Hearth and Home Technologies R-CORNER-TRC, PIER-TRC, L-CORNER-TRC, ST-TRC User Manual

0 (0)

Models:

Pier-TRC

ST-TRC

L-Corner-TRC

R-Corner-TRC

Installers Guide

Underwriters

Laboratories Listed

WARNING: IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.

-Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

-What to do if you smell gas

Do not try to light any appliance.

Do not touch any electrical switch.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

-Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

Printed in U.S.A. Copyright 2003

Heat-N-Glo, a division of Hearth & Home Technologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044

READ THIS MANUAL BEFORE INSTALLING OR OPERATING THIS APPLIANCE. THIS INSTALLERS GUIDE MUST BE LEFT WITH APPLIANCE FOR FUTURE REFERENCE.

WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY, OR THE GAS SUPPLIER.

1.This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) home, where not prohibited by local codes.

2.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

Please contact your Heat-N-Glo dealer with any questions or concerns. For the number of your nearest Heat-N-Glo dealer, please call 1-888-427-3973.

This product is covered by one or more of the following patents: (United States) 4,112,913; 4,408,594; 4,422,426; 4,424,792; 4,520,791; 4,793,322; 4,852,548; 4,875,464; 5,000,162; 5,016,609; 5,076,254 5,191,877; 5,218,953; 5,328,356; 5,429,495; 5,452,708; 5,542,407; 5,613,487; (Australia) 543790; 586383; (Canada) 1,123,296; 1,297,746; 2,195,264; (Mexico) 97-0457; (New Zealand) 200265; or other U.S. and foreign patents pending.

501-900 REV. O 2/03

1

SAFETY AND WARNING INFORMATION

READ and UNDERSTAND all instructions carefully ! before starting the installation. FAILURE TO

FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty.

Prior to the first firing of the fireplace, READ the

! Using Your Fireplace section of the Owners Guide.

DO NOT USE this appliance if any part has been ! under water. Immediately CALL a qualified service

technician to inspect the unit and to replace any part of the control system and any gas control which has been under water.

! THIS UNIT IS NOT FOR USE WITH SOLID FUEL.

Installation and repair should be PERFORMED by a ! qualified service person. The appliance and venting

system should be INSPECTED before initial use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is IMPERATIVE that the unit’s control compartment, burners, and circulating air passageways BE KEPT CLEAN to provide for adequate combustion and ventilation air.

Always KEEP the appliance clear and free from

!combustible materials, gasoline, and other flammable vapors and liquids.

NEVER OBSTRUCT the flow of combustion and

!ventilation air. Keep the front of the appliance CLEAR of all obstacles and materials for servicing and proper operations.

Due to the high temperature, the appliance should

!be LOCATED out of traffic areas and away from furniture and draperies. Clothing or flammable material SHOULD NOT BE PLACED on or near the appliance.

Children and adults should be ALERTED to the

!hazards of high surface temperature and should STAY AWAY to avoid burns or clothing ignition. Young children should be CAREFULLY SUPERVISED when they are in the same room as the appliance.

These units MUST use one of the vent systems ! described in the Installing the Fireplace section of

the Installers Guide. NO OTHER vent systems or components MAY BE USED.

This gas fireplace and vent assembly MUST be

! vented directly to the outside and MUST NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance MUST USE a separate vent system. Common vent systems are

PROHIBITED.

INSPECT the external vent cap on a regular basis to ! make sure that no debris is interfering with the air

flow.

! The glass door assembly MUST be in place and sealed, and the trim door assembly MUST be in

place on the fireplace before the unit can be placed into safe operation.

DO NOT OPERATE this appliance with the glass

!door removed, cracked, or broken. Replacement of the glass door should be performed by a licensed or qualified service person. DO NOT strike or slam the glass door.

The glass door assembly SHALL ONLY be

!replaced as a complete unit, as supplied by the gas fireplace manufacturer. NO SUBSTITUTE material may be used.

DO NOT USE abrasive cleaners on the glass door

!assembly. DO NOT ATTEMPT to clean the glass door when it is hot.

Turn off the gas before servicing this appliance. It is

!recommended that a qualified service technician

perform an appliance check-up at the beginning of each heating season.

Any safety screen or guard removed for servicing

!must be replaced before operating this appliance.

DO NOT place furniture or any other combustible

!household objects within 36 inches of the fireplace front.

2

TABLE OF CONTENTS

 

Safety and Warning Information ...............................................

2

Service Parts Lists ....................................................................

