Product Information

Requires 1/2" supply lines (not included)

 

Max. mounting surface thickness

1 1/8"

Hole sizes in mounting surface

 

Spout

1 3/8"

 

Valves

1 1/4"

 

Max. incoming water pressure

145 PSI

Recommended incoming water pressure

22 - 72 PSI

Max. incoming hot water temp.

176°F*

Recommended incoming hot water temp.

120° - 140°F*

Max. flow rate -- lavatory faucets

2.2 gpm

Max. flow rate -- bidet faucet

2.2 gpm

The bidet faucet is not suitable for use on vertical spray bidets.

This faucet may be used with a continuous flow water heater if the flow pressure is at least 20 PSI.

For best results, Hansgrohe recommends that this faucet be installed by a licensed, professional plumber.

*Please know and follow all applicable local codes when setting the temperature on the water heater.

31063XX1

31263XX1

Hans Grohe 31730001, 31263XX1, 31063XX1 User Manual

32310XX1

31730XX1

Note:

To prevent shipping damage, the spout is attached to the spout escutcheon with two adhesive strips. These strips must be removed before the spout is installed.

Loosen the spout screw with a 2.5 mm Allen wrench.Pull the spout away from the escutcheon.

Remove the adhesive strips.

adhesive strips

 

Reassemble the spout assembly so that the hole for the pull rod is at the rear of the spout.

Installation

Remove the valve mounting nuts from the valves.

From below the mounting surface, push the valves up into the holes. Install the mounting nuts on the valves.

Tighten the tensioning screws.

Place the handles over the valve mounting nuts. Tighten the handles by rotating the escutcheons clockwise.

The handles should be parallel to the basin. If necessary, loosen the tensioning screws and rotate

the valve slightly.

Install the spout. Rotate the spout escutcheon if necessary, so that the hole for the pull rod is at the rear.

Tighten the mounting nut. Tighten the tensioning screws.