T4031A,B,P; T6031A,B

Refrigeration Temperature Controllers

GENERAL

The T4031A,B,P and T6031A,B are temperature controllers used in a variety of cooling applications where remote mounting of the sensing element in the controlled medium is required.

PRODUCT DATA

FEATURES

Wide control temperature range is suitable for controlling ducts, tanks, freezers, coolers, display cases. and defrost termination.

Universal mounting bracket is available for easy replacement of other controllers.

Models are available with various control ranges.

Control setpoint is dial-knob adjustable.

Models are available with fixed or adjustable temperature differentials.

Capillary lengths are 5, 8, or 20 ft (1.5, 2.4, 6.1m) depending on model.

Reliable snap-acting spst or spdt switch.

Ambient temperature compensated.

Insert supplied with TRADELINE® models replaces setpoint knob to discourage tampering.

 

Contents

General ..................................................................................

1

Features ................................................................................

1

Specifications.........................................................................

2

Ordering Information ..............................................................

2

Installation .............................................................................

3

Operation and Checkout ........................................................

5

Copyright © 1995 Honeywell Inc. • All Rights Reserved

60-2177-3

T4031A,B,P; T6031A,B REFRIGERATION TEMPERATURE CONTROLLERS

SPECIFICATIONS

IMPORTANT

The specifications given in this publication do not include normal manufacturing tolerances. Therefore, this unit may not exactly match the specifications listed. Also, this product is tested and calibrated under closely controlled conditions, and some minor differences in performance can be expected if those conditions are changed.

TRADELINE® Models

TRADELINE® models are selected and packaged to provide ease of stocking, ease of handling, and maximum replacement value. TRADELINE® model specifications are the same as those of standard models except as noted below.

TRADELINE® Model Available:

T6031A Refrigeration Temperature Controller-spdt switch, adjustable temperature differential, tamper-resistant insert.

Capillary Lengths and Temperature Ranges:

Capillary Length:

8 ft (2.4m)

Additional Features:

TRADELINE® pack with cross reference label and special instructions

Standard Models

T4031A Refrigeration Temperature Controller-spst switch makes on temperature rise; fixed differential

T4031B Refrigeration Temperature Controller—same as T4031A but less case

T4031P Refrigeration Temperature Controller—same as T4031A but uses screw, not knob, to adjust setpoint T6031A Refrigeration Temperature Controller-spdt switch,

fixed or adjustable temperature differential

T6031B Refrigeration Temperature Controller—same as T6031A but less case

Switch Action:

T4031A,B,P spst switch makes R to W on temperature rise T6031A,B spdt switch makes R to W on temperature rise,

R to B on temperature fall

 

 

 

 

 

 

 

 

 

Copper

 

 

 

 

 

 

Capillary

Setting Rangea

 

 

 

 

Tube Length

Differential

 

Model

ft

m

°F

°C

°F

°C

 

 

 

 

 

 

 

 

 

T4031A,B

5

1.5

-30 to 50

-34 to 10

Fixed at 3.5

Fixed at 1.6

 

 

 

 

 

 

 

 

 

 

20

6.1

 

 

 

 

 

 

 

 

 

 

 

 

 

T4031P

8

2.4

-30 to +90

-34 to +32

3.5 to 16

1.6 to 9

 

 

 

 

 

 

 

 

 

T6031A,B

5

1.5

-15 to +90

-9 to +32

Fixed at 3.5 or Adjust. from 3.5 to 12

Fixed at 1.6 or Adjust. from 1.6 to 7

 

 

 

 

 

 

 

 

 

 

20

6.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

1.5

-30 to +50

-34 to +10

 

 

 

 

 

 

 

 

 

 

 

 

20

6.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

2.4

-30 to +90

-34 to +32

 

 

 

 

 

 

 

 

 

 

 

a Dial scale markings in degrees Fahrenheit

ORDERING INFORMATION

When purchasing replacement and modernization products from your TRADELINE® wholesaler or your distributor, refer to the TRADELINE® catalog or price sheets for complete ordering number, or specify:

1.

Order number.

4.

Length of copper capillary tube.

2.

Setting range.

5.

Accessories, if desired.

3.

Fixed or adjustable differential (T6031).

 

 

If you have additional questions, need further information, or would like to comment on our products or services, please write or phone:

1.Your local Honeywell Home and Building Control Sales office (check white pages of your phone directory).

2.Home and Building Control Customer Relations Honeywell, 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386

In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world.

60-2177—3

2

T4031A,B,P; T6031A,B REFRIGERATION TEMPERATURE CONTROLLERS

Electrical Ratings:

 

 

 

 

 

 

120 Vac

240 Vac

 

 

 

 

 

 

Normally

Normally

Normally

Normally

 

Closed

Opena

Closed

Opena

Full Load

8

16

5.1

8

Amp

 

 

 

 

 

 

 

 

 

Locked Rotor

48

80

30.6

40

Amp

 

 

 

 

 

 

 

 

 

a Makes on temperature rise.

Pilot Duty:

125 VA

Dimensions:

See Fig. 1

2 (51)

KNOCKOUT FOR 1/2 IN. (13 MM) 15/16 CONDUIT (2)

(24)

17/32

2-1/4

(57)

 

 

(13)

2-1/8

(54)

 

4-3/16

5-5/8

(107)

(136)

7/32

(6)

7/32 (6) DIA. (3)

3/8 (10) DIA. (3)

29/32

(23)

3/8

1-3/16

M4496

(9)(30)

Fig. 1. Dimensions of T4031, T6031 in in. (mm).

Underwriters Laboratories Inc.:

Listed

Maximum Ambient Operating Temperature:

125°F (52°C)

Accessories:

112622AA Immersion Well—short-necked, 1/2 in. NPT, copper

7617ABY Compression Fitting—50 psi water, 15 psi air 107324A Bulb Holder—for duct installation

105900 T-strap—for strapping bulb to pipe

7617ABZ Bag Assembly—for mounting controller to fan coil units

801534 Calibration Wrench

7640HY Standoff Bracket Bag Assembly—to mount controller to an insulated duct

130883 Universal Mounting Bracket

194899 Tamper-resisting Insert Button Celsius Scaleplates:

194486 D: -15°C to +35°C replaces (0°F to 100°F) scaleplate

194486H: 15°C to 75°C replaces (55°F to 175°F) 194486F: 75°C to 125°C replaces (160°F to 260°F)

INSTALLATION

When Installing this Product…

1.Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition.

2.Check the ratings given in the instructions and on the product to make sure the product is suitable for your application.

3.Installer must be a trained, experienced service technician.

4.After installation is complete, check out product operation as provided in these instructions.

CAUTION

Disconnect power supply before installation to prevent electrical shock and equipment damage.

Do not damage or change shape of capsule. Deformed capsule will cause calibration offset.

Mounting

Install controller in any convenient location. Make sure that the sensing bulb reaches the system to be controlled. The ambient temperature must not exceed 125°F (52°C) in the area where the controller is installed.

Install the sensing element where it can sense the average temperature. Avoid sharp bends or kinks in the capillary tubing that can affect the accuracy of the controller. Carefully coil the excess capillary tubing and leave it directly beneath the controller.

The 130883 Mounting Plate furnished with TRADELINE® models allows the control to be mounted in existing mounting holes.

Duct Installation

Position the sensing bulb in the duct to sense the average air temperature. Avoid mounting the bulb close to hot pipes, cooling coils, etc.

The 107324A Bulb Holder is available for suspending the bulb in a duct. See Fig. 2.

3

60-2177—3

Loading...
+ 5 hidden pages