WARRANTY
These instruments are warranted for two years against defects in workmanship and materials when used for their intended purpose and maintained according to instructions. Probes are warranted for six months. This warranty is limited to repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack of prescribed maintenance are not covered. If service is required, contact the dealer from whom you purchased the instrument. If under warranty, report the model number, date of purchase, serial number and the nature of the failure. If the repair is not covered by the warranty, you will be notified of the charges incurred. If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization Number from the Customer Service department and then send it with shipment costs prepaid. When shipping any instrument, make sure it is properly packaged for complete protection.
Recommendations for Users
Before using these products, make sure that they are entirely suitable for the environment in which they are used. Operation of these instruments in residential areas could cause unacceptable interferences to radio and TV equipment. The glass bulb at the end of the electrode is sensitive to electrostatic discharges. Avoid touching this glass bulb at all times. During operation, ESD wrist straps should be worn to avoid possible damage to the electrode by electrostatic discharges. Any variation introduced by the user to the supplied equipment may degrade the instrument’s EMC performance. To avoid electrical shock, do not use these instruments when voltages at the measurement surface exceed 24 Vac or 60 Vdc. To avoid damages or burns, do not perform any measurement in microwave ovens.
Dear Customer,
Thank you for choosing a Hanna product.
This manual will provide you with the necessary information for the correct operation of the meter. Please read it carefully before using the instrument.
If you need additional technical information, do not hesitate
to e-mail us at |
tech@hannainst.com. |
|
These instruments |
are in compliance with the |
directives. |
PRELIMINARY EXAMINATION
Remove the instrument from the packing material and examine it carefully. If any damage has occurred during shipment, immediately notify your Dealer or the nearest Hanna Customer Service Center.
Each meter is supplied with:
•Mounting brackets
•Instruction manual
Note: Conserve all packing material until the instrument has been observed to function correctly. Any defective item must be returned in its original packing.
SPECIFICATIONS
Range |
0.00 to 14.00 pH |
Resolution |
0.01 pH |
Accuracy (@ 20°C/68°F) |
±0.02 pH |
Typical EMC Deviation |
±0.10 pH / ±0.10 mA |
|
|
Calibration |
Manual, through Offset & Slope trimmers |
|
|
Dosing Contact |
Maximum 2A (fuse protected), |
|
250 Vac, 30 Vdc |
|
|
Dosing Selection |
Acid or Alk, selectable on the back panel |
Contact Open=Acid dosage=Relay ON if Measure > Setpoint Contact Close=Alk dosage=Relay ON if Measure < Setpoint
Setpoint |
|
Adjustable, from 0 to 14 pH |
Overtime |
Adjustable, typically from 5 to approx. 30 minutes |
|
|
|
|
Recorder Output |
|
4 to 20 mA, accuracy ±0.20 mA, |
|
|
500 Ω maximum load |
|
|
|
Power Consumption |
10 VA |
|
|
|
|
Installation Category |
II |
|
|
|
|
Power supply: |
|
External (fuse protected) |
BL931700-0 |
|
12 Vdc |
BL931700-1 |
|
115/230 Vac ; 50/60Hz |
|
|
|
Dimensions |
|
83 x 53 x 99 mm (3.3x2.1x3.9”) |
|
|
|
GENERAL DESCRIPTION |
ASSEMBLING VIEW |
BL931700-0 and BL931700-1 are panel-mounted pH indi- |
|
cators and controllers designed for simplicity of use in a wide |
|
range of industrial applications. |
|
Connections and wiring to electrode, power supply, contacts |
|
and external recorders are made via the terminal blocks on |
|
the rear panel. The meters are equipped with a BNC socket |
|
and accept input from conventional pH electrodes. |
|
Other features include: 4-20 mA output, overtime control |
|
system, selection of dosing direction (Acid/Alk), contact for |
|
external control and disabling of dosing action, multi-colour |
|
LED for indicating if the meter is in measurement/dosing/ |
|
alarm condition, possibility to set (Off-Auto-On switch) dosing |
|
action mode. |
|
Two models are available: |
|
• BL 931700-0 powered at 12 Vdc |
|
• BL 931700-1 powered at 115 or 230 Vac |
|
ACCESSORIES
pH CALIBRATION SOLUTIONS
HI 7004M/L pH 4.01 buffer solution, 230/500 mL bottle HI 7006M/L pH 6.86 buffer solution, 230/500 mL bottle HI 7007M/L pH 7.01 buffer solution, 230/500 mL bottle HI 7009M/L pH 9.18 buffer solution, 230/500 mL bottle
HI 7010M/L pH 10.01 buffer solution, 230/500 mL bottle
OTHER SOLUTIONS
HI 70300M/L Electrode storage solution, 230/500 mL bottle
HI 7061M/L Electrode general cleaning solution, 230/500 mL HI 7073M/L Protein cleaning solution, 230/500 mL bottle HI 7074M/L Inorganic cleaning solution, 230/500 mL bottle HI 7077M/L Oil & Fat cleaning solution, 230/500 mL
REFILLING ELECTROLYTE SOLUTIONS (50 mL, 4 pcs.) HI 7071 3.5M KCl+AgCl, for single junction electrodes HI 7072 1M KNO3 solution
HI 7082 3.5M KCl, for double junction electrodes
pH ELECTRODES |
|
|
HI 1002/5 |
BNC connector, double junction, plastic-body |
|
|
w/external thread & 5 m (16.5’) cable |
|
HI 1090T |
Screw connector, double junction, glass-body |
|
|
with external thread |
|
HI 1110S |
Screw connector, single junction, glass-body |
|
HI 1210T |
Screw connector, double junction, plastic-body |
|
|
with external thread |
|
HI 2114P/2 |
BNC connector, double junction, plastic-body |
|
|
with 2 m (6.6’) cable |
|
HI 1210B/5 |
BNC connector, double |
junction, plastic-body, |
|
with 5 m (16.5') cable |
|
HI 2910B/5 |
BNC connector, double |
junction, plastic-body, |
|
with built-in amplifier and 5 m (16.5') cable |
|
EXTENSION CABLES, SCREW TO BNC CONNECTOR |
||
HI 7855/5 |
Extension cable 5 m (16.5') long |
|
HI 7855/10 |
Extension cable 10 m (33') long |
|
OTHER ACCESSORIES |
|
|
BL PUMPS |
Dosing Pumps (flow rate from 1.5 to 20LPH) |
|
HI 6050 |
Submersible electrode holder, 60 cm (24”) |
|
HI 6051 |
Submersible electrode holder, 110 cm (43”) |
|
HI 6054B |
Electrode holder for in-line applications |
|
HI 6054T |
Electrode holder for in-line applications |
|
HI 710005/6 |
12 Vdc power adapter, US/European plug |
|
HI 731326 |
Calibration screwdriver (20 pcs) |
|
HI 740146 |
Mounting brackets |
|
HI 7871 |
Level Controller (min and max) |
|