4

Section 1: Approvals and Codes ............................................

12

Approval Listings and Codes .....................................................

12

Appliance Certification ...............................................................

12

Installation Codes ......................................................................

12

High Altitude Installations ............................................................

12

Section 2: Getting Started ......................................................

13

Introducing the Heat-N-Glo Gas Fireplaces ................................

13

Pre-installation Preparation ........................................................

13

Section 3: Installing the Fireplace .........................................

17

Step 1

Locating the Fireplace ................................................

17

Step 2

Framing the Fireplace .................................................

17

Step 3

Installing the Vent System ...........................................

20

u A. Vent System Approvals ..........................................

20

 

B. Installing Vent Components ...................................

27

 

C. Vent Termination....................................................

30

Step 4

Positioning, Leveling, and

 

 

Securing the Fireplace ................................................

33

Step 5

The Gas Control Systems ..........................................

33

Step 6

The Gas Supply Line ..................................................

34

Step 7

Gas Pressure Requirements ......................................

34

Step 8

Wiring the Fireplace ....................................................

35

Step 9

Finishing .....................................................................

37

Step 10 Installing Trim, Logs, and Ember Material .....................

38

 

Installing the Trim ........................................................

38

 

Positioning the Logs ...................................................

38

 

Shutter Settings ..........................................................

38

 

Placing the Ember Material .........................................

38

Step 11

Before Lighting the Fireplace ......................................

39

Step 12

Lighting the Fireplace ..................................................

39

After the Installation ....................................................................

39

u Section 4: Maintaining and Servicing Your Fireplace .........

40

u = Contains updated information.

 

3

Service Parts

(NG, LP) Exploded Parts Diagram (GN, PL) Vue éclatée des pièces

Pier-TRC

Beginning Manufacturing Date: 6-97

Ending Manufacturing Date: ______

16

9

15

10

Standing Pilot

3

 

11

1

12

 

5

4

3

7

14

9

6

2

8 Log Assembly

13

*Part number list on following page.

*La liste des numéros de pièce se trouve à la page suivante.

4

(NG, LP) Exploded Parts Diagram / Vue éclatée des pièces

PIER-TRC

IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.

ITEM /

 

 

 

 

 

COMMON PART / PIÉCES COMMUNES

SERIAL #

PART NUMBER

P IÈCE

 

 

 

 

 

/ N° DE SÉRIE

/ N° DE PIÈCE

 

 

 

 

 

 

 

 

 

 

 

ON/OFF Rocker Switch / Interrupteur à bascule marche/arrêt

 

060

-511

1

Burner Orifice NG (#32DMS) / Orifice de brûleur GN (#32DMS)

 

573

-800

1

Burner Orifice LP (1.8mm) /

Orifice de brûleur PL (#1.8mm)

 

501

-801

2

End Glass Assembly

 

 

 

 

GLA-PTRC-E

3

Glass Door Assembly

NG /

Porte en verre

GN

PRE 8865

GLA-PTRC

POST 8865

GLA-PIER

 

 

 

 

 

 

 

 

 

 

 

3

Glass Door Assembly

LP/

Porte en verre

PL

PRE 2301

GLA-PTRC

POST 2301

GLA-PIER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRE 16919

SRV501-176A

4

Burner Assembly NG

/ Brûleur GN

 

16919 to 18287

501

-173A

 

 

 

 

 

 

 

 

 

 

 

POST 18288

501

-272A

 

 

 

 

 

 

 

 

 

 

 

PRE 3666

SRV501-175A

4

Burner Assembly LP

/

Brûleur PL

 

3666 to 3984

501

-172A

 

 

 

 

 

 

 

 

 

 

 

POST 3985

501

-273A

5

Log Grate

/

Grille de Bûche

 

 

501

-364

6

Base Refractory

/

Réfractaire Base

 

 

SRV504-738-UM

7

Refractory, Rear

/

Réfractaire

 

 

SRV504-737-UM

 

NG Log Set

Assembly (sold as complete log set only) / GN Jeu de Bûches

PRE18287

LOGS-PTRC

8

POST 18288

LOGS-MS

 

 

 

 

 

 

 

 

 

 

LP Log Set

Assembly (sold as complete log set only) / PL Jeu de Bûches

PRE 3984

LOGS-PTRC

 

 

POST 3985

LOGS-MS

 

 

 

 

 

 

 

 

 

 

 

9

Decorative Front

/

Avant décoratif

 

 

