Hearth and Home Technologies VRT-BZ-N-CE, VRT-BZ-P-CE, VRT-GY-N-CE, VRTIKL-CE, VRT-GY-P-CE User Manual

...
0 (0)

VRTIKL-CE

FREESTANDING STOVE

MODEL:

VRT-BZ-N-CE VRT-GY-P-CE VRT-GR-N-CE VRT-BZ-B-CE VRT-GY-N-CE VRT-GR-B-CE VRT-BZ-P-CE VRT-GY-B-CE VRT-GR-P-CE

Installer’s Guide

Installation and Operation

0063-06

CAUTION

DO NOT DISCARD THIS MANUAL

• Important operating

• Read, understand and follow

• Leave this manual with

and maintenance

these instructions for safe

party responsible for

instructions included.

installation and operation.

use and operation.

DO DISCARDNOT

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or death.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other gas stove.

What to do if you smell gas

-Do not try to light any gas stove. Do not touch any electrical switch. Do not use any phone in your building.

-Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

-If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

WARNING

HOT SURFACES!

Glass and other surfaces are hot during operation AND cool down.

Hot glass will cause burns.

DO NOT touch glass until it is cooled

NEVER allow children to touch glass

Keep children away

CAREFULLY SUPERVISE children in same room as fireplace.

Alert children and adults to hazards of high temperatures.

High temperatures may ignite clothing or other flammable materials.

Keep clothing, furniture, draperies and other flammable materials away.

This appliance has been supplied with an integral barrier to prevent direct contact with the fixed glass panel. DO NOT operate the appliance with the barrier removed.

Contact your dealer if the barrier is not present or help is needed to properly install one.

Installation and service of this gas stove should be performed by qualified personnel.

These instructions are valid for the following countries: GB, IE

Î

Heat & Glo • VRTIKL-CE • 7031-292 Rev E • 12/07

1

Read this manual before installing or operating this gas stove. Please retain this owner's manual for future reference.

Congratulations

Congratulations on selecting a Heat & Glo gas stove - an elegant and clean alternative to wood burning stoves. The Heat & Glo gas stove you have selected is designed to provide the utmost in safety, reliability, and efficiency.

As the owner of a new gas stove, you'll want to read and carefully follow all of the instructions contained in this Owner's Manual. Pay special attention to all Cautions and Warnings.

This Owner's Manual should be retained for future reference. We suggest that you keep it with your other important documents and product manuals.

The information contained in this Owner's Manual, unless noted otherwise, applies to all models and gas control systems.

Your new Heat & Glo gas stove will give you years of durable use and trouble-free enjoyment. Welcome to the Heat & Glo family of gas stove products!

SAMPLE OF RATINGS LABEL

LOCATION: IN CONTROL AREA, INSIDE LOWER ACCESS DOOR

Test Lab &

Report No.

Manufactured

Date

SERIAL NO.

 

Heat & Glo, a brand of Hearth & Home Technologies, Inc.

 

 

20802 Kensington Boulevard

 

 

 

 

 

Lakeville, MN 55044, USA

 

 

 

 

 

w w.heatnglo.com

 

 

 

MADE

 

 

 

 

 

 

 

Model: ION-CE

 

 

 

IN USA

0087

 

 

 

 

 

 

 

 

 

 

Gas Type

G20

G20

 

G20

G2 5

Destination

ES, GB, IE, PT, NO

DE, LU

 

FR

 

N L

CAT

I2 H

I 2E

 

I2E

R

I2L

Qn

7.6

7.6

 

7.6

6.2

P n

20 mbar

20 mbar

20/25 mbar

25 mbar

Pmax

8.7 mbar

8.7 mbar

 

8.7 mbar

8.7 mbar

SAMPLE

Injector

#39DMS

#39DMS

 

#39DMS

#39DMS

 

Not for use with solid fuel.

 

 

 

 

 

F

 

 

 

 

G Alcove

 

B

C

H

 

A

A

 

E

D

 

 

 

 

A

A

 

 

 

 

 

 

C

 

 

 

 

 

 

inimum Clearances to Combustibles

 

 

- Side of appliance top to side wall..............

