Hitachi С29-TF641S, С29-TF641SN, С29-TF641ST, С29-TF641SNT, С29-TF651S Service Manual

...
0 (0)

HITACHII I

 

 

HCPT

 

 

 

T1-003

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C29-TF641S/SN/ST/SNT

 

 

 

 

C29-TF651S/SN/ST/SNT

 

SERVICE MANUAL

 

 

C29-TF751S/SN/ST/SNT

 

 

 

 

 

 

 

 

 

 

T1 Chassis

CAUTION : Before servicing this chassis, it is important that the service techician reads the " Safety Precaution " and " Product Safety Notices " in this Service Manual.

CONTENTS

 

SAFETY PRECAUTIONS ...………………...…………….……………………………………………

2

PRODUCT SAFETY NOTICE …………...…………….………...……………...…………….………

2

REMOTE CONTROL UNIT ……………..………...…………….………………………………………

3

GENERAL OPERATIONS GUIDE .………………...…………….……………………………………

4

CIRCUIT DESCRIPTION …………...…………….……………………………………………………

5

ADJUSTMENT INSTRUCTIONS ……………………...…………….…………………………………

6

REPLACEMENT PARTS LIST …………………...…………….………………………………………

12

 

 

 

 

SPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE FOR IMPROVEMENT.

COLOR TELEVISION

 

 

MARCH 2005

Hitachi Consumer Products ( THAILAND ) , Ltd.

SAFTY PRECAUTIONS

WARNING: The following precautions should be opserved.

1.Do not install , remove, or handle the picture tube in any manner unless shatter proof goggles are worn. People not so equipped should be kept away while picture tubes are handled. Keep picture tube away from the body while handing.

2.

When

service is required, an isolation

transformer

 

should

be

inserted between

power

line and the

 

receiver before

any

service

is performed on the

 

chassis.

 

 

 

 

 

3.

When

replacing

the

chassis

in the cabinet,ensure

 

all

the protective devices are put back in place,such

 

as

barriers,

non - metallic knobs, adjustment or

compartment covers or shields, isolation resistors/ capacitors, etc.

4. When service is required, observe the original lead dressing. Extra precaution should be taken to

assure correct lead dressing in the high voltage circuitry area. Particularly note the R. G. B. lead dressing. Ensure they are dressed well away from the horizontal scan and F.B.T. circuitry.

5. Always use the manufacturer ' s replacement component. Always replace original spacers and maintain lead lengths. Especially critical components are indicated thus on the parts list and should not be replaced by other makes. Furthermore, where a short circuit has occurred, replace those components that indicate evidence of overheating.

6.Before returning a serviced receiver to the customer, the service technician must thoroughly test the unit to be certain that it is completely safe to operate without danger of electrical shock, and be sure that no protective device built into the instrucment by the manufacturer has became defective, or inadvertenly damaged during servicing. Therefore, the following checks are recommended for the continued protection of the customers and service techninians.

INSULATION

Insulation resistantce should not be less than 4.5 Mohm at 500 VDC between the mains poles and any accessible metal parts. Also, no flashover or breakdown should occur during the dielectric strength test, applying 3.2kV AC for two seconds between the main poles and accessible metal parts.

HIGH VOLTAGE

High voltage should always be kept at the rated value of the chassis and no higher. Operating at higher voltages may cause a failure of the picture tube or high voltage supply, and also, under certain circumstances could produce X-radiation moderately in excess of design levels. The high voltage must not, under any circumstances, exceed 34kV on the chassis.

X-RADIATION

TUBES : The primary source of X - radiation in this receiver is the picture tube. The tube utilized for the above mentioned function in this chassis is specially constructed to limit X - radiatuion.

For continued X-radiation protection, replace tube with the same type as the original, HITACHI approved type.

PRODUCT SAFETY NOTICE

Many electrical and mechanical parts in HITACHI television receiver have special safety related characteristics. These characteristics are often not evident from visual inspection, nor can be protection afforded by them necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified by marking with a on the schematics and replacement parts list in this Service Manual.The use of a substitute

replacement component which does not have the same safety characteristics as the HITACHI recommended replacement one, shown in the parts list in this Service Manual, may create electrical shock, fire, X - radiation,

or other hazards.

Product Safety is continuously under review and new instructions are issued from time to time. For the latest information,always consult the current HITACHI Service Manual. A subscription to ,or additional copies of HITACHI Service Manuals may be obtained at a nominal charge from your HITACHI sales offices.

