® TECHNICAL MANUAL

SSZ 14 SEER

Split System Heat Pumps

Refer to Service Manual RS6200005 for installation, operation, and troubleshooting information.

All safety information must be followed as provided in the Service Manual.

Refer to the appropriate Parts Catalog for part number information.

Models listed on page 3.

This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person.

Copyright © 2006 - 2007, 2009-2010 Goodman Manufacturing Company, L.P.

RT6213005Rev.3

August 2010

PRODUCT IDENTIFICATION

The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information.

S

S Z 14 036 1

A A

Brand Name

G: Goodman

(Standard Feature Set Models)

S: Goodman

(High Feature Set Models)

Product Family

S: Split System

Product Type

C: Condenser R-22

X:CondenserR-410A

H: Heat Pump R-22

Z: Heat Pump R-410A

SEER

SEER Rating

Minor Revision

A: Initial Release

Major Revision

A: Initial Release

Electrical

1:208/230V/60Hz/1ph

3:208/230V/60Hz/3ph

4:460V/60Hz/3ph

Nominal Capacity

018: 1.5 tons 024: 2 tons 030: 2.5 tons 036: 3 tons 042: 3.5 tons 048: 4 tons 060: 5 tons

WARNING

HIGH VOLTAGE!

Disconnect ALL power before servicing or installing this unit. Multiple power

 

sources may be present. Failure to do so may cause property damage, personal

 

injury or death.

 

 

WARNING

Goodman will not be responsible

 

for any injury or property damage

arising from improper service or service procedures. If you install or perform service on this unit, you assume responsibility for any personal injury or property damage which may result. Many jurisdictions require a license to install or service heating and air conditioning equipment.

Installation and repair of this unit WARNING should be performed ONLY by in-

dividuals meeting the requirements of an "entry level technician", at a minimum, as specified by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI). Attempting to install or repair this unit without such background may result in product damage, personal injury or death.

2

PRODUCT IDENTIFICATION

The model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information.

SSZ140181A*

SSZ140241A*

SSZ140301A*

SSZ140361A*

SSZ140421A*

SSZ140481A*

SSZ140601A*

* Indicates minor revision & is not used for order entry or inventory management

WARNING

The United States Environmental Protection Agency (“EPA”) has issued various regulations re-

garding the introduction and disposal of refrigerants introduced into this unit. Failure to follow

 

these regulations may harm the environment and can lead to the imposition of substantial fines.

 

These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office.

 

 

WARNING

Do not connect or use any device

that is not design certified by

 

Goodman for use with this unit.

Serious property damage, personal injury, reduced unit performance and/or hazardous conditions may result from the use of such non-approved devices.

WARNING To prevent the risk of property damage, personal injury, or death,

do not store combustible materials or use gasoline or other flammable liquids or vapors in the vicinity of this appliance.

3

PRODUCT DESIGN

SSZ14 models are available in 1 1/2 through 5 ton sizes and use R-410A refrigerant. They are designed for 208/230 volt single phase applications.

The condenser air is pulled through the condenser coil by a direct drive propeller fan. This condenser air is then discharged out of the top of the cabinet.

These units are designed for free air discharge, so no additional resistance like duct work shall be attached.

The suction and liquid line connections on present models are of the sweat type for field piping with refrigerant type copper. Front seating valves are factory installed to accept the field run copper. The total refrigerant charge for a normal installation is factory installed in the condensing unit. SSZ units are charged for the matching evaporator coil and a 15 foot refrigerant line set.

Systems should be properly sized by heat gain and loss calculations made according to methods of the Air Conditioning Contractors Association (ACCA) or equivalent. It is the contractors responsibility to ensure the system has adequate capacity to heat or cool the conditioned space.

SSZ models use high-efficiency Copeland® scroll "Ultratech" compressors which are specifically desgined for R-410A refrigerant. There are a number of design characteristics which are different from the scroll compared to the traditional reciprocating compressor.

"Ultratech" Series scroll compressors with Copeland® ComfortAlert diagnositics will not have a discharge thermostat. Some of the early model scroll compressors required discharge thermostats.

Due to their design Scroll compressors are inherently more tolerant of small quantities of liquid refrigerant.

NOTE: Even though the compressor section of a Scroll compressor is more tolerant of liquid refrigerant, continued floodback or flooded start conditions may wash oil from the bearing surfaces causing premature bearing failure.

"Ultratech" Series scroll compressors use "POE" or polyolester oil which is NOT compatible with mineral oil based lubricants like 3GS. "POE" oil must be used if additional oil is required.

WARNING

To avoid possible injury, explosion or death, practice safe handling of refrigerants.

Operating pressures and amp draws may differ from standard reciprocating and/or scroll compressors. This information may be found in the "Cooling Performance Data" section.

This unit is for outdoor installation only. Refer to minimum figure for clearances from the sides of the unit to full walls and other objects.

NOTE: This unit cannot be completely enclosed. At least one side must be unrestricted.

These clearances will help avoid air recirculation. If installing two or more units at the same location, allow at least 24 inches between units. If only one side is restricted (for example, against the outside wall of a house), the unit may be placed as close as 8" to that one wall.

DO NOT locate the unit:

*Directly under a vent termination for a gas appliance.

*Within 3 feet of a clothes drier vent

*Where the refreezing of defrost water would create a hazard

*Where water may rise into the unit.

NOT

B

OK!

