Guardian AC4100 User Manual [en, es, fr]

0 (0)
Guardian AC4100 User Manual

USE & CARE INSTRUCTIONS

II

I

 

Guardian Technologies LLC

7700 St Clair Avenue | Mentor, Ohio 44060 1.866.603.5900 | www.guardiantechnologies.com

Air Cleaning System

Model No. AC4100

 

English

E - 1

1-Year Limited Warranty

 

French

F - 1

www.guardiantechnologies.com

 

Spanish

S - 1

1.866.603.5900

 

Date Purchased

REV0813

 

 

month ________

 

 

 

 

Replacement Filter No: Filter E

(FLT4100)

year _________

 

 

 

To Order Contact Customer Service

1.866.603.5900 or log on to www.guardiantechnologies.com

E-1

READ AND SAVE THESE INSTRUCTIONS

WARNINGS

Failure to comply with the warnings listed below may result in electric shock or serious injury.

This product should be used only in accordance with the specifications outlined in this manual. Usage other than what has been specified here may result in serious injury.

WARNING: THE CORDS, WIRES AND/OR CABLES SUPPLIED WITH THIS PRODUCT CONTAIN CHEMICALS, INCLUDING LEAD OR LEAD COMPOUNDS, KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER AND BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM. WASH HANDS AFTER USING.

(CALIFORNIA CODE OF REGULATIONS PROPOSITION 65)

When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:

Read all instructions before using appliance.

IMPORTANT - This portable air purifier has a polarized plug (one blade is wider than the other) as a feature to reduce the risk of electric shock. This plug will fit into a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Never use an extension cord unless the plug can be fully inserted. Do not alter the plug.

To avoid fire or shock hazard, plug the appliance directly into a 120V AC electrical outlet.

Keep the cord out of heavy traffic areas. To avoid fire hazard, NEVER put the cord under rugs, near heat registers, radiator, stoves or heaters.

To protect against electrical hazards, DO NOT immerse in water or other liquids. Do not use near water.

Children cannot recognize the hazards associated with the usage of electrical appliances. For this reason, always supervise children when they are near the unit.

Always unplug the air purifier before moving it, opening the grill, changing filters, cleaning or whenever the air purifier is not in use. Be sure to pull by the plug and not the cord.

NEVER drop or insert any object into any openings.

DO NOT run cord under carpeting.

DO NOT cover cord with throw rugs, runners, or similar coverings.

DO NOT route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.

DO NOT operate any appliance with a damaged cord or plug, if motor fan fails to rotate, after the appliance malfunctions, or if it has been dropped or damaged in any manner. Call Customer Service at 1.866.603.5900 for assistance.

Use appliance only for intended household use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons.

DO NOT use outdoors.

READ AND SAVE THESE INSTRUCTIONS

WARNINGS

Failure to comply with the warnings listed below may result in electric shock or serious injury.

NEVER block the air openings, grills/outlets or place on a soft surface such as a bed or sofa, as this could cause the unit to tip over, blocking the air intake or outtake opening.

DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. The inside of the unit contains no user serviceable parts. All servicing should be performed by qualified personnel only.

DO NOT place anything on top of unit.

WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.

LAMP CONTAINS MERCURY

Manage in accordance with Spills, Disposal and Site Cleanup Requirements. In case of breakage, follow clean-up procedures provided by contacts below.

www.epa.gov/cflcleanup

1-866-284-4010

E-2

E-3

PRODUCT SPECIFICATIONS AND PARTS

SPECIFICATIONS

MODEL NUMBER: AC4100

DIMENSIONS: 7.50L x 6.43W x 10.95H

WEIGHT: 5.05 pounds

INPUT VOLTAGE: 120V 60Hz 0.56 Amps

REPLACEMENT FILTER: Filter E (FLT4100)

REPLACEMENT BULB: LB4100

BULB: 2W

PARTS

Rear View

 

 

 

 

 

Air Outlet

 

 

O

 

 

 

P

Filter Reminder

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PA

 

MAY

 

 

 

 

 

 

 

 

EC JAN FE

 

 

 

 

 

 

 

NO

V

D

 

BM

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

T

 

 

 

A

Date Wheel

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

S

 

 

R

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

 

UG

JUL JUN

 

 

 

 

 

 

 

 

 

 

 

 

 

Rear Cover

 

 

Power Cord

 

 

Air Inlet

 

 

Power & Variable

II

I

Speed Control

 

 

UV-C Control

4 Felt pads

COMBINATION FILTER:

1 Pre-Filter/Charcoal

1 HEPA Filter

Filters last approximately 6-8 months depending on use.