 

 

15.2 cm

B

- Rear of appliance to back wall ...................

 

 

7.6 cm

C

- Corner of appliance top to side wall

..........

12.7 cm

D

- Minimum Alcove Height...........................

 

 

137.2 cm

E

- Maximum Alcove Depth ............................

 

 

91.4 cm

F

- Minimum Alcove Width

.............................

 

 

78.1 cm

G - Top of appliance to alcove ...........ceiling

 

 

33.7 cm

H

- Mantle Clearance from .......appliance top

26.7 cm

DO NOT REMOVE OR COVER THIS LABEL.

This appliance must be installed in accordance with the codes enforced, and used only in

ventilated space. Consult instructions before installation and use of

this appliance.

Manufactured by:

Date of Manufacture:

Serial No.

Model Name

2

Heat & Glo • VRTIKL-CE • 7031-292 Rev E • 12/07

- TABLE OF CONTENTS -

Section 1: Listing and Code Approvals

 

A. Gas Stove Certifications ...........................

4

B. Glass Specifications .................................

4

C. Non-Combustible Materials ......................

4

D. Combustible Materials ..............................

4

Section 2:

Getting Started

 

A. Design & Installation Considerations ........

5

B. Inspect Gas Stove & Components............

5

Section 3: Gas Stove Location & Clearances

 

A. Selecting Gas Stove Location...................

6

B. Clearances to Combustibles.....................

6

C. Optional Stone Surround Installed............

7

Section 4:

Termination Locations

 

A. Flue Termination Clearances....................

8

Section 5:

Flue Information

 

A. Flueing Components...............................

10

B. Use of Elbows.........................................

10

C. Measuring Standards..............................

10

D. Flueing Diagrams....................................

11

E. Horizontal Termination............................

16

F. Slim Line Wall Thimble ..........................

17

G. Vertical Termination................................

19

H. Vertical Flue Restrictor ...........................

21

Section 6:

Gas Information

 

A. Gas Pressure Requirements ..................

22

B. Gas Connection.. .................................... 22

Section 7:

Electrical Information

 

A. Ignition System Wiring ............................

23

Section 8: Gas Stove Setup

 

A. Remove Shipping Materials....................

24

B. Unbolting Gas Stove from the Pallet.......

24

C. Leveling and Lagging Down the

 

 

Gas Stove ...............................................

24

D. Accessories ............................................

25

E. Top to Rear Vent Conversion .................

25

F.

Installing the Baffle .................................

26

G. Positioning the Logs ...............................

27

H. Mineral Wool...........................................

27

I. Front Door Glass Assembly....................

28

J. Inner Glass Door Replacement ..............

28

Section 9:

Operating Instructions

 

A. Before Lighting Gas Stove......................

29

B. Lighting Gas Stove .................................

30

C. After Gas Stove is Lit ..............................

31

D. Frequently Asked Questions...................

31

Section 10: Maintaining & Servicing Gas Stove

A. Maintenance Tasks..........................................

33

B. Service and Maintenance Log .........................

34

Section 11:

Troubleshooting............................

35

Section 12:

Reference Materials

 

A. Gas Stove Dimension Diagram ..............

35

B. Gas Stove Dimension with Stone

 

 

Surround Diagram ..................................

36

C. Flue Components Diagram.....................

37

D. Flue Components List.............................

38

E.

Service Parts List....................................

40

F.

Warranty Policy.......................................

43

G.

Contact Information ................................

44

Î = Contains updated information.

Heat & Glo • VRTIKL-CE • 7031-292 Rev E • 12/07

3

1Listing and Code Approvals

A. Appliance Certification

MODEL

VRTIKL-CE

LABORATORY

Gastec Certification B.V.

TYPE

Gas Stove

STANDARD

EN 613:2001

DIRECTIVE

CAD90/396/EEC

These instructions are only valid if the following country symbol is on the gas stove. If this symbol is not present on the gas stove, it is necessary to refer to the technical instructions which will provide the necessary information concerning the modification of the gas stove to the conditions of use for the country.