RECOMMENDED

 

B

A

AA

 

C

 

AA

B

B

 

 

AA

 

C

 

OK!

AA

AA

OK!

OK!OK!

 

 

A AAAA

C

 

C

Minimum Airflow Clearance

 

 

Model Type

 

A

 

B

 

C

AA

 

 

Residential

10"

 

10"

18"

20"

Light Commercial

12"

 

12"

18"

24"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

 

Dimensions - W x D x H

 

 

 

 

 

 

 

 

 

 

 

 

 

SSZ140181A*

 

 

 

29 x

29 x 34¼

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSZ140241A*

 

 

 

29 x

29 x 38¼

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSZ140301A*

 

 

 

29 x

29 x 38¼

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSZ140361A*

 

 

35½ x

35½ x 38¼

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSZ140421A*

 

 

35½ x

35½ x 38¼

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSZ140481A*

 

 

35½ x

35½ x 38¼

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SSZ140601A*

 

 

35½ x

35½ x 38¼

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

HEAT PUMP SPECIFICATIONS

SSZ140[18,30, 342,48,60]1AA-AE; SSZ140241AA-AH; SSZ140361AA-AG

Cooling Capacity, BTUH

Compressor

R.L. Amps

L.R. Amps

Low Pressure Switch

Open

Close

High Pressure Switch

Open

Close

Condenser Fan Motor

Horsepower

F.L. Amps

Liquid Line, Inches O.D.*

Suction Line, Inches O.D.*

Refrigerant Charge

Power Supply

Minimum Circuit Ampacity(1)

Maximum Overcurrent Device(2)

Electrical Conduit Size

Power Supply (Inches)

Approximate Shipping W eight

SSZ140181AA-AE

SSZ140241AA-AH

SSZ140301AA-AE

SSZ140361AA-AG

SSZ140421AA-AE

SSZ140481AA-AE

SSZ140601AA-AE

 

 

 

 

 

 

 

18,000

24,000

30,000

36,000

42,000

48,000

60,000

 

 

 

 

 

 

 

8.97

12.82

14.10

16.67

17.95

19.87

26.41

48.0

58.3

73.0

79.0

112.0

109.0

130.0

22 PSIG

22 PSIG

22 PSIG

22 PSIG

22 PSIG

22 PSIG

22 PSIG

50 PSIG

50 PSIG

50 PSIG

50 PSIG

50 PSIG

50 PSIG

50 PSIG

610 PSIG

610 PSIG

610 PSIG

610 PSIG

610 PSIG

610 PSIG

610 PSIG

420 PSIG

420 PSIG

420 PSIG

420 PSIG

420 PSIG

420 PSIG

420 PSIG

 

 

 

 

 

 

 

1/12

1/6

1/6

1/4

1/4

1/4

1/4

0.6

1.1

1.1

1.5

1.5

1.5

1.5

 

 

 

 

 

 

 

3/8"

3/8"

3/8"

3/8"

3/8"

3/8"

3/8"

3/4"

3/4"

3/4"

7/8"

7/8"

7/8"

7/8"

143.0

163.0

188.0

213.0

213.0

273.0

278.0

 

 

 

 

 

 

 

208/230-60-1

208/230-60-1

208/230-60-1

208/230-60-1

208/230-60-1

208/230-60-1

208/230-60-1

11.80

17.10

18.73

22.40

24.00

26.40

34.60

20

25

30

30

40

40

60

 

 

 

 

 

 

 

1/2 or 3/4

1/2 or 3/4

1/2 or 3/4

1/2 or 3/4

1/2 or 3/4

1/2 or 3/4

1/2 or 3/4

199

207

219

242

242

266

280

 

 

 

 

 

 

 

* Up to 24' in equivalent line length

(1)Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes.

(2)Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.

NOTES:

Always check the S & R plate for electrical data on the unit being installed.

Installer will need to supply 7/8" to 1-1/8" adapters for suction line connections (4 & 5 ton units).

Installer will need to supply 3/4" to 7/8" adapters for suction line connections (3 ton unit).

Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge Procedure.

Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE

OUTDOORUNIT,NOTTHEINDOORCOIL.

NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only.

Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial plate for the most up-to-date general and electrical information.

5

HEAT PUMP SPECIFICATIONS

SSZ140[18,30,42,48,60]1AF; SSZ140241AJ; SSZ140361AH

Cooling Capacity, BTUH

Compressor

R.L. Amps

L.R. Amps

Low Pressure Switch

Open

Close

High Pressure Switch

Open

Close

Condenser Fan Motor

Horsepower

F.L. Amps

Liquid Line, Inches O.D.*

Suction Line, Inches O.D.*

Refrigerant Charge

Power Supply

Minimum Circuit Ampacity(1)

Maximum Overcurrent Device(2)

Electrical Conduit Size

Power Supply (Inches)

Approximate Shipping W eight

SSZ140181AF

SSZ140241AJ

SSZ140301AF

SSZ140361AH

SSZ140421AF

SSZ140481AF

SSZ140601AF

 

 

 

 

 

 

 

18,000

24,000

30,000

36,000

42,000

48,000

60,000

 

 

 

 

 

 

 

