MOTION SENSING 3-WAY WALL SWITCH

The Heath®/Zenith Motion Sensing 3-Way Wall Switch automatically controls indoor lighting:

In AUTO mode, the control automatically turns the light on when you enter the room. The length of time the light stays on is adjustable.

The Heath®/Zenith SL-6107 Motion Sensing 3-Way

OFF AUTO ON

Wall Switch replaces any “3-way” switch. Perfect for rooms or hallways where two wall switches control a single light.

This package includes:

light control

wire connectors

wire jumper

decorative cover plate

mounting hardware

© 2003 DESA Specialty Products™

595-4514-13

Some local building codes may require installation by a qualified electrician.

INSTALLATION

For your safety, turn off power at the fuse or circuit breaker.

Note: A “3-way” circuit controls lights from two separate switches.

If you want to use this product in a single switch circuit or if you want to install more than one motion sensing wall switch, see Special Installations, page 8.

Select a 3-way circuit that controls a light or an outlet to a lamp.

Total lighting must be from 25 to 500 watts incandescent, or 60 to 400 watts fluorescent using a rapid start ballast. Note: May not be used to operate electronic or magnetic ballasts. Less wattage than the minimum may not allow the control to work properly. The switch selected for replacement should be in a place that can detect motion in the desired area.

For easier re-wiring later, mark the house wiring with tape indicating where the wire had been connected.

In the following section you will install a jumper wire at one 3-way switch and replace the other switch with the SL-6107.

*Note: The existing 3-way switch will be referred to as the “Remote Switch” throughout the rest of the installation manual.

-2-

595-4514-13

INSTALLATION

See pages 4 through 6 for detailed instructions for installing and wiring the SL-6107 Wall Switch.

EXISTING LIGHT SWITCH CONFIGURATION

 

WHITE

 

WHITE

WHITE

FROM

 

 

 

 

POWER

BLACK

*COMMON

 

*COMMON

SOURCE

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

(In Wall)

 

 

 

 

BLACK

BLACK

 

 

 

 

SL-6107 SWITCH 1ST ON CIRCUIT

 

WHITE

 

WHITE

WHITE

FROM

 

 

 

ADD JUMPER WIRE

POWER

 

 

 

 

 

 

 

SOURCE

 

 

 

*COMMON

 

 

 

 

 

BLACK BLACK

 

BROWN

RED

 

 

 

 

(In Wall)

 

OFF

AUTO ON

 

BLACK

 

 

 

RED

 

 

 

BLACK

 

SL-6107

 

(From 6107)

EXISTING

 

 

 

 

 

 

 

3-WAY SWITCH

 

SL-6107 SWITCH 2ND ON CIRCUIT

WHITE

WHITE

WHITE

FROM

ADD JUMPER WIRE

 

 

POWER

*COMMON

 

 

 

SOURCE

 

 

 

BLACK

RED

BROWN

BLACK

 

 

(In Wall)

 

 

 

 

 

 

OFF AUTO ON

 

 

BLACK

RED

BLACK

 

 

 

 

EXISTING

 

(From 6107)

 

 

 

SL-6107

3-WAY SWITCH

*COMMON-Used for illustrative Purposes Only. Check Your Switch. The common may be in a different location, depending on the brand of your switch.

RED is used to represent the second wire between two standard three-way switches. This may not be the color used in all installation. If you are not sure about your wiring, call an electrician for installation help. There is also a RED wire on the SL-6107 switch. Check the instructions above closely and do not confuse the two.

595-4514-13

-3-

INSTALLATION

1. Add Jumper At Remote 3-Way Switch.

A jumper wire between the common wire and one of the switched wires is used to supply power to the SL-6107 regardless of the position of the remote switch.

Remove remote switch from the junction box.

The switch may indicate the common

OR

Color of screw may be different for the common

To Red wire of SL-6107 (note color)

Common Switch Lug

COMMON

Hot Wire

Jumper

To brown wire of

SL-6107 (note color)

Connect Jumper at the Remote Switch

Connect the jumper wire to the common lug (usually labeled on the switch) and to either one of the two switched lugs. If you're not sure which lug is common, install the jumper on any two of the wires, and test the jumper as explained on the next page.

-4-

595-4514-13

INSTALLATION

2. Replace Other Switch.

Turn the power off at the circuit breaker.

Remove and disconnect the old switch.

Note: If you can't tell which wire is common, etc., connect the wires in the following steps as best you can, then follow the test on the next page.

Connect the black motion sensor wire to the common wire.

Connect the brown motion sensor wire to the jumpered wire on the remote switch.

Connect the red motion sensor wire to the non-jumpered wire.

Connect the green motion sensor wire to the ground wire.