C. Non-Combustible Materials

Materials that are reported as passing ASTM E 136, Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750°C, shall be considered non-combustible materials.

D. Combustible Materials

Materials made of or surfaced with wood, compressed paper, plant fibers, plastics, or other materials that can ignite and burn, whether flame proofed or not, or whether plastered or unplastered shall be considered combustible materials.

B. Glass Specifications

This gas stove is equipped with 5mm ceramic glass behind the curved glass. Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass.

WARNING

Do NOT use this gas stove if any part has been under water. Immediately call a qualified service technician to inspect the gas stove and to replace any part of the control system and any gas control which has been under water.

4

Heat & Glo • VRTIKL-CE • 7031-292 Rev E • 12/07

2 Getting Started

A. Design & Installation Considerations

Heat & Glo direct flue gas stoves are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional air source is required.

CAUTION

Check building codes prior to installation.

Installation MUST comply with local, regional, state and national codes and regulations.

Consult local building, fire officials or authorities having jurisdiction about restrictions, installation inspection, and permits.

When planning an installation, it is necessary to determine the following information before installing.

Where the gas stove is to be installed.

The flue system configuration to be used.

Gas supply piping.

Electrical wiring.

B. Inspect Appliance & Components

WARNING

Inspect gas stove and components for damage. Damaged parts may impair safe operation.

• Do NOT install damaged components.

Do NOT install incomplete components.

Do NOT install substitute components.

Report damaged parts to dealer.

Carefully remove the gas stove and components from the packaging.

Remove door and set aside on protective surface.

Remove log set and component pack from firebox.

Report to your dealer any parts damaged in shipment, particularly the condition of the glass.

Read all of the instructions before starting the installation. Follow these instructions carefully during the installation to ensure safety and benefit.

WARNING

Hearth & Home Technologies disclaims any responsibility for, and the warranty will be voided by, the following actions:

Installation and use of any damaged gas stove or flue system component.

Modification of the gas stove or flue system.

Installation other than as instructed by Hearth & Home Technologies.

Improper positioning of the gas logs or the glass door.

Installation and/or use of any component part not approved by Hearth & Home Technologies.

Any such action may cause a fire hazard.

Heat & Glo • VRTIKL-CE • 7031-292 Rev E • 12/07

5

3Appliance Location and Clearances

NOTE:

 

WARNING

· Illustrations reflect typical installations and are FOR

 

Fire Risk

DESIGN PURPOSES ONLY.

· Illustrations/diagrams are not drawn to scale.

Provide adequate clearance:

Around air openings

· Actual installation may vary due to individual design

To combustibles

preference.

For service access

 

Locate gas stove away from traffic areas.

A. Selecting Appliance Location

When selecting a location for your gas stove it is important to consider the required clearances to walls (see Figure 3.1).

NOTE: For actual gas stove dimensions refer to Section 12.

B. Clearances to Combustibles

F

B

E

A

I

“A” measurement is from gas stove top, not side.

Alcove

G

H

A A

D

 

A

B

C

D

E

F

G

H

I

Centimeters

15.2

25.7

30.8

137.2

91.4

78.1

33.7

33.7

39.4

 

 

 

 

 

 

 

 

 

 

Figure 3.1

6

Heat & Glo • VRTIKL-CE • 7031-292 Rev E • 12/07

C. Optional Stone Surround Installed

 

B

C

 

 

 

 

 

 

 

 

 

 

D

A

 

 

 

A

 

A

B

C

D

Centimeters

8.3

10.2

78.1

91.4

Figure 3.1

 

 

 

 

WARNING

Fire Risk.

Odor Risk.

Tipping Risk

Install gas stove on a stable, level platform/ floor strong enough to support gas stove without tipping.

USE wood flooring, ceramic tile, brick hearth or high pressure laminate flooring applied directly over the sub-flooring material.

