN (local area network) is a communications system that allows interconnection and the sharing of resources between independent devices within a moderately sized geographic area. These topics introduce the types of local area networks that are supported by the AS/400 system:

vAsynchronous transfer mode (ATM)

vDDI (distributed data interface) networks

vEthernet

vToken-ring

vWireless networks

ATM on AS/400

Asynchronous Transfer Mode (ATM) provides a very fast and flexible network protocol. When used with LAN emulation, you can run token-ring and Ethernet on ATM to take advantage of ATM’s superior speed, throughput, and flexibility.

ATM LAN emulation connects LAN clients at multi-megabit-per-second speeds over distances previously possible only with a wide area network (WAN). LAN emulation makes client connections as they are needed, without configuring the physical path between the end systems. Switching is the mechanism by which the network completes connections from one device to another.

The AS/400 asynchronous transfer mode (ATM) network interface (NWI) describes everything that is common across the ATM physical interface. Each AS/400 ATM input/output adapter (2809 or 2810) may have one network interface attached. A single line description attaches to the NWI. The line description can define either an Ethernet or token-ring local area network (LAN) emulation client by using switched virtual circuit connections, permanent virtual circuit connections, or direct connections.

For more information on ATM, see the topic ATM on AS/400.

Distributed data interface network

FDDI is an optical fiber-based local area network (LAN) that uses the American National Standards Institute (ANSI) 3T9.5 standard for a token-passing ring media access control (MAC) protocol. Stations, concentrators, and bridges in a FDDI network are physically connected to one of the counter-rotating rings or both of the counter-rotating rings. The rings operate at 100 Mbps.

FDDI networks allow devices to be attached to one or both of the rings. Usually only the primary ring in a FDDI network is active. The secondary ring is used to maintain the network when a dual-access station or a concentrator becomes inactive.

Ethernet networks

Ethernet is one type of local area network (LAN) topology that is supported by the Operating System/400 licensed program. OS/400 Ethernet provides support for the Digital Equipment Corporation, Intel Corporation, and Xerox standard (Ethernet Version 2) and the IEEE 802.3 standard.

© Copyright IBM Corp. 1998, 2001

91

Half-duplex Ethernet

Generally, multiple stations in an Ethernet network show a single data path. Therefore, only one station may transmit data at a time. This is called half-duplex Ethernet. The station may transmit only or receive only, but not both simultaneously.

Full-duplex Ethernet

Full-duplex Ethernet enables stations to simultaneously send and receive data on the network, eliminating collisions. This is accomplished through the use of a full-duplex LAN switch. Ethernet switching splits a large Ethernet into smaller segments. Full-duplex Ethernet requires the following:

vTwisted-pair cable transmission medium

vEthernet network interface cards

vA full-duplex LAN switch

Full-duplex 10 Mbps ethernet has simultaneous 10 Mbps receiving and 10 Mbps sending paths.

Fast Ethernet

Fast Ethernet is a recently established standard (IEEE 802.3U) that increases Ethernet by operating speeds from 10 Mbps to 100, half or full duplex. AS/400 Ethernet adapters support 100BASE-TX network devices that use category 5 shielded and unshielded twisted-pair (STP, UTP) cable.

For more information, see Ethernet.

Token-ring networks

A token-ring network is one LAN topology that sends data in one direction throughout a specified number of locations by using the token. The token is the symbol of authority for control of the transmission line. This token allows any sending station in the network (ring) to send data when the token arrives at that location.

Stations in a token-ring network are physically connected, usually in a star-wired ring topology, to a wiring concentrator such as the IBM 8228 Multistation Access Unit. The concentrator serves as a logical ring around which data is transmitted at 4 million or 100 million bits per second (Mbps). Each station is connected to the concentrator typically by shielded twisted pair (STP) cabling.

Full-duplex token ring

In full-duplex token ring, which is also called DTR (dedicated token ring), switching hubs enable stations to send and receive data on the network simultaneously. A token-ring switching hub divides the network into smaller segments. When a station transmits its data packet, the token-ring switch reads the packet’s destination address information and forwards the data directly to the receiving station. The switch then establishes a dedicated connection between the two stations, enabling data to be transmitted and received at the same time. In full-duplex token ring, the token-passing protocol is suspended. The network in effect becomes a ’tokenless’ token ring. Full-duplex token ring increases sending and receiving bandwidth for connected stations, improving network performance.

For more information, see Token ring.

Wireless network

The more mobile your employees, the more you should consider a wireless network. The portable transaction computers (PTCs) make it possible for direct connection between the office and offsite locations.

The AS/400 wireless network is a LAN that uses a Carrier Sense Multiple Access with Collision Avoidance (CSMA/CA) protocol to provide media access to competing stations. AS/400 wireless communications use spread-spectrum, direct sequence radio in the 2.4 gigahertz (GHz) band to provide connectivity between

92 Version 5

the AS/400 wireless LAN adapter and remote stations. Remote stations can be PTCs that are running 5250 emulation or LAN-connected systems that are equipped with compatible wireless adapters. There are other implementations of wireless LAN.