TUBE DISCHARGE

The line output stage can develop voltages in excess of 25 kV; if the E.H.T cap is required to be removed, discharge the anode cap to chassis via a high value resistor, prior to its removal from the tube.

- 2 -

REMOTE CONTROL UNIT

2

 

2

 

1

5

1

5

19

17

19

17

16

18

16

18

 

14

 

14

 

4

 

4

 

 

20

9

 

8

8

 

 

10

9

10

 

6

12

6

12

3

3

7

7

15

15

11

13

11

13

 

Models without Teletext

 

Models with Teletext

 

 

 

 

1.

POWER ON/OFF SWITCH

11.

DEFAULT

2.

INPUT SELECTOR

12.

MUTE

3.

VOLUME UP/DOWN

13.

CHI/II (FOR NICAM/A2 MODELS)

4.

PROGRAMME UP/DOWN

14.

PROGRAMME SELECTOR (DIRECT KEY)

5.

RECALL

15.

CURSOR

6.

SURROUND SOUND

16.

RETURN

7.

MENU

17.

COLOR SYSTEM

8.

TIMER

18.

SOUND SYSTEM

9.

PICTURE

19.

EQUALIZER

10.

SOUND

20

T/TEXT FUNCTION KEY (T/TEXT MODELS ONLY)

- 3 -

GENERAL OPERATIONS GUIDE

With this set, all adjustments/settings are performed by selecting from menu screens. of adjustments/settings are shown below. To access the menu screen, press the MENU

Different menu screens and details button, then select the item by

pressing the up/down cursor buttons

and adjust by the left/right cursor buttons

.

- 4 -

BLOCK DIAGRAM

- 5 -

ADJUSTMENT INSTRUCTIONS

HOW TO GO TO SERVICE MODE

1.How to go to adjustment mode no 001 ~ 022 Procedure

(1)Turn TV off by power switch on the TV set.

(2)Press " FUNCTION " button on the TV set and kept depress the button.

(3)Turn TV on by power switch on the TV set.

2.How to go to adjustment mode no 101 ~ 328

Procedure

 

(1)

Set volume to be “0”.

(2)

Press

button on remote control to go to standby mode.

(3)

Press “TV/VIDEO” button on the TV set, and kept depress the button.

(4)

Press

button on remote control to go to operation mode.

(5)

TV will show service table,then please cancel to keep depress the "TV/VIDEO" button.

Note : 1. Press the UP/DOWN cursor buttons

to select adjustment mode no.

 

2. Adjust data by the left/right cursor buttons

.

 

 

 

3. Press "RECALL" buttons to restore the data.

 

 

 

 

+B ADJUSTMENT

 

 

 

 

 

PREPARATION

 

 

 

PROCEDURES

1

AC input voltage 230 + 5V(50Hz)

 

1

Adjust R954 to obtain +B voltage as below

2

Turns on the set and set the brightness and contrast

 

 

+B voltage : TP902

 

to Max.(Signal : Philips Pattern)

 

 

GND

: TP901

3

After 30 sec heat-run, check & adjust the +B voltage

 

 

 

 

 

 

 

 

 

 

FREE RUN FREQUENCY ADJUSTMENT

 

 

 

 

 

PREPARATION

 

 

 

PROCEDURES

1

Receive a PAL-I monoscope signal on TV mode.

 

1

Select adjustment mode no. 1 and press "MENU" button

 

 

 

 

one time.

 

 

 

 

 

 

 

VIF-VCO FREE RUN FREQUENCY ADJUSTMENT

 

 

 

 

 

PREPARATION

 

 

 

PROCEDURES

1

Receive a PAL-I monoscope signal on TV mode.

 

1

Select adjustment mode no. 2 and press "MENU" button

 

 

 

 

one time.

 

 

 

 

 

 

 

- 6 -

SOUND TRAP FREQUENCY ADJUSTMENT

 

PREPARATION

 

PROCEDURES

1

Receive a PAL-I monoscope signal on TV mode.

1

Select adjustment mode no. 3 and press "MENU" button

 

 

 

one time.

 

 

 

 

SECAM R-Y OFFSET ADJUSTMENT

 

PREPARATION

 

 

PROCEDURES

1

Receive a secam color bar signal on Video 2.

1

Select adjustment mode no. 4.

2

Connect oscilloscope probe to pin 5 of E701.

2

Adjust output level at pin 5 of E701 as indicated below

 

 

 

using service mode no. 4.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 + 0.1 V

SECAM B-Y OFFSET ADJUSTMENT

 

PREPARATION

 

PROCEDURES

1

Receive a secam color bar signal on Video 2.