DF-36H

10

Flex Ball Valve Assembly /

Fléchir l'Assemblée de Soupape de Balle

 

302

-320A

12

3/8" Burner Tube

/

Tube de brûleur

 

 

570

-301A

13

Decorative Front

(End) / Le Devant décoratif (la Fin)

 

DF-PTRCE

14

Extrusion with holes

/ L'extrusion avec les trous

 

464

-343

15

Surround Right

/

Entourage droit

 

 

501

-233

16

Surround Left

/

Entourage gauche

 

 

501

-232

 

Glass C lip

/ Trombone de verre

 

 

501

-235

 

STANDING PILOT IGNITION ONLY / ALLUMAGE UNE VEILLEUSE SEULEMENT

 

 

 

Piezo Ignitor

/

Allumage Piézo

 

 

418

-513

 

Junction Box

/

Boîtier de raccordement

 

 

100-250A

 

Valve NG

/

Valve GN

 

 

 

060

-522

 

Valve LP

/

Valve PL

 

 

 

 

060

-523

11

Pilot Assembly NG

/

Module de veilleuse GN

 

485

-510A

11

Pilot Assembly LP /

Module de veilleuse PL

 

485

-511A

 

Pilot Orifice NG

/

Orifice de veilleuse GN

 

 

446

-505

 

Pilot Orifice LP

/

Orifice de veilleuse PL

 

 

446

-517

 

Thermocouple

/ Thermocouple

 

 

446

-511

 

Thermopile

/

Thermopile

 

 

 

060

-512

 

Pilot Tube

/

Tube de veilleuse

 

 

SRV485-301

 

DSI IGNITION ONLY / ALLUMAGE DSI SEULEMENT

 

 

 

 

Junction Box

/

Boîtier de raccordement

 

 

100-254A

 

Valve NG

/

Valve GN

 

 

 

492

-500

 

Valve LP

/

Valve PL

 

 

 

 

492

-501

 

Electrode

/

Électrode

 

 

 

501

-591

 

Module /

Module

 

 

 

 

 

 

501

-592

 

IPI IGNITION ONLY / ALLUMAGE IPI SEULEMENT

 

 

 

 

Junction Box

/

Boîtier de raccordement

 

 

383

-250A

 

Valve NG

/

Valve GN

 

 

 

750

-500

 

Valve LP

/

Valve PL

 

 

 

 

750

-501

11

Pilot Assembly NG

/

Module de veilleuse GN

 

385

-510A

11

Pilot Assembly LP /

Module de veilleuse PL

 

385

-511A

 

Wire Assembly

/ Module de fil

 

 

593

-590A

 

Module / Module

 

 

 

 

 

 

593

-592

 

3V Plug

 

 

 

 

 

 

 

 

 

 

593

-593A

 

Conversion Kit NG

/

Module de conversion GN

 

NGK-MS-IPI

 

Conversion Kit LP

/

Module de conversion PL

 

LPK-MS-IPI

 

Pilot Tube

/

Tube de veilleuse

 

 

SRV485-301

 

Battery Pack

/

Paquet de Batterie(Pile)

 

 

593

-594A

ACCESSORIES / ACCESSOIRES

 

 

 

 

 

Fan Kit /

Module de ventilateur

 

 

GFK-160A

 

Remote Control Kit

/

Commande à distance

 

RC-SMART-HNG

 

Remote Control Kit

/

Commande à distance

 

SMART-STAT-HNG

 

Conversion Kit NG / Module de conversion GN

PRE 18287

NGK-PTRD

 

POST 18288

NGK-PTRCMS

 

 

 

 

 

 

 

 

 

 

 

NGK-PTRCMS-DSI

 

 

 

 

 

 

 

 

 

 

 

 

 

Conversion Kit LP

/

Module de conversion PL

PRE 3984

LPK-PTRD

 

POST 3985

LPK-PTRCMS

 

 

 

 

 

 

 

 

 

 

 

LPK-PTRCMS-DSI

 

 

 

 

 

 

 

 

 

 

 

 

5

Service Parts

ST-TRC

(NG, LP) Exploded Parts Diagram

Beginning Manufacturing Date: 6-97

(GN, PL) Vue éclatée des pièces

Ending Manufacturing Date: ______

2

7

8

10 9

STANDING PILOT

4

6

11 1

2

5

3

12 Log Assembly

7

* Part number list on following page.

* La liste des numéros de pièce se trouve à la page suivante.

6

(NG, LP) Exploded Parts Diagram / Vue éclatée des pièces

ST-TRC

IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.

