Hoshizaki KM-1900SRH-3, KM-1900SWH-3, KM-1900SAH-3 User Manual

0 (0)

HoshizakiHoshizaki America, Inc.

Stackable Crescent Cuber

Models

KM-1900SAH/3

KM-1900SWH/3

KM-1900SRH/3

“A Superior Degree

of Reliability”

INSTRUCTION MANUAL

www.hoshizaki.com

Issued: 1-6-2009

Revised: 11-8-2010

IMPORTANT

Only qualified service technicians should install, service, and maintain the icemaker. No installation, service, or maintenance should be undertaken until the technician has thoroughly read this Instruction Manual. Likewise, the owner/ manager should not proceed to operate the icemaker until the installer has instructed them on its proper operation. Failure to install, operate, and maintain the equipment in accordance with this manual may adversely affect safety, performance, component life, and warranty coverage.

Hoshizaki provides this manual primarily to assist qualified service technicians in the installation, maintenance, and service of the icemaker.

Should the reader have any questions or concerns which have not been satisfactorily addressed, please call, write, or send an e-mail message to the Hoshizaki Technical

Support Department for assistance.

HOSHIZAKI AMERICA, INC.

618 Highway 74 South

Peachtree City, GA 30269

Attn: Hoshizaki Technical Support Department

Phone: 1-800-233-1940 Technical Support (770) 487-2331

Fax: 1-800-843-1056 (770) 487-3360

E-mail: techsupport@hoshizaki.com

Web Site: www.hoshizaki.com

NOTE: To expedite assistance, all correspondence/communication MUST include the following information:

Model Number ________________________

Serial Number ________________________

Complete and detailed explanation of the problem.

2

IMPORTANT

 

This manual should be read carefully before the icemaker is installed and

 

operated. Only qualified service technicians should install, service, and

 

maintain the icemaker. Read the warnings contained in this booklet carefully as

 

they give important information regarding safety. Please retain this booklet for

 

any further reference that may be necessary.

 

CONTENTS

 

Important Safety Information..................................................................................................

4

I. Specifications......................................................................................................................

5

A. Nameplate Rating..........................................................................................................

5

1. KM-1900SAH (air-cooled).........................................................................................

5

2. KM-1900SAH3 (air-cooled).......................................................................................

6

3. KM-1900SWH (water-cooled)...................................................................................

7

4. KM-1900SWH3 (water-cooled).................................................................................

8

5. KM-1900SRH (remote air-cooled)............................................................................

9

6. KM-1900SRH3 (remote air-cooled)........................................................................

10

B. Dimensions/Connections..............................................................................................

11

1. KM-1900SAH/3........................................................................................................

11

2. KM-1900SWH/3.....................................................................................................

12

3. KM-1900SRH/3......................................................................................................

13

II. Installation and Operating Instructions.............................................................................

14

A. Checks Before Installation...........................................................................................

14

B. How to Remove Panels................................................................................................

14

C. Location.......................................................................................................................

15

D. Setup...........................................................................................................................

15

E. Installation of Upper Unit.............................................................................................

17

F. Electrical Connection....................................................................................................

19

G. Installation of Remote Condenser Unit........................................................................

21

1. Checks Before Installation......................................................................................

21

2. Location..................................................................................................................

21

3. Setup......................................................................................................................

22

4. Line Set..................................................................................................................

22

5. Refrigerant Charge (Line Set Exceeding 66 Feet).................................................

25

6. Electrical Connection.............................................................................................

25

7. Stacking Condenser Unit........................................................................................

26

H. Water Supply and Drain Connections..........................................................................

27

1. Icemaker.................................................................................................................

28

2. Water-Cooled Condenser.......................................................................................

29

I. Final Checklist ..............................................................................................................

31

J. Startup..........................................................................................................................

32

III. Cleaning and Maintenance..............................................................................................