1

Select adjustment mode no. 5.

2

Connect oscilloscope probe to pin 5 of E701.

2

Adjust output level at pin 5 of E701 as indicated below

 

 

 

using service mode no. 5.

0 + 0.1 V

WHITE PEAK LEVEL ADJUSTMENT

 

PREPARATION

 

 

 

 

 

 

PROCEDURES

1

Connect oscilloscope probe to pin 3 of E202 on CPT

1

Adjust output level at pin 3 of E202 as indicated below

 

P.W.B with respect to ground.

 

using service mode no. 15.

2

Input PAL cross hatch signal to Video 2 terminal.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cross hatch signal input level : 1 Vpp + 10%(with load

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75 ohm) or 2 Vpp + 10%(no load).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Set CONTRAST to MAX.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1H

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Set data in adjustment mode no.15 to 90.

 

A = 2.8 + 0.1Vpp

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- 7 -

VERTICAL SHIFT ADJUSTMENT

 

PREPARATION

 

 

PROCEDURES

1

Preheat more than 5 minutes of power supply.

1

Select the IIC control address No. 11.

2

Receive PAL Philips pattern signal.

2

Set the horizontal center line to vertical center maker

 

 

 

of CRT by adjustment of IIC.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vertical center marker of CRT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VERTICAL SIZE ADJUSTMENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PREPARATION

 

 

 

 

 

 

PROCEDURES

1

Preheat more than 5 minutes of power supply.

1

Select the IIC control address No. 12.

2

Receive Philips pattern signal.

2

Adjust IIC data to obtain the following conditions.

 

 

 

 

 

 

 

 

PAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 Check vertical amplitude as below by NTSC circle pattern.

NTSC

4 If picture isn't center, go back to IIC control No. 11 and adjust IIC data to obtain the following conditions.

- 8 -

SIDE PIN DISTORTION ADJUSTMENT

 

PREPARATION

 

PROCEDURES

1

Purity adjustment and convergence adjustment should

1

Receive the circle pattern signal.

 

be already completed.

2

Adjust the 1st outer vertical line (R/L) to pin, 2nd outer

2

Set Contrast = 100, Brightness = 50

 

vertical line (R/L) to straight using side pin adjustment

3

Set horizontal size adjustment to approximately 2-2 by

 

(PCC-AMP VR R557 / PCC-PHASE VR R564).

 

H-WIDTH VR R559.

3

Receive the cross hatch signal.

4

Vertical amplitude adjustment should be already

4

Check that the vertical line is straight, except 1st outer

 

completed.

 

vertical line (R/L).

 

 

 

*Pin distortion spec. DL 3mm ,DR 2mm*

 

 

 

 

HORIZONTAL CENTER ADJUSTMENT

 

PREPARATION

 

PROCEDURES

1

Side pin adjustment should be already completed.

1

Adjust adjustment mode no. 13 so that the average

2

Receive circle pattern signal.

 

reading of R and L is 2.0 + 0.5 at circle pattern signal.

 

 

 

 

HORIZONTAL SIZE ADJUSTMENT

 

PREPARATION

PROCEDURES

1

Horizontal center adjustment should be already

1 Adjust Horizontal size (H-WIDTH VR R559) so that the

 

completed.

average reading of right and left is 2.0 + 0.5.

2Receive circle pattern signal.

3Set Contrast = 100, Brightness = 50

2.0 + 0.5

2.0 + 0.5

- 9 -

FOCUS ADJUSTMENT

 

 

 

PREPARATION

 

 

 

 

 

 

 

PROCEDURES

1

Receive Philips pattern signal.

 

 

 

 

1

Set picture to mode 1

2

Vertical amplitude adjustment should be already

 

 

2

Turn the focus VR gradually clockwise from the full

 

completed.

 

 

 

 

 

 

 

 

counterclockwise and adjust so that the halo of vertical

3

Adjust the cut-off after pre-adjust focus VR.

 

 

 

center line does not appear, and horizontal line is

4

Check the cut-off in case focus is re-adjusted

 

 

 

MIN. width.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HORIZONTAL

 

 

 

 

1 2 3 4 5 6 7

 

NO.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ZOOM

 

 

 

HALO

 

 

 

 

 

 

 

 

 

 

 

VERTICAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHITE BALANCE ADJUSTMENT

 

 

 

 

 

 

 

 

 

 

 

PREPARATION

 

 

 

 

 

 

 

PROCEDURES

1

Adjust the W/B after the Power is turned ON for 20 minute

 

1

Turn the screen adjusting VR clockwise and set it to the

2

Purity adjustment should be completed.