ITEM /

 

 

 

 

 

 

 

COMMON PARTS / I PIÉCES COMMUNES

 

SERIAL #

PART NUMBER

PIÈCE

 

 

 

 

 

 

 

/ N° DE SÉRIE

/ N° DE PIÈCE

 

 

 

 

 

 

 

 

 

 

 

 

ON/OFF Rocker Switch

/

Interrupteur à bascule marche/arrêt

 

 

060-511

1

Burner Orifice NG (#32DMS)

/ Orifice de brûleur GN (#32DMS)

 

 

573-800

1

Burner Orifice LP (1.8mm) /

Orifice de brûleur PL (1.8mm)

 

 

501-801

2

Glass Door Assembly

NG /

Porte en verre GN

 

PRE

8558

GLA-PTRC

 

POST 8558

GLA-PIER

 

 

 

 

 

 

 

 

 

 

 

 

2

Glass Door Assembly

LP /

Porte en verre PL

 

PRE

2254

GLA-PTRC

 

POST 2254

GLA-PIER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRE 16067

SRV501-176A

3

Burner Assembly NG

/ Brûleur GN

 

16067 to 18029

501-173A

 

 

 

 

 

 

 

 

 

 

 

 

POST 18030

501-272A

 

 

 

 

 

 

 

 

 

 

 

 

PRE 3608

SRV501-175A

3

Burner Assembly LP

/ Brûleur PL

 

3608 to 3994

501-172A

 

 

 

 

 

 

 

 

 

 

 

 

POST 3995

501-273A

4

Log Grate

/

Grille de Bûche

 

 

 

 

501-364

5

Base Refractory

 

/

Réfractaire Base

 

 

 

SRV504-738-UM

6

Refractory, Rear

 

/

Réfractaire

 

 

 

SRV504-737-UM

7

Decorative Front

/

Avant décoratif

 

 

 

DF-36H

8

Surround Side / Entourage gauche

 

 

 

502-202

9

Flex Ball Valve Assembly /

Fléchir l'Assemblée de Soupape de Balle

 

 

302-320A

11

3/8" Burner Tube

/

Tube de brûleur

 

 

 

570-301A

 

NG Log Set

Assembly

(sold as complete log set only) /

GN Jeu de Bûches

PRE18029

LOGS-PTRC

12

POST 18030

LOGS-MS

 

 

 

 

 

 

 

 

 

 

 

LP Log Set

Assembly

(sold as complete log set only) /

PL Jeu de Bûches

PRE 3994

LOGS-PTRC

 

 

POST 3995

LOGS-MS

 

 

 

 

 

 

 

 

 

 

 

 

 

Glass Clips

/ Trombone de verre

 

 

 

501-135

 

STANDING PILOT IGNITION ONLY / ALLUMAGE UNE VEILLEUSE SEULEMENT

 

 

 

 

Piezo Ignitor

/

Allumage Piézo

 

 

 

418-513

 

Junction Box

/

Boîtier de raccordement

 

 

 

100-250A

 

Valve NG

/

Valve GN

 

 

 

 

 

 

060-522

 

Valve LP

/

Valve PL

 

 

 

 

 

 

060-523

 

Pilot Assembly NG

/

Module de veilleuse GN

 

 

 

485-510A

10

Pilot Assembly LP /

Module de veilleuse PL

 

 

 

485-511A

10

Pilot Orifice NG

/

Orifice de veilleuse GN

 

 

 

446-505

 

Pilot Orifice LP

/

Orifice de veilleuse PL

 

 

 

446-517

 

Thermocouple

/

Thermocouple

 

 

 

446-511

 

Thermopile

/

Thermopile

 

 

 

 

060-512

 

Pilot Tube

/

Tube de veilleuse

 

 

 

SRV485-301

 

DSI IGNITION ONLY / ALLUMAGE DSI SEULEMENT

 

 

 

 

 

Junction Box

/

Boîtier de raccordement

 

 

 

100-254A

 

Valve NG

/

Valve GN

 

 

 

 

 

 

492-500

 

Valve LP

/

Valve PL

 

 

 

 

 

 

492-501

 

Electrode

/

Électrode

 

 

 

 

 

501-591

 

Module /

Module

 

 

 

 

 

 

 

 

501-592

 

IPI IGNITION ONLY / ALLUMAGE IPI SEULEMENT

 

 

 

 

 

Junction Box

/

Boîtier de raccordement

 

 

 

383-250A

 

Valve NG

/

Valve GN

 

 