9.0

12.82

14.10

16.67

17.95

19.9

26.41

48.0

58.3

73.0

79.0

112.0

109.0

130.0

22 PSIG

22 PSIG

22 PSIG

22 PSIG

22 PSIG

22 PSIG

22 PSIG

50 PSIG

50 PSIG

50 PSIG

50 PSIG

50 PSIG

50 PSIG

50 PSIG

610 PSIG

610 PSIG

610 PSIG

610 PSIG

610 PSIG

610 PSIG

610 PSIG

420 PSIG

420 PSIG

420 PSIG

420 PSIG

420 PSIG

420 PSIG

420 PSIG

 

 

 

 

 

 

 

1/12

1/6

1/6

1/4

1/4

1/4

1/4

0.6

1.1

1.0

1.5

1.5

1.5

1.5

 

 

 

 

 

 

 

3/8"

3/8"

3/8"

3/8"

3/8"

3/8"

3/8"

3/4"

3/4"

3/4"

7/8"

7/8"

7/8"

7/8"

140.0

160.0

185.0

210.0

210.0

270.0

275.0

 

 

 

 

 

 

 

208/230-60-1

208/230-60-1

208/230-60-1

208/230-60-1

208/230-60-1

208/230-60-1

208/230-60-1

11.90

17.10

18.60

22.40

23.90

26.40

34.50

20

25

30

30

40

40

60

 

 

 

 

 

 

 

1/2 or 3/4

1/2 or 3/4

1/2 or 3/4

1/2 or 3/4

1/2 or 3/4

1/2 or 3/4

1/2 or 3/4

199

207

219

242

242

266

280

 

 

 

 

 

 

 

* Up to 24' in equivalent line length

(1)Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes.

(2)Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.

NOTES:

Always check the S & R plate for electrical data on the unit being installed.

Installer will need to supply 7/8" to 1-1/8" adapters for suction line connections (4 & 5 ton units).

Installer will need to supply 3/4" to 7/8" adapters for suction line connections (3 ton unit).

Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge

Procedure.

Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE

OUTDOORUNIT,NOTTHEINDOORCOIL.

NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/ circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only.

6

 

 

 

 

 

 

 

 

 

 

EXPANDED PERFORMANCE DATA

 

 

COOLING OPERATION

 

MODEL: SSZ140181A* / CA*F3131*6A* +TXV / MBR800**-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Am bie nt Te m perature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

 

 

 

75

 

 

 

85

 

 

 

95

 

 

105

 

 

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ente ring Indoor We

t Bulb Tem pe rature

 

 

 

 

 

 

 

 

 

 

 

 

IDB*

Airflow

 

59

63

 

67

71

59

63

 

67

71

59

63

 

67

71

59

63

 

67

71

59

63

67

71

59

63

67

71

 

 

 

 

 

MBh

17.6

18.3

 

20.0

-

17.2

17.9

 

19.6

-

16.8

17.4

 

19.1

-

16.4

17.0

 

18.6

-

15.6

16.2

17.7

-

14.4

15.0

16.4

-

 

 

 

 

 

S/T

0.74

0.62

0.43

-

0.76

0.64

0.44

-

0.78

0.65

0.45

-

0.81

0.67

0.47

-

0.84

0.70

0.49

-

0.85

0.71

0.49

-

 

 

 

 

 

Delta T

18

15

12

-

18

16

12

-

18

16

12

-

18

16

12

-

18

15

12

-

17

14

11

-

 

 

 

 

675

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

1.17

1.19

1.23

-

1.25

1.28

1.32

-

1.33

1.36

1.40

-

1.40

1.43

1.47

-

1.45

1.48

1.53

-

1.50

1.53

1.58

-

 

 

 

 

 

AMPS

4.2

4.3

4.4

-

4.5

4.6

4.8

-

4.9

5.0

5.2

-

5.3

5.4

5.6

-

5.6

5.7

5.9

-

5.9

6.1

6.3

-

 

 

 

 

 

HI PR

213

229

242

-

239

257

271

-

271

292

308

-

309

333

351

-

348

374

395

-

384

413

436

-

 

 

 

 

 

LO PR

107

113

124

-

113

120

131

-

117

124

136

-

123

131

143

-

129

137

150

-

133

142

155

-

 

 

 

 

 

MBh

17.1

17.7

19.4

-

16.7

17.3

19.0

-

16.3

16.9

18.5

-

15.9

16.5

18.1

-

15.1

15.7

17.2

-

14.0

14.5

15.9

-

 

 

 

 

 

S/T

0.70

0.59

0.41

-

0.73

0.61

0.42

-

0.75

0.62

0.43

-

0.77

0.64

0.45

-

0.80

0.67

0.46

-

0.81

0.67

0.47

-

 

 

 

 

 

Delta T

18

16

12

-

19

16

12

-

19

16

12

-

19

16

12

-

19

16

12

-

17

15

11

-

 

 

 

70

600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

1.16

1.18

1.22

-

1.24

1.27

1.31

-

1.32

1.35

1.39

-

1.38

1.41

1.46

-

1.44

1.47

1.52

-

1.49

1.52

1.57

-

 

 

 

 

 

AMPS

4.2

4.3

4.4

-

4.5

4.6

4.8

-

4.9

5.0

5.2

-

5.2

5.3

5.5

-

5.5

5.7

5.9

-

5.9

6.0

6.2

-

 

 

 

 

 

HI PR

210

227

239

-

236

254

268

-

269

289

305

-

306

329

348

-

344

370

391

-

380

409

432

-

 

 

 

 

 

LO PR

105

112

122

-

111

119

129

-

116

123

134

-

122

129

141

-

127

136

148

-

132

140

153

-

 

