Hitachi RAC24CH2, RAS18CH1, RAS24CH2 User Manual

0 (0)
SPLIT TYPE AIR CONDITIONER
INDOOR UNIT/OUTDOOR UNIT
MODEL RAS18CH1 / RAC18CH1 RAS24CH2 / RAC24CH2
OUTDOOR UNIT INDOOR UNIT
ENGLISH
Instruction manual Page 1~26
To obtain the best performance and ensure years of trouble free use, please read this instruction manual completely.
Bedlenungsanleitung Suite 27~52
Bitte lesen Sie diese Bedienungsanleitung aufmerksam durch, um durch richtige Bedienung jahrelangen und störungsfreien Betrieb zu gewährleisten.
Mode d’emploi Page 53~78
Des performances optimales et un fonctionnement à long terme seront assurés en appliquant les présentes instructions après avoir entièrement lu ce mode d’emploi.
Manuale di istruzioni Pag. 79~104
Per garantire la migliore prestazione e la più lunga durataleggere attentamente e al completo le seguanti istruzioni.
RAS-18CH1 RAS-24CH2
Manual de instrucciones gina 105~130
Para obtener el mejor funcionamiento y asegurar años de uso libre de problemas, lea cuidadosamente este manual de instrucciones.
Manual de instruções Página 131~156
A fim de obter um bom funcionamento e de garantir uma utilização sem falhas durante muitos anos, é favor ler este manual de instruções completamente.
O‰ЛБ›В˜ XВИЪИЫМФ‡ ™ÂÏ›‰· 157~182 °И· ЩЛУ О·П‡ЩВЪЛ ‰˘У·Щ‹ ·fi‰ФЫЛ О·И ЩЛУ М·ОЪФ¯ЪfiУИ· О·И ¯ˆЪ›˜ ЪФ‚П‹М·Щ· ¯Ъ‹ЫЛ ЩЛ˜ Ы˘ЫОВ˘‹˜ ·˘Щ‹˜, ·Ъ·О·ПФ‡МВ ‰И·‚¿ЫЩВ П‹Ъˆ˜ ЩИ˜ Ф‰ЛБ›В˜ ¯ВИЪИЫМФ‡ ЩЛ˜.
Инструкция по эксплуатации
Для обеспечения наилууших эксплуатационных характеристик и многолетней безотказной работы оборудования необходимо полностыо оэнакомиться с данной Инструкцией по эксплуатации.
– 1 –
стр. 183~208
SAFETY PRECAUTION
Please read the Safety Precaution carefully before operating the unit to ensure correct usage of the unit.
Pay special attention to signs of Warning and Caution. The “Warning” section contains matters which, if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may result in serious consequences if not observed properly. Please observe all instructions strictly to ensure safety.
The sign indicate the following meanings.
!
!
Make sure to connect earth line.
Indicates the instructions that must be followed.
Please keep this manual after reading.
PRECAUTIONS DURING INSTALLATION
Do not reconstruct the unit. Water leakage, fault, short circuit or fire may occur if you reconstruct the unit by yourself.
!
WARNING
!
CAUTION
Please ask your sales agent or qualified technician for the installation of your unit. Water leakage, short circuit or fire may occur if you install the unit by yourself.
Please use earth line. Do not place the earth line near water or gas pipes, lightning-conductor, or the earth line of telephone. Improper installation of earth line may cause electric shock.
A circuit breaker should be installed depending on the mounting site of the unit. Without a circuit breaker, the danger of electric shock exists.
Do not install near location where there is flammable gas. The outdoor unit may catch fire if flammable gas leaks around it.
Please ensure smooth flow of water when installing the drain hose.
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
!
W
A R N
I N G
Should abnormal situation arises (like burning smell), please stop operating the unit and turn off the circuit breaker. Contact your agent. Fault, short circuit or fire may occur if you continue to operate the unit under abnormal situation.
Please contact your agent for maintenance. Improper self maintenance may cause electric shock and fire.
Please contact your agent if you need to remove and reinstall the unit. Electric shock or fire may occur if you remove and reinstall the unit yourself improperly.
The sign in the figure indicates prohibition.
W
A R N
N
G
PRECAUTIONS DURING OPERATION
Avoid an extended period of direct air flow for your health.
!
Do not put objects like thin rods into the panel of blower and suction side because the high-speed fan inside may cause danger.
I
Do not use any conductor as fuse wire, this could cause fatal accident.
During thunder storm, disconnect and turn off the circuit breaker.
– 2 –
PRECAUTIONS DURING OPERATION
The product shall be operated under the manufacturer specification and not for any other intended use.
Do not attempt to operate the unit with wet hands, this could cause fatal
ENGLISH
accident.
When operating the unit with burning equipments, regularly ventilate the room to avoid oxygen insufficiency.