 

 

 

 

750-500

 

Valve LP

/

Valve PL

 

 

 

 

 

 

750-501

10

Pilot Assembly NG

/

Module de veilleuse GN

 

 

 

385-510A

10

Pilot Assembly LP /

Module de veilleuse PL

 

 

 

385-511A

 

Wire Assembly

/ Module de fil

 

 

 

593-590A

 

Module / Module

 

 

 

 

 

 

 

 

593-592

 

3V Plug

 

 

 

 

 

 

 

 

 

 

 

 

593-593A

 

Conversion Kit NG / Module de conversion GN

 

 

 

NGK-MS-IPI

 

Conversion Kit LP

/

Module de conversion PL

 

 

 

LPK-MS-IPI

 

Pilot Tube

/

Tube de veilleuse

 

 

 

SRV485-301

 

Battery Pack

/

Paquet de Batterie(Pile)

 

 

 

593-594A

ACCESSORIES / ACCESSOIRES

 

 

 

 

 

Fan Kit /

Module de ventilateur

 

 

 

GFK-160A

 

Remote Control Kit

/

Commande à distance

 

 

 

RC-SMART-HNG

 

Remote Control Kit

/

Commande à distance

 

 

 

SMART-STAT-HNG

 

 

 

 

 

 

 

 

 

 

 

 

PRE 18029

NGK-PTRD

 

Conversion Kit NG / Module de conversion GN

 

POST 18030

NGK-PTRCMS

 

 

 

 

 

 

 

 

 

 

 

 

NGK-PTRCMS-DSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRE 3994

LPK-PTRD

 

Conversion Kit LP / Module de conversion PL

 

POST 3995

LPK-PTRCMS

 

 

 

 

 

 

 

 

 

 

 

 

LPK-PTRCMS-DSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

Service Parts

L-Corner-TRC

(NG, LP) Exploded Parts Diagram

Beginning Manufacturing Date: 6-97

(GN, PL) Vue éclatée des pièces

Ending Manufacturing Date: ______

10

STANDING PILOT 1

12 8

11

7

 

5

 

2

 

15

14

6

4

9 Log Assembly

3

 

13

15

* Part number list on following page.

* La liste des numéros de pièce se trouve à la page suivante.

8

(NG, LP) Exploded Parts Diagram / Vue éclatée des pièces

L-CORNER-TRC

IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.

ITEM /

 

 

 

 

 

 

 

COMMON PARTS / PIÉCES COMMUNES

 

SERIAL #

PART NUMBER

PIÈCE

 

 

 

 

 

 

 

/ N° DE SÉRIE

/ N° DE PIÈCE

 

 

 

 

 

 

 

 

 

 

 

 

ON/OFF Rocker Switch

/

Interrupteur à bascule marche/arrêt

 

 

060-511

1

Burner Orifice NG (#32DMS) / Orifice de brûleur GN (#32DMS)

 

 

573-800

1

Burner Orifice LP (1.8mm) /

Orifice de brûleur PL (1.8mm)

 

 

501-801

2

Glass Door Assembly, End /

Porte en verre

 

 

 

GLA-PTRC-E

3

Glass Door Assembly NG /

Porte en verre GN

 

PRE

1957

GLA-PTRC

 

POST 1957

GLA-PIER

 

 

 

 

 

 

 

 

 

 

 

 

3

Glass Door Assembly LP/ Porte en verre PL

 

PRE

1232

GLA-PTRC

 

POST 1232

GLA-PIER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRE

2920

SRV501-176A

4

Burner Assembly NG

/ Brûleur GN

 

2920 to 3102

501-173A

 

 

 

 

 

 

 

 

 

 

 

 

POST

3103

501-272A

 

 

 

 

 

 

 

 

 

 

 

 

PRE

1439

SRV501-175A

4

Burner Assembly LP

/ Brûleur PL

 

1439 to 1473

501-172A

 

 

 

 

 

 

 

 

 

 

 

 

POST

1474

501-273A

5

Log Grate

/

Grille de Bûche

 

 

 

501-364

6

Base Refractory

 

/

Réfractaire Base

 

 

 

SRV504-738-UM

7

Refractory, Rear

/

Réfractaire

 

 

 

SRV504-737-UM

8

Refractory, Back / Réfractaire

 

 

 

SRV504-736-UM

 

NG Log Set

Assembly

(sold as complete log set only)

/ GN Jeu de Bûches

PRE 3102

LOGS-PTRC

9

POST 3103

LOGS-MS

 