 

 

 

 

MBh

15.8

16.4

17.9

-

15.4

16.0

17.5

-

15.1

15.6

17.1

-

14.7

15.2

16.7

-

14.0

14.5

15.9

-

12.9

13.4

14.7

-

 

 

 

 

 

S/T

0.68

0.57

0.39

-

0.70

0.59

0.41

-

0.72

0.60

0.42

-

0.74

0.62

0.43

-

0.77

0.64

0.45

-

0.78

0.65

0.45

-

 

 

 

 

 

Delta T

19

16

12

-

19

16

12

-

19

16

12

-

19

17

13

-

19

16

12

-

18

15

12

-

 

 

 

 

525

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

1.13

1.15

1.19

-

1.21

1.24

1.28

-

1.29

1.31

1.35

-

1.35

1.38

1.42

-

1.41

1.44

1.48

-

1.45

1.48

1.53

-

 

 

 

 

 

AMPS

4.1

4.2

4.3

-

4.4

4.5

4.6

-

4.7

4.9

5.0

-

5.1

5.2

5.4

-

5.4

5.5

5.7

-

5.7

5.8

6.0

-

 

 

 

 

 

HI PR

204

220

232

-

229

247

260

-

261

280

296

-

297

319

337

-

334

359

379

-

369

397

419

-

 

 

 

 

 

LO PR

102

109

119

-

108

115

126

-

112

119

130

-

118

126

137

-

124

132

144

-

128

136

149

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

17.9

18.5

20.0

21.5

17.5

18.0

19.5

21.0

17.1

17.6

19.1

20.5

16.7

17.2

18.6

20.0

15.9

16.3

17.7

19.0

14.7

15.1

16.4

17.6

 

 

 

 

 

S/T

0.84

0.75

0.57

0.36

0.87

0.78

0.59

0.38

0.89

0.80

0.60

0.39

0.92

0.82

0.62

0.40

0.95

0.85

0.65

0.42

0.96

0.86

0.65

0.42

 

 

 

 

 

Delta T

20

19

15

11

21

19

16

11

21

19

16

11

21

19

16

11

21

19

16

11

19

18

15

10

 

 

 

 

675

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

1.18

1.20

1.24

1.27

1.26

1.29

1.33

1.37

1.34

1.37

1.41

1.46

1.41

1.44

1.48

1.53

1.46

1.50

1.54

1.59

1.51

1.55

1.60

1.65

 

 

 

 

 

AMPS

4.2

4.3

4.5

4.6

4.6

4.7

4.8

5.0

5.0

5.1

5.2

5.4

5.3

5.4

5.6

5.8

5.6

5.8

6.0

6.2

6.0

6.1

6.3

6.5

 

 

 

 

 

HI PR

215

231

244

255

241

259

274

286

274

295

311

325

312

336

355

370

351

378

399

416

388

418

441

460

 

 

 

 

 

LO PR

108

114

125

133

114

121

132

141

118

126

137

146

124

132

144

154

130

138

151

161

135

143

156

166

 

 

 

 

 

MBh

17.4

17.9

19.4

20.8

17.0

17.5

19.0

20.3

16.6

17.1

18.5

19.9

16.2

16.7

 

18.1

19.4

15.4

15.8

17.2

18.4

14.3

14.7

15.9

17.1

 

 

 

 

 

S/T

0.80

0.71

0.54

0.35

0.83

0.74

0.56

0.36

0.85

0.76

0.57

0.37

0.88

0.78

 

0.59

0.38

0.91

0.81

0.62

0.40

0.92

0.82

0.62

0.40

 

 

 

 

 

Delta T

21

20

16

11

22

20

16

11

22

20

16

11

22

20

 

16

11

21

20

16

11

20

18

15

10

 

 

 

75

600

KW

1.17

1.19

1.23

1.26

1.25

1.28

1.32

1.36

1.33

1.36

1.40

1.44

1.40

1.43

 

1.47

1.52

1.45

1.48

1.53

1.58

1.50

1.53

1.58

1.64

 

 

 

 

 

AMPS

4.2

4.3

4.4

4.6

4.5

4.6

4.8

5.0

4.9

5.0

5.2

5.4

5.3

5.4

 

5.6

5.8

5.6

5.7

5.9

6.1

5.9

6.1

6.3

6.5

 

 

 

 

 

HI PR

213

229

242

252

239

257

271

283

271

292

308

322

309

333

 

351

366

348

374

395

412

384

413

437

455

 

 

 

 

 

LO PR

107

113

124

132

113

120

131

139

117

124

136

145

123

131

 

143

152

129

137

150

159

133

142

155

165

 

 

 

 

 

MBh

16.1

16.5

17.9

19.2

15.7

16.2

17.5

18.8

15.3

15.8

 

17.1

18.3

15.0

15.4

 

16.7

17.9

14.2

14.6

15.8

17.0

13.2

13.5

14.7

15.7

 

 

 

 

 

S/T

0.77

0.69

0.52

0.34

0.80

0.71

0.54

0.35

0.82

0.73

 

0.55

0.36

0.84

0.76

 

0.57

0.37

0.88

0.78

0.59

0.38

0.88

0.79

0.60

0.39

 

 

 

 

 

Delta T

22

20

16

11

22

20

17

11

22

20

 

17

11

22

20

 

17

12

22

20

16

11

20

19

15

11

 

