Hearth and Home Technologies E42, E39, E36 User Manual

0 (0)

INSTALLATION & OPERATING

INSTRUCTIONS

E36 E39 E42

WOODBURNING FIREPLACE

Note: An arrow ( ) found in the text signifies change in content.

WARNING!

Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult a qualified installer, service agency or the gas supplier.

08/04

17335 Rev L

1

E36/39/42 INSTALLATION INSTRUCTIONS

 

Table of Contents

 

 

Design and Installation Considerations...........................................................................................

3

A. Listings and CodeApprovals ..........................................................................................................

4

B. Description of the Fireplace System ..............................................................................................

4

C. Fireplace System Components ......................................................................................................

5

D.

Pre-Installation Preparation ..........................................................................................................

10

E.

Chimney Requirements................................................................................................................

12

F.

Installation of Fireplace ................................................................................................................

15

G.

Constructing a Chase ..................................................................................................................

22

H.

Operating Instructions..................................................................................................................

25

I.

Maintenance Instructions .............................................................................................................

29

 

Index ...........................................................................................................................................

31

 

Warranty ......................................................................................................................................

32

CAUTION:

Do not expose the fireplace to the elements (i.e. rain, etc.) and keep the fireplace dry at all times. Wet insulation will produce an odor when the fireplace is used.

WARNING!

This fireplace is tested and listed for use only with the optional accessories listed in these instructions. Use of optional accessories not specifically tested for this appliance could void the warranty and/or result in a safety hazard.

Safety Precautions

1.Please read these installation instructions completely before beginning installation procedures. Failure to follow them could cause a fireplace malfunction resulting in serious injury and/or property damage.

2.Always check your local building codes prior to installation. The installation must comply with all local, regional, state and national codes and regulations.

3.An adequate supply of replacement combustion air from outside the house must be available to the fire for the fireplace to operate properly. To achieve this, the use of the optional outside air kit is highly recommended.

In the event the home is unusually tightly sealed, the optional combustion air kit may not provide all the air required to support combustion. Hearth & Home Technologies is not responsible for any smoking or related problems that may result from the lack of adequate combustion air. It is the responsibility of the builder/contractor to ensure that adequate combustion air has been provided for the fireplace.

4.The fireplace must be installed with the Hearth & Home Technologies SL Series Chimney System.

The chimney system must always terminate outside the building. Be sure to follow all chimney specifications given in these installation instructions.

5.NEVER leave children unattended when there is a fire burning in the fireplace.

6.This fireplace is built for solid fuel only. NEVER use gasoline, gasoline type lantern fuel, kerosene, charcoal light fluid, or similar liquids in this fireplace. Keep any flammable liquids a safe distance from the fireplace.

7.DO NOT use chimney cleaners or flame colorants in your fireplace.

8.The flue damper must be open at all times when the fireplace is in use.

9.While servicing this fireplace, always shut off any electricity or gas to the fireplace. This will prevent possible electric shock or burns. Also, make sure the fireplace is completely cooled before servicing.

10.To ensure a safe fireplace system and to prevent the build up of soot and creosote, inspect and clean the fireplace and chimney prior to use and periodically during the burning season. See “Maintenance Instructions” in this manual for cleaning instructions.

2

17335 Rev L

07/04

E36/39/42 INSTALLATION INSTRUCTIONS

DESIGN AND INSTALLATION CONSIDERATIONS

When selecting a location for your woodburning fireplace, it is important to evaluate a number of considerations. Modern construction techniques can create conditions that may not allow your chimney to draft properly. This may result in smoke spillage from your fireplace, as well as cause other combustion appliances to operate incorrectly.

Tightly sealed construction is important for energy efficiency. Unfortunately, a great deal of effort has been directed to tightening up sidewall construction, while considerably less attention has been paid to tightening upper portions of the warm air envelope (insulated ceilings). This has increased the “Stack Effect”, a condition that increases the negative pressure generated by the structure. This negative pressure will directly affect the drafting performance of a fireplace chimney. To minimize the negative pressure generated by stack effect, make certain that all duct work installed in the attic spaces is sealed airtight. Minimize the number of recessed light fixtures installed in the insulated ceiling, and use sealed recessed light fixtures. Finally, make certain the whole house fans and attic access panels are tightly sealed. These are important design considerations that must be observed during the design and construction stage of the home.

