HEUFT GATEWAY II Operating Instructions Manual

Operating Instructions
HEUFT GATEWAY
II
HBDR20010 ENG 20.00 Bedienungsanleitung GATEWAY II
*HBDR20010ENG*
HEUFT contact addresses
HEUFT
SYSTEMTECHNIK GMBH
Burgbrohl, GERMANY Phone: +49 2636 56 0
info@heuft.com
HEUFT SCAN Aps
Gilleleje, DENMARK
Phone: +45 4836 5070
scandinavia@heuft.com
HEUFT ASIA LTD.
Hong Kong, CHINA
Phone: +63 28462607
asia@heuft.com
HEUFT LTD.
Ta mw o rt h ,
GREAT BRITAIN
Phone: +44 1 827 255800
uk@heuft.com
HEUFT USA Inc.
Downers Grove, USA
Phone: +1 630 968 9011
usa@heuft.com
HEUFT AUSTRIA
Leobersdorf, AUSTRIA
Phone: +43 2256 65556 0
austria@heuft.com
HEUFT HISPANIA, S.A.
Madrid, SPAIN
Phone: +34 91 6667 300
spain@heuft.com
HEUFT DO BRASIL Ltda.
Alphaville-S.P., BRASIL
Phone: +55 11 4195 7671
brasil@heuft.com
OOO HEUFT EURASIA
Moscow, RUSSIA
Phone: +7-495-935-8704
eurasia@heuft.com
Operating instructions 3
HEUFT QUALIPLUS B.V.
Deventer, NETHERLANDS
Phone: +31 570 6617 00
netherlands@heuft.com
HEUFT S.A.
Beccar, ARGENTINA
Phone: +54 11 47070936
argentina@heuft.com
HOTLINE and REMOTE
SERVICE
Phone: +49 2636 56 277
Fax: +49 2636 56 256
HEUFT FRANCE S.A.
Brumath, FRANCE
Phone: +33 388 59 1011
france@heuft.com
HEUFT MEXICO S.A. de
Phone: + 52 55 53743280
C.V.
Naucalpan de Juárez,
MEXICO
mexico@heuft.com
INTERNET
www.heuft.com
E-MAIL:
info@heuft.com
HEUFT ITALIA s.r.l.
Vigevano, ITALY
Phone: +39 0381 290423
italy@heuft.com
HEUFT SYSTEMS
TECHNOLOGY Co. Ltd.
Plant #2
Shanghai, CHINA
Phone: +86 216 434 3911
china@heuft.com
Version Date Comments
These technical documents are for your personal use only. They may not be copied or disclosed to a third party without the prior permission of the HEUFT SYSTEMTECHNIK GMBH company - © 03/15.
20.00.001 26/03/2015 Translation of the original German operating instructions
It is possible that this documentation still contains printing errors. However its contents are regularly checked and all future editions are amended accordingly.
We reserve the right to make modifications which may become necessary due to technical progress.
Contents
HEUFT contact addresses............................................................................................................................ 3
Application .................................................................................................................................................... 5
Safety information ......................................................................................................................................... 5
Commissioning ............................................................................................................................................. 6
Installation ................................................................................................................................................ 6
Internet access via LAN (central Internet access) ................................................................................... 6
HEUFT DeviceSupport ............................................................................................................................ 6
Device information .................................................................................................................................. 7
Technical specifications ................................................................................................................................ 9
Operating ................................................................................................................................................... 10
Operating elements..................................................................................................................................... 10
Display with touchscreen ....................................................................................................................... 10
Connections, switches, buttons and light-emitting diodes ..................................................................... 10
The user interface of the HEUFT GATEWAY
Switching on................................................................................................................................................ 12
Reset........................................................................................................................................................... 13
Switching off................................................................................................................................................ 13
Online help.................................................................................................................................................. 14
Spare parts list ............................................................................................................................................ 14
Error messages on the display .................................................................................................................. 14
Troubleshooting .......................................................................................................................................... 15
II
......................................................................................11
Maintenance ............................................................................................................................................. 16
4 Operating instructions
HBDR20010 ENG GATEWAY II 20.00.001
Application
The HEUFT GATEWAY II gateway server makes access to the HEUFT TeleService (remote service) possible for all the HEUFT SPECTRUM
The gateway server has been designed for assembly into an on-site 19 inch cabinet or rack as standard. These are not included in the scope of delivery of the gateway server but can be obtained from HEUFT SYSTEMTECHNIK GMBH as an option.