33

A. Cleaning and Sanitizing Instructions ...........................................................................

33

1. Cleaning Procedure................................................................................................

34

2. Sanitizing Procedure - Following Cleaning Procedure............................................

35

B. Maintenance Instructions.............................................................................................

36

C. Preparing the Icemaker for Long Storage....................................................................

36

3

Important Safety Information

Throughout this manual, notices appear to bring your attention to situations which could result in death, serious injury, or damage to the unit.

WARNING

Indicates a hazardous situation which could result in death or

 

serious injury.

CAUTION

Indicates a situation which could result in damage to the unit.

IMPORTANT

Indicates important information about the use and care of the

 

unit.

WARNING

This icemaker should be destined only to the use for which it has been expressly conceived. Any other use should be considered improper and therefore dangerous. The manufacturer cannot be held responsible for injury or damage resulting from improper, incorrect, and unreasonable use.

To reduce the risk of death, electric shock, serious injury, or fire, follow basic precautions including the following:

Electrical connection must be hard-wired and must meet national, state, and local electrical code requirements. Failure to meet these code requirements could result in death, electric shock, serious injury, fire, or severe damage to equipment.

This unit requires an independent power supply. See the nameplate for proper voltage and breaker/fuse size. Failure to use a proper breaker or fuse can result in a tripped breaker, blown fuse, or damage to existing wiring. This could lead to heat generation or fire.

THIS UNIT MUST BE GROUNDED. Failure to properly ground this unit could result in death or serious injury.

This unit should be disassembled or repaired only by qualified service personnel to reduce the risk of electric shock, injury, or fire.

Do not make any alterations to the unit.Alterations could result in electric shock, injury, fire, or damage to the unit.

4

I. Specifications

A. Nameplate Rating

1. KM-1900SAH (air-cooled)

HOSHIZAKI ICE MAKER

MODEL NUMBER

KM-1900SAH

SERIAL NUMBER

208-230/60/1 (3 WIRE WITH

AC SUPPLY VOLTAGE

COMPRESSOR

NEUTRAL FOR 115V)

230V 11.3RLA 73LRA

PUMP

120V 1.2FLA 60W

FAN

115V 2FLA(TOTAL) 60W

OTHER

115V

0.3A

MAXIMUM FUSE SIZE

30

AMPS

MAX. HACR BREAKER(USA ONLY)

30

AMPS

MAX. CIRC. BREAKER (CANADA ONLY)

30

AMPS

MINIMUM CIRCUIT AMPACITY

30

AMPS

DESIGN PRESSURE

HI-467PSI LO-230PSI

REFRIGERANT

404A 4 LB. 10.1 OZ.

MOTOR-COMPRESSOR THERMALLY PROTECTED,

NOT INTENDED FOR OUTDOOR USE!

HoshizakiAmerica, Inc.

Peachtree City, GA

www.hoshizaki.com

ICE MAKER WITHOUT

STORAGE MEANS

946Z COMPONENT

See the nameplate for electrical and refrigeration specifications. This nameplate is located on the rear panel.

Since this nameplate is located on the rear panel of the icemaker, it cannot be read when the back of the icemaker is against a wall or against another piece of kitchen equipment. Therefore, the necessary electrical and refrigeration information is also on the rating label, which can be easily seen by removing only the front panel of the icemaker.

We reserve the right to make changes in specifications and design without prior notice.

5

2. KM-1900SAH3 (air-cooled)

HOSHIZAKI ICE MAKER

MODEL NUMBER

KM-1900SAH3

SERIAL NUMBER

208-230/60/3

AC SUPPLY VOLTAGE

COMPRESSOR

230V 8.4RLA 66LRA

PUMP

120V 1.2FLA 60W

FAN

115V 2FLA(TOTAL) 60W

OTHER

115V

0.3A

MAXIMUM FUSE SIZE

20

AMPS

MAX. HACR BREAKER(USA ONLY)

20

AMPS

MAX. CIRC. BREAKER (CANADA ONLY)

20

AMPS

MINIMUM CIRCUIT AMPACITY

20

AMPS

DESIGN PRESSURE

HI-467PSI LO-230PSI

REFRIGERANT

404A 4 LB. 10.1 OZ.

