Operating
Manual
PRO TH4000 Series
Programmable Thermostat
69-1760EFS-01
ENGLISH
Quick Reference Card
Grasp and pull to see basic operating instructions at a glance.
This manual covers the following models:
TH4110D: For 1 Heat/1 Cool systems
TH4210D: For 2 Heat/1 Cool heat pump systems only
(Pull thermostat from wallplate and turn over to find model number.)
MCR29469
CAUTION: EQUIPMENT DAMAGE HAZARD.
To prevent possible compressor damage, do not operate cooling system when outdoor temperature is below 50°F (10°C).
Need Help?
For assistance with this product please visit http://yourhome.honeywell.com or call Honeywell Customer Care toll-free at 1-800-468-1502
Read and save these instructions.
® U.S. Registered Trademark. Patents pending. Copyright © 2009 Honeywell International Inc. All rights reserved.
69-1760EFS—01
PRO TH4110D / TH4210D
Table of contents |
|
About your new thermostat |
|
Thermostat features................................... |
2 |
Programming at a glance........................... |
3 |
Quick reference to controls....................... |
4 |
Quick reference to display......................... |
5 |
Programming & Operation |
|
Set time and day........................................ |
6 |
System switch (Heat/Cool)......................... |
7 |
Fan switch (Auto/On).................................. |
8 |
Using program schedules.......................... |
9 |
Program schedule overrides.................... |
12 |
Adaptive Intelligent Recovery™.............. |
14 |
Compressor protection............................ |
15 |
Appendices |
|
Battery replacement................................. |
16 |
In case of difficulty................................... |
17 |
Customer assistance................................ |
19 |
Accessories.............................................. |
19 |
5-year limited warranty............................ |
20 |
This thermostat is ready to go!
Your new thermostat is pre-programmed and ready to go.
See page 3 to check settings.
ENGLISH
1 |
69-1760EFS—01 |
Operating Manual
ENGLISH
About your new thermostat
Your new Honeywell thermostat has been designed to give you many years of reliable service and easy-to-use, push-button climate control.
Features
•Separately programmable weekday/weekend schedules.
•One-touch temp control overrides program schedule at any time.
•Energy Star® compliant to greatly reduce your heating/cooling expenses.
•Large, clear, backlit display is easy to read.
•Displays both room temperature and temperature setting.
•Built-in compressor protection.
2
69-1760EFS—01
PRO TH4110D / TH4210D
This thermostat is ready to go!
Your new thermostat is pre-programmed. Just set the time and day. Then check the settings below and change if needed:
1. |
Set time and day (required for proper operation)......................... |
See page 6 |
2. |
Select system setting: Preset to Off.................................................. |
See page 7 |
3. |
Select fan setting: Preset to Auto...................................................... |
See page 8 |
4.Program schedules: Preset to energy-saving levels (assumes you wake at 6 am, leave at 8 am, return
at 6 pm and sleep at 10 pm)........................................................ |
See pages 11-13 |
ENGLISH
ONE-TOUCH TEMP CONTROL: You can override the program schedule at any time, and manually adjust the temperature (see pages 12-13).
3 |
69-1760EFS—01 |
Operating Manual
ENGLISH
Quick reference to controls
Temperature adjustment (see page 11-13)
• Set: Press to set time/day/ schedule.
• Hold: Press to override programmed temperature control.
• Run: Press to resume program schedule.
Fan Switch (see page 8) On: Fan runs continuously.
