Hatco AFST-2X Installation Manual

0 (0)
INSTALLATION & OPERATION MANUAL
AND REPLACEMENT PARTS LIST
HEATED HOLDING CABINET
MODEL AFST-2X
HATCO CORPORATION MILWAUKEE, Wl 53234 U.S.A. (800)558-0607 (414)671-6350
&
OPERATION PROCEDURES
Model AFST
-
2X
To avoid any injury, turn the power switch off, unplug the
unit from the power source and allow to cool before performing
any maintenance.
Some exterior surfaces on the unit will get hot. Use caution
when touching these areas to avoid injury.
The unit must be transported in an upright position. If laid
on its side, all glass surfaces must be secured with tape.
For safe and proper operation, the unit must be located a
reasonable distance from combustible walls and materials. If safe
distances are not maintained, discoloration or combustion could
occur.
Locate the unit at the proper counter height, in an area that
is convenient for use. The location should be level to prevent the
cabinet or its contents from accidentally falling, and strong
enough to support the weight of the unit and food displayed.
Plug the unit into an electrical outlet of the correct voltage,
size and plug configuration. If the plug and receptacle do not
match, contact a qualified electrician to determine the proper
voltage and size, and install the proper electrical outlet .
Abrasive cleaners could scratch the finish of your unit.
0nly bulbs which meet or exceed N.S.F. standards, specifi-
cally designed for food holding areas must be used. Breakage of
bulbs not specially coated could result in personal injury and/or
food contamination.
ELECTRICAL SPECIFICATIONS
Voltage
Wattage
Amps
Plug
Configuration
Shipping
Weight
120/208 1835 11.7 NEMAL14-20P
120/240 1835 11.7 NEMAI.14-20P
188lbs.
(85 kg)
CAUTION
Before Installing plug into electrical receptacl e, measure
voltage at the receptacle from "neutral" to each "hot leg".
Voltage at these connections must not exceed 125 Volts.
DIMENSIONS
Overall Dimensions
32-7/8”L x 27”D x 30”H (83 x 69 x 76 cm)
Rack Dimensions
27”W x 19-3/4”D x 21-1/4”H (69 x 50 x 54 cm)
INSTALLATION
1. Remove unit from box.
2. Remove tape, packing materials and protective film from all surfaces
of unit.
3. Install door handles to top of doors using the screws provided.
4. Install the display signs and acrylic panels into the brackets at the top
of the cabinet sides.
OPERATION
1. Plug unit into an electrical outlet of the correct voltage, size
and plug configuration. See Electrical Specifications for
details.
CAUTION
Before Installing plug Into electrical receptacle, measure
voltage at the receptacle from "neutral" to each "hot leg".
Voltage at these connections must not exceed 125 Volts.
2. Turn the Power Switch on the control panel to the ON posi-
tion.
3. To set temperature, turn the red Mode Switch counter clock-
wise to the SP-1 posi tion indicated on the controller.
4. Adjust the Set point Screw to the desired temperature and
turn the red Mode Switch to the TEMP position. The surface
temperature range is room temperature to 220° F. (104°C).
5. Allow 15-20 min 5. Allow 15-20 minutes for unit to reach operating temperature.
Control Panel
MAINTENANCE
Your Holding & Display Cabinet is designed for maximum dura-
bility and performance, with minimum maintenance.
To avoid any injury, turn the power switch off, unplug the
unit from the power source and allow to cool before performing
any maintenance.
CLEANING
To preserve the bright finish of the cabinet, it is recommended
that the exterior and interior surfaces be wiped daily with a damp
cloth. Stubborn stains may be removed with a good stainless
steel cleaner or a non-abrasive cleaner. Hard to reach areas
should be cleaned with a small brush and mild soap.
Abrasive cleaners could scratch the finish of the cabinet.
Clean the glass sides using a common glass cleaner.
LIGHT BULB REPLACEMENT
The display lights are shatter-resistant incandescent light
bulbs which illuminate the warming area. These bulbs have a
special coating to guard against injury and food contamination in
the event of breakage.
1. To replace a bulb, disconnect the power supply from the unit
and wait until the unit has cooled.
2. Bulbs have a threaded base. Unscrew the light bulb from the
unit and replace it with a new specially coated incandescent
bulb.
Installation, maintenance and repair to be performed
by qualified service personnel only.
SAFETY PRECAUTIONS
Mode Switch
Setpoint Screw
Printed June
1
998
Form No. AFSTM
-
0698
Loading...