The device is not intended for operation in potentially explosive areas.
The device must not be used for other purposes than those for which it has been designed.
II
devices.
Scope of delivery
1 HEUFT gateway server as a 19 inch rack
1 device USB stick
Connection cable for the power supply to the gateway server
These operating instructions
Safety information
Danger of electric shock!
Only an electrician is authorised to open the device. Switch the device off beforehand and pull out the power plug.
Unauthorised opening and improper repairs can put the user of the device in danger.
Only trained personnel or HEUFT service technicians are authorised to replace parts.
Moisture and liquids penetrating the device can cause electric shocks or short circuits. Do not allow any liquids to enter the inside of the device.
Switch off the device or leave it switched off until the moisture has evaporated if moisture has penetrated into the electrics / electronics.
Operating instructions 5
Commissioning
Installation
The gateway server has been designed for assembly into an on-site 19 inch cabinet or rack as standard. These are not included in the scope of delivery of the gateway server but can be obtained from HEUFT SYSTEMTECHNIK GMBH as an option.
An electrician authorised by the operator of the control cabinet has to install the gateway server in an on-site control cabinet.
An electrician authorised by the operator of the control cabinet has to connect the control cabinet if the control cabinet in which the gateway server has already been installed is part of the scope of delivery of the device.
A service technician authorised by the HEUFT company generally carries out initial commissioning in accordance with the commissioning instructions.
The network connections between the HEUFT SPECTRUM II devices and the HEUFT GATEWAY assembly commences. Please refer to the PDF documentation (HEUFT HLAN network) which is available as a PDF file on the HEUFT DeviceSupport portal (HEUFT DeviceSupport, page 6) regarding the installation of the network connection.
II
have to be installed on site to the place of installation before
Internet access via LAN (central Internet access)
Requirements concerning the customer's firewall
Changes to the adjustments of the customer's firewall may only be carried out by the network administrator authorised by the customer. The HEUFT service team may not make any changes to the customer's firewall.
The Internet access required for the HEUFT TeleService (remote service) has to be made available on site. The Internet must be accessible via the standard gateway IP configured in the HEUFT GATEWAY result the customer's firewall is responsible for the protection of the network. The connection setup is always initiated by the customer from the HEUFT device and therefore it is not possible to dial in from the outside or even from HEUFT SYSTEMTECHNIK GMBH.
IPsec is used for the connection between the gateway server and the HEUFT TeleService so that secure communication is possible via the Internet. The usual outgoing ports for the IPsec must be enabled in the customer's firewall.
II
. As a
HEUFT DeviceSupport
All the documents for your device are available as PDF files on the HEUFT DeviceSupport portal. You can register on the "www.devicesupport.heuft.com" website if you have not already done so. You will have access to your device documentation and spare parts lists as soon as your access has been activated.
6 Operating instructions
HBDR20010 ENG GATEWAY II 20.00.001
Device information
Customer's network
GATEWAY
II
gateway server
HLAN network
The HEUFT GATEWAY II gateway server makes access to the HEUFT TeleService (remote service) possible for all the HEUFT SPECTRUM
II
devices. It has two Ethernet interfaces which are both protected by a
configurable firewall (port filter).
