HP MSA50 User Manual 2

0 (0)
HP MSA50 User Manual 2

QuickSpecs

HP StorageWorks Modular Smart Array 50

Enclosure

Overview

The HP StorageWorks Modular Smart Array 50 Enclosure MSA50 is a 1U Serial Attach SCSI(SAS) disk drive storage enclosure supporting Small Form Factor(SFF) SAS or Serial ATA(SATA) drives. This enclosure delivers industry-leading data performance, availability, storage density, and upgradeability to meet customers' demanding and growing storage needs. The all new SFF drive carrier is designed to support the new Universal form factor hard drive in either SAS or SATA. This new form factor provides optimized performance per U of space while delivering unparalleled power consumption. The MSA50 enclosure supports direct attach storage to HP ProLiant and Integrity Servers. The MSA50 supports the cascading of shelves in a 1+1 configuration to allow a maximum of 20 SFF drives in a 2U configuration attached to a single controller port. This single controller port incorporates four lanes for a total max throughput of 12Gb/s for SAS.

1.

Expansion slot for potential future second I/O

6.

Power button/LED

2.

Fan

7.

UID button/LED

3.

Hot-plug power supply

8.

Hot-plug SAS or SATA hard drive bays

4.

Hot-plug power supply

9.

Access panel

5.

I/O module

 

 

 

 

 

 

Models

The MSA50 design allows for the mix of SAS and SATA drives in the same enclosure at the same time and is tailored to the needs of HP server customers who require optimized performance per U of rack space.

Model MSA50

HP StorageWorks Modular Smart Array 50

Enclosure (NA,EMEA,AP)

364430-B21

 

NOTE: Rack-mountable 10 SFF drive enclosure with single I/O module,

 

 

redundant hot plug power supplies and hot plug fans.

 

 

HP StorageWorks Modular Smart Array 50

Enclosure (Japan)

364430-291

NOTE: Rack-mountable 10 SFF drive enclosure with single I/O module, redundant hot plug power supplies and hot plug fans.

NOTE: For complete compatibility information, refer to the Specifications section of this document. SAS/SATA performance requires a compatible SAS controller. This is noted in the product documentation.

DA - 12245 Worldwide — Version 11 — May 25, 2007

Page 1

QuickSpecs

HP StorageWorks Modular Smart Array 50

Enclosure

Product Highlights

Customer Benefits

Higher Performance

The Serialized nature of SAS combined with the highest spindle count

 

per U of Rack Space

per U of rack space allows the MSA50 to achieve the greatest I/Os per

 

 

second when compared to parallel SCSI.

 

Price Sensitivity

The MSA50 will be the first SAS/SATA SFF JBOD product that will offer

 

 

a level of availability sufficient for the Enterprise and a price structure

 

 

that is attractive to SMB.

 

Investment Protection

The MSA50 has the future potential to upgrade from 3GB to 6GB SAS,

 

 

as well as mix and match SAS or SATA drives within the same

 

 

enclosure. Thus making technology transitions simple and cost

 

 

effective.

 

Reduced Spares

Universal SFF drives and similar physical characteristics between SAS

 

Inventory

and SATA drives allow customers to mix/match SAS and SATA in the

 

 

same enclosure and allow the same drives to be used in servers and

 

 

external storage.

 

 

Key Features

Features of the MSA50 include:

 

SFF (SAS/SATA) support – Delivering data transfer rates up 3Gb/s for SAS and 1.5Gb/s for

 

SATA

 

 

NOTE: SAS/SATA performance requires a compatible SAS controller. This is noted in the product

 

documentation.

 

 

1U rack height.

 

 

Supports up to 10 SFF SAS and/or SATA Universal hard disk drives.

 

Provides storage capacity of up to 1.4TB per enclosure (using 146GB 10K disk drives)

 

Cascadable 1+1 for up to 20 spindles in a 2U configuration or 2.8TB.

 

Modular design allows the MSA50 to be used in any storage configuration from JBOD (Just

 

a Bunch of Disks) to Smart Array storage enclosures.

