Honeywell HHT-080, HHT-100 User Manual

4 (1)
IMPORTANT SAFETY
INSTRUCTIONS
READ AND SAVE THESE
SAFETY INSTRUCTIONS
BEFORE USING THIS AIR
PURIFIER
When using electrical appliances, basic
precautions should always be followed to
injury to persons, including the following:
1. Read all instructions before operating the air
purifier.
2. Place air purifier where it is not easily knocked
over by persons in the household.
3. Always turn the air purifier controls to the OFF
position and unplug from the wall outlet when
not in use.
4. To disconnect the model HHT-080 series air
purifiers, first turn the control to the OFF
position, grip the plug and pull it from the wall
outlet. To disconnect the model HHT-100 series
air purifiers, press the Power button to turn the
unit off, grip the plug and pull it from the wall
outlet. Never pull by the cord.
5. Do not use any product with a damaged cord
or plug or if product malfunctions, is dropped
or damaged in any manner. Keep the cord
away from heated surfaces.
6. Do not use air purifier outdoors.
7. Never use air purifier unless it is fully
assembled.
8. Do not run power cord under carpets, and do
not cover with throw rugs. Arrange cord such
that it will not be tripped over.
9. Do not use air cleaner where combustible
gases or vapors are present.
10. Do not expose the air purifier to rain, or use
near water, in a bathroom, laundry area or
other damp location.
11. The air purifier must be used in its upright
position.
12. Do not allow foreign objects to enter ventilation
or exhaust opening as this may cause electric
shock or damage to the air purifier. Do not
block air outlets or intakes.
13. Locate air purifier near the outlet and avoid
using an extension cord.
14. This appliance has a polarized plug (one blade
is wider than the other). To reduce the risk of
shock, this plug is intended to fit only one way
in a polarized outlet. If the plug does not fit
fully in the outlet, reverse the plug. If it still
does not fit, contact a qualified electrician.
DO NOT attempt to defeat this safety feature.
15. A loose fit between the AC outlet (receptacle)
and plug may cause overheating and a
distortion of the plug. Contact a qualified
electrician to replace loose or worn outlet.
16. Do not sit, stand or place heavy objects on the
air purifier.
17. Disconnect power supply before servicing.
WARNING: To Reduce The Risk of Fire or
Electric Shock, Do Not Use This Air Purifier
With Any Solid-State Speed Control Device.
PERMANENT
HEPA TOWER
AIR PURIFIERS
For Model Series
HHT-080 and HHT-100
YOUR AIR PURIFIER
HOW YOUR AIR PURIFIER WORKS
This model air purifier incorporates a 3-stage cleaning
system to help clean the air that passes through the filter
in the unit (Fig. 1).
Stage 1: Washable Particle Pre-Filter
Stage 2: 99% HEPA-Type Filter with antimicrobial treatment
Stage 3: Electronic Ionizer
Fig. 1
SET-UP
Select a firm, level and flat location. For proper airflow, locate the unit at least 3 feet (1 M) from any
wall or furniture.
When operating, large volumes of air are drawn toward the air purifier. Surrounding areas should be
cleaned and/or vacuumed frequently to prevent build-up of dust and other contaminates. This may also
help prolong the life of the filter. If the unit is placed on a light colored carpet, a small mat or rug should
be used underneath to prevent permanent staining. This is especially important in homes with
contamination from smoking or fireplaces.
Control Panel
HEPA-
Type
Filters
(2)
Pre-filter (1)
Rear
Grille
OPERATION
Model HHT-080 Series Operation:
Ensure the air purifier is plugged into a working
electrical outlet and the Power Knob is turned to the
OFF position.
Start and run the air purifier on High for several minutes
and then rotate the Power Knob to the desired cleaning
level (Fig. 3a).
Model HHT-100 Series Operation:
Ensure the air purifier is plugged into a working electrical
outlet.
Press the power button ( ) once. The unit will automatically start at medium power (Fig. 3b).
Press the power button again to select a different cleaning level.
It is recommended you run your air purifier 24 hours a day to ensure continuous cleaning.
Portable air purifiers are more effective in rooms where all doors and windows are closed.
