Hobart LG300 Installation Manual

OPERATIONAL MANUAL
INSTALLATION &
English & French
LG SERIES GAS FRYERS
MODELS:
LG300 ML-136528
LG400 ML-136622
LG500 ML-136643
For additional information on Vulcan-Hart or to locate an authorized parts and service provider in your area, visit our website at www.vulcanequipment.com
©VULCAN-HART 3600 NORTH POINT BLVD. DIVISION OF ITW FOOD EQUIPMENT GROUP, LLC BALTIMORE, MD 21222
WWW.VULCANEQUIPMENT.COM F-32910 REV. O (9-15)
VULCAN LG FRYERS
THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL GAS EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL.
POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE SMELL OF GAS IS DETECTED. THIS INFORMATION CAN BE OBTAINED FROM THE LOCAL GAS SUPPLIER.
IN THE EVENT A GAS ORDOR IS DETECTED, SHUT DOWN UNITS AT THE MAIN SHUTOFF VALVE AND CONTACT THE LOCAL GAS COMPANY OR GAS SUPPLIER FOR SERVICE.
IMPORTANT FOR YOUR SAFETY
IMPORTANT
FOR YOUR SAFETY
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.
LG Series Fryers F-32910 Rev. O (9-15)
-2-
VULCAN LG FRYERS
IMPORTANT FOR YOUR SAFETY……………………………………………. 2
INTRODUCTION……………………………………………………………….... 4
GENERAL……………………………………………………………....... 4
ORDERING PARTS…………………………………………………....... 4
FRYER CAPACITIES………………………………………………........ 4
UNPACKING…………………………………………………………....... 4
INSTALLATION…………………………………………………………….......... 5
Clearances………………………………………………….......... 5
Location ………………..……………………………….…........... 5
Flue Installation ……………………………………………......... 6
CODES AND STANDARDS………………………………………......... 6
ASSEMBLY …………..……………………………………………......... 7
FLUE EXHAST……………………………………………………........... 8
GAS CONNECTION…………………………………………………...... 8
Quick-Disconnect for Units on Casters……………………...... 9
GAS PRESSURE............................................................................... 9
TEST GAS SUPPLY…………………………………………………...... 9
FRYERS WITH CASTERS………………………................................ 9
LEVELING THE FRYER…………………………………......................10
OPERATION………………………………………………………………...........10
OVER-TEMPERATURE SHUTDOWN……………………………........11
BEFORE FIRST USE………………………………………………........ 11
Cleaning…………………………………………………….......... 11
FILLING TANK WITH SHORTENING…………………………........ 11
LIGHTING THE PILOT………………………………………..........…… 12
TURNING ON THE FRYER ……………………..........……………….. 13
TURNING OFF THE FRYER……………….........…………………….. 13
EXTENDED SHUTDOWN………………………......………………….. 14
BASIC FRYING INSTRUCTIONS…………….....…………………….. 14
Fry Basket Guidelines…………….....………………………….. 14
EXTENDED SHORTENING LIFE………….......……………………… 14
DRAINING THE TANK…………………….........………………………. 15
DAILY FILTERING-ALL MODELS………….........……………………. 15
CLEANING…………………………………………….........……………. 15
Daily…………………………………………………........………. 15
BOIL OUT PROCEDURE……………………………………….........……….... 16
MAINTENANCE…………………………………………………...........……….. 17
FLUE VENT INSPECTION………………………………….........…….. 17
Service in the US and Canada……………………….........…………... 17
In Australia…………………………………………….........……………. 17
TROUBLESHOOTING…………………………………........………………….. 17
Troubleshooting Chart……………………………......…………………. 17
WARRANY…………………………………………………......………………… 18
TABLE OF CONTENTS
LG Series Fryers F-32910 Rev. O (9-15)
-3-
VULCAN LG FRYERS
MODEL # of Heat Tubes BTU/hr. Width Inch (cm) Shortening lbs. (kg)
LG300 3 90,000 15.5 (39) 35-40 (16-18)
LG400 4 120,000 15.5 (39) 45-50 (21-23) LG500 5 150,000 21.0 (53) 65-70 (29-32)
FRYER CAPACITY
GENERAL
Vulcan Fryers are produced with quality workmanship and material. Proper installation, usage and maintenance will result in years of satisfactory performance.
Before installing the fryer, thoroughly read this manual and carefully follow all instruction. This manual is applicable to model listed on the cover page. Procedures in this manual will
apply to all models unless specified. Pictures and illustrations can be of any model unless the picture or illustration needs to be model specific.
To speed up your order, provide the model number, serial number, gas type, part needed, item part number (if known) and quantity needed.
This fryer was inspected before leaving the factory. The carrier assumes full responsibility for the safe delivery upon acceptance of the shipment. Check for possible shipping damage immediately after receipt.