If you desire to put a fireplace in your basement, we recommend that you consider a direct vent gas fireplace. Basements always have a significant negative air pressure that causes the fireplace system to be more susceptible to smoke spillage and cold flue back drafting. Since direct vent gas fireplaces are sealed, they are not affected by the negative pressure that exists in basements.

Finally, woodburning fireplaces perform best when their chimney (roof termination) is located on the upper half of the roof, especially when cathedral ceilings are present. Chimneys that are located on the lower half of the roof realize what is known as “lazy flue” and will not draft as well as a chimney that is located in the upper portion of the roof. The reason for this is that the stack effect generated by the overall height of the living spaces inside the house will exceed the draft generated by the chimney system. If you desire to place a woodburning fireplace in a location where the termination cap would be located on the lower half of a roof, such as on an outside wall at the base of a cathedral ceiling, we recommend that you consider using a direct vent gas fireplace. This will assure the homeowner a fireplace that operates correctly.

These properties do not affect just your woodburning factory built fireplace. They can cause any woodburning fireplace as well as any conventionally vented (B-vent) gas appliance to operate improperly. Careful planning at this stage of your project will ensure satisfaction with the operation of your fireplace once it is completed.

08/04

17335 Rev L

3

E36/39/42 INSTALLATION INSTRUCTIONS

A. LISTINGS AND CODE APPROVALS

This fireplace system has been tested and listed in accordance with UL 127 and ULC-S610 standards, and has been listed by Underwriters Laboratories Inc. for installation and operation in the United States and Canada as described in this manual.

This fireplace has been tested and listed for use with the optional components listed on page 5. These optional components may be purchased separately and installed at a later date. However, installation of an outside air kit will require significant reconstruction, and should be installed at the time of the initial fireplace installation.

Check with your local building code agency prior to installing this fireplace to ensure compliance with local codes, including the need for permits and follow-up inspections. If you need assistance during installation, please contact your local dealer or the Heatilator Technical Services Department, Hearth & Home Technologies Inc., 1915 W. Saunders St., Mt. Pleasant, Iowa 52641 (1-800-927-6841).

Heatilator® is a registered trademark of Hearth & Home Technologies Inc.

WARNING!

This fireplace and its components are designed to be installed and operated as a system. Any alteration to or substitution for items in this system, unless allowed by these installation instructions, will void the Underwriters Laboratories listing and may void the product warranty. It may also create a hazardous installation. Read through these instructions thoroughly before starting your installation and follow them carefully throughout your project.

B.DESCRIPTION OF THE FIREPLACE SYSTEM

1.The Heatilator fireplace system consists of the following:

a.Fireplace/Integral Grate

b.Refractory

c.Chimney Termination Cap

d.Chimney System

e.Hearth Extension

2.Optional Components Include:

a.Glass Doors

b.Chimney Air Kit

c.Outside Combustion Air System

Note: Illustrations used throughout these instructions reflect “typical installations” and are for design purposes only. Actual installation may vary slightly due to individual design preferences. However, minimum and maximum clearances must be maintained at all times.

The illustrations and diagrams used throughout these installation instructions are not drawn to scale.

Figure 1 - Typical Fireplace System

4

17335 Rev L

07/04

E36/39/42 INSTALLATION INSTRUCTIONS

C.SYSTEM COMPONENTS

1.Fireplace Components

 

Catalog #

 

Description:

 

 

 

 

E36

E39

E42

Fireplace, includes integral grate and hearth protection strips

HX3

HX3

HX4

Hearth Extension

 

 

 

 

DM1036

DM1039

DM1042

Original Bifold Glass Doors - Black Finish

 

 

 

 

DM1036B

DM1039B

DM1042B

Original Bifold Glass Doors - Polished Brass Finish

 

 

 

 

