Heath Zenith SL-4300 User Manual 2

0 (0)

Diecast Motion

Sensing Porch Light

Meets the ENERGY STAR® guidelines when DualBrite® function is off.

SL-4300

Features

Light comes on when motion is detected.

Automatically turns light off.

Half power Accent lighting.

Photocell keeps the light off during daylight hours.

This package includes:

Porch Light

Easy to use Universal Mounting Bracket

Mounting Hardware

Wire Nuts

Lens Shield

Requirements

The light control requires 120 volts AC.

If you want to use Manual Mode, the control must be wired through a switch.

Some electrical codes require installation by a qualified electrician.

OPERATION

Mode:

On-Time

Works: Day Night

 

 

 

 

Test

5 Sec

x

x

Auto/

1, 5, or 10 min

 

x

Accent

Off, 3, 6 Hr, to Dawn

 

x

 

 

 

 

Manual

Until Dawn*

 

x

 

 

 

 

* resets to Auto Mode at dawn.

Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate.

TEST

Set the ON-TIME switch

 

ON-TIME

on the sensor to TEST.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEST 1 5 10 MIN

AUTO

 

 

 

 

 

 

 

Set ON-TIME switch to

 

ON-TIME

 

 

 

 

 

 

 

 

1, 5, or 10 minutes.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TEST 1 5 10 MIN

 

 

 

 

 

 

 

 

 

MANUAL MODE

Manual mode only works at night because daylight returns the sensor to AUTO.

Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.

Manual mode works only with the ON-TIME switch in the 1,

5, or 10 position.

1 Second OFF

then...

... back on.

Mode Switching Summary

 

TEST

 

 

 

 

ON-TIME Switch at 1, 5, or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 minutes

 

AUTO

 

 

 

 

 

Flip light switch off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for one second then

MANUAL MODE

 

 

 

back on*

 

 

 

* If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the AUTO mode.

Before installation,record the model number listed inside the fixture.Attach receipt in case of possible warranty issues.

Model Number:

© 2007 HeathCo LLC

598-1183-03

Heath Zenith SL-4300 User Manual 2

DualBrite® Dimmer Control

Light comes on half bright for selected time after dusk (Off,3hr.,6hr.,untildawn).SelectingOFFdisablesthis feature.The motion sensing features will continue to work as described in this manual.If motion is sensed, the light turns on full bright for the ON-TIME (1, 5, or

10 minutes) then returns to dim mode.

Disassemble Light Fixture

1.Remove two decorative nuts from light fixture cover.

2.Remove cover from base.

Light Fixture Base

Light Fixture Cover

Decorative Nut

3.Remove two decorative nuts from fixture screws in universal mounting bracket.

4.Remove universal mounting bracket from base.

Universal

Mounting

Bracket

Decorative Nut

DUAL

BRITE

 

DUSKWN

3 6

TO DA

OFF

 

 

 

 

10 MIN

1

5ME

TESTON-TI

 

Install universal Mounting Bracket

For best performance, mount the fixture at least 8 feet (2.4 m) above the ground.

WARNING: Turn power off at circuit breaker or fuse.

1.Tighten the two fixture screws finger tight.

2.Attach universal mounting bracket to junction box securely with the two screws provided.

Junction Box

Universal Mounting

Bracket

Junction Box Screw

Fixture Screw (Tightened

Finger Tight)

Wiring Light Fixture

1.Connect the junction box wires and the fixture wires together as shown in the following diagrams.

CAUTION: DO NOT remove wire connector from RED wire or connect the RED wire unless you want to control other lights from this motion sensor fixture.

2. Twist and secure wires with wire nuts.

Note: If you have a metal junction box use the recommended grounding method shown in the following illustration.If you are uncertain about the grounding method, consult your local building code.

598-1183-03

Bare Ground Wire

 

Ground Screw

Metal Junction

 

Pigtail (not

Box

 

supplied)

 

 

White to White

Fixture Bare

Black to Black

Ground Wire

Recommended Grounding Method

Black to Black

White to White

Ground to Ground

One Motion Sensing Light

Ground to Ground

Black to Black

White to White

Two Motion Sensing Lights (Working Independently)

Other Wiring Options

This fixture can be wired to control another standard or motion sensing light fixture(s). See the following wiring diagrams for proper connections.

Note: All wiring should be run in accordance with the National Electrical Code through conduit or another acceptable means. Contact a qualified electrician if there is any question as to the suitability of the system.

598-1183-03

When controlling an additional light fixture(s), the maximum wattage of the motion sensor on this fixture should be observed. See illustration below for an example of a maximum lamp wattage load calculation.