Jumpered Wire

Brown

Non-Jumpered

Red

Wire Removed

 

from Common

 

Ground Wire

Green

(Green or Bare Wire)

 

Black

ON

AUTO

OFF

Connect the SL-6107 to Existing Wiring

595-4514-13

-5-

INSTALLATION

Test For Correct Common Wire Connection:

Re-install the switch.

Turn the circuit breaker back on.

Leaving the jumpered switch in one position, flip the other 3-way switch on and off.

Lights

Yes

Jumper is

turn on

correct. Go

 

and off.

 

to next page.

No

 

 

 

 

 

 

 

 

 

 

 

 

 

Move one end of the jumper wire to the previously unconnected terminal.

Remove the jumpered switch from the junction box.

Flip the switch with the jumper wire to the other position.

Flip the unjumpered switch on and off.

Turn the power

No

Lights

Yes

Jumper is

off at the

turn on

correct. Go

 

 

circuit breaker.

 

and off.

 

to next page.

-6-

595-4514-13

INSTALLATION

Mount the SL-6107 into the junction box with the two junction box screws.

Turn the circuit breaker back on.

Preset the controls: Time to min. (fully counter-clockwise), Photo Adjustment fully clockwise. Cover the lens with masking tape.

With the motion sensor in the “ON” position, turn the remote switch on and off several times. Go to step 1, 2, or 3, depending on results.

Troubleshooting Wiring Connections

* Turn power off before rewiring!

If light does 1. not turn on:

If light turns on in

2.only one position of remote switch:

Exchange*

Control's

Red Black

wires.

Exchange*

Control's

Red Brown

wires.

Test again. Go to 2 or 3.

Test again. Go to 1 or 3.

 

If light turns on

 

Set sensor to “AUTO”. Wait for the

3.

with remote

 

unit to warm up (up to 1 min.). If

switch in either

the remote switch can turn the

 

position:

 

lights on, it's OK. Otherwise:

 

 

 

 

Exchange* Control's

Black Brown wires. Remove the tape. Go to the next page.

595-4514-13

-7-

Heath Zenith SL-6107 User Manual

SPECIAL INSTALLATIONS

For single switch installations, connect the wall switch as shown here.

SINGLE SWITCH INSTALLATION

 

BLACK

BROWN

BLACK

 

 

FROM

 

RED

POWER

OFF AUTO ON

SOURCE

 

 

 

SL-6107

 

 

 

WHITE

BLACK

WHITE

If you want to have motion sensors at both 3-way switches, connect them as shown below. The minimum wattage may increase to 100 W for fluorescent and 50 W for incandescent lighting.

EXISTING LIGHT SWITCH CONFIGURATION

FROM

WHITE

WHITE

WHITE

 

 

 

POWER

BLACK

*COMMON

*COMMON

SOURCE

 

 

 

RED

 

 

 

 

 

 

(In Wall)

 

BLACK

BLACK

 

 

 

2 SWITCH INSTALLATION

FROM

WHITE

 

 

WHITE

 

WHITE

POWER

 

 

 

 

 

 

SOURCE

 

 

 

 

 

 

BROWN

 

 

 

BROWN

 

 

 

 

BLACK

 

 

BLACK

RED

 

 

 

BLACK

 

 

OFF

AUTO

ON

 

OFF AUTO

ON

(From 6107)

 

 

 

RED

BLACK

 

 

 

 

 

 

 

SL-6107

(From 6107)

SL-6107

 

 

 

 

 

 

 

 

RED (In Wall)

 

 

*COMMON-Used for illustrative Purposes Only. Check Your Switch. The common may be in a different location, depending on the brand of your switch.

RED is used to represent the second wire between two standard three-way switches. This may not be the color used in all installation. If you are not sure about your wiring, call an electrician for installation help. There is also a RED wire on the SL-6107 switch. Check the instructions above closely and do not confuse the two.

-8-

595-4514-13

ADJUSTMENT

PHOTO SENSITIVITY

ON

AUTO

OFF

20 Minutes

Any Light Level

Dark

++

Press in with screwdriver.

T I M E

L I G H T

Swing out cover to remove.

 

5 Seconds

 

 

The sensor can be prevented from turning on lights when there is already enough light in the room. Use a small screwdriver to set the light level using this diagram as a guide. In the fully clockwise position, the sensor turns on lights even in full daylight. In the fully counter-clockwise position, the sensor only turns on lights when the surrounding light level is very low.

With the switch in the AUTO position and the light at the desired level for the lights to turn on, put the LIGHT control to the minimum dark (fully counter-clockwise) position. Wait for the lights to turn off.

Move your hand in front of the sensor. While moving your hand in front of the sensor, slowly turn the LIGHT adjustment clockwise until the lights controlled by the sensor come on.

595-4514-13