Auto: Fan runs only when heating or cooling system is on.
|
System switch (see page 7) |
|
|
• Cool: Cooling system control. |
|
M29470 |
• Off: All systems off. |
|
• Heat: Heating system control. |
||
|
||
|
• Em Heat: Emergency & Auxiliary |
|
|
Heat control. Compressor is |
|
|
locked out. (Select models only.) |
69-1760EFS—01 |
4 |
PRO TH4110D / TH4210D
Quick reference to display screen
Low battery warning
(see page 16)
Current inside temperature
Current program period
Wake/Leave/Return/Sleep
(see pages 9-10)
Adaptive Intelligent RecoveryTM
(see page 14)
|
Replace Batt |
|
|
Set To |
|
Inside |
|
||
|
|
75 |
||
75 |
|
Recovery |
||
|
|
|||
|
6:30 AM |
Em Aux |
||
|
Wake |
|
Heat On |
|
|
Wed |
|
|
|
|
|
|
|
|
M29471
Current day/time (see page 6)
Temperature setting
(see pages 11-13)
System status Cool on: Cooling system is on.
Heat on: Heating system is on.
Em: Emergency heat is on.**
Aux: Auxiliary heat is on.**
ENGLISH
**Only for heat pumps with this capability (select models only).
5 |
69-1760EFS—01 |
Operating Manual
Set the time and day
ENGLISH |
Press SET, then adjust time. |
Set |
|
|
Clock |
|
6:30 AM |
Press SET, then select current day.
Set Day
Wed
MCR29472
1.Press the SET button, then press σ or τ to set the clock time.
2.Press the SET button, then press σ or τ to select the day of the week.
3.Press RUN to save & exit.
Note: If the display flashes Set Clock, the thermostat will follow your settings for the weekday “Wake” time period until you reset the time and day.
69-1760EFS—01 |
6 |
PRO TH4110D / TH4210D
System switch
The SYSTEM switch can be set to control your heating or cooling system, depending on the season.
• Cool: Cooling system control. • Off: All systems are off.
• Heat: Heating system control.
• Em Heat: Emergency & Auxiliary
Heat control. Compressor is locked out. (Select models only.)
M29473
Set SYSTEM switch to control the heating or cooling system.
CAUTION: EQUIPMENT DAMAGE HAZARD. Do not operate cooling system when outdoor temperature is below 50°F (10°C).
ENGLISH
7 |
69-1760EFS—01 |
Operating Manual
Fan switch
ENGLISH
Set the FAN switch to Auto or On.
In “Auto” mode (the most commonly used setting), the fan runs only when the heating or cooling system is on.
If set to “On,” the fan runs continuously.
M29473
Set FAN switch to choose whether the fan runs continuously or only as needed.
69-1760EFS—01 |
8 |
PRO TH4110D / TH4210D
Save money by setting program schedules
It’s easy to program your system for maximum energy savings. You can program four time periods each day, with different settings for weekdays and weekends.
|
|
|
WAKE |
Set to the time you awaken and the temperature you want |
|
|
|
||
|
|
|
6:00 am |
during the morning, until you leave for the day. |
|
|
|
70° |
|
|
|
|||
|
|
|
LEAVE |
Set to the time you leave home and the temperature you want |
|
|
|
||
|
|
|
8:00 am |
while you are away (usually an energy-saving level). |
|
|
|
62° |
|
|
|
|
||
|
|
|
RETURN
6:00 pm
70°
SLEEP
10:00 pm
62°
Set to the time you return home and the temperature you want during the evening, until bedtime.
Set to the time you go to bed and the temperature you want overnight (usually an energy-saving level).
ENGLISH
9 |
69-1760EFS—01 |
Operating Manual
ENGLISH
Energy Star® settings for maximum cost savings
This thermostat is pre-set to use Energy Star® program settings. We recommend these settings, since they can reduce your heating/cooling expenses by as much as 33%. (See next page to adjust times and temperatures of each time period.)
