Goodman A36-00-2R User Manual

4.6 (7)
Goodman A36-00-2R User Manual

Product Specifications

Standard Features

Equipped with a check flowrater for heat pump and cooling operation

Direct-drive, multi-speed motor to permit air volume variation for heating and cooling application needs

Built-in coil with horizontal and vertical thermoplastic drain pans with secondary drains

Rifled aluminum tubing and louvered aluminum fin coils

Built-in filter provision

Power supply entry at top

Low-voltage entry on left side and top

Transformer and blower time delay on all units

Cabinet Features

Fully insulated steel cabinet

Galvanized stucco finish with painted front panels

Accessories

Pre-tested, pre-wired heat kits in 3, 5, 6, 8, 10, 15, 20 kW, single-phase models; featuring electric heat limit control, rust-resistant nickel chromium heating elements and select models with circuit breakers

Permanent washable plastic air filters

(FIL18-32, FIL36-42, FIL48-61)

AR Series

Multi-Position Electric Air Handler

50 Hz, 1½- to 5-Ton

SS-AR50

www.goodmanmfg.com

8/11

Supersedes 3/11

Product Specifications

Specifications

 

A24-00-2R

A36-00-2R

A48-00-2R

A60-00-2R

 

 

 

 

 

Electrical Data

 

 

 

 

Min. Circuit Ampacity 1

1.1/1.1

1.8/1.8

1.8/1.8

4.3/4.3

Max. Overcurrent Protection 2

15/15

15/15

15/15

15/15

Min./Max. VAC

198/264

198/264

198/264

198/264

Blower Motor

 

 

 

 

FLA

0.85

1.4

1.4

3.4

HP

1/8

1/4

1/4

3/4

 

 

 

 

 

Physical Data

 

 

 

 

Blower

 

 

 

 

Diameter

9½” [24.1]

9½” [24.1]

9½” [24.1]

10⅝” [26.9]

Width

6” [15.2]

8” [20.5]

8” [20.5]

10⅝” [26.9]

Coil Drain Connect FPT

¾” [1.9]

¾” [1.9]

¾” [1.9]

¾” [1.9]

Refrigerant Connection

 

 

 

 

Liquid

⅜” [.95]

⅜” [.95]

⅜” [.95]

⅜” [.95]

Suction

¾” [1.9]

¾” [1.9]

⅞” [2.2]

⅞” [2.2]

 

 

 

 

 

Ship Weight

106 lbs. [48.0]

141 lbs. [63.9]

173 lbs. [78.4]

192 lbs. [87.0]

 

 

 

 

 

¹ @220/240V ² @220/240V

[ ] Designates metric equivalents

Airflow Data

Model

Speed

Airflow (CFM [L/s]) Delivered against External Static Pressure (in. WC [Pa])

 

 

 

 

 

.1 [2.5]

.2 [5.0]

.3 [7.5]

.4 [10.0]

.5 [12.5]

 

 

 

 

 

 

 

 

 

A24-00-2R

High

960 [453]

930 [439]

890 [420]

840 [397]

780 [368]

Low

810 [382]

780 [368]

760 [358]

720 [340]

670 [316]

 

 

 

 

 

 

 

 

A36-00-2R

High

1,290 [619]

1,190 [562]

1,100 [519]

970 [458]

810 [382]

Low

1,100 [519]

1,040 [491]

970 [458]

860 [406]

710 [335]

 

 

 

 

 

 

 

 

A48-00-2R

High

1,670 [789]

1,610 [760]

1,500 [708]

1,440 [680]

1,370 [647]

Low

1,310 [619]

1,300 [614]

1,290 [609]

1,280 [604]

1,260 [595]

 

 

 

 

 

 

 

 

A60-00-2R

High

1,830 [864]

1,750 [826]

1,700 [802]

1,610 [760]

1,490 [703]

Low

1,740 [821]

1,660 [783]

1,640 [774]

1,540 [727]

1,420 [670]

 

 

 

 

 

 

 

 

[ ] Designates metric equivalents;Airflow = Liters per second; External Static Pressure = Pascals

 

 

Assumes dry coil with Filter in Place

SCFM Correction for Wet Coil - 4%.

 

 

 

2

www.goodmanmfg.com

SS-AR50

Loading...