 

 

 

 

 

 

 

 

 

 

LP Log Set

Assembly

(sold as complete log set only)

/ GN Jeu de Bûches

PRE 1473

LOGS-PTRC

 

 

POST 1473

LOGS-MS

 

 

 

 

 

 

 

 

 

 

 

 

10

Surround Side Left /

 

Entourer le Côté Part

 

 

 

501-232

11

3/8" Burner Tube

/

Tube de brûleur

 

 

 

570-301A

13

Decorative Front

/

Avant décoratif

 

 

 

DF-36H

14

Decorative Front End

/

La Fin décorative de Devant

 

 

 

DF-PTRCE

15

Extrusion with holes

/ L'extrusion avec les trous

 

 

 

464-343

 

Glass Clip

/ Trombone de verre

 

 

 

501-135

 

Flex Ball Valve Assembly /

Fléchir l'Assemblée de Soupape de Balle

 

 

302-320A

 

STANDING PILOT IGNITION ONLY / ALLUMAGE UNE VEILLEUSE SEULEMENT

 

 

 

 

Piezo Ignitor

/

Allumage Piézo

 

 

 

418-513

 

Junction Box

/

Boîtier de raccordement

 

 

 

100-250A

 

Valve NG

/

Valve GN

 

 

 

 

 

060-522

 

Valve LP

/

Valve PL

 

 

 

 

 

 

060-523

12

Pilot Assembly NG

/

Module de veilleuse GN

 

 

 

485-510A

12

Pilot Assembly LP /

Module de veilleuse PL

 

 

 

485-511A

 

Pilot Orifice NG

/

Orifice de veilleuse GN

 

 

 

446-505

 

Pilot Orifice LP

/

Orifice de veilleuse PL

 

 

 

446-517

 

Thermocouple

/ Thermocouple

 

 

 

446-511

 

Thermopile

/

Thermopile

 

 

 

 

060-512

 

Pilot Tube

/

Tube de veilleuse

 

 

 

SRV485-301

 

DSI IGNITION ONLY / ALLUMAGE DSI SEULEMENT

 

 

 

 

 

Junction Box

/

Boîtier de raccordement

 

 

 

100-254A

 

Valve NG

/

Valve GN

 

 

 

 

 

492-500

 

Valve LP

/

Valve PL

 

 

 

 

 

 

492-501

 

Electrode

/

Électrode

 

 

 

 

 

501-591

 

Module /

Module

 

 

 

 

 

 

 

 

501-592

 

IPI IGNITION ONLY / ALLUMAGE IPI SEULEMENT

 

 

 

 

 

Junction Box

/

Boîtier de raccordement

 

 

 

383-250A

 

Valve NG

/

Valve GN

 

 

 

 

 

750-500

 

Valve LP

/

Valve PL

 

 

 

 

 

 

750-501

12

Pilot Assembly NG

/

Module de veilleuse GN

 

 

 

385-510A

12

Pilot Assembly LP /

Module de veilleuse PL

 

 

 

385-511A

 

Wire Assembly

/ Module de fil

 

 

 

593-590A

 

Module / Module

 

 

 

 

 

 

 

 

593-592

 

3V Plug

 

 

 

 

 

 

 

 

 

 

 

 

593-593A

 

Conversion Kit NG / Module de conversion GN

 

 

 

NGK-MS-IPI

 

Conversion Kit LP

/

Module de conversion PL

 

 

 

LPK-MS-IPI

 

Pilot Tube

/

Tube de veilleuse

 

 

 

SRV485-301

 

Battery Pack

/

Paquet de Batterie(Pile)

 

 

 

593-594A

ACCESSORIES / ACCESSOIRES

 

 

 

 

 

Fan Kit /

Module de ventilateur

 

 

 

GFK-160A

 

Remote Control Kit

/

Commande à distance

 

 

 

RC-SMART-HNG

 

Remote Control Kit

/

Commande à distance

 

 

 

SMART-STAT-HNG

 

Conversion Kit NG

/

Module de conversion GN

 

PRE 3102

NGK-PTRD

 

 

POST 3103

NGK-PTRCMS

 

 

 

 

 

 

 

 

 

 

 

 

 

Conversion Kit LP

/

Module de conversion PL

 

PRE 1472

LPK-PTRD

 

 

POST 1473

LPK-PTRCMS

 

 

 

 

 

 

 

 

 

 

 

 

9

Hearth and Home Technologies R-CORNER-TRC, PIER-TRC, L-CORNER-TRC, ST-TRC User Manual

Service Parts

R-Corner-TRC

(NG, LP) Exploded Parts Diagram

Beginning Manufacturing Date: 6-97

(GN, PL) Vue éclatée des pièces

Ending Manufacturing Date: ______

11

13

10

1

12

STANDING PILOT

7

16

8

2

5

15

6

14

3

4

9 Log Assembly

*Part number list on following page.

