Heat Controller VCH Ceiling Cassette Owner's Manual

0 (0)

OWNER’S MANUAL

VMH 09/12/18/27/36 InverterFlex

Version C

Single, Dual, Tri or Quad Zone Ductless Mini-Split System

B-VCH12FC-1 and B-VCH18FC-1

Version C

Ceiling Cassette

Heat Controller, Inc. • 1900 Wellworth Ave. • Jackson, MI 49203 • (517)787-2100 • www.heatcontroller.com

VMH InverterFlex Mini-Split

OWNER’S MANUAL

Heat Controller, Inc.

Table of Contents

 

 

Safety Precautions

 

 

Warning....................................................................................................

 

2

Caution.....................................................................................................

 

2

Operating Instructions

 

 

Identification of Parts................................................................................

 

3

Display and Remote Controller Features..............................................

4-5

Operating Conditions and Manual Operation...........................................

6

Airflow Direction Control...........................................................................

 

7

Operation Modes......................................................................................

 

8

Care and Maintenance

 

 

Care and Maintenance...........................................................................

 

10

Operation Tips

 

 

Typical Operational Occurrences............................................................

 

12

Troubleshooting Tips

 

 

Troubleshooting Tips..............................................................................

 

14

!Caution

Contact an authorized service technician for repair or maintenance of this unit.

Contact the installer for installation of this unit.

Installation work must be performed in accordance with local and national electrical codes and standards by authorized personnel only.

1

Heat Controller, Inc.

OWNER’S MANUAL

VMH InverterFlex Mini-Split

To prevent injury to the user, other people and/or to property, the following instructions must be followed. Incorrect operation due to ignoring these instructions may cause harm or damage. The seriousness is classified by the following indications:

!WARNING! This symbol indicates the possibility of death or serious injury.

!CAUTION! This symbol indicates the possibility of injury or damage to property.

Meanings of symbols used in this manual are as shown below:

Never do this.

!Always do this.

!WARNING!

!CAUTION!

• Do not attempt to install this air conditioner by yourself.

• This unit contains no user-serviceable parts. Always consult authorized service personnel for repairs.

• Do not insert fingers or objects into the outlet or intake grilles.

• Do not start and stop air conditioner operation by disconnecting the power supply.

• Take care not to damage the power supply wiring.

• In the event of a malfunction (burning smell, etc.), Immediately stop operation, disconnect the power supply, and consult authorized service personnel.

• Provide occasional ventilation during use.

• Do not direct air flow at fireplaces or heating apparatus.

Avoid installing the air conditioner near a fireplace or other heating apparatus.

Do not climb on, or place objects on, the air conditioner.

Do not hang objects from the indoor unit.

Do not set flower vases or water containers on top of the air conditioner.

Do not expose the air conditioner directly to water.

Do not operate the air conditioner with wet hands.

Turn off power source when not using the unit for extended periods.

Do not drink the water drained from the air conditioner.

Connection valves become hot during Heating; handle with care.

Do not apply any heavy pressure to evaporator fins.

Operate only with air filters installed.

Do not block or cover the intake or outlet grille.

Ensure that any electronic equipment is at least 3 feet (1m) away from either the indoor or outdoor units.

Do not use inflammable gases near the air conditioner.

2

Heat Controller VCH   Ceiling Cassette Owner's Manual

VMH InverterFlex Mini-Split

OWNER’S MANUAL

Heat Controller, Inc.

 

 

 

Single-quad zone

 

Air filter

Single to

 

tri zone

Remote Controller

 

Single-dual zone

Base valves

Grille

3

Heat Controller, Inc.

OWNER’S MANUAL

VMH InverterFlex Mini-Split

 

 

 

Ductless Mini-Split

Display Window and Features:

Displays the selected fan

speed:

This display is separated into five zones. Each zone illuminates based on the com- pressor’s frequency. For example, higher frequency will illuminate more zones.

(For heat pump models only):

mode.

Displayed when TURBO function is selected in cooling or in heating modes. This air conditioner is equipped with an ionizer, which generates ions to remove microscopic particles from the air. Rooms become healthier for those suffering from asthma or allergies with the use of this feature.

Displays the current set temperature when the air conditioner is in operation. When SELF CLEAN feature is activated, its displays “SC”.

Remote Controller Features - Ductless High Wall Mount. ONLY

The remote controller comes with a FOLLOW ME feature which allows the remote controller to act as a thermostat. This allows the unit to sense the temperature at the location of the remote controller, rather than sensing the temperature at the indoor unit. The indoor unit is installed high on a wall, thus the thermostat on the remote controller will provide a more accurate temperature reading for the room. Consult the remote controller manual for more information. NOTE: The ceiling cassette does NOT come with this feature.

4

VMH Inverter-Flex Mini-Split

OWNER’S MANUAL

Heat Controller, Inc.

 

 

 

Infarred signal receiver

Manual button

DISPLAY PANEL

jOperation Lamp

kTime Indicator

mAlarm Indicator

•Defrost/Fan Indicator

jOPERATION lamp

This indicator illuminates when the unit is operational.

kTIMER Indication lamp

Lights up during Timer operation.

DEF./FAN Indication lamp

Lights up when the air conditioner starts defrosting automatically in heating operation or fan only mode is selected

mALARM Indication lamp

Flashes an error code sequence when malfunction occurs.

nMANUAL button

This button is used to operate the unit temporarily in case you misplace the remote controller or its batteries are exhausted. One press of the manual control button will lead to the forced AUTO operation. If press the button twice within five seconds, the unit will operate under forced COOL operation. The forced COOL operation is used for testing purposes only, please do not choose it unless it is necessary.

5

Loading...