www.hyundai-hvac.com

2.

 

 

Electric air conditioner (split system)

 

CONTENTS

 

 

 

 

 

 

1.Important information

 

3

 

2.Safeguards

 

3

 

3.Specifications

 

4

 

4.Appliance description

 

6

 

5.Delivery set

 

6

 

6.Appliance control

 

7

 

Control panel for indoor unit

 

8

 

Remote control board

 

9

 

7.Operating modes

 

9

 

8.Maintenance

 

10

 

 

 

 

 

 

EN

Electric air conditioner (split system)

 

3.

 

Dear Customer!

Thank you for a shrewd choice and purchase of Hyundai portable electric air conditioner. It will serve you for a long time.

1. IMPORTANT INFORMATION

The appliance is designed for air cooling in domestic premises. The manufacturer reserves the right to introduce changes in design, configuration and processing of the article with a view to improve its properties without any prior notification of customers. There may be some misprints in text and digital notations of the present manual.

If after reading of this manual you have any questions concerning work and operation of the appliance, please, refer to a shop assistant or to a specialized service center for further explanations.

The article has a label with all the needed technical data and other useful information about the appliance. Use the appliance only for its intended purpose indicated in this manual.

2. SAFEGUARDS

1.Don’t try to install the conditioner by yourself. Call for a qualified installation specialist.

2.While using the air conditioner, it is necessary to observe several precautions. Incorrect opera-

tion due to ignoring of precautions may result in personal injury of a user and other people, as well as in damaging of their property.

3.The electric appliance should be under observation while operated, especially if there are any children near it.

4.Don’t pass your fingers or foreign objects through an air outlet grille of indoor and outdoor units, since it may result in a trauma caused by a revolving fan.

5.Don’t let children turn the conditioner on by themselves. Children may turn the conditioner on only under the care of adults.

6.Don’t try to repair the conditioner by yourself. Internal units of the conditioner carry a voltage and it is life-threatening! For repair of the appliance refer to an authorized service center.

7.Don’t use the appliance if it is faulty, or if it was dropped or damaged.

8.Don’t open a front panel of the appliance during its work.

9.Don’t dismantle and modify the appliance.

10.Unplug the conditioner immediately, if it emits strange odours or smoke.

11.Don’t splash and pour water and other liquids on the conditioner.

12.Always unplug the conditioner during a lighting storm.

13.Always unplug the conditioner, when it is not used.

14.Before cleaning and maintenance of the conditioner unplug it. Cleaning and maintenance should be performed in accordance with instructions of this manual.

15.To ensure the effective work of the conditioner, operate it in environment described in the present manual.

16.Don’t use dangerous chemicals for cleaning of the appliance and don’t let them on the appliance.

17.When removing an air filter, don’t touch metal parts of the appliance.

18.To avoid overheating and risk of flash fire, as well as damage of internal electric network, don’t change the length of a power cord and don’t connect the appliance via extension cords.

19.To avoid electrical hazards, damaged power cord must be changed only at authorized service centers qualified professionals.

20.To avoid risk of electric shock, do not place the power cord near a heater and flammable or combustible substances.

21.Do not start or stop the unit by connecting or disconnecting electrical power.

22.To avoid electric shock, a damaged power cord should be replaced only in authorized service centers by qualified specialists.

23.To avoid electric shock, don’t place the power cord near heating appliances and flammable or combustible substances.

24.Don’t start and stop the appliance by power-up and down.

25.Don’t press the buttons of the remote control board by anything but your fingers.

26.Don’t use the appliance for purposes not intended by this user manual.

EN

Hyundai H-ARI17-07H/I, H-ARI17-09H/I, H-ARI17-12H/I, H-ARI17-18H/I, H-ARI17-24H/I User Manual

4.

3.SPECIFICATIONS

Electric air conditioner (split system)

EN

Tab.1

 

 

Indoor unit

H-ARI17-07H/I

H-ARI17-09H/I

Outdoor unit

H-ARI17-07H/О

H-ARI17-09H/О

 

 

 

Capacity (cooling) BTU (kW)

Capacity (heating) BTU (kW)

Rated power consumption (cooling) (W) Rated power consumption (heating) (W) Power supply V/Hz

Rated power current (cooling/heating) A Air circulation (indoor unit) m3/h

Air circulation (outdoor unit) m3/h

Noise level (indoor unit) dB(A)

Noise level (outdoor unit) dB(A)

Refrigerant

Energy efficiency (cooling/heating) Electrical protection class

Degree of protection against moisture (indoor unit)

Degree of protection against moisture (outdoor unit)