 

 

 

525

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

1.14

1.16

1.20

1.24

1.22

1.25

1.29

1.33

1.30

1.32

 

1.37

1.41

1.36

1.39

 

1.44

1.48

1.42

1.45

1.49

1.54

1.47

1.50

1.54

1.60

 

 

 

 

 

AMPS

4.1

4.2

4.3

4.5

4.4

4.5

4.7

4.8

4.8

4.9

 

5.1

5.2

5.1

5.2

 

5.4

5.6

5.4

5.6

5.7

6.0

5.7

5.9

6.1

6.3

 

 

 

 

 

HI PR

206

222

234

244

231

249

263

274

263

283

 

299

312

300

323

 

341

355

337

363

383

400

373

401

423

442

 

 

 

 

 

LO PR

103

110

120

128

109

116

127

135

113

121

 

132

140

119

127

 

138

147

125

133

145

155

129 137 150 160

 

 

 

Shaded

area is

ACCA (TVA) conditions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

IDB: Entering Indoor Dry Bulb Temperature

 

KW=Total system pow er

 

 

 

 

AMPS=outdoor unit amps (comp.+fan

DATA PERFORMANCE COOLING

SSZ140181A*

8

 

 

 

 

 

 

 

 

 

EXPANDED PERFORMANCE DATA

 

 

COOLING OPERATION

MODEL: SSZ140181A* / CA*F3131*6A* +TXV / MBR800**-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Am bient Tem perature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

 

 

 

75

 

 

 

85

 

 

 

95

 

 

105

 

 

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Entering Indoor Wet Bulb Tem perature

 

 

 

 

 

 

 

 

 

 

IDB*

Airflow

 

59

63

 

67

71

59

63

 

67

71

59

63

 

67

71

59

63

 

67

71

59

63

67

71

59

63

67

71

 

 

 

MBh

18.3

18.7

 

19.9

21.3

17.8

18.2

 

19.5

20.8

17.4

17.8

 

19.0

20.3

17.0

17.4

 

18.5

19.8

16.1

16.5

17.6

18.8

14.9

15.3

16.3

17.4

 

 

 

S/T

0.92

0.86

0.70

0.52

0.95

0.89

0.73

0.54

1.00

0.92

0.75

0.56

1.00

0.94

0.77

0.57

1.00

1.00

0.80

0.60

1.00

1.00

0.80

0.60

 

 

 

Delta T

23

22

19

15

23

22

19

15

24

22

19

15

23

22

19

16

22

22

19

15

20

21

18

14

 

 

675

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

1.19

1.21

1.25

1.28

1.27

1.30

1.34

1.38

1.35

1.38

1.42

1.47

1.42

1.45

1.50

1.54

1.48

1.51

1.56

1.61

1.53

1.56

1.61

1.66

 

 

 

AMPS

4.3

4.4

4.5

4.7

4.6

4.7

4.9

5.1

5.0

5.1

5.3

5.5

5.3

5.5

5.7

5.9

5.7

5.8

6.0

6.2

6.0

6.2

6.4

6.6

 

 

 

HI PR

217

233

247

257

243

262

277

288

277

298

315

328

315

339

358

374

355

382

403

420

392

422

445

465

 

 

 

LO PR

109

116

126

134

115

122

133

142

119

127

139

148

125

133

146

155

131

140

153

162

136

145

158

168

 

 

 

MBh

17.7

18.1

19.4

20.7

17.3

17.7

18.9

20.2

16.9

17.3

18.5

19.7

16.5

16.8

 

18.0

19.2

15.7

16.0

17.1

18.3

14.5

14.8

15.8

16.9

 

 

 

S/T

0.88

0.82

0.67

0.50

0.91

0.85

0.69

0.52

0.93

0.87

0.71

0.53

0.96

0.90

 

0.73

0.55

1.00

0.94

0.76

0.57

1.00

0.94

0.77

0.57

 

 

 

Delta T

24

23

20

16

24

23

20

16

24

23

20

16

24

23

 

20

16

24

23

20

16

22

21

19

15

 

80

600

KW

1.18

1.20

1.24

1.27

1.26

1.29

1.33

1.37

1.34

1.37

1.41

1.46

1.41

1.44

 

1.48

1.53

1.46

1.50

1.54

1.59

1.51

1.55

1.60

1.65

 

 

 

AMPS

4.2

4.3

4.5

4.6

4.6

4.7

4.8

5.0

5.0

5.1

5.3

5.4

5.3

5.4

 

5.6

5.8

5.6

5.8

6.0

6.2

6.0

6.1

6.3

6.5

 

 

 

HI PR

215

231

244

255

241

259

274

286

274

295

311

325

312

336

 

355

370

351

378

399

416

388

418

441

460

 

 

 

LO PR

108

114

125

133

114

121

132

141

118

126

137

146

124

132

 

144

154

130

138

151

161

135

143

156

166

 

 

 

MBh

16.4

16.7

17.9

19.1

16.0

16.3

17.4

18.6

15.6

15.9

17.0

18.2

15.2

15.6

 

16.6

17.8

14.5

14.8

15.8

16.9

13.4

13.7

14.6

15.6

 

 

 

S/T

0.84

0.79

0.64

0.48

0.88

0.82

0.67

0.50

0.90

0.84

0.69

0.51

0.93

0.87

0.71

0.53

0.96

0.90

0.73

0.55

0.97

0.91

0.74

0.55

 

