Remove your old thermostat

TURN OFF POWER at heating/cooling system (or fuse/circuit-breaker panel). Remove cover and thermostat, but leave wallplate with wires attached.

Leave wallplate in place

Is there a sealed tube containing mercury?

 

If so, see mercury notice below.

 

 

 

 

 

 

Old thermostat

Cover

MERCURY NOTICE: If your old thermostat contains mercury, contact your local waste management authority for proper disposal instructions.

® U.S. Registered Trademark. Patents pending. Copyright © 2006 Honeywell International Inc.

All rights reserved.

Pentax CT50, CT53, CT50K, CT53K Owner's Manual

CT50 Series

Label wires and remove old wallplate

Use a screwdriver to disconnect wires one by one. As you disconnect each wire, wrap it with the label matching the letter on your old thermostat. (Adhesive labels are supplied in your thermostat package.)

Remove the old wallplate only after all wires are labeled. Be careful not to let loose wires fall into the wall opening.

Wrap supplied labels securely around each wire

Do not let wires fall into wall opening!

IGNORE WIRE COLORS: Use only letter designations to identify wire types.

If your old thermostat has 3 or more wires, you may have purchased the wrong replacement thermostat. Stop now and call 1-800-468-1502 for advice.

Mark mounting position

1Pull wires through base.

2Level base if desired.

3Mark positions of both screw holes.

2

English: Page 1 • Français: Page 6 • Español: Página 11

Mount thermostat base

1 Drill holes at pencil-marked locations (3/16” holes for drywall, 7/32” holes for plaster).

2Use hammer to tap anchors into holes until flush with wall.

3Pull wires through thermostat base and insert screws. Check level if desired, then tighten screws.

Connect wires

1Match each labeled wire with same letter on terminal.

2Use a screwdriver to loosen screw terminals, insert bare wires beneath screws, then tighten screws.

3Push any excess wire back into the wall opening.

Labels don’t match?

If labels do not match letters on thermostat, see table below.

Existing wires

Connect to:

R RH 4 V

Terminal “R

 

 

W W1 H

Terminal “W

3

CT50 Series

Set heat anticipator (model CT50K only)

Move the adjustment arrow to the proper setting for your system (see table below).

Your system

Setting

Steam

1.2

 

 

Hot water heat

0.8

 

 

Warm air (high efficiency)

0.8

 

 

Warm air (standard)

0.4

 

 

Electric heat

0.3

 

 

Thermostat mounting

1 Align the slots on the cover with tabs on the sides of the base, then push gently until the cover snaps into place.

2 Restore power at the heating/cooling system, or at the fuse/circuit breaker panel.

Tab

4

English: Page 1 • Français: Page 6 • Español: Página 11

Operation

 

 

Temperature setting

System switch (select models)

Adjust to set desired indoor temperature.

Heat: Controls the heating system.

 

Off: All systems are off.

1-year limited warranty

Honeywell warrants this product to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the date of purchase by the consumer. If at any time during the warranty period the product is determined to be defective or malfunctions, Honeywell shall repair or replace it (at Honeywell's option).

If the product is defective,

(i)return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it; or

(ii)call Honeywell Customer Care at 1-800-468-1502. Customer Care will make the determination whether the product should be returned to the following address:

Honeywell Return Goods, Dock 4 MN10-3860, 1885 Douglas Dr.N., Golden Valley, MN 55422, or whether a replacement product can be sent to you.

This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer.

Honeywell's sole responsibility shall be to repair or replace the product within the terms stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE

OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you.

THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONEYEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.

This warranty gives you specific legal rights, and you may have other rights which vary from state to state.

If you have warranty questions, please write Honeywell Customer Relations, 1985 Douglas Dr, Golden Valley, MN 55422 or call 1-800-468-1502. In Canada, write Retail Products ON15-02H, Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V4Z9.

5

Loading...
+ 11 hidden pages