Fig. 3a
Fig. 3b
IONIZER FEATURE
The Ionizer helps boost the performance of the air purifier
and helps freshen the air.
Press the Ionizer Control button ( ) (Fig. 4a & 4b).The
LED will illuminate. This will power the Ionizer on.
To turn the Ionizer feature off, simply press the button
again. The LED light will no longer be illuminated.
Fig. 4a
Fig. 4b
INSTALL HEPA-TYPE FILTERS
The HEPA-Type Filters are supplied within the air purifier. They are wrapped to ensure purity.
Turn-off and unplug the air purifier. While pressing on
the notches along the rear grille, pull the grille towards
you and remove it (See Fig. 2a & 2b). Gently push along
the edge of the filter frame and pull forward. Repeat for
the second filter.
Remove protective wrap from the filters.
Place back into the air purifier housing and snap filter
grille into place.
Fig. 2a Fig. 2b
HHT-080 Series HHT-100 Series
HHT-080 Series HHT-100 Series
ELECTRONIC FILTER CLEAN REMINDER
This model air purifier has an electronic filter check to remind you when to check and clean the HEPA-
Type filters based on the air cleaner’s hours of use.
When the HEPA-Type filters need to be cleaned, the light
will remain on until it is RESET. You may unplug the air
cleaner without interrupting the filter check.
A red LED light will illuminate when it is time to clean the
filter.
You should periodically check the filter. Depending on
operating conditions, the filters should be cleaned every 6
months to a year.
To RESET the Electronic Filter Check:
When the filter monitor light remains on, it is time to check/clean the HEPA-Type filters and reset the filter
monitor, if needed. With the unit powered on, insert the tip of a ball-point pen or paperclip next to the LED
filter check light and hold for approximately 5 seconds until the light turns off (Fig 5a & 5b). Depending
upon your individual usage (environment and hours used), you may need to check and clean the filters
more or less frequently. If the HEPA-Type filters are cleaned before the filter monitor light turns on, the
filter monitor should be reset at the same time.
These cleaning intervals are intended as guidelines only. Performance of any filter media is dependent
upon the concentration of contaminates going through the system. High concentrations of contaminates
such as dust, pet dander and smoking will reduce the useful performance of the filter.
NOTE: The HEPA-Type filters are not washable.
Fig. 5a Fig. 5b
OSCILLATION FEATURE (MODEL HHT-100 SERIES)
To help circulate fresher, cleaner air through the room, this unit has an oscillation
feature.
To turn Oscillation on, simply press the Oscillation button ( ) (Fig. 6).
To turn Oscillation Off, press the button again.
Will illuminate
when it is
time to clean
HEPA filters
Fig. 6
MAINTAINING YOUR STAGE 1 WASHABLE PARTICLE PRE-FILTERCLEANING THE HEPA-TYPE FILTERS
The Honeywell models HHT-080 Series and HHT-100 Series are equipped with
permanent HEPA-Type filters which never need replacement with normal use.
To Clean Your HEPA-Type Filter:
DO NOT USE WATER OR OTHER LIQUIDS TO CLEAN THE HEPA-TYPE FILTER.
To vacuum-clean the filter, hold the filter and run a vacuum cleaner with a nozzle
or brush attachment along the filter to pick-up the dirt and particles (Fig. 7).
Repeat along the entire surface of the HEPA-Type filter.
Note the filter may still be discolored even after cleaning it. This is acceptable
and will not affect performance.
After vacuuming the filter, place it back into the air purifier housing and snap filter grille into place.
If you have difficulty cleaning the filter, please visit us at www.kaz.com or call us at 1-800-332-1110.
Fig. 7
HHT-080 Series HHT-100 Series
ACCESSORIES AND REPLACEMENT FILTERS
To order replacement filters, visit our website at: www.kaz.com or call us at 1-800-332-1110.
Washable Pre-Filter (T.3024): $5.25
HEPA Filter (N.0101): $40.00 - Note that two (2) filters are required.
FREQUENTLY ASKED QUESTIONS
My Air Purifier is starting to make noise and the air output is less. What’s wrong?
The filters may be dirty. High amounts of contaminates can block the pores in the filter and stop the air
from moving through it. Clean the Filters.
How long should I run my Air Purifier?