 

 

 

 

 

position where the bright line starts appearing on CPT

3

Set the vertical incident illumination on the CPT surface

 

 

screen.

 

 

to 20 lux or less.

 

 

 

 

2

Take the first appeared color as the reference. Adjust the

4

Receive white raster signal.

 

 

 

 

 

other colors by remote until both appear to be the same

5

Set adjustment mode data as table on the next page

 

 

 

level as the reference. (A white horizontal line is seen at

 

to default.

 

 

 

 

 

 

 

 

the CPT center.)

 

 

Disp No

 

ITEM

 

Default

 

 

 

 

Low brightness adjustment data

 

 

016

R-CUTOFF

 

127

 

 

 

Red

………. ”1” key for up, “4” key for down.

 

 

017

G-CUTOFF

 

127

 

 

 

Green

………. ”2” key for up, “5” key for down.

 

 

018

B-CUTOFF

 

127

 

 

 

Blue

………. ”3” key for up, “6” key for down

 

 

019

R-DRIVE

 

63

 

 

 

Don’t change the data of the reference color

 

 

020

B-DRIVE

 

63

 

 

3

Exit the lateral line mode. (Press “MUTE” by remote).

 

 

021

SUB-BRIGHT

 

127

 

 

4

Set white balance meter at the center of the screen.

6

Turn the screen adjustment VR fully counterclockwise.

 

5

Adjust brightness control so that the indication of the

7

Set to lateral line mode by Press “MUTE”

button on

 

 

 

brightness meter is a prescribed value of brightness

 

remote control .

 

 

 

 

 

adjustment. Adjust white balance with the white balance

 

 

 

 

 

 

 

 

 

 

 

control data (Red/Blue).

 

 

 

 

 

 

 

 

 

 

 

 

High brightness adjustment data

 

 

 

 

 

 

 

 

 

 

 

Red

………. ”7” key for up, “0” key for down.

 

 

 

 

 

 

 

 

 

 

 

Blue

………. ”8” key for up, “9” key for down.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- 10 -

SUB-BRIGHTNESS ADJUSTMENT

 

 

PREPARATION

 

 

 

 

 

 

 

 

 

 

 

PROCEDURES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Turn the TV set on and heat run for 20 minutes or more.

 

1

Press "PICTURE" key until go to picture mode 2.

 

 

2

Horizontal size adjustment and side pin adjustment

 

2

The sub-brightness should be adjusted (Adjustment

 

should be completed.

 

 

 

 

mode no. 21) using11 steps gray scale (A1-A1)

of color

3

Receive Philips pattern signal.

 

 

bar pattern

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set picture mode 2 as shown below.

 

3

Adjust until A10 is complete black and A9 is lightly black.

 

 

 

 

 

 

 

4

Go out from service mode.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTRAST

:

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COLOR

:

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BRIGHTNESS

:

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

A

 

A

 

A

 

 

A

A

 

A

 

A

A

 

A

A

 

 

 

 

 

 

 

 

 

 

11

 

10

9

 

 

8

 

7

 

 

6

 

5

 

4

3

 

 

2

 

 

1

 

 

 

 

 

 

 

 

5

Adjust

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

picture mode 2 as below.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTRAST

:

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COLOR

 

 

 

 

:

 

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BRIGHTNESS

:

 

50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Press "PICTURE" key until go to picture mode 1.

 

 

AGC ADJUSTMENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PREPARATION

 

 

 

 

 

 

 

 

 

 

 

PROCEDURES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

All adjustment except for AGC adjustment should be

 

1

Select adjustment mode no. 14 (TUNER AGC) and press

 

completed. Heat-run for more than 5 min.

 

 

“MENU” key one time. Data will be adjusted automatically

2

Receive signal as table on the next page.

 

2

.When AGC adjustment is complete,screen should be

3

Set Contrast = 100, Brightness = 50.

 

 

shown "OK" on the right-top side.

 

It the screen show

4

Set the Sound System and Color System depending on

 

 

"NG" ,it means AGC adjustment is abnormal.

 

 

 

the broadcast system.

 

 

 

 

 

NO.

 

 

 

 

 

 

 

ADJUSTMENT

 

 

 

 

10

 

 

 

 

 

 

 

 

5

Set the antenna input level as specified below.

