TrueZONE ARD, EARD, and ZD
Series Damper Assemblies
QUICK START GUIDE
Visit www.forwardthinking.honeywell.com to download installation instructions and learn more about Honeywell TrueZONE products.
1. Unpack the damper and install into ductwork.
NOTE: For insulated duct, slide the insulation under the actuator and tape it to the actuator’s outside flange to seal.
NOTE: In unconditioned spaces, mount the actuator only on the side or top of the damper. Mounting on the bottom of the damper may result in condensation dripping into the actuator.
2. Set the range stop to the desired position. Position 0 means fully closed.
NOTE: On ARD/ZD models, range stops prevent full closure. On EARD model, range stop prevents full open.
Table 1. Approximate ARD/ZD Bleed Rate.
Position |
Bleed Rate |
0 |
Closed |
|
|
1 |
16% |
|
|
2 |
30% |
|
|
3 |
50% |
|
|
3. Wire the actuator. See “Exemples de câblage typique” on page 4.
a. For 2 wire usage, wire M1 and M6. See Fig. 1. b. For 3 wire usage, break the plastic tab to
access M4. See Fig. 2.
c. For EARD wiring, use only 2 VENT terminals. See Fig. 3
33-00079EFS-03
TRUEZONE ARD, EARD, AND ZD SERIES DAMPER ASSEMBLIES
1.Remove the actuator.
2.Locate the two plastic grommets on the damper and move them from one side to other.
3.Rotate the damper to closed position.
4.Replace the actuator on the opposite side of the damper.
TrueZONE DAMPERS TO HZ432 ZONE PANEL
|
|
|
|
M1 |
COMMON |
|
||
|
|
|
|
|
|
|
|
|
M1 |
|
1ZONE DAMPER |
|
M6 CLOSED |
||||
M6 |
|
|
||||||
M4 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
R
M35493
Fig. 1. 2-Wire Operation (Red LED only).
TrueZONE DAMPERS TO HZ432 ZONE PANEL
|
|
M1 |
|
|
COMMON |
||
M1 |
1ZONE DAMPER |
M4 |
GREEN LED |
||||
M6 CLOSED |
|||||||
M6 |
|||||||
M4 |
|
|
|
|
|
|
R
M35494
Fig. 2. 3-Wire Operation (Red and Green LEDs).
NOTE: 2- and 3-wire operation are Power Close/Spring Open. Additional wire only adds green LED.
EIM |
|
|
|
TO THERMOSTAT |
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
CONV |
FURNACE |
||
|
|
|
|
|
|
|
|
|
|
|
|
|
POWER |
|
|
|
|
|
|
|
|
|
C |
||
|
|
|
|
|
|
|
|
|
||||
HEAT |
|
|
|
|
|
|
|
|
|
R |
||
|
|
|
|
|
|
|
|
|
||||
COOL |
|
|
|
|
|
|
|
|
|
W |
||
|
|
|
|
|
|
|
|
|
||||
FAN |
|
|
|
|
|
|
|
|
|
W2 |
||
|
|
|
|
|
|
|
|
|
||||
U1 |
|
|
|
|
|
|
|
|
|
|
Y |
|
|
|
|
|
|
|
|
|
|
|
|||
U2 |
|
|
|
|
|
|
|
|
|
|
Y2 |
|
|
|
|
|
|
|
|
|
|
|
|||
U3 |
|
|
|
|
|
|
|
|
A |
|
G |
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
|
VENT |
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
EARD
VENT
A
B
C
D
S4
S4 SENSORS
S3
S3
M35495
Fig. 3. Wiring an EARD to a VisionPRO® with RedLINK™.
33-00079EFS—03 |
2 |
Ensembles de registre TrueZONE séries ARD, EARD et ZD
GUIDE DE DÉMARRAGE RAPIDE
Visiter www.forwardthinking.honeywell.com pour télécharger les instructions d'installation et en apprendre plus sur les produits TrueZONE de Honeywell.
1.Déballer le registre et l'installer dans la tuyauterie.
REMARQUE : Sur les tuyaux isolés, faire glisser l'isolant sous l'actionneur et l'attacher sur la bride externe de l'actionneur pour assurer l'étanchéité.
REMARQUE : Dans les espaces non climatisés, monter l'actionneur uniquement sur le côté ou sur le haut du registre. Le montage en dessous du registre pourrait occasionner de la condensation qui s'écoulerait dans l'actionneur.
2.Régler la butée de plage à la position désirée. La position 0 indique que le registre est complètement fermé.
REMARQUE : Sur les modèles ARD/ZD, les butées de plage empêchent la fermeture complète. Sur le modèle EARD, la butée de plage empêche l'ouverture complète.
Tableau 1. Taux de purge approximatif pour les modèles ARD/ZD.
Position |
Taux de purge |
0 |
Fermé |
|
|
1 |
16 % |
|
|
2 |
30 % |
|
|
3 |
50 % |
|
|
3.Câbler l'actionneur. Voir « Exemples de câblage typique » sur la page 4.
a.Pour une utilisation à deux fils, câbler M1 et M6. Voir la Fig. 1.
b.Pour une utilisation avec trois fils, casser la languette en plastique pour accéder à M4. Voir la Fig. 2.
c.Pour le câblage du modèle EARD, utiliser seulement 2 bornes VENT. Voir la Fig. 3.