 

A common storage platform allows the potential for future storage consolidation to the SAN.

 

Universal SFF SAS drive carrier – provides better cooling and reliability for by providing

 

increased air flow through the storage unit.

 

Hot pluggable disk drives, fans and power supplies.

 

Field replaceable fans, I/O Module and mid plane

 

Easy removal of parts provides better serviceability. No tools are required!

Upgradeability

Potential Upgrade path for a HP StorageWorks MSA50 is as easy as swapping out the I/O Module

 

on the back of the unit. The unit must be powered down to replace the I/O Module.

 

 

 

Mix and Match of Hard A benefit of SAS and SATA is the use of a common physical connection which allows for both

Drive Types

drive types to be mixed together on the same backplane. This common backplane allows

 

customers the choice of using SAS and/or SATA and helps deliver HP's message of industry

 

leading innovation, reliability, adaptability, and performance by allowing customers to choose the

 

reliability of SAS or the lower cost of SATA for tiered storage.

 

 

Hot Pluggable

Hot pluggable technology is designed into drives, fans and redundant power supplies. Hot

 

pluggable components can be replaced without powering down the storage system or stopping I/O

 

operations. This feature significantly enhances data availability.

 

 

DA - 12245 Worldwide — Version 11 — May 25, 2007

Page 2

QuickSpecs

HP StorageWorks Modular Smart Array 50

Enclosure

Product Highlights

Auto SAS ID Selection

SAS ID is automatically set when a drive is inserted into a drive bay (See drawing on top of unit

 

for bay numbering).

 

 

LED Indicators

Front panel LEDs indicate drive activity, required drive service, and power, giving a quick visual

 

assessment of overall system storage status.

 

 

Rack Density

The MSA50 Enclosure has a 1U height.

 

 

Environment

Each MSA50 model is equipped with an EMU that constantly monitors the enclosure, the power

Monitoring Unit (EMU)

supplies, and fans to ensure suggested operating tolerances are maintained.

 

 

I/O Module

The single I/O module installed allows one SAS controller to access all drives in the MSA50.

 

 

Fault Tolerance

With redundant power supplies and fans, the MSA50 provides a high level of system availability.

 

Using an internal host based controller, the MSA50 can be configured for RAID levels 0, 1, 1 + 0,

 

5, 6 (RAID ADG) when using a HP Smart Array RAID controller.

 

 

Manageability

The MSA50 is managed by HP Systems Insight Manager.

 

 

Compatibility and

Intensive compatibility and performance testing with HP ProLiant servers ensures the highest level

Integration Testing

of integration available in the industry. For a complete list of supported HP servers and

 

workstations, please refer to the QuickSpecs and/or User Guide of the array controller or Host Bus

 

adapter that you are planning to use. The list of supported array controllers and SAS adapters is

 

provided under "Related Options, Controllers".

 

 

Product Kit Contents

Redundant power supplies, single I/O module, 9 drive blanks, warranty card, mounting hardware,

 

Enclosure user guide, HP SmartStart CD Kit, documentation CD, one 2 Meter SAS external cable

 

and two Nema 5-15 to C13 and two IEC320-C14 to -C13 power cords.

 

NOTE: The included SAS cable is only for the P600 controller.

 

If connecting to a Smart Array P800 or a Smart Array E500 controller one of the following cables

 

must be ordered:

 

SAS 4x to Mini SAS 4x 2M – 419571-B21

 

SAS 4x to Mini SAS 4x 4M – 419572-B21

 

SAS 4x to Mini SAS 4x 6M – 419573-B21

 

 

Warranty

MSA50: 3/0/0 limited warranty.

 

NOTE: Certain restrictions and exclusions apply.

 

Hard drive Pre-Failure Warranty: When used with any one of the StorageWorks Smart Array

 

Family controllers and monitored under HP Systems Insight Manager (v4.20 or later), HP hard

 

drives are supported by a Pre-Failure (replacement) Warranty.

DA - 12245 Worldwide — Version 11 — May 25, 2007

Page 3

Loading...