Refrigerant piping, Liquid side / Gas side, (inch) Max. refrigerant pipe length, m

Maximum difference in level, m

Filling of Freon, g

Operating temperature range: cooling, ° C Operating temperature range: heating, ° C Net weight, indoor unit (kg)

Net weight, outdoor unit (kg)

Gross weight, indoor unit (kg)

Gross weight, outdoor unit (kg)

Net dimensions, indoor unit (mm) Net dimensions, outdoor unit (mm) Packing dimensions, indoor unit (mm) Packing dimensions, outdoor unit (mm)

7677 (2,25)

9383 (2,75)

8121 (2,38)

9827 (2,88)

681

829

652

785

220~/50

220~/50

2,96/2,83

3,60/3,41

550

550

1980

2500

36/34/32

36/34/32

51

52

R410A

R410A

A/A

A/A

I class

I class

IPXO

IPXO

IPX4

IPX4

1/4 / 3/8

1/4 / 3/8

15

15

10

10

700

830

+18°~+43°

+18°~+43°

-15°~+24°

-15°~+24°

77

26

28

8,15

8,15

23,0

23,0

770×240×180

770×240×180

700x256x552

700x256x552

805×305×255

805×305×255

803×325×585

803×325×585

Electric air conditioner (split system)

 

5.

 

Indoor unit

H-ARI17-12H/I

H-ARI17-18H/I

H-ARI17-24H/I

Outdoor unit

H-ARI17-12H/О

H-ARI17-18H/О

H-ARI17-24H/О

 

 

 

 

 

Capacity (cooling) BTU (kW)

11942 (3,5)

17913 (5,25)

23884 (7,0)

Capacity (heating) BTU (kW)

12454 (3,65)

18766 (5,5)

24566 (7,2)

Rated power consumption (cooling) (W)

1038

1563

2148

Rated power consumption (heating) (W)

981

1426

1997

Power supply V/Hz

220~/50

220~/50

220~/50

Rated power current (cooling/heating) A

4,51/4,27

6,8/6,2

9,34/8,68

Air circulation (indoor unit) m3/h

650

750

1000

Air circulation (outdoor unit) m3/h

2500

2800

2800

Noise level (indoor unit) dB(A)

38/36/34

42/40/38

42/40/38

Noise level (outdoor unit) dB(A)

53

58

58

Refrigerant

R410A

R410A

R410A

Energy efficiency (cooling/heating)

A/A

A/A

A/A

Electrical protection class

I class

I class

I class

Degree of protection against moisture

IPXO

IPXO

IPXO

(indoor unit)

 

 

 

Degree of protection against moisture

IPX4

IPX4

IPX4

(outdoor unit)

 

 

 

Refrigerant piping, Liquid side / Gas side, (inch)

1/4 / 3/8

1/4 / 1/2

1/4 / 1/2

Max. refrigerant pipe length, m

20

20

20

 

Maximum difference in level, m

15

15

15

Filling of Freon, g

1150

1150

1150

Operating temperature range: cooling, ° C

+18°~+43°

+18°~+43°

+18°~+43°

Operating temperature range: heating, ° C

-15°~+24°

-15°~+24°

-15°~+24°

Net weight, indoor unit (kg)

8,5

11,0

13,0

Net weight, outdoor unit (kg)

28,0

40,0

43,0

Gross weight, indoor unit (kg)

9,5

12,0

14,0

Gross weight, outdoor unit (kg)

29,0

35,0

53,0

Net dimensions, indoor unit (mm)

800×280×185

1033×313×202

1033×313×202

Net dimensions, outdoor unit (mm)

760×256×552

780×290×605

820×300×605

Packing dimensions, indoor unit (mm)

855×305×255

985×365×298

1103×400×300

Packing dimensions, outdoor unit (mm)

803×325×585

863×325×585

930×380×635

EN

6.

 

Electric air conditioner (split system)

4. APPLIANCE DESCRIPTION

3

11

10

2

 

7

 

8

1

4

 

 

9

 

 

6

5

 

Fig. 1

EN

The conditioner consists of indoor and outdoor units connected by pipelines. The conditioner may be controlled from a remote control board or from an indoor unit control panel.

1.Conditioner unit for indoor installation.

2.Front panel.

3.Air-intake grille of the indoor unit.

4.Control panel (start/stop button, mode selection button) if there is no remote control board.

5.Blinds (deflectors) for distribution of treated air.

6.Air outlet of the indoor unit.

7.Copper tube for gas (freon), connection line*.

8.Tube for condensate removal*.

9.Air-outlet grille of the outdoor unit.