Filters are accessed by

Bulb is accessed by

removing rear cover.

removing rear cover

Pre-Filter/Charcoal

(see page E-9).

 

 

UV-C Bulb

99% HEPA Filter

 

DIGITAL AIR CLEANING SYSTEM

Improve your indoor air quality with your new 3-in-1 Air Cleaning System. Multiple levels of cleaning work together to capture allergens, kill germs and remove odors.

COMBINATION FILTER

PRE-FILTER/CHARCOAL

This layer serves as a pre-filter for capturing large dust particles; lint and pet hair which helps extend the life of your filter. The activated carbon absorbs household and pet odors.

HEPA FILTER

Captures 99% of dust and allergens.

UV-C LIGHT

The power of UV-C light kills bacteria and viruses, including: rhinovirus, E. coli and streptococcus.

AIR CLEANING LAYERS

Rear Cover

Pre-Filter/Charcoal

99% HEPA Filter

UV-C Metal Shield with Ti02

UV-C Bulb

Main Unit

E-4

E-5

DIRECTIONS FOR USE

SET UP

1.Select a firm, level and flat location for the air purifier. For proper air flow, locate the unit at least 1 foot from any wall or furniture. Make sure none of the grills are blocked.

2.Carefully remove your air purifier from box and bag.

3.Determine preferred position of purifier based on space and preference.

Vertical Position

Horizontal Position

4.Adhere 4 felt pads to unit base to protect table top surface. Remove adhesive backing and apply one pad to each corner of unit base depending on preferred position in Step 3 (Figure 1).

Figure 1

OPERATING THE AIR PURIFIER

1.Plug the power cord into a 120V AC outlet.

2.Turn unit power ON.

• Select fan speed MODE 1 - 3

(I = lowest speed setting;

III= highest speed setting)

3.Select UV-C ON or OFF using UV-C Power Button (Figure 2).

Power & Variable

Speed Control

 

 

I

 

 

I

 

I

I

 

I

 

 

UV-C Control

Figure 2

CLEANING & MAINTENANCE

GENERAL CLEANING

Always unplug the unit before cleaning or servicing in any way.

Caution: Do NOT use gasoline, benzine, thinner, harsh cleaners, etc. on and/or in the unit while cleaning as they will damage the product. NEVER use alcohol or other solvents.

Note: Do NOT stick any foreign objects or your fingers inside the unit.

1.Wipe the surface of the unit with a clean, dry soft cloth as needed.

2.Clean the Filter monthly with the brush of your vacuum cleaner.

3.Remove and Clean (or Replace) Filter.

a.Lift and remove the Rear Cover from the unit.

c.Separate and clean both filter layers with the brush attachment of your vacuum cleaner to remove lint and dust.

IMPORTANT: Do NOT try to wash and re-use the Combination Filter.

b.Remove Combination Filter from unit. Note: Pre-Filter/Charcoal is affixed to HEPA Filter with Velcro.

d.Insert Combination Filter into the unit with the HEPA portion facing into the unit. Consult the arrow on the filter for correct installation direction.

IMPORTANT: Do NOT try to wash and re-use the Combination Filter. Please contact Customer Service at 1.866.603.5900 or visit us at www.guardiantechnologies.com to purchase a replacement filter.

Replacement Combination Filter: E (FLT4100)

E-6

E-7

CLEANING & MAINTENANCE

e.Reattach the Rear Cover of the unit and securely latch into place.

FILTER REPLACEMENT

To maintain the performance of the air cleaner, it is recommended that the filter be replaced about every 6 months. The replacement requirements will vary depending on usage and environmental conditions.

1.It’s time to replace the filter when the white HEPA cartridge portion has changed from white to grey or black.

OR

2.A filter date wheel is also built into the rear of the unit

to track your filter changes. Simply set the wheel 6 months ahead from when it is replaced as a reminder. The wheel is marked with the months of the year (Figure 3).