 

Heat & Glo • VRTIKL-CE • 7031-292 Rev E • 12/07

7

 

4Termination Locations

A. Flue Termination Minimum Clearances

WARNING

Fire Risk. Explosion Risk.

Maintain flue clearance to combustibles as specified.

Do not pack air space with insulation or other materials.

Failure to keep insulation or other materials away from flue pipe may cause fire.

Measure vertical clearances from this surface.

Measure horizontal clearances from this surface.

(See Figure 4.4 for specific clearances.)

Figure 4.1 Termination Clearances

 

 

 

GAS, WOOD OR FUEL

 

 

 

 

 

 

 

 

OIL TERMINATION

 

 

 

61cm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(MINIMUM) TO

 

 

 

 

 

 

 

 

 

 

 

 

 

PERPENDICULAR

 

 

 

 

 

 

GAS

 

 

 

 

 

WALL

 

 

 

TERMINATION

 

 

 

(GAS ON LY)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H (MIN.) - MINIMUM HEIGHT FROM ROOF

TO LOWEST DISCHARGE OPENING

Roof Pitch

H (Min.) M

Flat to 6/12..............................................................

30*

Over 6/12 to 7/12....................................................

38*

Over 7/12 to 8/12....................................................

46*

Over 8/12 to 9/12....................................................

61*

Over 9/12 to 10/12..................................................

76

Over 10/12 to 11/12 ................................................

99

Over 11/12 to 12/12 .............................................

1.22

Over 12/12 to 14/12.............................................

1.52

Over 14/12 to 16/12.............................................

1.83

Over 16/12 to 18/12.............................................

2.13

Over 18/12 to 20/12.............................................

2.29

Over 20/12 to 21/12.............................................

2.44

*.91M minimum in snow regions

Figure 4.3 Minimum Height from Roof to Lowest Discharge Opening

Figure 4.3 specifies minimum flue heights for various pitched roofs.

 

Gas Termination

Wood & Fuel Oil Termination

 

 

 

A

15 cm

51 cm

Figure 4.2 Multiple Vertical Termination

8

Heat & Glo • VRTIKL-CE • 7031-292 Rev E • 12/07

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

P

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See Notes 3 & 4

 

 

 

(See Note 2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T

S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

S

Electrical

 

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Service

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

= VENT TERMINAL

X = AIR SUPPLY INLET

 

 

 

 

= AREA WHERE TERMINAL IS NOT PERMITTED

 

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

=

 

31 cm ....................

clearances above grade, veranda,

 

K

 

=

1.8 M.......................

 

clearance to a mechanical

 

 

 

 

 

(See Note 1)

porch, deck or balcony

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(powered) air supply inlet

 

 

 

 

 

 

L**

 

=

2.1 M

 

clearance above paved

B

=

 

31 cm

clearances to window or door

 

 

 

 

 

 

 

 

 

 

(See Note 1)

 

sidewalk or a paved driveway

 

 

 

 

 

 

that may be opened, or to perma-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

located on public property

 

 

 

 

 

 

nently closed window. (Glass)

 

M*** =

46 cm ......................

 

clearance under veranda, porch,

D*

=

 

31 cm

vertical clearance to unventilated

 

 

 

 

 

 

 

 

 

 

 

 

 

 

deck, balcony or overhang

 

 

 

 

 

 

 

1.1 M

 

vinyl

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

soffit or to ventilated soffit located

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

above the terminal

 

S

=

15 cm.......................

 

clearance from sides of elec-

 

 

 

 

 

76 cm

for vinyl clad soffits and below

 

 

 

 

 

 

 

(See Note 5)

 

trical service

 

 

 

 

 

 

 

 

 

 

 

T

=

31 cm

 

clearance above electrical

 

 

 

 

 

 

electrical service

 

 

F

=

 

23 cm

clearance to outside corner

 

 

 

 

 

 

 

 

(See Note 5)

 

service

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G

=

 

15 cm

clearance to inside corner

 

 

 

Alcove Applications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

=

 

 

15 cm

 

non-vinyl sidewalls

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

=

 

91 cm ....................

not to be installed above a gas

 

 

 

 

 

 

 

 

31 cm .....................