10.Conditioner unit for outdoor installation.

11.Air-intake grilles of the outdoor unit.

5. DELIVERY SET

Complete set of air conditioner (split system) includes: Conditioner unit for indoor installation -1 piece Conditioner unit for outdoor installation -1 piece Remote control board -1 piece

Batteries for remote control board - 2 pcs. User manual -1 piece

Guarantee slip -1 piece

Packing of indoor-installation unit -1 piece Packing of outdoor-installation unit -1 piece

* not supplied

Electric air conditioner (split system)

 

7.

 

6. DEVICE CONTROL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 2. Description of indoor unit control panel

 

The conditioner may be controlled from a remote control board or from an indoor unit control

 

panel.

 

If the remote control board is lost or cannot be used at the moment, you may use a control

EN

button «on/off» located behind the front panel.

For that, open the front panel carefully by pulling it from the left and right.

 

1.

Press once to activate the automatic mode.

 

2.

Press again within five seconds to activate the forced cooling mode.

 

The front panel of air conditioner there is a display that shows the current temperature and defined, and indicators* display modes and settings: power, night mode, temperature, timer, compressor operation (see Fig. 3**).

The front panel of the conditioner comprises a display showing specified and current temperature, as well as indicators* reflecting modes and parameters of work: power supply, sleep mode, temperature, timer, compressor operation (see Fig. 3**).

* Presence of this function depends on the delivery lot.

Timer

Sleep indicator

 

8.

b

TIMER

 

ECO

 

 

 

 

 

 

 

SUPER

SLEEP

 

 

 

 

 

 

 

 

HEALTH

OPTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAN

SWING

 

h

Fig. 3

REMOTE CONTROL

1

 

7

 

 

TIMER

ECO

EN

 

 

SUPER

SLEEP

 

 

6

 

 

 

 

 

HEALTH

OPTION

 

 

 

 

5

 

 

 

 

 

FAN

SWING

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

MODE

 

 

 

 

9

Fig. 4

a

c

d e

f j

8

10

3

11

4

Electric air conditioner (split system)

а) Temperature indicator b) Indicators timer

с) Indicator operation indicator functions

d)Indicators Cooling

e)Indicators dry

f)Indicators fan

j) Indicators heat h) Indicators speed

* use of particular indicators depends on model and series.

** design of indicator symbols may differ depending on model and series.

1.Button “ON/OFF” (Power). Using this button, you may turn the conditioner on or off.

2.Button for selection of operating mode - “MODE”. Using this button, you may select a needed operating mode: AUTO, COOL, DRY, HEAT, FAN.

3.Button “SLEEP”. Using this button, you may turn the sleep mode on and off. In this mode the fan speed will be low.

4.Button “SWING”.Using this button, you may regulate position of air-outlet blinds and forward treated air up and down, left and right.

5.Button “Health. Using this button, you may turn on or off the ion funtion. (In this model the function is not available).

6.Button “SUPER”. With this button you can enable or disable the intensive mode. When swithing modes, or when you increase / decrease the fan speed, the function is automatically disabled.

7.Button “TIMER”. This button sets the automatic swich-on (set the desired time by pressing button “SET”, “MODE”, “SPEED” or button “TIMER”). The device automatically turns on after a selected period of time.

8.Button “INDICATORS LIGHT”. Using this button you may disable the backlight of the display of the indoor unit. By re-pressing the button, you can turn on the display backlight.

9.Кнопка «INCREASE THE TEMPERATURE». With this button, you can control the temperature.

10.Button «ECO».

11.Button «OPTION». This option is not available for conditioner H-AR10-H.

Work with remote control board

Indication of the control board display shall correspond to selected modes.

Mounting and replacement of batteries: mount two LR03 alkaline batteries, according to polarity indicated on the remote

Electric air conditioner (split system)

 

9.

 

control board.

In order to avoid malfunction of the remote control board do not insert used batteries or batteries of various types.

If the conditioner is not used for a long time, remove batteries from the board or else electrolyte may leak and damage the board.

In normal operation of the conditioner average service life of batteries will be about a half-year. Replace batteries, if command receiving is not confirmed with an audio signal, or if the display does not show a sign of command transfer. When generating commands from the remote control board, point an IR-radiator at a remote-control signal receiver situated on the indoor unit. Hold the remote control board at the distance of no more than 8 m from the indoor unit. The remote control board will not work, if there are any curtains, doors or other things between it and the indoor unit. Protect the board from water and exposure to direct sunlight and heat sources.

7. OPERATING MODES

AUTO mode

The auto mode is turned on and off with the use of the button «MODE» on the remote control board.