In addition the HEUFT gateway server can be used as a router for separating the HLAN network with the devices and the rest of the customer's network via the two Ethernet interfaces. The integrated firewall makes it possible to limit the routed data traffic between the two interfaces:
no data exchange via routing
permits Internet protocols [http(s), imap(s), pop3(s), smtp and dns] via routing
permits access to HEUFT devices via routing
•ping
permits configuration only via one LAN port - in this case the other port is blocked for the configuration
via the web interface
permits all protocols via routing
A multi-choice selection is possible. The adjustments of the internal firewall for the LAN port to which the HEUFT devices are connected have to be selected so that incoming connections are permitted by the HEUFT devices.
Please refer to Requirements concerning the customer's firewall, page 6 for information regarding the customer's firewall.
It is not possible to install additional customer applications on the GATEWAY
II
gateway server.
Operating instructions 7
Device USB stick
A USB stick on which the device number of the GATEWAY II has been stuck is part of the scope of delivery of the device.
The stick is inserted in the USB socket during commissioning and remains there permanently. It saves the configuration of the GATEWAY
II
. Changes to the configuration are only saved to the stick if this stick is in the
device socket. The device uses the configuration which has been saved to the stick each time the device starts up.
This stick simply has to be inserted in a new device in order to obtain a functional, fully configured gateway server if the device is faulty. Please refer to the online help on the web interface of the GATEWAY
II
for further
information.
Remote service function monitoring
The "remote service function monitoring" makes it possible to permanently monitor the remote service function.
Typical malfunctions such as separated network connections or a configuration which has not been adapted to new conditions can thus be detected and avoided in an emergency.
8 Operating instructions
HBDR20010 ENG GATEWAY II 20.00.001
Technical specifications
The gateway server uses the LINUX operating system.
Electric power supply
Mains: single-phase alternating current (L, N and PE)
Grounding system: TN-S mains according to IEC 60364-1 / HD 60364-1 / DIN VDE 0100-
100
Nominal voltage: 100 - 240 V power supply unit with wide range input
Frequency: 50/60 Hz
Maximum continuous current: L (230 V): 0.5 A
L (115 V): 1 A
Maximum constant power: L (230 V): 120 W (active power)
L (115 V): 240 W (active power)
Note: The apparent power is used for rating the upstream electrical equipment (e.g. the transformer and the uninterruptible power supply). The active power describes the power consumption.
On-site fuse protection: circuit breaker B, maximum 10 A
Supply line: connection via power plug on the back of the device
- a connection cable for the power supply with a plug with earthing contact (CEE 7/7) is included with the device
Interference suppression / interference immunity:
Protection class: IP 20
Permissible ambient conditions:
Dimensions: 485 mm x 44 mm x 220 mm (W / H / D)
Weight: approximately 4 kg
in accordance with EN55011 in accordance with EN50082-2
operating temperature + 0°C to + 40°C temperature range for storage -20°C to +60°C 10% to 90% relative humidity / non-condensing
1 height unit for assembly in the control cabinet
Operating instructions 9
Operating
Display
Network ports - LAN 1 and 2
not used
Device USB stick
On / off switch
Reset button
Device is switched on
Access to the hard disk
LED lights up: warning of overheating (Troubleshooting, page 15) LED flashes: fan faulty
Operating elements
Display with touchscreen
The display shows the current IP configuration and possible faults.
The IP addresses used are displayed during error-free operation. The IP addresses can be displayed again by touching the touchscreen if an error message is shown.
Connections, switches, buttons and light-emitting diodes
Connections
The connections are pre-configured ex works:
LAN 1: WAN: connection to the Internet (also via an on-site router)
LAN 2: LAN: connection to the HLAN network of the HEUFT devices and the customer's network
The allocation of the connections can be changed on the user interface of the HEUFT GATEWAY
II
.
Switches, buttons and light-emitting diodes
10 Operating instructions
HBDR20010 ENG GATEWAY II 20.00.001
The user interface of the HEUFT GATEWAY
Display of the LAN IP address on the GATEWAY
II
II
The graphical user interface of the GATEWAY II is available for configuring and commissioning the gateway server. The user interface can be opened on the computer in an Internet browser. The PC is not included in the scope of delivery.