 

 

Delta T

24

23

20

16

24

23

20

16

25

23

20

16

25

24

21

16

24

23

20

16

23

22

19

15

 

 

525

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

1.15

1.17

1.21

1.24

1.23

1.26

1.30

1.34

1.31

1.34

1.38

1.42

1.37

1.40

1.45

1.49

1.43

1.46

1.51

1.56

1.48

1.51

1.56

1.61

 

 

 

AMPS

4.1

4.2

4.4

4.5

4.5

4.6

4.7

4.9

4.8

4.9

5.1

5.3

5.2

5.3

5.5

5.7

5.5

5.6

5.8

6.0

5.8

5.9

6.1

6.4

 

 

 

HI PR

208

224

237

247

234

252

266

277

266

286

302

315

303

326

344

359

341

367

387

404

376

405

428

446

 

 

 

LO PR

104

111

121

129

110

117

128

136

115

122

133

142

120

128

140

149

126

134

147

156

131

139

152

161

 

DATA PERFORMANCE COOLING

 

 

MBh

18.6

18.9

19.8

21.2

18.1

18.5

19.4

20.7

17.7

18.1

18.9

20.2

17.3

17.6

18.4

19.7

16.4

16.7

17.5

18.7

15.2

15.5

16.2

17.3

 

 

 

S/T

0.96

0.93

0.84

0.68

1.00

0.96

0.87

0.71

1.00

0.99

0.89

0.72

1.00

1.00

0.92

0.75

1.00

1.00

0.95

0.77

1.00

1.00

0.96

0.78

 

 

 

Delta T

24

24

23

20

25

24

23

20

24

24

23

20

24

24

23

20

22

23

23

20

21

21

21

18

 

 

675

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

1.19

1.22

1.26

1.29

1.28

1.31

1.35

1.39

1.36

1.39

1.43

1.48

1.43

1.46

1.51

1.56

1.49

1.52

1.57

1.62

1.54

1.57

1.62

1.68

 

 

 

AMPS

4.3

4.4

4.6

4.7

4.7

4.8

4.9

5.1

5.1

5.2

5.3

5.5

5.4

5.5

5.7

5.9

5.7

5.9

6.1

6.3

6.1

6.2

6.4

6.7

 

 

 

HI PR

219

236

249

260

246

265

279

291

280

301

318

331

318

343

362

377

358

386

407

425

396

426

450

469

 

 

 

LO PR

110

117

127

136

116

123

135

143

121

128

140

149

127

135

147

157

133

141

154

164

137

146

159

170

 

 

 

MBh

18.0

18.4

19.3

20.5

17.6

18.0

18.8

20.1

17.2

17.5

18.4

19.6

16.8

17.1

17.9

19.1

15.9

16.2

17.0

18.2

14.8

15.0

15.8

16.8

 

 

 

S/T

0.92

0.89

0.80

0.65

0.95

0.92

0.83

0.67

0.98

0.94

0.85

0.69

1.00

0.97

0.88

0.71

1.00

1.00

0.91

0.74

1.00

1.00

0.92

0.74

 

 

 

Delta T

25

25

24

20

26

25

24

21

26

25

24

21

26

25

24

21

24

25

24

21

23

23

22

19

 

85

600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

1.19

1.21

1.25

1.28

1.27

1.30

1.34

1.38

1.35

1.38

1.42

1.47

1.42

1.45

1.50

1.54

1.48

1.51

1.56

1.61

1.53

1.56

1.61

1.66

 

 

 

AMPS

4.3

4.4

4.5

4.7

4.6

4.7

4.9

5.1

5.0

5.1

5.3

5.5

5.3

5.5

5.7

5.9

5.7

5.8

6.0

6.2

6.0

6.2

6.4

6.6

 

 

 

HI PR

217

233

247

257

243

262

277

288

277

298

315

328

315

339

358

374

355

382

403

420

392

422

445

465

 

 

 

LO PR

109

116

126

134

115

122

133

142

119

127

139

148

125

133

146

155

131

140

153

162

136

145

158

168

 

 

 

MBh

16.6

17.0

17.8

19.0

16.3

16.6

17.4

18.5

15.9

16.2

16.9

18.1

15.5

15.8

16.5

17.6

14.7

15.0

15.7

16.8

13.6

13.9

14.5

15.5

 

 

 

S/T

0.89

0.85

0.77

0.63

0.92

0.89

0.80

0.65

0.94

0.91

0.82

0.66

0.97

0.94

0.85

0.69

1.00

0.97

0.88

0.71

1.00

0.98

0.89

0.72

 

 

 

Delta T

26

25

24

21

26

26

24

21

26

26

24

21

26

26

24

21

26

26

24

21

24

24

23

20

 

 

525

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

1.16

1.18

1.22

1.25

1.24

1.27

1.31

1.35

1.32

1.35

1.39

1.43

1.38

1.41

1.46

1.51

1.44

1.47

1.52

1.57

1.49

1.52

1.57

1.62

 

 

 

AMPS

4.2

4.3

4.4

4.6

4.5

4.6

4.8

4.9

4.9

5.0

5.2

5.3

5.2

5.3

5.5

5.7

5.5

5.7

5.8

6.1

5.9

6.0

6.2

6.4

 

 

 

HI PR

210

226

239

249

236

254

268

280

269

289

305

318

306

329

348

362

344

370

391

408

380

409

432

451

 