*La liste des numéros de pièce se trouve

àla page suivante.

10

(NG, LP) Exploded Parts Diagram / Vue éclatée des pièces

R-CORNER-TRC

IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering, supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'est valide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'une commande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.

ITEM /

 

 

 

 

 

 

 

COMMON PARTS / PIÉCES COMMUNES

 

SERIAL # /

 

PART NUMBER

P IÈCE

 

 

 

 

 

 

 

 

N° DE SÉRIE

 

/ N° DE PIÈCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON/OFF Rocker Switch

/

 

Interrupteur à bascule marche/arrêt

 

 

060-511

1

Burner Orifice NG (#32DMS)

/ Orifice de brûleur GN (#32DMS)

 

 

573

-800

1

Burner Orifice LP (1.8mm) /

Orifice de brûleur PL (1.8mm)

 

 

501

-801

2

Glass Door Assembly, End /

Porte en verre

 

 

 

GLA-PTRC-E

3

Glass Door Assembly

NG /

Porte en verre

GN

PRE

2132

GLA-PTRC

POST 2132

GLA-PIER

 

 

 

 

 

 

 

 

 

 

 

 

 

3

Glass Door Assembly

NG /

Porte en verre

GN

PRE

1240

GLA-PTRC

POST 1240

GLA-PIER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRE

3178

SRV501-176A

4

Burner Assembly NG

/ Brûleur GN

 

3178 to 3355

501

-173A

 

 

 

 

 

 

 

 

 

 

 

 

 

POST 3356

501-272A

 

 

 

 

 

 

 

 

 

 

 

 

 

PRE

1427

SRV501-175A

4

Burner Assembly LP

/

Brûleur PL

 

1427 to 1478

501

-172A

 

 

 

 

 

 

 

 

 

 

 

 

 

POST 1479

501-273A

5

Log Grate

/

Grille de Bûche

 

 

 

 

501

-364

6

Base Refractory

/

Réfractaire Base

 

 

 

SRV504-738-UM

7

Refractory, Rear

/

Réfractaire

 

 

 

SRV504-737-UM

8

Refractory, Back /

Réfractaire

 

 

 

SRV504-736-UM

 

NG Log Set

Assembly

/ GN Jeu de Bûches

 

PRE 3355

LOGS-PTRC

9

 

POST 3356

LOGS-MS

 

 

 

 

 

 

 

 

 

 

 

 

LP Log Set

Assembly

/

PL Jeu de Bûches

 

PRE 1478

LOGS-PTRC

 

 

 

 

POST 1479

LOGS-MS

 

 

 

 

 

 

 

 

 

 

 

 

 

10

Flex Ball Valve Assembly

/ Fléchir l'Assemblée de Soupape de Balle

 

 

320

-320A

12

3/8" Burner Tube

/

Tube de brûleur

 

 

 

570

-301A

13

Surround Right

/

Entourage droit

 

 

 

501

-232

14

Decorative Front End

/

La Fin décorative de Devant

 

 

DF-PTRC E

15

Extrusion with holes

/ L'extrusion avec les trous

 

 

464

-343

16

Decorative Front

/

Avant décoratif

 

 

 

DF-36H

 

Glass C lips

/ Trombone de verre

 

 

 

501

-135

 

STANDING PILOT IGNITION ONLY

 

 

 

 

 

 

Piezo Ignitor

/

Allumage Piézo

 

 

 

418

-513

 

Junction Box

/

Boîtier de raccordement

 

 

 

100-250A

 

Valve NG

/

Valve GN

 

 

 

 

 

 

 

060

-522

 

Valve LP

/

Valve PL

 

 

 

 

 

 

 

060

-523

11

Pilot Assembly NG

/

Module de veilleuse GN

 

 

485

-510A

11

Pilot Assembly LP /

Module de veilleuse PL

 

 

 

485-511A

 

Pilot Orifice NG

/

Orifice de veilleuse GN

 

 

 

446

-505

 

Pilot Orifice LP

/

Orifice de veilleuse PL

 

 

 

446

-517

 

Thermocouple

/

Thermocouple

 