 

 

 

 

C JAN F

 

 

 

 

E

E

 

 

V

D

 

 

B

 

 

 

 

 

A

 

O

 

 

 

 

M

N

 

 

 

 

R

T

 

 

 

 

 

A

C

 

 

 

 

 

P

O

 

 

 

 

 

R

 

 

 

 

 

 

P

 

 

 

Y

S

 

 

 

A

E

 

 

 

 

A

 

N

M

 

U

 

 

 

G JUL JU

 

 

Figure 3

CLEANING & MAINTENANCE

UV-C BULB REPLACEMENT

N FEB

MAR

A

SEP

AUG J

1. Lift and remove the

2. After removing the Rear

Rear Cover from the unit.

Cover from the unit, remove

 

the Combination Filter.

3.After removing the Combination Filter, use a Philips head screwdriver

to remove screw and detach the UV-C Shield.

4.The UV-C Bulb is removed by carefully grasping the bulb with a clean cloth or tissue and pulling the bulb straight out of the unit (Figure 4).

IMPORTANT: The UV-C Bulb should be replaced every 10-12 months depending on use. Please contact Customer Service at 1.866.603.5900 or visit us at www.guardiantechnologies.com to purchase a replacement bulb.

Replacement UV-C Bulb: LB4100

Pull UV-C Bulb straight out of unit.

Figure 4

5. The UV-C Bulb is reinstalled by sliding it, horizontally, back into the slots.

E-8

E-9

TROUBLESHOOTING GUIDE

PROBLEM

SOLUTION

Unit does not operate.

Check that the unit is plugged in.

 

Call Customer Service 1.866.603.5900.

 

 

Unit shuts off unexpectedly.

Check that the unit is plugged into a working

 

electrical outlet.

 

Check that the HEPA Filter is firmly in place.

 

Check that the Front Cover is latched firmly in place.

 

Call Customer Service 1.866.603.5900.

No air circulating from unit.

Unplug unit. Check Pre-Filter/Charcoal and HEPA Filters.

 

Clean Pre-Filter/Charcoal if necessary.

 

Replace HEPA Filter if necessary.

 

 

Increase in noise level.

Make sure the filters are clean. Replace if necessary.

 

 

An unpleasant odor is emitted

Make sure the filters are clean. Replace if necessary.

from the unit.

 

 

 

AIR CLEANING SYSTEM

REPLACEMENT PARTS

Replacement Combination

Replacement UV-C Bulb: LB4100

Filter E: (FLT4100)

 

Please contact Customer Service at 1.866.603.5900 or visit us at

www.guardiantechnologies.com to purchase a replacement filter.

Replacement Combination Filter: E (FLT4100)

LIMITED WARRANTY

To the consumer, Guardian Technologies LLC warrants this product to be free of defects in materials or workmanship commencing upon the date of the original purchase. Save your original sales

receipt to validate start of warranty period. Warranty is not valid without receipt.

If this product should become defective within the warranty period, we will repair or replace any defective parts free of charge. All warranty repairs must be completed by Guardian Technologies LLC. This warranty does not cover unauthorized repairs. The warranty does not include unusual wear, damage resulting from accident, or unreasonable use of the product. This warranty only covers the product when used with genuine Guardian Technologies accessories. This warranty covers product that was purchased from authorized distributors. This warranty gives you specific legal rights and you may also have other rights (other rights may vary from state to state in

the U.S.A.)

The product warranty registration can be completed online at www.guardiantechnologies.com. We consider the registration process important to ensuring superior service to our customers, however submitting the warranty registration is optional and does not affect your rights to utilize this warranty according to the conditions stated above. To submit product under warranty the complete machine must be delivered pre-paid to Guardian Technologies LLC. Please include complete information including: the problem, the model number of the product, the day of purchase, and a copy of the original sales receipt along with your name, address, and telephone (email optional). Address returns to the attention of: Customer Service, at the address below. Additional questions or comments can be made toll free to the number listed below.

Guardian Technologies LLC

7700 St. Clair Avenue

Mentor, Ohio 44060 1.866.603.5900

www.guardiantechnologies.com

This product has been tested and complies with the requirements for Federal Communications Commission, Part 18 for Radio/TV/Communication interference. Although tested, it may affect these devices. If the humidifier is found to interfere, separate the device and/or the humidifier. Conduct only the user maintenance found in this manual. Other maintenance and servicing can cause harmful interference and can void the required FCC compliance.

©2007 Guardian Technologies LLC

E-10

E-11

Loading...
+ 12 hidden pages