 

 

LO PR

105

112

122

130

111

118

129

138

116

123

134

143

122

129

141

150

127

136

148

158

132

140

153

163

 

Shaded area is ARI Rating Conditions

 

 

 

IDB: Entering Indoor Dry Bulb Temperature

 

KW=Total system pow er

 

 

 

 

AMPS=outdoor unit amps (comp.+fan

SSZ140181A*

 

 

 

 

 

 

 

 

 

 

EXPANDED PERFORMANCE DATA

 

 

COOLING OPERATION

 

MODEL: SSZ140241A* / CA*F3636*6A*+TXV / MBR800**-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Am bient Tem perature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

65

 

 

 

 

75

 

 

 

85

 

 

 

95

 

 

 

105

 

 

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Entering Indoor Wet Bulb Tem perature

 

 

 

 

 

 

 

 

 

 

 

IDB*

Airflow

 

59

63

 

67

71

59

63

 

67

71

59

63

 

67

71

59

63

 

67

 

71

59

63

67

71

59

63

67

71

 

 

 

 

MBh

23.5

24.4

 

26.7

-

23.0

23.8

 

26.1

-

22.4

23.2

 

25.5

-

21.9

22.7

 

24.8

 

-

20.8

21.5

23.6

-

19.3

20.0

21.9

-

 

 

 

 

S/T

0.75

0.63

 

0.44

-

0.78

0.65

0.45

-

0.80

0.67

0.46

-

0.83

0.69

0.48

 

-

0.86

0.72

0.50

-

0.87

0.72

0.50

-

 

 

 

 

Delta T

17

15

 

11

-

17

15

11

-

17

15

11

-

17

15

11

 

-

17

15

11

-

16

14

11

-

 

 

 

956

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

1.65

1.68

 

1.73

-

1.77

1.80

1.86

-

1.87

1.91

1.97

-

1.97

2.01

2.07

 

-

2.04

2.09

2.15

-

2.11

2.16

2.22

-

 

 

 

 

AMPS

10.1

10.2

 

10.4

-

10.5

10.7

10.9

-

11.0

11.2

11.4

-

11.5

11.7

11.9

 

-

12.0

12.2

12.4

-

12.4

12.6

12.9

-

 

 

 

 

HI PR

222

239

 

252

-

249

268

283

-

283

305

322

-

323

347

367

 

-

363

391

412

-

401

432

456

-

 

 

 

 

LO PR

110

117

 

128

-

116

124

135

-

121

129

140

-

127

135

147

 

-

133

142

155

-

138

146

160

-

 

 

 

 

MBh

22.8

23.7

 

25.9

-

22.3

23.1

25.3

-

21.8

22.6

24.7

-

21.2

22.0

24.1

 

-

20.2

20.9

22.9

-

18.7

19.4

21.2

-

 

 

 

 

S/T

0.72

0.60

 

0.42

-

0.74

0.62

0.43

-

0.76

0.64

0.44

-

0.79

0.66

0.46

 

-

0.82

0.68

0.47

-

0.83

0.69

0.48

-

 

 

 

 

Delta T

18

15

 

12

-

18

16

12

-

18

16

12

-

18

16

12

 

-

18

15

12

-

17

14

11

-

 

 

70

850

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

1.64

1.67

 

1.72

-

1.75

1.79

1.84

-

1.86

1.90

1.95

-

1.95

1.99

2.05

 

-

2.03

2.07

2.14

-

2.09

2.14

2.21

-

 

 

 

 

AMPS

10.0

10.1

 

10.3

-

10.5

10.6

10.8

-

11.0

11.1

11.4

-

11.4

11.6

11.9

 

-

11.9

12.1

12.3

-

12.3

12.5

12.8

-

 

 

 

 

HI PR

220

236

 

250

-

247

265

280

-

280

302

319

-

319

344

363

 

-

359

387

408

-

397

427

451

-

 

 

 

 

LO PR

109

116

 

127

-

115

122

134

-

120

127

139

-

126

134

146

 

-

132

140

153

-

136

145

158

-

 

 

 

 

MBh

21.1

21.8

 

23.9

-

20.6

21.3

23.4

-

20.1

20.8

22.8

-

19.6

20.3

22.3

 

-

18.6

19.3

21.1

-

17.3

17.9

19.6

-

 

 

 

 

S/T

0.69

0.58

 

0.40

-

0.72

0.60

0.42

-

0.74

0.62

0.43

-

0.76

0.63

0.44

 

-

0.79

0.66

0.46

-

0.80

0.66

0.46

-

 

 

 

 

Delta T

18

16

 

12

-

18

16

12

-

18

16

12

-

18

16

12

 

-

18

16

12

-

17

15

11

-

 

 

 

744

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

1.60

1.63

 

1.68

-

1.72

1.75

1.80

-

1.82

1.85

1.91

-

1.90

1.94

2.00

 

-

1.98

2.02

2.08

-

2.04

2.09

2.15

-

 

 

 

 

AMPS

9.8

10.0

 

10.2

-

10.3

10.4

10.6

-

10.8

11.0

11.2

-

11.2

11.4

11.7

 

-

11.7

11.9

12.1

-

12.1

12.3

12.6

-

 

 

 

 

HI PR

213

229

 

242

-

239

257

272

-

272

293

309

-

310

333

352

 

-

349

375

396

-

385

414

438

-

 