MOTOR-COMPRESSOR THERMALLY PROTECTED,

NOT INTENDED FOR OUTDOOR USE!

HoshizakiAmerica, Inc.

Peachtree City, GA

www.hoshizaki.com

ICE MAKER WITHOUT

STORAGE MEANS

946Z COMPONENT

See the nameplate for electrical and refrigeration specifications. This nameplate is located on the rear panel.

Since this nameplate is located on the rear panel of the icemaker, it cannot be read when the back of the icemaker is against a wall or against another piece of kitchen equipment.

Therefore, the necessary electrical and refrigeration information is also on the rating label, which can be easily seen by removing only the front panel of the icemaker.

We reserve the right to make changes in specifications and design without prior notice.

6

3. KM-1900SWH (water-cooled)

HOSHIZAKI ICE MAKER

MODEL NUMBER

KM-1900SWH

SERIAL NUMBER

208-230/60/1 (3 WIRE WITH

AC SUPPLY VOLTAGE

COMPRESSOR

NEUTRAL FOR 115V)

230V 11.1RLA 73LRA

PUMP

120V 1.2FLA 60W

FAN

115V

- - -

OTHER

0.3A

MAXIMUM FUSE SIZE

30

AMPS

MAX. HACR BREAKER(USA ONLY)

30

AMPS

MAX. CIRC. BREAKER (CANADA ONLY)

30

AMPS

MINIMUM CIRCUIT AMPACITY

30

AMPS

DESIGN PRESSURE

HI-427PSI LO-230PSI

REFRIGERANT

404A 3 LB. 1.4 OZ.

MOTOR-COMPRESSOR THERMALLY PROTECTED,

NOT INTENDED FOR OUTDOOR USE!

HoshizakiAmerica, Inc.

Peachtree City, GA

www.hoshizaki.com

ICE MAKER WITHOUT

STORAGE MEANS

946Z COMPONENT

See the nameplate for electrical and refrigeration specifications. This nameplate is located on the rear panel.

Since this nameplate is located on the rear panel of the icemaker, it cannot be read when the back of the icemaker is against a wall or against another piece of kitchen equipment. Therefore, the necessary electrical and refrigeration information is also on the rating label, which can be easily seen by removing only the front panel of the icemaker.

We reserve the right to make changes in specifications and design without prior notice.

7

4. KM-1900SWH3 (water-cooled)

HOSHIZAKI ICE MAKER

MODEL NUMBER

KM-1900SWH3

SERIAL NUMBER

208-230/60/3

AC SUPPLY VOLTAGE

COMPRESSOR

230V 7.8RLA 66LRA

PUMP

120V 1.2FLA 60W

FAN

115V

- - -

OTHER

0.3A

MAXIMUM FUSE SIZE

20

AMPS

MAX. HACR BREAKER(USA ONLY)

20

AMPS

MAX. CIRC. BREAKER (CANADA ONLY)

20

AMPS

MINIMUM CIRCUIT AMPACITY

20

AMPS

DESIGN PRESSURE

HI-427PSI LO-230PSI

REFRIGERANT

404A 3 LB. 1.4 OZ.

MOTOR-COMPRESSOR THERMALLY PROTECTED,

NOT INTENDED FOR OUTDOOR USE!

HoshizakiAmerica, Inc.

Peachtree City, GA

www.hoshizaki.com

ICE MAKER WITHOUT

STORAGE MEANS

946Z COMPONENT

See the nameplate for electrical and refrigeration specifications. This nameplate is located on the rear panel.