If the fryer is found to be damaged, complete the following steps:
1. Carrier must be notified within 5 business days of receipt.
2. Carrier’s local terminal must be notified immediately upon discovery (note time, date, and who was spoken to), and follow up and confirm with written or electronic communication.
3. All original packing materials must be kept for inspection purposes.
4. The fryer cannot have been moved, installed, or modified.
5. Notify Vulcan Customer Service immediately at 800-814-2028. Check that the following have been included:
Crumb Rack Basket Hanger Adjustable Legs (4) Drain Pipe Extension Twin Fry Baskets (2) Manual and Warranty – Retain for future reference.
Do not use the door or its handle to lift the fryer.
INTRODUCTION
ORDERING PARTS
UNPACKING
LG Series Fryers F-32910 Rev. O (9-15)
-4-
VULCAN LG FRYERS
Before installing the fryer, verify that the type of gas (natural or propane) agrees with the specifications on the fryer data plate, which is located on the inside of the door panel. Make sure the fryer is configured for the proper elevation.
Record your fryer model, device, and serial numbers for future reference in the space provided below. This information can be found on the fryer data plate.
Fryer Model No: ___________________________ Device:___________________________________ Serial No: ________________________________ Clearances
Minimum clearance from combustible construction:
6” (15 cm) from the sides of the fryer
6” (15 cm) from the back of the fryer
The fryer may be installed on combustible floors Minimum clearance from noncombustible construction:
0” from the sides of the fryer
0” from the back of the fryer
Between the fryer and any open-top flame units:
16” (41 cm)
Allow space for servicing and operation.
Location
Install fryer in an area with sufficient air supply for gas combustion at fryer burners. Do not obstruct the flow of combustion and ventilation air. Provide adequate clearance for air openings into the combustion chamber.
Do not permit fans to blow directly onto fryer. Avoid wall-type fans, which create cross-currents within a room. Avoid
open windows next to sides or back. Electrical diagram located on inside of door.
INSTALLATION
LG Series Fryers F-32910 Rev. O (9-15)
-5-
VULCAN LG FRYERS
1. Unpack the flue box and flue wrap
2. Slide the flue box over the flue and secure it with the two self-tapping screws using a
5/16” socket
3. Slide the flue wrap over the flue
FLUE INSTALLATION: BEFORE USING FRYER INSTALL AND ASSEMBLE THE 10-5/8” FLUE TO THE FRYER..
LG Series Fryers F-32910 Rev. O (9-15)
-6-
VULCAN LG FRYERS
4. Secure it with four self-tapping screws two on the back and one on each side using a
5/16” socket
The fryer must be installed in accordance with:
In the United States:
State and local codes, or in the absence of local codes, with: National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). Copies may
be obtained from The American Gas Association Accredited Standards Committee Z223, @ 400 N. Capital St. NW, Washington, DC 20001 or the Secretary Standards Council, NFPA, 1 Batterymarch Park Quincy, MA 02169-7471.
NFPA Standard #96 Vapor Removal from Cooking Equipment, latest edition, available from the National Fire Protection Association, Batterymarch Park, Quincy, MA.
In the commonwealth of Massachusetts all gas appliances vented through a ventilation hood or exhaust system with a damper or with a power means of exhaust shall comply with 248 CMR.
In Canada:
Local codes CAN/CSA-B149.1 Natural Gas and Propane Code Installation (latest edition),
available from the Canadian Gas Association 350 Sparks Street, Ottawa, Ontario Canada K1R 7S8.
CSA C22.1 Canadian Electric Code L4W 5N6.
CODES AND STANDARDS
LG Series Fryers F-32910 Rev. O (9-15)
-7-
VULCAN LG FRYERS
The fryer must be restrained to prevent tipping and the splashing of hot liquid. The means of restraint may be the manner of installation, such as connection to a battery of appliances, installing the fryer in an alcove, or by separate means such as adequate ties.
Comply with Vapor Removal from Cooking Equipment, ANSI-NFPA Standard #96 (latest edition), available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
Locate the fryer under a hood with adequate connection to an exhaust duct. The hood must extend 6” (15 cm) beyond fryer on both sides.
Clearance above the fryer should be adequate for combustion byproducts to be removed efficiently.
An 18” (46 cm) minimum clearance should be maintained between the flue vent and the filters of the hood venting system.
Never make flue connections directly to the fryer. Do not obstruct the flow of the gases from the appliance. Proper air balance should
be maintained in the room.  Ensure that your ventilation system does not cause a down draft at the fryer’s flue
opening. Down draft will not allow the fryer to exhaust properly and will cause
overheating which may cause permanent damage. Damage caused by down draft
will not be covered under equipment warranty. Never allow anything to obstruct
the flue or ventilation exiting from the fryer flue. Do not put anything on top of flue
area.
