QuickSpecs
HP StorageWorks Modular Smart Array 30 Single Bus or Dual Bus Enclosures
(formerly known as HP StorageWorks 4400 Enclosure)
The HP StorageWorks Modular Smart Array 30 Single Bus or Dual Bus Enclosures (hereafter referred to as "MSA30 SB or MSA30 DB") is an Ultra320 SCSI disk drive storage enclosure. These enclosures deliver industry-leading data performance, availability, storage density, and upgradeability to meet customers' demanding and growing storage needs. The drive carrier is designed to support the fastest current Ultra320 hard drives on the same SCSI bus. The ease of upgrading the StorageWorks 4200 or the StorageWorks 4300 Enclosure to the MSA30 proves that HP provides the lowest cost of ownership. The MSA30 SB and DB enclosures support HP Integrity and HP ProLiant servers in addition to HP 9000 and HP Alpha Servers. Proving that technology transitions can proceed smoothly without disrupting critical business environments
The MSA30 OVSM HA kit ships with a 60 day trial license of OpenView Storage Mirroring software. This product also includes two 72GB 15K rpm Ultra320 hard drives. When configured with a ProLiant server, IT administrators can perform tasks such as OS Migration, disaster recovery and server consolidation. Administrators can move file servers to new servers without incurring downtime and while using available bandwidth. This solution allows customers to keep the target and host units in production mode while allowing the migration of data simultaneously. MSA30 OVSM HA kit will allow the administrator to manage bandwidth during the migration process to maximize I/O on critical servers during off-peak hours.
NOTE: For more information on OpenView Storage Mirroring please go to the following link:
http://h18006.www1.hp.com/products/storage/software/sm/index.html.
Models
The MSA30 design allows for specific configurations tailored to the needs of all HP server customers. The models are available today:
Model MSA30 SB |
Rack-mountable 14 drive enclosure with single bus, redundant power supplies |
302969-B21 |
|
Model MSA30 DB |
Rack-mountable 14 drive enclosure with dual bus, redundant power supplies |
302970-B21 |
|
|
|
|
|
Customer Benefits |
Higher Performance |
Ultra320 SCSI transfer rates combined with the highest spindle count |
|
|
|
per U of rack space allows the MSA30 to achieve the greatest I/Os per |
|
|
|
second. |
|
|
Storage Capacity |
3U rack form factor allows customer to achieve the maximum storage |
|
|
|
capacity per square foot in the data center. |
|
|
Upgradeability |
Ultra320 single and dual I/O upgrade modules make upgrading the |
|
|
|
StorageWorks 4200/4300 Enclosure to Ultra320 quick and easy. |
|
|
|
NOTE: U320 performance requires a compatible U320 controller. This is |
|
|
|
noted in the product documentation. |
|
|
Investment Protection |
With the ability to upgrade, as well as mix and match, existing |
|
|
|
Ultra2and/or Ultra3 components with Ultra320, HP makes technology |
|
|
|
transitions simple and cost effective, and has simplified the transition to |
|
|
|
the next generation SCSI protocol. |
|
|
Reduced Spares |
Universal drives and drive carriers across HP's entire Ultra2, Ultra3, and |
|
|
Inventory |
Ultra320 product offering allow the same drives to be used in servers |
|
|
|
and external storage. |
|
|
|
|
|
DA - 11738 Worldwide QuickSpecs — Version 25 — 6.8.2007 |
Page 1 |
QuickSpecs
HP StorageWorks Modular Smart Array 30 Single Bus or Dual Bus Enclosures
Overview
Key Features |