 

Maximum Lamp

 

Wattage Rating

 

for Light Fixture –

 

100 Watts

Maximum Load for

CONTROLLING Fixture

Motion Sensor –

 

200 Watts

Maximum Lamp

 

 

Wattage Rating

 

for Light Fixture –

 

100 Watts

 

CONTROLLED Fixture 1

 

TOTAL Load for

 

Motion Sensor –

 

200 Watts

IMPORTANT: When determining the maximum lamp wattage rating of the fixture to be controlled, refer to the maximum lamp wattage label on the fixture and not the wattage rating on the lamp(s) currently installed in the fixture.

Black to Black

 

 

 

 

 

 

 

 

 

 

 

 

Red to Black

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

White to White

 

 

 

 

 

 

 

 

 

 

Ground to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ground

Motion Sensing Light Standard Light Fixture

Wiring Motion Sensing Light to Control Standard Fixture

Ground to Ground

Black to Red

Black to Black

and Black

Red to Black

 

White to White

 

 

 

 

 

 

 

Motion Sensing Light

Controlled Motion

 

 

 

Sensing Light

Wiring Motion Sensing Light to Control Another Motion Sensing Light

It is also possible to wire two motion sensing lights so that either unit will turn on both lights at the same time(dualcontrolledsystem).Itisrecommendedthat onlypeoplewithelectricalwiringexperienceattempt this configuration. Please call our customer service number (1-800-858-8501) before attempting this wiring. If the dual controlled wiring is not done correctly, it can destroy both motion sensing fixtures and void your warranty.

Install Fixture Base to Junction Box

1.Push wires into the junction box.

2.Slide light fixture base onto fixture screws and tighten decorative nuts snugly against the base.

3.Install four candelabra base light bulbs (25 Watts maximum each).

4.Refer to TESTING section before installing cover.

5.After switches are set and testing is complete, use the 2 decorative nuts to install the cover.

Junction Box

25 Watt Candelabra

Fixture Screw

 

Base Bulb

 

DUAL

BRITE

 

 

DUDASKWN

 

 

3

6

TO

 

OFF

 

 

N

 

 

10 MI

1

5

E

 

TESTON-TIM

 

 

Decorative Nut

Testing

1. Turn on the circuit breaker and light switch.

Note: Sensor has a 1 1/2 minute warm up period before it will detect motion.When first turned on wait 1 1/2 minutes.

2. Set the ON-TIME switch to the TEST position and the DualBrite® switch to the OFF position.

DUAL

BRITE

 

 

DUDASKWN

 

 

3

6

TO

 

OFF

 

 

N

 

 

10 MI

 

1

5ME

 

TESTON-TI

 

 

Sensor

Lens

DualBrite®

DUSK

OFF 3HR 6HR TO DAWN

TEST 1 5 10 MIN

ON-TIME

3.Walk through the coverage area noting where you are when the lights turn on. In TEST mode, light will stay on for only 5 seconds then turn off.

4.AdjusttheSENSITIVITYtoincreaseordecrease the range as needed. Too much sensitivity may cause false triggering due to heat sources in the coverage area (see Adjustment of Coverage Area or Troubleshooting section).

 

 

SENSITIVITY

SEN+

SITIVITY

+

5.Set the amount of ON-TIME you want the light to stay on after motion is detected (1, 5, or 10 minutes).

6.Set the amount of time you want the light to stay on in the Accent mode (Off, 3 hours, 6 hours, or dusk-to-dawn).

Note: Meets the ENERGY STAR® guidelines when DualBrite® function is off.

360°

8 ft. (2.4 m)

30 Feet (9.1 m) in all Directions

Maximum Range Coverage Angle*

(Top View)

* Without lens shield installed.

598-1183-03

The sensor is less sensitive to motion directly towards it and more sensitive to motion across coverage area.

Motion

Motion

Sensor

Least Sensitive

Most Sensitive

Adjustment of Coverage

Area

The sensor on this light fixture detects “motion” by the movement of heat (body heat) across the coverage area. However, following are examples of objects that also produce heat and can cause the sensor to false trigger:

• Pools of Water

• Air Conditioners

• Dryer Vents

• Fenced-In Animals

• Heating Vents

• Automobile Traffic

If you suspect that a heat source of this type is falsely triggering the sensor and reducing the sensitivity does not solve the problem, then a lens shield (included) can be installed. The plastic lens shield is divided into 6 sections. Each section will reduce the coverage angle by 30 degrees. Also, the tip of each section may be removed to change the effective range of the sensor.

Lens

 

Shield

Area

 

Blocked

 

Effective

 

Coverage Area

Lens

(Top View)

Area

Shield

 

Blocked

Portion

Removed

598-1183-03

1.