All gas supply connections and any pipe joint compound must be resistant to the action of propane gases.
The gas inlet is located on the lower rear of the fryer. Codes require that a gas shutoff valve be installed in the gas line ahead of the fryer.
The gas supply line must be at least the equivalent of ½” (12.7 mm) iron pipe for single units and 1-1/4” (31.75 mm) for batteries. If using the optional quick-disconnect flex hose, ¾” (19 mm) iron pipe for single units.
ASSEMBLY
FLUE EXHAUST
GAS CONNECTION
LG Series Fryers F-32910 Rev. O (9-15)
-8-
VULCAN LG FRYERS
Make sure the pipes are clean and free of obstructions, dirt, and piping compound. A battery requires one or two connections of appropriate size for the gas requirement.
Prior to lighting, check all joints in the gas supply line for leaks. Use soap and water solution. Do not use an open flame.
After piping has been checked for leaks, fully purge gas pipes to remove air.
GAS PRESSURES (ALL MODELS):
The gas pressure should be set at 4” W.C. (Water Column) (0.8 kPa) for natural gas and 10 W.C. (2.75 kPa) for propane gas. If incoming pressure exceeds ½ PSI (3.45 kPa), an additional pressure regulator must be installed.
TESTING THE GAS SUPPLY PIPING SYSTEM:
When test pressures exceed ½ PSI (3.45 kPa), the fryer and its individual shutoff valve must be disconnected from the gas supply piping system.
When test pressures are ½ PSI (3.45 kPa) or less, the fryer must be isolated from the gas supply piping system by closing its individual shutoff valve.
Fryers with Casters: (Restraining device does not come supplied with fryer or casters).
Separate instructions for installing casters are included with the casters: The installation shall be made with a connector that complies with the
Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or Connectors for Moveable Gas Appliances, CAN/CGA-6.16, and a quick-disconnect device that complies with the Standard for Quick-Disconnect Devices for Use with Gas Fuel, ANSI z21.41 or Quick-Disconnect Devices for Use with Gas Fuel, CANI-6.9.
When installing a quick disconnect you must also install a means for limiting the movement of the fryer. This restraining device will prevent the gas line or quick disconnect from being strained. The restraining device should be attached to the cutout on the back panel. See illustration for location. If disconnection of the restraining device is necessary for service or cleaning, reconnect the restraining device after the fryer is placed back into its original position.
LG Series Fryers F-32910 Rev. O (9-15)
-9-
VULCAN LG FRYERS
The fryer must be installed with a connector (not supplied by Vulcan) complying with
the above codes.
The fryer must be installed with restraining means to guard against transmission of strain to the connector. See illustration.
The fryer must be installed with the casters provided. If the restraint is ever to be disconnected, first turn the gas supply off.
Check the level of the fryer by placing a level on top of the fryer after gas connections have been made.
Ensure that the fryer is level front-to-back and side-to-side in the final installed position. If using casters, lock the wheels after unit is level.
Hot oil and parts can cause burns. Use care when operating, cleaning and servicing the fryer.
Spilling hot frying compound can cause severe burns. Do not move fryer without draining all frying compound from the tank.
LEVELING THE FRYER
OPERATION
LG Series Fryers F-32910 Rev. O (9-15)
-10-
VULCAN LG FRYERS
If the shortening becomes overheated, a high-temperature shutoff device will turn the gas valve off and extinguish the pilot.
If the fryer shuts down due to overheating, DO NOT relight the pilot until the shortening temperature is below 300° F (149 C).
If an overheating situation persists, contact your local Vulcan-Hart authorized service office.
Cleaning
New units are wiped down at the factory to remove any visible signs of dirt, oil, grease, etc. remaining from the manufacturing process.
Before any food preparation, thoroughly wash the protective oil from all surface parts and the tank interior with hot soapy water to remove any film residue and dust or debris.
Do not use chlorine or sulfate/sulfide cleaners.
Wash any accessories shipped with unit. Rinse fryer and accessories thoroughly and drain the fryer. Wipe tank completely dry with a soft, clean cloth.
Solid shortening should NOT be used with LG300 or LG400 fryers. Melting solid shortening will damage the tank and void your warranty.
OVER-TEMPERATURE SHUTDOWN
BEFORE FIRST USE
FILLING TANK WITH SHORTENING
LG Series Fryers F-32910 Rev. O (9-15)
-11-
VULCAN LG FRYERS
Close the drain valve. Fill the fryer tank with liquid shortening. Shortening level should be between the min and max lines in the fryer tank. Shortening will expand when heated. Do not ill the fryer tank past the MAX line. Add fresh shortening as needed to maintain oil level.
LIGHTING THE PILOT
LG Series Fryers F-32910 Rev. O (9-15)