NOTE: All models of the MSA30 (Formerly StorageWorks 4400) Enclosure Family have the |
|
following features: |
|
Ultra320 (LVD) support - Delivering data transfer rates up to 320 MB/s per channel |
|
NOTE: U320 performance requires a compatible U320 controller. This is noted in the product |
|
documentation. |
|
3U rack height. |
|
Supports up to 14 (1-inch) Ultra320 (as well as legacy Ultra3 and Ultra2 drives) Universal |
|
hard disk drives. |
|
Provides storage capacity of up to 4.2TB per enclosure (using 300GB 1-inch disk drives) |
|
Modular design allows the MSA30 to be used in any storage configuration from JBOD (Just |
|
a Bunch of Disks) to Smart Array storage enclosures to external RAID arrays. Up to 14 |
|
enclosures can be mounted in one 42U rack for a single rack storage capacity of up to |
|
28.4TB of disk storage (JBOD configuration) or up to 12 enclosures in an EMA16000 |
|
(HSG80 configuration) for a single rack storage capacity of 24.4TB. |
|
A common storage platform allows for future storage consolidation to the SAN. |
|
Award-winning innovative SCA (Single Connect Attach) direct connect drive carrier - |
|
provides better cooling and reliability for 10K and 15K drives. |
|
Hot pluggable disk drives, power supplies, and fans. |
|
Redundant fans, dual power supplies and single or dual bus I/O module options. |
|
Environmental Monitoring Unit (EMU) - Monitors environmental conditions within the |
|
enclosure and components such as the power supplies and fans. |
|
NOTE: A U320 compatible EMU is required for a U320 I/O module. This is included with a MSA30 |
|
but must be deployed if an upgrade option kit is purchased for a StorageWorks 4200/4300 |
|
Enclosure. |
|
Easy removal of parts provides better serviceability. No tools are required! |
DA - 11738 Worldwide QuickSpecs — Version 25 — 6.8.2007 |
Page 2 |
QuickSpecs
HP StorageWorks Modular Smart Array 30 Single Bus or Dual Bus Enclosures
Upgradeability |
Upgrading a StorageWorks 4200/4300 Enclosure to a MSA30 is as easy as swapping out the I/O |
|
module and the EMU on the back of the unit. The unit must be powered down to replace the I/O |
|
unit. |
|
NOTE: U320 performance requires a compatible U320 controller. This is noted in the product |
|
documentation. A U320 compatible EMU is also required for upgrades to U320 I/O modules. |
|
|
Mix and Match |
All Ultra320, Ultra3, and Ultra2 devices from HP are compatible with one another so customers |
|
can mix and match components in the same storage enclosure or server. When Ultra2, Ultra3, |
|
and Ultra320 devices are found on the same Ultra320 SCSI bus, each device will transfer data at |
|
its individual interface transfer rate up to the transfer rate of the SCSI bus. (Requires an Ultra320 |
|
controller for each drive to reach maximum I/Os as listed here.) |
|
NOTE: For customers who operate legacy Models 4310R and 4350R enclosures, the use of 1- |
|
inch Universal Ultra2, Utlra3, or Ultra320 disk drives requires the addition of 0.6-inch drive |
|
extenders. For configurations using the PCI-X Dual Channel U320 SCSI HBA, (P/N A7173A), |
|
mixing disks types (U160 and U320) is not supported in the same MSA30 enclosure. |
|
|
Hot Pluggable |
Hot pluggable technology is designed into drives, redundant power supplies and redundant |
|
cooling fans. Hot pluggable components can be replaced without powering down the storage |
|
system or stopping I/O operations. This feature significantly enhances data availability. |
|
|
Auto SCSI ID Selection SCSI ID is automatically set when a drive is inserted into a drive bay.