 

 

 

014

 

 

 

 

 

 

 

 

 

43

 

 

 

 

 

 

 

 

 

 

 

 

OK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

"OK"

 

 

MODEL

 

T1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DESTINATION

 

ALL

 

 

 

 

NO.

 

 

 

 

 

 

 

ADJUSTMENT

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

SYSTEM

 

BG

 

 

 

 

014

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

 

 

 

 

NG

 

 

 

 

 

 

 

 

CHANNEL

 

CH10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

"NG"

 

 

INPUT SIGNAL

 

Philips Pattern

 

 

 

Caution : After AGC adjustment

is complete, data in

 

 

INPUT LEVEL

 

- 54 dBm / 55dBµ(75Ω)

 

 

 

adjustmentment mode no. 14 should be more than 30.

 

 

 

 

 

 

 

 

If not, please re-check or/and adjust again.

 

 

 

 

 

 

 

 

 

 

- 11 -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hitachi С29-TF641S, С29-TF641SN, С29-TF641ST, С29-TF641SNT, С29-TF651S Service Manual

REPLACEMENT PARTS LIST

PRODUCT SAFETY NOTE : Components marked with a have special characteristics important to safety. Before replacing any of these components, read carefully the PRODUCT SAFETY NOTICE of this Service Manual. Don't degrade the safety of the receiver through improper servicing

NO

CCT NO.

HITACHI

HITACHI

 

REMARK

PARTS NO.

DESCRIPTION

SN ST SNT S

 

#I904

 

1

THS0401001P

HEAT SINK I904 / I905

 

 

2

#I501

THS0402001P

HEAT SINK I501

 

 

3

#Q502

THS0403001P

HEAT SINK Q502

 

 

4

#I901

THS0404002P

HEAT SINK I901 ( L = 60mm )

 

 

5

#Q503

THS0405001P

HEAT SINK Q503 ( L = 40mm )

 

 

6

#D902

THS0405002P

HEAT SINK D902 ( L = 25mm )

 

 

7

C101

0800358R

CAP ELEC 1000UF 6.3V M

 

 

8

C102

CE-1TZ103

CAP CER 0.01UF 50V Z

 

 

9

C103

0800294R

CAP ELEC 10UF 50V M

 

 

10

C107

0800303R

CAP ELEC 22UF 50V M

 

 

11

C108

0890092R

CAP CER 2200PF 50V M

 

 

12

C201

0800352R

CAP ELEC 470UF 10V M

 

 

13

C202

CE-1TZ104

CAP CER 0.1UF 50V Z

 

 

14

C203

CE-1TZ104

CAP CER 0.1UF 50V Z

 

 

15

C206

CE-1TZ103

CAP CER 0.01UF 50V Z

 

 

16

C207

CE-1TCHJ181

CAP CER 180PF 50V J CH

 

 

17

C208

CE-1TZ103

CAP CER 0.01UF 50V Z

 

 

18

C209

0800352R

CAP ELEC 470UF 10V M

 

 

19

C210

0800279R

CAP ELEC 1UF 50V M

 

 

20

C211

CE-1TZ103

CAP CER 0.01UF 50V Z

 

 

21

C212

0800279R

CAP ELEC 1UF 50V M

 

 

22

C213

0800279R

CAP ELEC 1UF 50V M

 

 

23

C214

0880183R

CAP POLYESTER 0.015UF 50V J

 

 

24

C215

CE-1TCHJ221

CAP CER 220PF 50V J CH

 

 

25

C216

CE-1TZ104

CAP CER 0.1UF 50V Z

 

 

26

C217

0800352R

CAP ELEC 470UF 10V M

 

 

27

C218

0800317R

CAP ELEC 47UF 16V M

 

 

28

C219

EL-B10V471R

CAP ELEC 470UF 10V M 105 C

 

 

29

C220

0800362F

CAP ELEC 1000UF 25V M

 

 

30

C221

0890092R

CAP CER 2200PF 50V M

 

 

31

C222

0800279R

CAP ELEC 1UF 50V M

 

 

32

C223

0890065R

CAP CER 22PF 50V J SL

 

 

33

C224

0800277R

CAP ELEC 0.47UF 50V M

 

 

34

C225

0880198R

CAP POLYESTER 0.22UF 50V J

 

 

35

C226

0880198R

CAP POLYESTER 0.22UF 50V J

 

 

36

C227

CE-1TZ104

CAP CER 0.1UF 50V Z

 

 

 

 

 

- 12 -

 

 

Loading...