 

vinyl sidewalls

 

 

 

 

 

 

 

 

 

 

 

meter/regulator assembly within 90

 

 

P

 

=

 

 

2.4 M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cm horizontally from the center-line

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

of the regulator

 

 

 

 

 

 

 

 

 

 

 

 

 

QMIN

 

 

 

RMAX

 

 

 

 

 

I

=

 

1.8 M

clearance to gas service regulator

 

 

 

 

1 cap

 

 

.91 M

 

 

 

2 x Q ACTUAL

 

 

 

 

 

 

 

 

2 caps

 

 

1.8 M

 

 

 

1 x Q ACTUAL

 

 

 

 

 

 

 

 

 

vent outlet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 caps

 

 

2.7 M

 

2/3 x Q ACTUAL

 

 

 

J

=

31 cm

clearance to non-mechanical

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 caps

 

 

3.7 M

 

1/2 x Q ACTUAL

 

 

 

 

 

 

 

 

 

air supply inlet to building or the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

combustion air inlet to any other

 

 

 

QMIN = # termination caps x 3 RMAX = (2 / # termination caps) x QACTUAL

 

 

 

 

 

 

 

 

gas stove

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

**a flue shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings.

***only permitted if veranda, porch, deck or balcony is fully open on a minimum of 2 sides beneath the floor, or meets Note 2.

NOTE 1: On private property where termination is less than 7 feet above a sidewalk, driveway, deck, porch, veranda or balcony, use of a listed cap shield is suggested. (See flue components page)

NOTE 2: Termination in an alcove space (spaces open only on one side and with an overhang) are permitted with the dimensions specified for vinyl or non-vinyl siding and soffits. 1. There must be 2.7M minimum between termination caps. 2. All mechanical air intakes within 3M of a termination cap must be a minimum of 2.7M below the termination cap. 3. All gravity air intakes within 2.7M of a termination cap must be a minimum of .31M foot below the termination cap.

Figure 4.4 Minimum Clearances for Termination

NOTE 3: Local codes or regulations may require different clearances.

NOTE 4: Termination caps may be hot. Consider their proximity to doors or other traffic areas.

NOTE 5: Location of the flue termination must not interfere with access to the electrical service.

Heat & Glo assumes no responsibility for the improper performance of the gas stove when the flueing system does not meet these requirements.

Heat & Glo • VRTIKL-CE • 7031-292 Rev E • 12/07

9

5 Flue Information

A. Flue Components

These models are approved to use Simpson Dura-Vent or Hearth & Home Technologies series pipes, components and termination. Approved components are labeled for identification. This pipe is tested and listed as an approved component of the stove.

DO NOT USE FIELD-FABRICATED FLUE COMPONENTS. Refer to the flue manufacturer’s instructions.

This product is approved to be flued either horizontally, through the side wall or vertically through the roof. You may flue through a Class A or masonry chimney if an approved adapter is used.

This gas stove is a balanced flue gas stove. All combustion air must come directly from the outside of the building. The flue pipe for this unit consists of an inner and an outer pipe. The inner pipe carries the gas stove exhaust out of the system, and the outer pipe brings fresh combustion air into the gas stove.

A round support box/wall thimble or heat shield is required when the flueing passes through a combustible wall.

A support box or ceiling firestop is required when the flueing passes through a combustible ceiling.

Roof flashing and a storm collar are required when flueing passes through the roof.

Follow instructions provided with the flueing for installation of these items.

WARNING

Fire Hazard. Explosion Risk. Asphyxiation Risk.

Do NOT connect this gas gas stove to a chimney flue serving a separate solid-fuel or gas burning gas stove.

Flue this gas stove directly outside.

Use separate flue system for this gas stove.

May impair safe operation of this gas stove or other gas stoves connected to the flue.

B. Use of Elbows

CAUTION

ALL flue configuration specifications MUST be followed.

This product is tested and listed to these specifications.

Appliance performance will suffer if specifications are not followed.