Wide area network standards

A wide area network (WAN) is a data communications network designed to serve an area of hundreds or thousands of miles--for example, public and private packet-switching networks, and national telephone networks.

These topics introduce the types of wide area networks that are supported by the AS/400 system:

vAsynchronous communications

vBinary synchronous communications

vFrame relay

vIntegrated services digital network

vSynchronous data link control network

vX.25 network

vX.21 network

Asynchronous communications

OS/400 asynchronous communications support allows an AS/400 application program to exchange data with a remote system or device using either an asynchronous (start-stop) or X.25 line. AS/400 application programs can be written in ILE COBOL/400, ILE RPG/400, ILE C/400, or FORTRAN/400 languages. Asynchronous communications support includes file transfer support (also used with other communications types) and interactive terminal facility (ITF). Asynchronous communications support provides program-to-program and program-to-device communications between systems that use asynchronous (start-stop) or X.25 lines. For X.25 lines, it also supplies an integrated packet assembler/disassembler (PAD) (1) that follows CCITT recommendations X.3, X.28, and X.29.

Asynchronous communications support allows you to send data to and receive data from a remote program or device attached by either an asynchronous (start-stop) or an X.25 line. Your application program must provide the data stream required by the remote device. Asynchronous communications support packages your data stream in either a start-stop format or within X.25 data packets.

Binary synchronous communications

(BSC) is a data communications line protocol that uses a standard set of transmission control characters and control character sequences to send binary-coded data over a communications line. Binary synchronous communications equivalence link (BSCEL) support is the intersystem communications function (ICF) support on the AS/400 system that provides binary synchronous communications with a remote system or device. BSCEL also supplies online and batch communications between application programs on different BSC systems. AS/400 application programs can be written in the Integrated Language Environment (ILE) C/400*, ILE COBOL/400*, ILE FORTRAN/400*, or ILE RPG/400* programming languages.

Frame relay networks

Frame relay is a protocol that defines how frames are routed through a fast-packet network based on the address field in the frame. Frame relay takes advantage of the reliability of data communications networks to minimize the error checking done by the network nodes. This provides a packet-switching protocol similar to, but much faster than, X.25. The high speed that can be obtained through frame-relay networks makes it well suited for wide area network (WAN) connectivity. Frame relay is commonly used to connect two or more LAN bridges over large distances.

The AS/400 system supports these frame-relay network connections:

Chapter 10. Common networking standards 93

vFrame relay direct network: Allows data that uses SNA, TCP/IP, or IPX communications over a frame-relay network to move at speeds of up to 2.048 Mbps. This support allows a network of systems to communicate using the frame-relay network as a backbone, without the need for multiple leased T1 lines.

vBridged frame relay network: Allows AS/400 to communicate over a frame-relay network through a remote bridge. The bridge is attached to a token-ring, Ethernet, or distributed data interface (DDI) network. Bridged frame relay connections allow AS/400 to communicate with stations on the remote local area network (LAN) as if they were attached locally to the LAN medium.

For more information, see Frame relay.

Integrated services digital network

You can connect your AS/400 to an Integrated Services Digital Network (ISDN) for faster, more accurate data transmission. An ISDN is a public or private digital communications network that can support data, fax, image, and otherservices over the same physical interface. Also, you can use other protocols on ISDN, such as ISDN data link control (IDLC), PPP, fax, and X.25.

ISDN provides benefits that are not found in more conventional types of communications. These include the following:

vHigh speed, low error rate communications

vSwitched, high speed communications

vSwitched, digital networking

vAdvanced networking functions

vIntegration of voice and data transmissions

vIntegrated support of packet switching (X.31)

For more information on ISDN, see the topics ISDN on AS/400 and ISDN data link control network.

ISDN data link control network

You can use ISDN data link control (IDLC) to connect two systems to exchange information over an ISDN B-channel.

IDLC complies with the data link control protocols that are defined in CCITT Recommendations Q.921 and Q.922. IDLC defines a set of protocol rules and formats for use on D-channels and B-channels. On the D-channel, IDLC provides a reliable link with the network equipment. On the B-channel, IDLC provides a reliable link with another end user.

Similar to other data link protocols, IDLC has special considerations for operation:

vIDLC parameters used to establish the logical connection

vDelayed contact for permanent connection

vFrame size related to performance

vDisconnect parameters for a switched IDLC controller

Synchronous data link control network

SDLC has the following meanings:

vA form of communications line control that uses commands to control the transfer of data over a communications line.

vA communications discipline that conforms to subsets of the Advanced Data Communication Control Procedures (ADCCP) of the American National Standards Institute (ANSI) and high-level data link control (HDLC). These standards are part of the International Organization of Standardization.

SDLC is used for transferring synchronous, code-transparent, serial-by-bit information over a communications line. Transmission exchanges may be duplex or half-duplex over switched or nonswitched lines. The configuration of the connection may be point-to-point, multipoint, or loop.

94 Version 5