|
|
|
Heat (Mon-Fri) |
Cool (Mon-Fri) |
Heat (Sat-Sun) |
Cool (Sat-Sun) |
||
|
|
|
|
|
|
|
||
(6:00 am) |
|
|
70° |
75° |
70° |
75° |
||
Wake |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(8:00 am) |
|
|
|
° |
|
° |
62° |
83° |
Leave |
|
|
62 |
|
83 |
|
|
|
|
|
|
|
|
[Or cancel period] |
[Or cancel period] |
||
(6:00 pm) |
|
|
|
° |
|
° |
70° |
75° |
Return |
|
|
70 |
|
75 |
|
|
|
|
|
|
|
|
[Or cancel period] |
[Or cancel period] |
||
Sleep |
|
|
62° |
78° |
62° |
78° |
||
(10:00 pm) |
|
|
69-1760EFS—01 |
10 |
PRO TH4110D / TH4210D
To adjust program schedules
Press SET 3 times, then adjust time.
Set To
Set Schedule 75
6:30 AM
Heat
Wake MonTueWedThuFri
Press SET, then set desired temperature.
Set To Set Schedule 75
6:30 AM
Heat
Wake MonTueWedThuFri
MCR29474
1.Press SET until Set Schedule is displayed.
2.Press σ or τ to set your weekday Wake time (Mon-Fri), then press SET.
3.Press σ or τ to set the temperature for this time period, then press SET.
4.Set time and temperature for the next time period (Leave). Repeat steps 2 and 3 for each weekday time period.
5.Press SET to set weekend time periods (SatSun), then press RUN to save & exit.
Note: Make sure the thermostat is set to the system you want to program (Heat or Cool).
Note: To cancel an unwanted time period (except Wake), press and hold σ + HOLD for 4 seconds while in the Set Schedule mode.
ENGLISH
11 |
69-1760EFS—01 |
Operating Manual
ENGLISH
Program schedule override (temporary)
Press to temporarily adjust temperature.
Temporary |
Set To |
6:30 AM70
Press to resume program schedule.
Set To
6:30 AM75
Press σ or τ to immediately adjust the temperature. This will temporarily override the temperature setting for the current time period.
The new temperature will be maintained only until the next programmed time period begins (see page 9). For example, if you want to turn up the heat early in the morning, it will automatically be lowered later, when you leave for the day.
To cancel the temporary setting at any time, press RUN.
Note: Make sure the thermostat MCR29475 is set to the system you want to
control (heat or cool).
69-1760EFS—01 |
12 |
PRO TH4110D / TH4210D
Program schedule override (permanent)
Press to permanently adjust temperature.
Hold
Set To
6:30 AM70
Press to resume program schedule.
Set To
6:30 AM75
MCR29476
Note: Make sure the thermostat is set to the system you want to control (heat or cool).
Press HOLD to permanently adjust the temperature. This will override the temperature settings for all time periods.
The “Hold” feature turns off the program schedule and allows you to adjust the thermostat manually, as needed.
Whatever temperature you set will be maintained 24 hours a day, until you manually change it, or press RUN to cancel “Hold” and resume the program schedule.
ENGLISH
13 |
69-1760EFS—01 |
Operating Manual
ENGLISH
Adaptive Intelligent RecoveryTM (AIR)
Adaptive Intelligent Recovery eliminates guesswork when setting your schedule. It allows the thermostat to “learn” how long your furnace and air conditioner take to reach the temperature you want.
Just set your program schedule to the time you want the house to reach your desired temperature. The thermostat then turns on the heating or cooling at just the right time to reach your scheduled temperature at your scheduled time.
For example: Set the Wake time to 6 am and the temperature to 70°. The heat will come on before 6 am, so the temperature is 70° by the time you wake at 6.
69-1760EFS—01 |
14 |
PRO TH4110D / TH4210D
Built-in compressor protection
Inside |
Set To |
|
75 |
6:30 AM 75 |
|
Wake |
Cool |
|
On |
||
Wed |
||
|
MCR29477 |
Message flashes until safe restart time has elapsed.
This feature helps prevent damage to the compressor in your air conditioning or heat pump system.
Damage can occur if the compressor is restarted too soon after shutdown. This feature forces the compressor to wait for a few minutes before restarting.