DM1036S

DM1039S

DM1042S

Original Bifold Glass Doors - Stainless Steel Finish

DP1036

none

DP1042

Perception Glass Doors - Black Finish

DP1036B

none

DP1042B

Perception Glass Doors - Polished Brass Finish

DP1036S

none

DP1042S

Perception Glass Doors - Stainless Steel Finish

DMA1036B

none

DMA1042B

Arched Cabinet Style Glass Doors - Polished Brass Finish

GR4

GR5

GR6

Integral Grate (included with fireplace)

 

 

 

 

 

AK14

 

Outside Air Kit

 

 

 

 

GLASS DOORS

DM1036

DM1036B

DM1036S

DMA1036B

DP1036

DP1036B

DP1036S

DM1039

DM1039B

DM1039S

DMA1042B

DP1042

DP1042B

DP1042S

DM1042

DM1042B

DM1042S

Arched Cabinet Glass Doors

Perception Glass Doors

Bifold Glass Doors

INTEGRAL GRATE

HEARTH EXTENSION

 

(Supplied)

 

 

 

A

B

 

 

GR4

GR5

Cat #

A

B

GR6

 

 

 

HX3

52 in.

16 in.

 

 

 

 

 

 

HX4

66 in.

20 in.

 

 

 

 

08/04

17335 Rev L

5

E36/39/42 INSTALLATION INSTRUCTIONS

Cat #

A

B

C

D

 

 

 

 

 

E/EC36

36 in.

41 in.

25-1/4 in.

12-5/8 in.

914 mm

1041 mm

641 mm

321 mm

 

 

 

 

 

 

E/EC39

39 in

44 in.

28-1/4 in.

14-1/8 in.

991 mm

1118 mm

718 mm

359 mm

 

 

 

 

 

 

E/EC42

42 in.

47 in.

31-1/4 in.

15-5/8 in.

1067 mm

1194 mm

794 mm

397 mm

 

 

 

 

 

 

Fireplace Dimensions

OUTSIDE AIR KIT

AK14

6

17335 Rev L

07/04

E36/39/42 INSTALLATION INSTRUCTIONS

2. Chimney Components

The following pictures show only those chimney components which may be safely used with this fireplace.

Catalog #

Description:

 

 

CAK4A

Chimney Air Kit

 

 

ID4

Insulated Duct/Outside Air

 

 

UD4

Uninsulated Duct/Outside Air

 

 

SL306

Chimney Section - 6 in. long

 

 

SL312

Chimney Section - 12 in. long

 

 

SL318

Chimney Section - 18 in. long

 

 

SL324

Chimney Section - 24 in. long

 

 

SL336

Chimney Section - 36 in. long

 

 

SL348

Chimney Section - 48 in. long

 

 

SL3

Chimney Stabilizer

 

 

SL315

Chimney Offset/Return - 15-degree

 

 

SL330

Chimney Offset/Return - 30-degree

 

 

FS338

Firestop - Straight

 

 

FS339

Firestop - 15-degree

 

 

FS340

Firestop - 30-degree

 

 

AS8

SL300 Straight Attic Insulation Shield, 24 in.

 

 

JB877

Chimney Joint Band

 

 

CB876

Chimney Bracket

 

 

RF370

Roof Flashing - Flat to 6/12 Pitch

 

 

RF371

Roof Flashing - 6/12 to 12/12 Pitch

 

 

TR344

Round Termination Cap

 

 

TR342

Round Telescoping Termination Cap

 

 

ST375

Square Termination Cap

 

 

TS345

Square Termination Cap

 

 

TS345P

Square Termination Cap - Painted

 

 

TCT375

Terra Cotta Termination Cap

 

 

CT35

Chase Top

 

 

LDS33

Decorative Shroud - 3 ft x 3 ft

 

 

LDS46

Decorative Shroud - 4 ft x 6 ft

 

 

08/04

17335 Rev L

7

E36/39/42 INSTALLATION INSTRUCTIONS

Chimney Sections

Catalog #

A

B

SL306

6 in.

4-3/4 in.

 

 

 

SL312

12 in.

10-3/4 in.