 

 

446-511

 

Thermopile

/

Thermopile

 

 

 

 

060

-512

 

Pilot Tube

/

Tube de veilleuse

 

 

 

SRV485-301

DSI IGNITION ONLY / ALLUMAGE DSI SEULEMENT

 

 

 

 

 

Junction Box

/

Boîtier de raccordement

 

 

 

100-254A

 

Valve NG

/

Valve GN

 

 

 

 

 

 

 

492

-500

 

Valve LP

/

Valve PL

 

 

 

 

 

 

 

492

-501

 

Electrode

/

Électrode

 

 

 

 

 

 

 

501

-591

 

Module /

Module

 

 

 

 

 

 

 

 

 

501

-592

 

IPI IGNITION ONLY / ALLUMAGE IPI SEULEMENT

 

 

 

 

 

Junction Box

/

Boîtier de raccordement

 

 

 

383

-250A

 

Valve NG

/

Valve GN

 

 

 

 

 

 

 

750

-500

 

Valve LP

/

Valve PL

 

 

 

 

 

 

 

750

-501

11

Pilot Assembly NG

/

Module de veilleuse GN

 

 

385

-510A

11

Pilot Assembly LP /

Module de veilleuse PL

 

 

 

385-511A

 

Wire Assembly

/ Module de fil

 

 

 

593

-590A

 

Module / Module

 

 

 

 

 

 

 

 

 

593

-592

 

3V Plug

 

 

 

 

 

 

 

 

 

 

 

 

 

593

-593A

 

Conversion Kit NG

/

Module de conversion GN

 

 

 

NGK-MS-IPI

 

Conversion Kit LP

/

Module de conversion PL

 

 

 

LPK-MS-IPI

 

Pilot Tube

/

Tube de veilleuse

 

 

 

SRV485-301

 

Battery Pack

/

Paquet de Batterie(Pile)

 

 

 

593

-394A

ACCESSORIES / ACCESSOIRES

 

 

 

 

 

 

Fan Kit /

Module de ventilateur

 

 

 

GFK-160A

 

Remote Control Kit

/

Commande à distance

 

 

RC-SMART-HNG

 

Remote Control Kit

/

Commande à distance

 

 

SMART-STAT-HNG

 

Conversion Kit NG / Module de conversion GN

 

PRE

3355

NGK-PTRD

 

 

POST 3356

NGK-PTRCMS

 

 

 

 

 

 

 

 

 

 

 

 

 

NGK-PTRCMS-DSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Conversion Kit LP

/

Module de conversion PL

 

PRE

1478

LPK-PTRD

 

 

POST 1479

LPK-PTRCMS

 

 

 

 

 

 

 

 

 

 

 

 

 

LPK-PTRCMS-DSI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

Approvals and

Codes

Appliance Certification

The Heat-N-Glo fireplace models discussed in this Installers Guide have been tested to certification standards and listed by the applicable laboratories.

Certification

MODELS: PIER-TRC, ST-TRC, L-CORNER-TRC, R-CORNER-TRC

LABORATORY: Underwriters Laboratories TYPE: Direct Vent Gas Fireplace STANDARD: ANSI Z21.50•CGA2.22•UL307B

Installation Codes

The fireplace installation must conform to local codes. Before installing the fireplace, consult the local building code agency to ensure that you are in compliance with all applicable codes, including permits and inspections.

In the absence of local codes, the fireplace installation must conform to the National Fuel Gas Code ANSI Z223.1 (in the United States) or the CAN/CGA-B149 Installation Codes (in Canada). The appliance must be electrically grounded in accordance with local codes or, in the absence of local codes with the National Electric Code ANSI/NFPA No. 70 (in the United States), or to the CSA C22.1 Canadian Electric Code (in Canada).

These models may be installed in a bedroom or bed-sitting room in the U.S.A. and Canada.

Heat-N-Glo Quality Systems registered by SGS ICS

High Altitude Installations

U.L. Listed gas appliances are tested and approved without requiring changes for elevations from 0 to 2,000 feet in the U. S. A. and in Canada.

When installing this appliance at an elevation above 2,000 feet, it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Input rate should be reduced by 4% for each 1000 feet above a 2000 foot elevation in the U.S.A. or 10% for elevations between 2000 and 4500 feet in Canada. If the heating value of the gas has been reduced, these rules do not apply. To identify the proper orifice size, check with the local gas utility.

If installing this appliance at an elevation above 4,500 feet (in Canada), check with local authorities.

12

Loading...