Break off

the

Lens Shield

 

 

 

amount of lens

 

 

 

 

 

 

 

shield

needed

 

 

 

 

to block the de-

DU

AL BRITE

 

sired

area

of

 

SK

 

 

 

DUDAWN

 

 

3 6

TO

 

OFF

 

 

 

 

 

 

5

10 MIN

 

coverage.

 

 

1-TIM

 

 

 

TESTON

 

 

 

 

 

 

2.

Cut

desired

 

 

 

 

amount of foam

 

 

 

 

tape needed to

 

 

Sensor Lens

 

adhere the lens

 

 

 

 

 

 

 

shield to the sensor lens.

 

 

3.Remove paper backing from one side of cut foam tape and adhere foam tape to inside of lens shield.

4.Removepaperbackingfromothersideofcutfoam tape and adhere lens shield to sensor lens.

5.Retest to confirm that the sensor is no longer false triggering.

Note: To help determine amount of lens shield required, apply small sections one at a time. Additional sections can be applied if necessary.

SPECIFICATIONS

Range............................

Up to 30 ft. (9.1 m)

 

[varies with surrounding

 

temperature].

Sensing Angle...............

360°

Electrical Load...............

Up to 100 Watt

 

Maximum Tungsten

 

Incandescent (Up to 25

 

Watt Maximum each

 

lampholder).

Bulb Type.......................

Candelabra Base, Type

 

“B”, 25 Watt Maximum

Sensor Capacity............

Up to 200 Watt (1.7 A.)

 

Maximum Tungsten

 

Incandescent

Power Requirements.....

120 VAC, 60 Hz

Operating Modes...........

TEST, AUTO/ACCENT,

 

and MANUAL MODE

ON-Timer......................

1, 5, 10 minutes

DualBrite® Timer...........

Off, 3, 6 Hrs, Dusk-to-

 

Dawn

HeathCo LLC reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

TROUBLESHOOTING GUIDE

SYMPTOM

POSSIBLE CAUSE

 

 

 

Light will not

1.

Light switch is turned off.

come on.

2.

Bulbs are loose or burned out.

 

3.

Fuse is blown or circuit breaker

 

 

is turned off.

 

4.

Daylight turn-off is in effect (re-

 

 

check after dark).

 

5.

Incorrect circuit wiring, if this is

 

 

a new installation.

 

 

 

Light comes on

1.

Sensor may be installed in a

in daylight.

 

relatively dark location.

 

2.

Sensor is in Test. (Set control

 

 

switch to an ON-TIME position.)

 

 

 

Light comes on

1.

Sensor may be sensing small

for no apparent

 

animals or automobile traffic.

reason.

 

(Reduce sensitivity.)

 

 

 

SYMPTOM

POSSIBLE CAUSE

 

 

 

Light stays on

1.

There is a heat source like an air

continuously.

 

vent,dryervent,orbrightly-painted,

 

 

heat-reflectivesurfaceinthecover-

 

 

age area. (Install shield on sensor

 

 

in the direction of heat source.)

 

2.

Light control is in Manual Mode.

 

 

(Switch to Auto.)

 

3.

Light control is in DualBrite®

 

 

mode.

 

4.

Sensitivity is set too high.(Reduce

 

 

sensitivity.)

 

 

Light flashes on

1. Sensor is in theTest mode.(While

and off.

 

in TEST mode, light only stays on

 

 

for 5 seconds.)

 

 

 

Light does not

1.

Nearbylarge,light-coloredobjects

stay on in Man-

 

reflecting light may trigger the

ual mode.

 

shut-off feature.Do not point other

 

 

lights at the sensor.

 

 

 

Technical Service

Please call 1-800-858-8501 (English speaking only) for assistance before returning product to store.

If you experience a problem, follow this guide.You may also want to visit our Web site at: www.hzsupport. com. If the problem persists, call* for assistance at 1-800-858-8501 (English speaking only), 7:30 AM to 4:30 PM CST (M-F). You may also write* to:

HeathCo LLC

P.O. Box 90004, Bowling Green, KY 42102-9004

ATTN: Technical Service

* If contacting Technical Service, please have the following information available: Model Number, Date of Purchase, and Place of Purchase.

No Service Parts Available for this Product

FIVE YEAR LIMITED WARRANTY

This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state or province to province.

For a period of five years from the date of purchase, any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you.

Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs, batteries, and other expendable items are not covered by this warranty. Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, unauthorized service, or return shipping charges.

This warranty covers only HeathCo LLC assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products.

THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES.

REPAIR OR REPLACEMENT SHALL BETHE SOLE REMEDY OFTHE CUSTOMER ANDTHERE SHALL BE NO LIABILITY ON THE PART OF HeathCo LLC FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITEDTO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEEABLE.Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Please keep your dated sales receipt, it is required for all warranty requests.

598-1183-03