Diagonal runs have both vertical and horizontal flue aspects when calculating the effects. Use the rise for the vertical aspect and the run for the horizontal aspect. (See Figure 5.1.)

Two 45° elbows may be used in place of one 90° elbow. On 45° runs, one foot of diagonal is equal to 21.6 cm horizontal run and 21.6 cm vertical run. A length of straight pipe is allowed between two elbows. (See Figure 5.1.)

Vertical

.5

cm

cm

.

30

 

6

 

21

21.6 cm

Horizontal

Figure 5.1

C. Measuring Standards

Vertical and horizontal measurements were made using the following standards.

Pipe measurements are from center line to center line.

Horizontal terminations are measured to the outside of the mounting surface (flange of termination cap). See

Figure 4.1 on page 8.

Horizontal pipe should be installed level with no rise.

10

Heat & Glo • VRTIKL-CE • 7031-292 Rev E • 12/07

D. Flueing Diagrams

STRAIGHT UP VERTICAL FLUE V

11.8M Maximum

For Natural, Propane and Butane Gases.

Note: For this type of installation, the vertical

flue restrictor must be added. See section H V for instructions.

Figure 5.2

STRAIGHT OUT HORIZONTAL FLUE H

61cm Maximum

For Natural, Propane and Butane Gases.

H

Figure 5.3

Heat & Glo • VRTIKL-CE • 7031-292 Rev E • 12/07

11

 

Natural Gas • One 900 Elbow System

 

V Minimum

H Maximum

 

46 cm

1.3 M

 

92 cm

2.7 M

 

1.4 M

4.1 M

 

1.8 M

5.0 M

 

V+H = Max 11.6 M

H Max = 5.0 M

 

Propane • One 900 Elbow System

 

V Minimum

H Maximum

 

46 cm

92 cm

 

92 cm

1.8 M

 

1.4 M

2.8 M

 

1.8 M

3.6 M

 

V+H = Max 11.6 M

H Max = 3.6 M

 

Butane • One 900 Elbow System

V

V Minimum

H Maximum

46 cm

46 cm

 

92 cm

92 cm

 

1.4 M

1.4 M

 

1.8 M

1.8 M

 

V+H = Max 10 M

H Max = 1.8 M

 

H

 

Figure 5.4

 

 

Natural Gas • One 900 Elbow System

 

V Minimum

H Maximum

 

46 cm

1.3 M

 

92 cm

2.7 M

 

1.4 M

4.1M

 

1.8 M

5.0 M

 

V+H = Max 11 M

H Max = 5.0 M

H

 

 

Propane • One 900 Elbow System

 

V Minimum

H Maximum

V

46 cm

92 cm

92 cm

1.8 M

 

1.4 M

2.8 M

 

1.8 M

3.6 M

 

V+H = Max 11 M

H Max = 3.6 M

 

Butane • One 900 Elbow System

 

V Minimum

H Maximum

 

1.22 M

92 cm

 

1.4 M

1.4 M

 

1.8 M

1.8 M

 

V+H = Max 10 M

H Max = 1.8 M

 

Figure 5.5

 

 

12

 

Heat & Glo • VRTIKL-CE • 7031-292 Rev E • 12/07

Hearth and Home Technologies VRT-BZ-N-CE, VRT-BZ-P-CE, VRT-GY-N-CE, VRTIKL-CE, VRT-GY-P-CE User Manual

Natural Gas • Two 900 Elbows System

 

V Min.

H1 Max.

H1 + H2 Max.

 

46 cm

55 cm

1.1 M

 

92 cm

1.1 M

2.2 M

 

1.4 M

1.7 M

3.5 M

 

1.8 M

2.2 M

4.5 M

 

V+H1+H2 = Max 11.0M

H1 Max = 2.2M

H1+H2 = Max 4.5M

 

 

 

V

 

Propane • Two 900 Elbows System

 

V Min.

H1 Max.

H1 + H2 Max.