During the wait time, the display will flash the message Cool On (or Heat On if you have a heat pump). When the safe wait time has elapsed, the message stops flashing and the compressor turns on.
ENGLISH
15 |
69-1760EFS—01 |
Operating Manual
Battery replacement
Pull at bottom to ENGLISH remove thermostat from wallplate.
Turn thermostat over, insert fresh AA alkaline batteries, then reinstall thermostat.
|
Batteries are optional (for backup |
|
power) if your thermostat was wired |
|
to run on AC power when installed. |
|
Install fresh batteries when the |
|
REPLACE BATT warning begins flash- |
|
ing. The warning flashes about two |
|
months before the batteries are |
|
depleted. |
|
Replace batteries once a year, or |
|
before leaving home for more than a |
|
month. If batteries are inserted within |
|
one minute, the time and day will not |
|
have to be reset. All other settings are |
|
permanently stored in memory, and |
MCR29478 |
do not require battery power. |
|
69-1760EFS—01 |
16 |
PRO TH4110D / TH4210D
In case of difficulty
If you have difficulty with your thermostat, please try the following suggestions. Most problems can be corrected quickly and easily.
Display is blank
Heating or cooling system does not respond
•Check circuit breaker and reset if necessary.
•Make sure power switch at heating & cooling system is on.
•Make sure furnace door is closed securely.
•Make sure fresh AA alkaline batteries are correctly installed (see page 16).
•Set system switch to Heat (see page 7). Make sure the temperature is set higher than the Inside temperature.
•Set system switch to Cool (see page 7). Make sure the temperature is set lower than the Inside temperature.
•Wait 5 minutes for the system to respond.
ENGLISH
17 |
69-1760EFS—01 |
Operating Manual
ENGLISH
In case of difficulty
Temperature settings do not change
“Cool On” or “Heat On” is flashing
Make sure heating and cooling temperatures are set to acceptable ranges:
•Heat: 40° to 90°F (4.5° to 32°C).
•Cool: 50° to 99°F (10° to 37°C).
•Compressor protection feature is engaged. Wait 5 minutes for the system to restart safely, without damage to the compressor (see page 15).
“Heat On” is not |
• |
Set the System switch to Heat, and set the temperature level above the |
displayed |
|
current room temperature (see page 7). |
“Cool On” is not |
• |
Set the System switch to Cool, and set the temperature level below the |
displayed |
|
current room temperature (see page 7). |
To restore |
Follow these steps to restore Energy Star default settings (see page 10): |
|
Energy Star® |
1. |
Press SET 3 times to display “Set Schedule.” |
default settings |
2. |
Press and hold SET and RUN at the same time for 4 seconds. |
|
||
|
3. |
Press RUN. |
69-1760EFS—01 |
18 |
PRO TH4110D / TH4210D
Customer assistance
Pull at bottom to remove thermostat from wallplate.
Turn thermostat over to find model number and date code.
For assistance with this product, please visit http://yourhome.honeywell.com.
Or call Honeywell Customer Care toll-free at
1-800-468-1502.
To save time, please note your model number and date code before calling.
Accessories/replacement parts
To order, please call Honeywell Customer Care toll-free at 1-800-468-1502.
Cover plate assembly*....Part No. 50002883-001
*Use to cover marks left by old thermostats.
MCR29479
ENGLISH
19 |
69-1760EFS—01 |
Operating Manual
ENGLISH
5-year limited warranty
Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and service, for a period of five (5) years from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Honeywell shall repair or replace it (at Honeywell’s option).
If the product is defective,
(i)return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it; or
(ii)call Honeywell Customer Care at 1-800-468-1502. Customer Care will make the determination whether the product should be returned to the following address:
Honeywell Return Goods, Dock 4 MN10-3860, 1885 Douglas Dr. N., Golden Valley, MN 55422, or whether a replacement product can be sent to you.
This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer.
69-1760EFS—01 |
20 |