Opening the user interface
The user interface of the GATEWAY II can be opened on any computer which is connected to the gateway server via a network.
1. Open an Internet browser on your computer.
2. Enter the IP address of the LAN (1 or 2) in the address field of the browser which connects your computer to the GATEWAY
II
(Connections, page 10). The IP address(es) of the GATEWAY II
show(s) the display of the device.
The user interface of the gateway server is opened.
User name: gateway
Password: gateway
The presetting can be changed.
Operating instructions 11
Switching on
The gateway server is in a control cabinet as standard. The control cabinet has to be opened for operating purposes. There may be live parts in the control cabinet. Therefore only an electrician may operate it.
Observe the safety regulations relating to the other devices in the control cabinet.
1. Open the control cabinet.
2. Switch the gateway server on by briefly pressing the key.
The operating system of the gateway server starts up. The procedure takes approximately 1 minute.
The following appears on the display during this start-up phase:
.
The IP addresses are displayed after starting up. An error message appears if an error has occurred.
3. Close the control cabinet.
The gateway server normally remains on all the time. A TeleService connection via the Internet is only available when a corresponding connection has been started from one of the connected SPECTRUM devices.
II
12 Operating instructions
HBDR20010 ENG GATEWAY II 20.00.001
Reset
The gateway server is in a control cabinet as standard. The control cabinet has to be opened for operating purposes. There may be live parts in the control cabinet. Therefore only an electrician may operate it.
Observe the safety regulations relating to the other devices in the control cabinet.
A reset describes a process which takes the system to a defined status. This may be necessary when the system no longer works as expected and no longer reacts to normal inputs.
The system resumes the status which it had after being switched on by means of the reset.
Certain procedures require the device to be reset.
1. Open the control cabinet.
2. Press the key.
The operating system of the gateway server is shut down and restarted by a reset. This procedure can take 3 to 4 minutes.
The IP addresses can be selected again on the touchscreen display upon completion of the reset.
3. Close the control cabinet.
Switching off
The gateway server is in a control cabinet as standard. The control cabinet has to be opened for operating purposes. There may be live parts in the control cabinet. Therefore only an electrician may operate it.
Observe the safety regulations relating to the other devices in the control cabinet.
1. Open the control cabinet.
2. Press the key briefly. The display lights up.
The operating system of the gateway server is shut down. The display switches off after the shut down.
3. Close the control cabinet.
Operating instructions 13
Online help
The online help for the gateway server can be found on the GATEWAY II interface.
Spare parts list
All the spare parts are listed in the HEUFT DeviceSupport (HEUFT DeviceSupport, page 6).
Error messages on the display
Message Colour Description
USB stick error: removed Red The USB stick has been removed during operation.
The stick is faulty if it has not been removed.
The device is also temporarily operational and functional without a stick.
USB stick error: not present at startup Red The USB stick was not present when starting up
(booting) the last time or is faulty.
Link Error: LAN [1|2] Red LAN [1|2] has been configured but does not have a link
(no connection)
Gateway observation deactivated Orange The gateway function monitoring has been
deactivated.
14 Operating instructions
HBDR20010 ENG GATEWAY II 20.00.001
Troubleshooting
Only an electrician is authorised to open the control cabinet and the gateway server.
LED lights up: warning of overheating
1. Pull out the power plug.
2. Release the screw of the cover sheet.
3. Pull the cover sheet back and remove it.
4. Clean the fan.
5. Replace the cover sheet.
6. Screw down the cover sheet.
Procedure in the event of defects
Device
The device is faulty if the display remains on when starting up or if the display stays empty (dark) after starting up. The device is generally replaced completely (Spare parts list, page 14). The USB stick of the faulty device is inserted into the new device and a functional, fully configured gateway server is obtained.
Further information Error messages on the display, page 14
Operating instructions 15
Maintenance
The device does not include any parts which require maintenance by the operator.
16 Operating instructions
HBDR20010 ENG GATEWAY II 20.00.001