During operation in this mode, the air conditioner automatically selects the cooling/heating/ fan mode maintaining the set temperature.

COOL, HEAT and FAN EN

1.Turn the conditioner on pressing the «ON/OFF» button.

2.Pressing the «MODE» button, select COOL, HEAT or FAN mode manually.

3.Pressing the «TEMP» button (up-down), set the desired air temperature indoors (except for FAN mode).

4.Pressing the «FAN SPEED» button on the remote control board, select the fan rotation speed: AUTO, LOW, MIDDLE, HIGH, and the conditioner will start working in accordance with the selected setting.

5.To turn the conditioner off, press the «ON/OFF» button once again.

In the FAN mode air temperature indoors is not set.

DRY

Turn the conditioner on pressing the «ON/OFF» button. Pressing the “MODE” button, select the DRY mode. The conditioner will start working in the set mode. To turn the conditioner off, press the «ON/OFF» button once again.

When indoor temperature decreases to 10°C, the air conditioner is automatically switched off and it resumes work after increase of temperature up to 12°C.

TIMER mode

Procedure of timing:

1.Press the Timer ON button to activate Timer ON. Each time you press the button you increase the activation time by 30 minutes ranging from 0 to 10 hours and by 1 hour ranging from 10 to

10.

 

Electric air conditioner (split system)

24 hours. The air conditioner will switch on automatically in the set interval of time.

2.Press the Timer OFF button to activate Timer OFF. Each time you press the button you increase the activation time by 30 minutes ranging from 0 to 10 hours and by 1 hour ranging from 10 to 24 hours. The air conditioner will switch off automatically in the set interval of time.

SLEEP mode

Using this button you may turn on or off the sleep mode. When the key pressed in the cooling mode increases the temperature relative to the set at one degree per hour for two hours and in heating mode lowers the temperature at two degrees per hour for two hours. After 7 hours working in this mode, the air conditioner will turn off.

When the power is turned off, the sleep mode is automatically disabled.

Regulation of treated air flow direction

Regulating the position of deflectors (blinds), set the direction of treated air flow ensuring uniform distribution of temperature and the most comfort conditions in the room. To change the position of deflectors, use the «SWING» button.

8. MAINTENANCE

EN

Before cleaning unplug the conditioner.

Cleaning of the indoor unit and remote control board:

Indoor unit and remote control board should be cleaned with a dry soft cloth.

If the indoor unit is too unclean, moisten the cloth with cold water.

It is prohibited to clean the remote control board with moist cloth.

In order to avoid the damage of paint or details of the conditioner, do not clean it with brushes and do not leave them on the surface of indoor unit.

In order to avoid the damage of surface or deformation of the conditioner details, do not clean it with petrol, solvents, cleaning powders or other chemically active substances.

Before a sustained interruption in the conditioner work:

Turn the conditioner on for several hours in the FAN mode. It will allow you to dry its inner cavities

Unplug the conditioner. Remove the batteries from the remote control board. Checks before starting:

Make sure that an air filter is installed.

Make sure that air inlet and outlet grilles of the outdoor unit are not blocked by foreign objects.

Cleaning of air filter

Air filter cleans the air entering the conditioner from dust and foreign particles. If the filter is contaminated, the conditioner capacity decreases sharply.

If the conditioner is operated permanently, the filter should be cleaned once per two weeks.

If the conditioner is installed in a room with dusty atmosphere, then the air filter should be cleaned more often.

To remove the filter, open the indoor unit panel.

Remove air filters. Clean the filter with a vacuum cleaner or rinse it in clean water. If the filter is contaminated heavily, clean it with a soft brush and wash in diluted washing solution, then dry it in a cool place.

While cleaning the filter with the vacuum cleaner, hold it with contaminated surface up. While washing the filter in water, hold it with contaminated surface down.

Do not dry the filter in the sun or near a fire.

Set the air filter to initial position and close the panel.

Electric air conditioner (split system)

 

11.

 

EN

12.

 

 

Электрический кондиционер воздуха (сплит-система)

 

Содержание

 

 

 

 

 

 

 

1.

Важная информация

 

13

2.

Меры предосторожности

 

13

3.

Технические характеристики

 

14

4.

Описание прибора

 

16

5.

Комплект поставки

 

16

6.

Управление прибором

 

17

 

 

Панель управления внутреннего блока

18

 

 

Пульт дистанционного управления (ПДУ)

19

7.

Режимы работы

 

19

8.

Уход и обслуживание

 

20

9.

Гарантийный талон

 

22

RU

Loading...
+ 28 hidden pages