Since this nameplate is located on the rear panel of the icemaker, it cannot be read when the back of the icemaker is against a wall or against another piece of kitchen equipment. Therefore, the necessary electrical and refrigeration information is also on the rating label, which can be easily seen by removing only the front panel of the icemaker.

We reserve the right to make changes in specifications and design without prior notice.

8

5. KM-1900SRH (remote air-cooled)

HOSHIZAKI ICE MAKER

MODEL NUMBER

KM-1900SRH

SERIAL NUMBER

208-230/60/1 (3 WIRE WITH

AC SUPPLY VOLTAGE

COMPRESSOR

NEUTRAL FOR 115V)

230V 11.4RLA 73LRA

PUMP

120V 1.2FLA 60W

FAN REMOTE

120V 3A MAX

OTHER

115V

0.3A

MAXIMUM FUSE SIZE

30

AMPS

MAX. HACR BREAKER(USA ONLY)

30

AMPS

MAX. CIRC. BREAKER (CANADA ONLY)

30

AMPS

MINIMUM CIRCUIT AMPACITY

30

AMPS

DESIGN PRESSURE

HI-467PSI LO-230PSI

REFRIGERANT

 

404A

MOTOR-COMPRESSOR THERMALLY PROTECTED,

NOT INTENDED FOR OUTDOOR USE!

HoshizakiAmerica, Inc.

Peachtree City, GA

www.hoshizaki.com

ICE MAKER WITHOUT

STORAGE MEANS

946Z COMPONENT

See the nameplate for electrical and refrigeration specifications. This nameplate is located on the rear panel.

Since this nameplate is located on the rear panel of the icemaker, it cannot be read when the back of the icemaker is against a wall or against another piece of kitchen equipment. Therefore, the necessary electrical and refrigeration information is also on the rating label, which can be easily seen by removing only the front panel of the icemaker.

We reserve the right to make changes in specifications and design without prior notice.

9

6. KM-1900SRH3 (remote air-cooled)

HOSHIZAKI ICE MAKER

MODEL NUMBER

KM-1900SRH3

SERIAL NUMBER

208-230/60/3

AC SUPPLY VOLTAGE

COMPRESSOR

230V 8.0RLA 66LRA

PUMP

120V 1.2FLA 60W

FAN REMOTE

120V 3A MAX

OTHER

115V

0.3A

MAXIMUM FUSE SIZE

20

AMPS

MAX. HACR BREAKER(USA ONLY)

20

AMPS

MAX. CIRC. BREAKER (CANADA ONLY)

20

AMPS

MINIMUM CIRCUIT AMPACITY

20

AMPS

DESIGN PRESSURE

HI-467PSI LO-230PSI

REFRIGERANT

 

404A

MOTOR-COMPRESSOR THERMALLY PROTECTED,

NOT INTENDED FOR OUTDOOR USE!

HoshizakiAmerica, Inc.

Peachtree City, GA

www.hoshizaki.com

ICE MAKER WITHOUT

STORAGE MEANS

946Z COMPONENT

See the nameplate for electrical and refrigeration specifications. This nameplate is located on the rear panel.

Since this nameplate is located on the rear panel of the icemaker, it cannot be read when the back of the icemaker is against a wall or against another piece of kitchen equipment. Therefore, the necessary electrical and refrigeration information is also on the rating label, which can be easily seen by removing only the front panel of the icemaker.

We reserve the right to make changes in specifications and design without prior notice.

10

Hoshizaki KM-1900SRH-3, KM-1900SWH-3, KM-1900SAH-3 User Manual

B. Dimensions/Connections

1. KM-1900SAH/3

Unit: in. [mm]

Note: When used with a storage bin not recommended by Hoshizaki, the icemaker needs the space at the bottom opening as in the illustration.

11

2. KM-1900SWH/3

Unit: in. [mm]

Note: When used with a storage bin not recommended by Hoshizaki, the icemaker needs the space at the bottom opening as in the illustration.

12

Loading...
+ 26 hidden pages