 

 

 

SL318

18 in.

16-3/4 in.

 

 

 

SL324

24 in.

22-3/4 in.

 

 

 

SL336

36 in.

34-3/4 in.

 

 

 

SL348

48 in.

46-3/4 in.

 

 

 

A = Actual length

B = Effective length (length of chimney part after it has been snapped to another)

Firestop Spacer

Catalog #

A

B

FS338

0-deg.

14-1/2 in.

 

 

 

FS339

15-deg.

18-3/8 in.

 

 

 

FS340

30-deg.

23 in.

CB876

Chimney Bracket

SL3 - Chimney Stabilizer

SL330 - Offset/Return

RF370 - Roof Flashing

RF371 - Roof Flashing

Flat to 6/12 Pitch

6/12 to 12/12 Pitch

JB877

AS8

Joint Band

Straight Attic

 

Insulation Shield

8

17335 Rev L

07/04

Hearth and Home Technologies E42, E39, E36 User Manual

E36/39/42 INSTALLATION INSTRUCTIONS

ST375

Square LDS33 (3 ft x 3 ft) Termination Cap LDS46 (4 ft x 6 ft)

Decorative Shroud

TS345/TS345P

Square

Termination Cap

TR344

Round

Termination Cap

TR342

Round Telescoping

Termination Cap

CT35

Chase Top

CAK4A

Chimney Air Kit

08/04

17335 Rev L

9

E36/39/42 INSTALLATION INSTRUCTIONS

D.PRE-INSTALLATION PREPARATION

1.Fireplace Locations and Space Requirements

Several options are available to you when choosing a location for your fireplace. This fireplace may be used as a room divider, installed along a wall, across a corner or used in an exterior chase. See Figure 2.

Locating the fireplace in a basement, near frequently opened doors, central heat outlets or returns, or other locations of considerable air movement can affect the performance and cause intermittent smoke spillage from the front of the fireplace. Consideration should be given to these factors before deciding on a location.

CLEARANCES!

A minimum 1/2 in. air clearance must be maintained at the back and sides of the fireplace assembly.

Chimney sections at any level require a 2 in. minimum air space clearance between the framing and chimney section.

Figure 2 - Fireplace Locations

Figures 3 and 4 show two typical installations assuming an outside air kit is being used. Therefore, an allowance must be made for 90-deg bends. Less space is required when ducting goes directly outside without forming elbows.

These are rough framing dimensions only.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cat #

 

A

B

 

 

 

Cat #

A

B

C

 

D

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E/EC36

 

42 in

45 in.

 

 

 

E/EC36

42 in.

72-3/4 in.

36-3/8 in.

 

15-5/8 in.

51-3/8 in.

 

 

1067 mm

1143 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1067 mm

1848 mm

924 mm

 

397 mm

1305 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E/EC39

 

45 in.

48 in.

 

 

 

E/EC39

45 in.

75-3/4 in.

37-7/8 in.

 

16-5/8 in.

53-1/2 in.

 

 

1143 mm

1219 mm

 

 

 

1143mm

1924 mm

962 mm

 

422 mm

1359 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E/EC42

 

48 in.

51 in.

 

 

 

E/EC42

48 in.

78-3/4 in.

39-3/8 in.

 

17-5/8 in.

55-3/8 in.

 

 

1219 mm

1295 mm

 

 

 

1219 mm

2000 mm

1000 mm

 

448 mm

1407 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 3

 

 

 

 

 

 

 

Figure 4

 

 

Installation Along a Wall or an Exterior Chase

 

 

 

Corner Installation

 

 

WARNING!

Do not draw outside air from garage spaces. Exhaust products of gasoline engines are hazardous.

Do not install outside air ducts such that the air may be drawn from attic spaces, basements or above the roofing where other heating appliances or fans and chimneys exhaust or utilize air. These precautions will reduce the possibility of fireplace smoking or air flow reversal.

WARNING!

To prevent contact with sagging or loose insulation, the fireplace must not be installed against vapor barriers or exposed insulation. Localized overheating could occur and a fire could result.

10

17335 Rev L

07/04

Loading...