Do not direct the cool air coming out from the air-conditioner panel to face household heating apparatus as this may affect the working of apparatus such as the electric kettle, oven etc.
Please ensure that outdoor mounting frame is always stable, firm and without defect. If not, the outdoor unit may collapse and cause danger.
Do not splash or direct water to the body of the unit when cleaning it as this may cause short circuit.
!
C A
Do not use any aerosol or hair sprays near the indoor unit. This chemical can adhere on heat exchanger fin and blocked the evaporation water flow to drain pan. The water will drop on tangential fan and cause water splashing out from indoor unit.
U T
I
O
Please switch off the unit and turn off the circuit breaker during cleaning, the high-speed fan inside the unit may cause danger.
N
Turn off the circuit breaker if the unit is not to be operated for a long period.
Do not climb on the outdoor unit or put objects on it.
Do not put water container (like vase) on the indoor unit to avoid water dripping into the unit. Dripping water will damage the insulator inside the unit and causes short-circuit.
Do not place plants directly under the air flow as it is bad for the plants.
When operating the unit with the door and windows opened, (the room humidity is always above 80%) and with the air deflector facing down or moving automatically for a long period of time, water will condense on the air deflector and drips down occasionally. This will wet your furniture. Therefore, do not operate under such condition for a long time.
If the amount of heat in the room is above the cooling or heating capability of the unit (for example: more people entering the room, using heating equipments and etc.), the preset room temperature cannot be achieved.
– 3 –
NAMES AND FUNCTIONS OF EACH PART
INDOOR UNIT
Air filter
To prevent dust from coming into the indoor unit. (Refer page 21)
Front panel
Indoor unit indicators
Light indicator showing the operating condition. (Refer page 5)
OUTDOOR UNIT
Horizontal deflector (Air Outlet)
(Refer page 16)
Remote controller
Send out operation signal to the indoor unit. So as to operate the whole unit. (Refer page 6)
Drain pipe
Condensed water drain to outside.
Connecting cord and insulation pipe for piping
Air inlet (Back and Left side)
Air outlet
Vertical deflector
MODEL NAME AND DIMENSIONS
MODEL RAS-18CH1 / RAS-24CH2 RAC-18CH1 / RAC-24CH2
WIDTH (mm)
1030
850
– 4 –
!
CAUTION
When heating operation, drain or defrosted water flows out from outdoor unit. Dont close drain outlet portion
in chilly area so as not to freeze these.
HEIGHT (mm)
295 650
DEPTH (mm)
183 298
INDOOR UNIT INDICATORS
HITACHI
OPERATION INDICATOR
OPERATION LAMP
This lamp lights during operation. The OPERATION LAMP flashes in the following cases during heating.
(1) During preheating
For about 2–3 minutes after starting up.
(2) During defrosting
Defrosting will be performed about once an hour when frost forms on the heat exchanger of the outdoor unit, for 5–10 minutes each time.
TIMER LAMP
This lamp lights when the timer is working.
FILTER LAMP
When the device is operated for a total of about 100 hours, the FILTER lamp lights to indicate that it is time to clean the filter. The lamp goes out when the POWER SWITCH set to OFF and ON again.
This figure shows the opening condition of
front panel. Refer to page 20 in relation to how to open or close the front panel.
ENGLISH
AUTO RESTART SWITCH
AUTO
RESTART
SWITCH
AUTO RESTART SWITCH
In the event of power failure, the air conditioner will restart automatically in the previously selected mode once
the power is restored.
In the event of power failure during TIMER operation, the timer will be reset and the unit will begin or stop
operating under a new timer setting.
– 5 –
NAMES AND FUNCTIONS OF REMOTE CONTROL UNIT
REMOTE CONTROLLER
This controls the operation of the indoor unit. The range of control is about 7 meters. If indoor lighting is controlled electronically, the range of control may be shorter. This unit can be fixed on a wall using the fixture provided. Before fixing it, make sure the indoor unit can be controlled from the remote controller.
Signal emitting window/transmission sign
Point this window toward the indoor unit when controlling it.
CH
˚
CH
˚
RESET
AUTO HEAT DEHUMIDIFY COOL FAN
FAN SPEED LOW MED HI
SLEEPING STOP (CANCEL) START (RESERVE) START/STOP TIME TIMER SET
TIMER SELECTOR ON TIMER OFF TIMER
AUTO SWING
The transmission sign blinks when a signal is sent.
Display
This indicates the room temperature selected, current time, timer status, function and intensity of circulation selected.
START/STOP button
Press this button to start operation. Press it again to stop operation.
SLEEP button
Use this button to set the sleep timer.
TEMPERATURE buttons
Use these buttons to raise or lower the temperature setting. (Keep pressed, and the value will change more quickly.)
TIME button
Use this button to set and check the time and date.
