Heath Zenith 6180, 6280 User Manual

0 (0)
Heath Zenith 6180, 6280 User Manual

Decorative Wireless Chime

6180 Series and 6280 Series

This package includes (Style of push button and chime may vary from illustrations):

Wireless chime

Wireless push button w/battery

Hardware pack

You'll need to buy 3 "D" alkaline batteries for the chime (Clock chime models require additional "AA" battery). In typical use, alkaline batteries will last up to three years.

1. Install alkaline type A23 12 volt push button battery. Remove back of case by pushing in tab on bottom with a small screwdriver. Make sure battery is oriented properly (see page 4).

 

Chime

 

 

 

Volume

 

 

Cover

 

Jumpers

Mounting

 

-

+

-

Tabs

 

Battery

Battery

Battery

 

+

-

+

 

 

 

Case Style "A" (Shown

In Vertical Position)

Chime

Volume

Jumpers

2.Install 3 alkaline "D" batteries. Make sure batteries are oriented properly.

The base may be mounted in a vertical or horizontal position. The correct mounting position will depend upon the specific cover (model).

3.Test range. Temporarily position chime and push button where you want them mounted. Press push button to verify chime and push button work properly. If chime does not sound, see Troubleshooting.

Case Style "B"

© 2003 DESA Specialty Products™

595-5506-09

4. Mount push button and chime.

Keyholes

21116 "

Holes

21

/2

 

 

"

Case Style "A"

Back

Use either screws or double sided tape to mount push button.

To mount with screws, remove back of case by pushing in tab on bottom with a small screwdriver.

Attach back of case to door jamb or wall. Snap front of push button on.

When attaching push button using double sided tape, make sure the surface of the door jamb or wall is clean.

Case Style "A": Chime can be mounted by using 3 holes in the back of case, or by using 2 screws with keyholes.

Case Style "B": Chime can be mounted by using 1 large screw (provided) with saw-tooth hanger. Securely fasten saw-tooth hanger to rear of case using screws (or nails) provided (see illustration on page 1). It can also be placed on a flat surface.

5.Slide chime cover onto top of chime. Use technique for the style case you have. Mounting groove in cover will align with mounting tab(s) on base.

-2-

595-5506-09

Battery
Cover
Time Setting
Dial

Clock Chimes

Battery Installation and Setting Time

Note: This feature is only available on specific models.

1. Install battery into clock. Firmly grasp brass ring and carefully pull forward to remove clock assembly from front of chime. Gently pull off battery cover located on back of clock assembly. Install "AA" battery according to polarity marks inside battery chamber. Replace battery cover.

2.Set time. With battery cover removed, turn

time setting dial on back of clock assembly until time is correct. Replace battery cover. Replace clock assembly into chime face by pressing assembly gently into hole on chime face.

3.Install batteries into chime. Remove clock

chime back. Grasp cutouts on back of chime with fingers. Gently push back up and pull lower part of back out to remove. Install 3 alkaline "D" batteries according to polarity marks inside battery chamber. Replace back of chime by following the above instructions in reverse (see illustration on page 1).

Code and Tune Settings

Code Settings

Note: Most installations will not require you to change any jumpers on your chime and push button.

The push button and chime communicate by using a code that can be changed by removing and/or adding jumpers on both the push button and chime. The code is factory set; however, there are 128 selectable codes that allow you to expand your system and prevent outside interference. Other wireless products may cause interference and the system may not function properly. Follow the instructions below for setting a new code.

1.Open the cases and locate the jumpers on both the push button and chime (See illustration on page 4).

2.The push button and chime both have eight different jumper locations. The jumper positions 1 through 7 are used for setting the code.

3.To change the code, add and/or remove jumpers as needed. It is recommended to only change one jumper at a time and then check to see if system is functioning properly. Note: Jumpers in positions 1 through 7 must be exactly the same for both the push button and chime for this system to function.

