Kit Instructions
Inlet Air Filter Kit
For installing an inlet air filter on the InvisiPac® HM25 and HM50 Tank-Free™
Hot Melt Delivery System. For professional use only.
Not approved for use in explosive atmospheres or hazardous locations.
Kit No. 24R707
Important Safety Instructions
Read all warnings and instructions in this
manual and in the InvisiPac system manual.
Save all instructions.
334790B
EN
Qty
Ref. Part Description
1 110224 VALVE, ball, vented 1
2 106148 FILTER, air 1
3 157350 ADAPTER 1
4 155665 UNION, adapter 1
5 167702 FITTING, nipple 1
6 155677 FITTING, union, 90° 1
7 15Y397 FITTING, swivel 90° 1
8 160790 FITTING, nipple, adapter 1
9 --- TAPE, PTFE, thread sealant 1
.

Installation
1. Install the bleed-type vented air shutoff valve and filter at the 1/4 npt female system air inlet.
NOTE: The system must have a bleed-type ball valve
that bleeds pressure downstream when closed. Otherwise, the supplied air will need to be disconnected from
the system whenever the pressure is relieved. The
direction of flow is indicated on the valve. If installed
backwards, the valve will not vent properly.
NOTE: The system must use an air filter with a minimum flow rate of 30 scfm.
2. If using the same air for the applicator(s), install a
tee in the air line before the ball valve. There should
not be anything between the ball valve and the system (except the filter, if installed). See applicator
manual for applicator air pressure requirements,
and use a regulator before the applicator to
decrease air pressure if necessary.
3. Use the optional elbow fittings (6, 7) and pipe nipple
(8) to alter the orientation of the incoming air line, filter, and ball valve.
4. Close the ball valve.
5. Attach a 3/8 in minimum air supply line to the ball
valve.
NOTE: Air supply pressure must be between 80 psi
(550 kPa, 5.5 bar) and 100 psi (690 kPa, 6.9 bar). Recommended pressure is 100 psi (690 kPa, 6.9 bar).
NOTE: If air pressure is expected to drop below (550
kPa, 5.5 bar), use air reservoir kit 16W366 to allow the
system to operate down to 60 psi (414 kPa, 4.1 bar).
Graco Information
For more information about InvisiPac, visit www.InvisiPac.com.
For technical assistance or customer service, call toll free: 1-800-458-2133.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor.
Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
GRACO INC. AND SUBSIDIARIES • P.O. BOX 1441 • MINNEAPOLIS MN 55440-1441 • USA
Copyright 2015, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
Graco reserves the right to make changes at any time without notice.
2ULJLQDOLQVWUXFWLRQV This manual contains English. MM 334790
Graco Headquarters: Minneapolis
International Offices: Belgium, China, Japan, Korea
www.graco.com
Revision B, August, 2015