RESET buttons
FUNCTION selector
Use this button to select the operating mode. Every time you press it, the mode will change from (AUTO) to (HEAT) to (DEHUMIDIFY) to
(COOL) and to (FAN) cyclically.
FAN SPEED selector
This determines the fan speed. Every time you press this button, the intensity of circulation will change from (AUTO) to (HI) to (MED) to (LOW) (during the (FAN) mode, from HI to MED to LOW).
AUTO SWING button
Controls the angle of the horizontal air deflector.
TIMER control
Use this button to set the timer.
OFF-TIMER button Select the turn OFF time.
ON-TIMER button Select the turn ON time.
RESERVE button Time setting reservation.
CANCEL button Cancel time reservation.
Precautions for Use
Do not put the remote controller in the following places.
Under direct sunlight.
In the vicinity of a heater.
Handle the remote controller carefully. Do not drop it on the floor,
and protect it from water.
Once the outdoor unit stops, it will not restart for about 3 minutes
(unless you turn the power switch off and on or unplug the power cord and plug it in again).
This is to protect the device and does not indicate a failure.
If you press the FUNCTION selector button during operation, the
device may stop for about 3 minutes for protection.
– 6 –
AUTOMATIC OPERATION
The device will automatically determine the mode of operation, HEAT, COOL or DEHUMIDIFY depending on the initial room temperature. The selected mode of operation will not change when the room temperature varies.
Press the FUNCTION selector so that the display indicates the (AUTO) mode of operation.
ENGLISH
RESET
1
START
STOP
When AUTO has been selected, the device will automatically determine
the mode of operation, HEAT, COOL or DEHUMIDIFY depending on the initial room temperature.
Press the (START/STOP) button. Operation starts with a beep. Press the button again to stop operation.
As the settings are stored in memory in the remote controller, you only have
to press the (START/STOP) button next time.
You can raise or lower the temperature setting as necessary by maximum of 3°C.
°C
The preset temperature and the actual room temperature may vary
somewhat depending on conditions.
The display does not indicate the preset temperature in the AUTO mode.
If you change the setting, the indoor unit will produce a beep.
Press the temperature button and the temperature setting will change by 1°C each time.
Condition of Automatic Operation
Initial room temperature (approx.)
-
Over 27°C COOL
-
23~27°C
DEHUMIDIFY
-
Under 23°C HEAT
Temperature settingFunction
27°C
Slightly lower than the room temperature
23°C
– 7 –
FAN SPEED
HI at start, MED or LOW after the preset temperature is reached
LOW
HI at start, MED or LOW after the preset temperature is reached
HEATING OPERATION
Use the device for heating when the outdoor temperature is under 21°C.
When it is too warm (over 21°C), the heating function may not work in order to protect the device.
Press the FUNCTION selector so that the display indicates (HEAT).
1
Set the desired FAN SPEED with the (FAN SPEED) button (the display indicates the setting).
(AUTO): The fan speed is HI at first and varies to MED
automatically when the preset temperature has
2
(HI) : Economical as the room will become warm
(MED) : Quiet. (LOW) : More quiet.
Set the desired room temperature with the TEMPERATURE buttons (the display indicates the setting).
been reached.
quickly. But you may feel a chill at the beginning.
RESET
C
˚
3
C
˚
The temperature setting and the actual room temperature may vary somewhat depending on conditions.
START
STOP
Press the (START/STOP) button. Heating operation starts with a beep. Press the button again to stop operation.
As the settings are stored in memory in the remote controller, you only
have to press the (START/STOP) button next time.
The range of 18-22°C is recommended as the room temperature for heating. If the temperature setting is 20°C, the room temperature will be controlled at around 20°C.
– 8 –
DEHUMIDIFYING OPERATION
Use the device for dehumidifying when the room temperature is over 16°C. When it is under 15°C, the dehumidifying function will not work.
Press the FUNCTION selector so that the display indicates
(DEHUMIDIFY). The FAN SPEED is set at LOW automatically. The FAN SPEED button does not work.
Set the desired room temperature with the TEMPERATURE button (the display indicates the setting).
The range of 20-26˚C is recommended as the room temperature for dehumidifying.
RESET
C
˚
1
2
ENGLISH
C
˚
Dehumidifying Function
START
STOP
As the settings are stored in memory in the remote controller, you
Press the (START/STOP) button. Dehumidifying operation starts with a beep. Press the button again to stop operation.
only have to press the
(START/STOP) button next time.
When the room temperature is higher than the temperature setting: The device will dehumidify the room, reducing the room temperature to the preset level. When the room temperature is lower than the temperature setting: Dehumidifying will be performed at the temperature setting slightly lower than the current room temperature, regardless of the temperature setting. The function will stop (the indoor unit will stop emitting air) as soon as the room temperature becomes lower than the setting temperature.