 

 

 

LO PR

106

112

 

123

-

112

119

130

-

116

123

135

-

122

130

142

 

-

128

136

148

-

132

141

153

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MBh

23.9

24.6

 

26.7

28.6

23.4

24.1

26.0

27.9

22.8

23.5

25.4

27.3

22.2

22.9

24.8

 

26.6

21.1

21.8

23.6

25.3

19.6

20.2

21.8

23.4

 

 

 

 

S/T

0.86

0.77

 

0.58

0.37

0.89

0.79

0.60

0.39

0.91

0.81

0.62

0.40

0.94

0.84

0.64

 

0.41

0.98

0.87

0.66

0.42

0.98

0.88

0.67

0.43

 

 

 

 

Delta T

20

18

 

15

10

20

18

15

10

20

18

15

10

20

19

15

 

10

20

18

15

10

19

17

14

10

 

 

 

956

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

1.66

1.70

 

1.75

1.80

1.78

1.82

1.87

1.93

1.89

1.93

1.99

2.05

1.98

2.02

2.09

 

2.15

2.06

2.10

2.17

2.24

2.13

2.17

2.24

2.32

 

 

 

 

AMPS

10.1

10.2

 

10.4

10.7

10.6

10.7

10.9

11.2

11.1

11.3

11.5

11.8

11.6

11.8

12.0

 

12.3

12.0

12.2

12.5

12.8

12.5

12.7

13.0

13.3

 

 

 

 

HI PR

224

241

 

255

266

252

271

286

298

286

308

325

339

326

351

370

 

386

367

395

417

435

405

436

460

480

 

 

 

 

LO PR

111

118

 

129

138

117

125

136

145

122

130

142

151

128

136

149

 

159

134

143

156

166

139

148

161

172

 

 

 

 

MBh

23.2

23.9

 

25.9

27.8

22.7

23.4

25.3

27.1

22.1

22.8

24.7

26.5

21.6

22.2

 

24.1

 

25.8

20.5

21.1

22.9

24.5

19.0

19.6

21.2

22.7

 

 

 

 

S/T

0.82

0.73

 

0.55

0.36

0.85

0.76

0.57

0.37

0.87

0.78

0.59

0.38

0.90

0.80

 

0.61

 

0.39

0.93

0.83

0.63

0.41

0.94

0.84

0.63

0.41

 

 

 

 

Delta T

21

19

 

15

11

21

19

16

11

21

19

16

11

21

19

 

16

 

11

21

19

16

11

19

18

15

10

 

 

75

850

KW

1.65

1.68

 

1.73

1.78

1.77

1.80

1.86

1.92

1.87

1.91

1.97

2.03

1.97

2.01

 

2.07

 

2.13

2.04

2.09

2.15

2.22

2.11

2.16

2.22

2.30

 

 

 

 

AMPS

10.1

10.2

 

10.4

10.6

10.5

10.7

10.9

11.1

11.0

11.2

11.4

11.7

11.5

11.7

 

11.9

 

12.2

12.0

12.2

12.4

12.7

12.4

12.6

12.9

13.2

 

 

 

 

HI PR

222

239

 

252

263

249

268

283

295

283

305

322

336

323

347

 

367

 

382

363

391

412

430

401

432

456

475

 

 

 

 

LO PR

110

117

 

128

136

116

124

135

144

121

129

140

150

127

135

 

147

 

157

133

142

155

165

138

146

160

170

 

 

 

 

MBh

21.4

22.1

 

23.9

25.6

20.9

21.6

23.3

25.0

20.4

21.0

 

22.8

24.4

19.9

20.5

 

22.2

 

23.8

18.9

19.5

21.1

22.7

17.5

18.1

19.6

21.0

 

 

 

 

S/T

0.79

0.70

 

0.53

0.34

0.82

0.73

0.55

0.36

0.84

0.75

 

0.57

0.36

0.86

0.77

 

0.58

 

0.38

0.90

0.80

0.61

0.39

0.90

0.81

0.61

0.39

 

 

 

 

Delta T

21

19

 

16

11

21

19

16

11

21

19

 

16

11

21

20

 

16

 

11

21

19

16

11

20

18

15

10

 

 

 

744

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KW

1.61

1.64

 

1.69

1.74

1.73

1.76

1.82

1.87

1.83

1.87

 

1.92

1.98

1.92

1.96

 

2.02

 

2.08

2.00

2.04

2.10

2.17

2.06

2.10

2.17

2.24

 

 

 

 

AMPS

9.9

10.0

 

10.2

10.4

10.3

10.5

10.7

10.9

10.9

11.0

 

11.2

11.5

11.3

11.5

 

11.7

 

12.0

11.8

11.9

12.2

12.5

12.2

12.4

12.7

13.0

 

 

 

 

HI PR

215

232

 

245

255

242

260

275

286

275

296

 

312

326

313

337

 

356

 

371

352

379

400

417

389

419

442

461

 

 

 

 

LO PR

107

114

 

124

132

113

120

131

140

117

125

 

136

145

123

131

 

143

 

152

129

137

150

160

133

142

155

165

 

9

Shaded area is ACCA (TVA) conditions

 

 

 

IDB: Entering Indoor Dry Bulb Temperature

 

KW=Total system pow er

 

 

 

 

AMPS=outdoor unit amps (comp.+fan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DATA PERFORMANCE COOLING

SSZ140241A*

Loading...