For best results, you should operate your Air Purifier 24 hours a day.This unit will be more effective
when doors and windows are closed.
Can I wash my HEPA-Type filter?
No. Washing the HEPA-Type filter will destroy it.
We recommend that you clean the air purifier at least once a month and before extended storage. Use only
a dry cloth to wipe the external surfaces of the air purifier. DO NOT USE WATER, WAX POLISH, OR ANY
CHEMICAL SOLUTION.
If your Air Purifier will not be used for more than 30 days, we recommend:
• Remove the HEPA-Type Filters from the unit.
• Wrap the HEPA-Type Filters in an air tight plastic bag.
MAINTAINING YOUR STAGE 1 WASHABLE PARTICLE PRE-FILTER
The stage 1 particle pre-filter helps pick up large airborne particles that enter
the rear grille. This pre-filter can be periodically removed and shaken to clean
it. Alternatively, it can be rinsed by hand under warm water (Fig. 8). Let the
pre-filter air dry completely before inserting back into the unit. If you need to
replace this item, please see Consumer Relations section on the next page.
Fig. 8
MAINTAINING YOUR STAGE 1 WASHABLE PARTICLE PRE-FILTER
FREQUENTLY ASKED QUESTIONS
FREQUENTLY ASKED QUESTIONSCLEANING AND STORAGE
CONSUMER RELATIONS
Mail questions or comments to:
Kaz, Incorporated
Consumer Relations Dept.
250 Turnpike Road
Southborough, MA 01772
Call us toll-free at: 1-800-332-1110
E-mail: consumerrelations@kaz.com
Or visit our website at: www.kaz.com
Please be sure to specify a model number.
NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CONSUMER RELATIONS FIRST, RETURN
THE AIR PURIFIER TO THE ORIGINAL PLACE OF PURCHASE OR SEE YOUR WARRANTY. DO NOT
ATTEMPT TO OPEN THE MOTOR HOUSING YOURSELF, DOING SO MAY VOID YOUR WARRANTY AND
CAUSE DAMAGE TO THE AIR PURIFIER OR PERSONAL INJURY.
You should first read all instructions before
attempting to use this product.
A. This 5 year limited warranty applies to repair or
replacement of product found to be defective in
material or workmanship. This warranty does
not apply to damage resulting from
commercial, abusive, unreasonable use or
supplemental damage. Defects that are the
result of normal wear and tear will not be
considered manufacturing defects under this
warranty. KAZ IS NOT LIABLE FOR
INCIDENTAL OR CONSEQUENTIAL DAMAGES
OF ANY NATURE. ANY IMPLIED WARRANTY
OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE ON THIS PRODUCT IS
LIMITED IN DURATION TO THE DURATION OF
THIS WARRANTY. Some jurisdictions do not
allow the exclusion or limitation of incidental or
consequential damages or limitations on how
long an implied warranty lasts, so the above
limitations or exclusions may not apply to you.
This warranty gives you specific legal rights,
and you also may have other rights which vary
from jurisdiction to jurisdiction. This warranty
applies only to the original purchaser of this
product from the original date of purchase.
B. At its option, Kaz will repair or replace this
product if it is found to be defective in material
or workmanship. Defective product should be
returned to the place of purchase in
accordance with store policy. Thereafter, while
within the warranty period defective product
may be returned to Kaz.
C. This warranty does not cover damage resulting
from any unauthorized attempts to repair or
from any use not in accordance with the
instruction manual.
D. This warranty DOES NOT cover the washable
pre-filter or the HEPA filters, except for material
or workmanship defects.
E. Return defective product to Kaz, Incorporated
with a brief description of the problem. Include
proof of purchase and a $10 US/$15.50 CAN
check or money order for handling, return
packing and shipping charges. Please include
your name, address and a daytime phone
number.You must prepay shipping charges.
Send to:
In U.S.A.:
Kaz, Incorporated
Attn: Returns Department
4755 Southpoint Drive
Memphis, TN 38118
USA
In Canada:
Kaz, Incorporated
Attn: Returns Department
510 Bronte Street South
Milton, ON L9T 2X6
Canada
5 YEAR LIMITED WARRANTY
Loading...
+ 14 hidden pages