S.v.p remettre cette instruction à l'utilisateur de la robinetterie!
Entregue estas instrucciones al usario final de la grifería!
Please pass these instructions on to the end user of the fitting!
I
Type #1 19 822
Type #2 19 825
Type #3 19 839
Page 3
II II
Type #1 19 822 Type #2 19 825
Page 4
Please pass these instructions on to the end user of the faucet!
without bypass use with use of integrated
Thermostat trim type #1 (single use)
bypass
Thermostat trim type #2 (integrated two way diverter)
Installation options with different types of trims
1
Page 5
separate volume controls required
Thermostat trim type #3 (high flow)
Installation options with different types of trims
2
Page 6
3
English
General Application
These trims are for use with the GrohFlexTM universal rough-in valve.
Planning of piping is done at the time of the rough installation. 3 different types of thermostat mixers are possible. Observe the possible combinations, see Pages 1 and 2.
Specification
• Integral service stops
• Flow pressure:
- min 1 bar or 14.5 psi
- recommended 1-5 bar or 14.5 – 72.5 psi greater than 5 bar or 72.5 psi, fit pressure reducing valve
• Max. operating pressure 8.5 bar or 125 psi
• Max. test pressure 34.5 bar or 500 psi
• Flow rates at 3 bar or 45 psi
- Type #1 (19 822) and Type #2 (19 825) bottom outlet 24 l/min or 6,3 gpm
top outlet 12 l/min or 3,2 gpm
- Type #3 (19 839) 51 l/min or 14 gpm
• Temperature
- max. (hot water inlet) 80 °C or 180 °F
• Water connection: cold - RH
hot - LH
General preparation
1.Cut of the excess blue box material, see Fig. [1].
2.Seal the rough-in valve, see Fig. [2].
3.Close the integrated service stops, see Fig. [3].
4.Remove flush cap, see Fig. [4].
1
2 3
4
Page 7
4
English
Installation Type #1 and Type #2
Attention for type #1 If both rough-in outlets are used, you have to install a spout with diverter. If only the lower rough-in outlet is used, you have to install a spout without diverter.
Installation
1.Install control unit and secure with screws, see Fig. [5].
2.Close water flow by turning the yoke. The mark (A) must be on top, see Fig. [6].
3.Open the hot and cold integrated service stops, see Fig. [6].
4.While installation observe the right mounting position.
5.For installation of handle parts after adjustment, see Figs. [7] and [8].
If the thermostat has been installed at too great a depth, this can be adjusted by 27mm or 1 1/16“ with an exten sion set (see Page II, ref. No. 47 822).
Adjustment
Temperature setting, see Fig. [9].
• Before the mixer is put into service, if the mixed water temperature measured at the point of discharge varies from the specified temperature set on the thermostat handle.
• After any maintenance operation on the thermostatic cartridge.
Valve is closed with lever (B) in vertical position: Open volume control by turning the lever (B).
1.Measure the temperature of the water emerging with a thermometer.
2.Turn regulation nut (C) until the water emerging has reached a temperature of 38 °C or 100 °F.
Reversed union (hot on right - cold on left). Replace thermostatic cartridge, special cartridge for service is:
Ref. No.: 47 175 (1/2").
5
6
A
8
9
38 °C
100 °F
C
B
7
Page 8
5
English
Installation Type #3
1.Install control unit and secure with screws, see Fig. [5].
2.Open the hot and cold integrated service stops, see Fig. [6].
3.While installation observe the right mounting position.
4.For installation of handle parts after adjustment, see Fig. [7].
Adjustment
Temperature setting, see Fig. [8].
• Before the mixer is put into service, if the mixed water temperature measured at the point of discharge varies from the specified temperature set on the thermostat handle.
• After any maintenance operation on the thermostatic cartridge.
One or more separate volume controls (D) (not supplied) are required to control the water flow, see Fig. [8].
Open volume control by turning the lever (D), see Fig. [8].
1.Measure the temperature of the water emerging with a thermometer.
2.Turn regulation nut (C) until the water emerging has reached a temperature of 38 °C or 100 °F.
Reversed union (hot on right - cold on left). Replace thermostatic cartridge, special cartridge for service is:
Ref. No.: 47 186 (3/4”).
5
6
7
C
D
38 °C
8
100 °F
Page 9
6
English
Type #2 19 825
F
E
B
10b
F
B
Temperature limitation
When in proper calibration, the temperature range is limited to 43 °C or 110 °F. There is a first safety stop at 38 °C or 100 °F. If a higher temperature is desired, one can exceed 38 °C or 100 °F by overriding the safety stop. Press the safety stop button (E).
Operation
Type #1, see Fig. [10a].
Turn lever (F) left or right:
- Select hot or cold water flow. Turn lever (B) to the right:
- Open water outlet as pipeline installation is prepared.
- If a spout with diverter is installed, outlet to bath and showe r is possible.
Type #2, see Fig. [10b]. Turn lever (F) left or right:
- Select hot or cold water flow.
Turn lever (B) left or right:
Open water outlet as pipeline installation is prepared.
- left open to top outlet
- right open to bottom outlet Type #3, see Fig. [10c].
Turn lever (F) left or right:
- Select hot or cold water flow
Type #1 19 822
F
E
B
10a
F
B
Type #3 19 839
F
E
10c
Page 10
7
English
Prevention of frost damage
When the domestic water system is drained, the thermostat mixers must be drained separately, since non-return valves are installed in the hot and cold water connections.
The complete thermostat assembly and non-return valves must be disassembled and removed.
Maintenance
Important note: If the control unit is to be removed from the rough-in for servicing, first close the inlet stops then open the flow control to allow any internal pressure to be released from within the unit.
Inspect and clean all parts, replace if necessary and grease with special valve grease.
Close the integrated service stops!
I. Non return valves, see Figs. [11] and [12].
Install in reverse order.
Open the integrated service stops!
Replacement parts, see page II (* = special accessories).
Care
Instructions for care of this faucet will be found in the Limited Warranty supplement.