LED Indicators |
LED indicators provide a quick visual assessment of overall system storage status. The MSA30 |
|
|
has three LEDs in the front, for EMU Status, power and fault. LED status and fault indicators for |
|
|
the fans and power supplies are located in the back of the enclosure. |
|
|
|
|
Rack Density |
The MSA30 models have a 3U height. |
|
|
|
|
Environment |
Each MSA30 model is equipped with a hot-pluggable EMU that constantly monitors the enclosure, |
|
Monitoring Unit (EMU) |
the power supplies, and fans to ensure suggested operating tolerances are maintained. |
|
|
NOTE: A U320 compatible EMU is required for a U320 I/O module. |
|
|
|
|
Single Bus I/O Module |
The single bus I/O module allows one SCSI channel to access all drives in the MSA30. |
|
|
|
|
Dual Bus I/O Module |
The dual bus I/O module allows two SCSI channels to access a single MSA30. This allows for |
|
|
greater fault tolerance (controller duplexing) or provides access from two different servers to two |
|
|
separate storage areas. |
|
|
|
|
Fault Tolerance |
With the dual bus I/O module, redundant power supplies and fans, the MSA30 provides a high |
|
|
level of system availability. Using an internal or external RAID Array, the MSA30 can be |
|
|
configured for RAID levels 0, 1, 1+0, 5 and RAID 6 with ADG when using a HP Smart Array RAID |
|
|
controller. |
|
|
|
|
Manageability |
Depending on the host controller, the MSA30 is managed by HP Insight Manager or |
|
|
StorageWorks Command Console. |
|
|
|
|
DA - 11738 Worldwide QuickSpecs — Version 25 — 6.8.2007 |
Page 3 |
QuickSpecs
HP StorageWorks Modular Smart Array 30 Single Bus or Dual Bus Enclosures
Product Highlights
Compatibility and Intensive compatibility and performance testing with HP ProLiant severs, HP Integrity, HP 9000 Integration Testing Servers and Alpha servers ensures the highest level of integration available in the industry on a
HP server. For a complete list of supported HP servers and workstations, please refer to the QuickSpecs and/or User Guide of the array controller or Host Bus adapter that you are planning to use. The list of supported array controllers and SCSI adapters is provided under "Related Options, Controllers".
Product Kit Contents Model MSA30 SB |
Redundant power supplies, single bus I/O module, 14 drive blanks, |
|
warranty card, mounting hardware, Enclosure 4400 user guide, EMU |
|
booklet, HP SmartStart CD Kit, documentation CD, one 12-ft VHDCI to |
|
VHDCI SCSI cables and two Nema 5-15 to C13 and two IEC320-C14 to |
|
-C13. |
Model MSA30 DB |
Redundant power supplies, dual bus I/O module, 14 drive blanks, |
|
warranty card, mounting hardware, Enclosure 4400 user guide, EMU |
|
booklet, HP SmartStart CD Kit, documentation CD, two 12-ft VHDCI to |
|
VHDCI SCSI cables and two Nema 5-15 to C13 and two IEC320-C14 to |
|
-C13. |
NOTE: A different SCSI cable may be required when the MSA30 is intended for connection to an HSG80 controller in a Model 2200 controller enclosure or a host-based adapter on an Alpha server. See the Related Options section of this document for cable ordering information.
NOTE: Power cord for Japan will be included in orders marked for Japan.
NOTE: To maintain proper cooling and airflow, a drive blank or drive must occupy all bays during operation.
Warranty |
MSA30: Three-year limited warranty. Limited warranty includes 3 year parts, 0 years labor, 0 years |
|
on-site support. |
|
NOTE: Certain restrictions and exclusions apply. |
|
Hard drive Pre-Failure Warranty: When used with any one of the StorageWorks Smart Array |
|
Family controllers and monitored under HP Insight Manager (v4.20 or later), HP hard drives are |
|
supported by a Pre-Failure (replacement) Warranty. |
|
NOTE: Pre-Failure Warranty is available on all HP ProLiant servers using HP Insight Manager |
|
v4.20 or later, and covers Pentium Pro processors, ECC memory, server hard drives, and external |
|
storage enclosure hard drives (except the 535 MB Fast-SCSI-2 hard drive) using HP IDA, IDA-2, |
|
HP SMART SCSI Array Controllers, HP SMART-2 Array Controllers or HP Smart Array |
|
Controllers. Certain restrictions and exclusions apply. |
DA - 11738 Worldwide QuickSpecs — Version 25 — 6.8.2007 |
Page 4 |