 

46 cm

39 cm

69 cm

 

92 cm

75 cm

1.3 M

 

1.4 M

1.1 M

2.1 M

 

1.8 M

1.5 M

2.7 M

 

V+H1+H2 = Max 10.6M

H1 Max = 1.5M

H1+H2 = Max 2.7M

 

Butane • Two 900 Elbows System

 

V Min.

H1 Max.

H1 + H2 Max.

 

1.22 M

48 cm

61 cm

 

1.4 M

.5 M

.7 M

 

1.8 M

.7 M

.9 M

 

V+H1+H2 = Max 10M

H1 Max = .7M H1+H2 = Max .9M

 

 

 

H2

H1

 

 

 

Figure 5.6

 

 

 

Natural Gas • Two 900 Elbows System

Propane • Two 900 Elbows System

Butane • Two 900 Elbows System

V Min.

H1 Max.

H1 + H2 Max.

V Min.

H1 Max.

H1 + H2 Max.

V Min.

H1 Max.

H1 + H2 Max.

46 cm

55 cm

1.1 M

46 cm

39 cm

69 cm

1.22 M

48 cm

61 cm

92 cm

1.1 M

2.3 M

92 cm

75 cm

1.3 M

1.4 M

.5 M

.7 M

1.4 M

1.7 M

3.5 M

1.4 M

1.1 M

2.1 M

1.8 M

.7 M

.9 M

1.8 M

2.2 M

4.5 M

1.8 M

1.5 M

2.7 M

V+H1+H2 = Max 10M

H1 Max = .7

H1+H2 = Max .9M

V+H1+H2 = Max 10M

H1 Max = 2.2M

H1+H2 = Max 4.5M

V+H1+H2 = Max 10M

H1 Max = 1.5M

H1+H2 = Max 2.7M

 

 

 

 

 

H2

 

 

 

 

 

 

 

 

 

 

V

 

 

 

 

 

 

 

 

 

H1

 

 

 

Figure 5.7

 

 

 

 

 

 

 

 

 

 

 

Heat & Glo • VRTIKL-CE • 7031-292 Rev E • 12/07

 

 

13

 

Natural Gas • Two 900 Elbows System

 

V1 Min.

H Max.

 

31 cm

93 cm

 

61 cm

1.8 M

 

91 cm

2.7 M

 

1.2 M

3.6 M

 

1.5 M

4.5 M

V2

V1+V2+H = Max 11.4M

H Max = 4.5M

Propane • Two 900 Elbows System

 

 

V1 Min.

H Max.

 

31 cm

62 cm

V1

61 cm

1.2 M

91 cm

1.8 M

H

1.2 M

2.4 M

 

1.5 M

3.0 M

 

V1+V2+H = Max 11.4M

H Max = 3.0M

 

Butane • Two 900 Elbows System

 

V1 Min.

H Max.

 

31 cm

31 cm

 

61 cm

61 cm

 

92 cm

92 cm

 

1.2 M

1.2 M

 

1.5 M

1.5 M

 

V1+V2+H = Max 10 M

H Max = 1.0 M

Figure 5.8

Natural Gas • Two 900 Elbows System

 

V Min.

H1+H2 Max.

 

61 cm

1.6 M

 

91 cm

2.4 M

H2

1.2 M

3.2 M

 

1.5 M

4.0 M

H1

V+H1+H2 = Max 11.4M

H1+H2 = Max 4.0M

Propane • Two 900 Elbows System

 

V Min.

H1+H2 Max.

 

61 cm

1.0 M

 

91 cm

1.5 M

V

1.2 M

2.0 M

 

1.5 M

2.6 M

 

V+H1+H2 = Max 11.4M

H1+H2 = Max 2.6M

 

Butane • Two 900 Elbows System

 

V1 Min.

H1+H2 Max.

 

61 cm

42 cm

 

92 cm

64 cm

 

1.2 M

.8 M

 

1.5 M

1.0 M

 

V+H1+H2 = Max 10 M

H1+H2 = Max 1.5 M

 

Figure 5.9

 

 

14

 

Heat & Glo • VRTIKL-CE • 7031-292 Rev E • 12/07

Loading...