595-5506-09

-3-

Tune Settings

Your Heath®/Zenith wireless chime has different selectable tunes: Ding (one note), Ding-Dong (two note), or Westminster (eight note) (Available on selected Heath®/Zenith chimes). The factory setting is for the Ding-Dong tune (or Westminster, when available). This tune can be changed by following the instructions below.

Ding (one note tune)

Push Button: Add a jumper to location 8.

Ding-Dong (two note tune)

Push Button: Remove jumper from location 8. Chime: Remove jumper from location 8.

Westminster (Eight note tune) (Available on selected Heath®/Zenith chimes) Push Button: Remove jumper from location 8.

Chime: Add a jumper to location 8.

Note: All models have both front and back door tune capabilities. You may purchase any Heath®/Zenith wireless push button for a second entrance. We recommend the back door use the Ding tune and the front door use the Ding-Dong tune (or Westminster tune, available on selected Heath®/Zenith chimes). Models that include two push buttons will come factory set for front and back doors. Decals on the rear of the push button will indicate its setting.

Inside Chime

ry

mi C

 

h

 

e

 

V

 

o

 

l

 

u me

 

12 345 678

B

Tune Setting

 

ry

(Not used on

all models)

 

Push Button Battery Replacement

Install an alkaline type A23 12 Volt battery. See diagram inside push button for correct battery orientation.

2 1 4 3

678 5

*Code Settings 1-7 Must Match Both Push Button and Chime

Tune

Inside Push Setting

Button

Note: Some models might require the use of tweezers to remove and replace the jumpers.

-4-

595-5506-09

Troubleshooting

Chime does not sound:

Make sure push button and chime codes are the same (See pages 3 and 4).

Check orientation of push button battery (See page 4).

Check charge of push button and chime batteries, replace if necessary.

Batteries seem OK, but the chime does not work when installed:

Do not mount chime or push button on metal or near metal studs. This reduces the transmitter range. Use 1/4" to 1/2" (6 to 13 mm) wood shims to move chime or push button off metal surface.

Concrete floors may reduce range. Move chime away from floor.

Try locating chime closer to push button.

The range of the wireless chime can vary with location, temperature and battery condition.

Technical Service

(Do Not Send Products)

If you experience a problem, follow this guide. You may also want to visit our Web site at: www.desatech.com. If the problem persists, call* for assistance at 1- 800-858-8501, 7:30 AM to 4:30 PM CST (M-F). You may also write* to:

DESA Specialty Products™

P.O. Box 90004, Bowling Green, KY 42102-9004 ATTN: Technical Service Specialty Products

* If contacting Technical Service, please have the following information available: Model Number, Date of Purchase, and Place of Purchase.

No Service Parts Available for this Product

Regulatory Information

This device (SL-6180-RX-A, WB-94A-TX, or WB-97-TX) complies with Part 15 of the FCC Rules and RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

The term “IC:” before the radio certification number only signifies that Industry Canada technical specifications were met.

The user is cautioned that changes or modifications not expressly approved by the party responsible for regulatory compliance could void the user’s authority to operate the equipment.

595-5506-09

-5-

LIMITED WARRANTY

This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state or province to province.

For a specified period depending upon model (see chart below) from the date of purchase, any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you. Batteries are not covered. To obtain a refund or a replacement, return the product to the place of purchase.

Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs and other expendable items are not covered by this warranty. Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety. This warranty does not include reimbursement for inconvenience, installation, setup time, loss of use, or unauthorized service.

This warranty covers only DESA Specialty Products™ assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products.

THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMERANDTHERESHALLBENOLIABILITYONTHEPARTOFDESASPECIALTY PRODUCTS™ FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIALDAMAGES,INCLUDINGBUTNOTLIMITEDTOANYLOSSOFBUSINESSOR PROFITS, WHETHER OR NOT FORESEEABLE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Retain receipt for warranty claims.

Model

Warranty Period

6280, 6281, 6282

3 Years

6180 Series, 6283, 6284, 6285

5 Years

 

 

DESA Specialty Products™ reserves the right to discontinue and to change specifications at any time without notice without incurring any obligation to incorporate new features in previously sold products.

-6-

595-5506-09

Loading...