Genie GPOWER 900, 900, 1200-1500, TRILOG 1200-1500, SC 1200-1500 User Manual

...
0 (0)

GARAGE DOOR OPENER MODELS

PowerMax® 1200/1500, SC 1200/1500, TriloGTM 1200/1500, PowerLift® 900, GPowerTM 900,

SilentMax® 1000/1200, CB 1000/1200, IntelliG® 1000/1200

SCREW/BELT/CHAIN DRIVES

OPERATION & MAINTENANCE MANUAL

Includes INTELLICODE 2 Remote Control. Safe-T-Beam

®

System must be installed to close door.

®

 

For use only with residential sectional or one piece overhead garage doors.

Homelink ® and Car2U® compatible.

Need help or have questions? DO NOT RETURN to the store. Call us: 800-354-3643

For Answers and Assistance: 1.800.354.3643

or visit www.geniecompany.com

SAVE THIS MANUAL FOR FUTURE REFERENCE

INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER

WARNING

To reduce the risk of injury to persons or damage to property – Use this opener only with a one-piece or sectional door.

Genie, Genie logo, Intellicode, Safe-T-Beam, IntelliG, PowerMax, PowerLift, ChainMax and SilentMax are registered trademarks TriloG and GPower are trademarks of GMI Holdings, Inc., dba The Genie Company Homelink is a registered trademark of Johnson Controls Technology Company. Car2U is a registered trademark of Lear Corporation. ©The Genie Company 2012 PN#38209501773, 9/2012

38209501773

TRANSMITTER COMPLIANCE STATEMENT

Transmitters comply with all United States and Canadian legal requirements as of the date of manufacture. No warranty is made that they comply with all legal requirements of any other jurisdiction. If transmitters are to be used in another country, the importer must determine compliance with any local laws and regulations which may differ from United States and Canadian requirements prior to use.

Los transmisores cumplen con todas las reglamentaciones legales de los Estados Unidos y del Canadá, en la fecha de fabricación. Ninguna garantía se da que cumplan con todas las reglamentaciones legales de ninguna otra jurisdicción. Si los transmisores se van a utilizar en otro país, el importador debe determinar si cumplen con las reglamentaciones y leyes locales que puedan ser diferentes a las reglamentaciones de los Estados Unidos y del Canadá, antes de usar los mismos.

Les émetteurs sont conformes à la réglementation américaine et canadienne à compter de leur date de fabrication. Aucune garantie n’est stipulée indiquant qu’ils sont conformes à toutes les prescriptions juridiques d’autres autorités. Si les émetteurs sont utilisés dans d’autres pays, il incombe à l’importateur d’en déterminer leur conformité aux lois et règles locales pouvant différer de celles des États-Unis et du Canada avant toute utilisation desdits émetteurs.

Sendegeräte entsprechen allen gesetzlichen Bestimmungen in den USA und Kanada zum Zeitpunkt der Herstellung Wir übernehmen keine Gewährleistung für die Einhaltung aller gesetzlichen Bestimmungen in anderen Ländern. Sollen Sendegeräte in anderen Ländern eingesetzt

werden, so muss der Importeur vor dem Gebrauch sicherstellen, dass die Sendegeräte auch solchen lokalen Bestimmungen entsprechen, welche von den Bestimmungen der USA und Kanadas abweichen.

Need help or have questions? Call us:

800-354-3643. DO NOT RETURN to the store.

2

 

Table of Contents

 

1

Safety Information

 

 

Safety Notifications...........................................

3

 

Important Safety Instructions............................

3

 

Infrared Protection Function..............................

3

2

Features

 

 

Safety...............................................................

4

 

Opener.............................................................

4

3

Required Programming

 

 

Introduction......................................................

5

 

Overview of Powerhead Controls.......................

5

 

Travel Limits

 

 

Closing Garage Door (DOWN Limits).............

6

 

Opening Garage Door (UP Limits)..................

7

 

Wall Console Overview......................................

8

 

Series III Wall Consoles with Black Buttons...

8

 

Series II Wall Consoles with White Buttons....

8

 

Force and Speed Control..............................

9

 

Contact Reverse Test....................................

9

 

Remotes/New Intellicode 2 Openers................

10

4

Optional Programming

 

 

Keypad...........................................................

12

 

Clearing Memory for Remotes.........................

13

 

Intellicode 1 Remotes.....................................

14

5

One Piece Doors

 

 

Attaching Door Bracket to Door.......................

15

 

Attaching Door Arm to Door Bracket................

15

6

Maintenance and Adjustments

 

 

Maintenance Safety........................................

16

 

Regular Maintenance......................................

16

 

Corrective Maintenance..................................

17

 

Adjustment Guides..........................................

18

7

Wiring Diagram..................................................

20

8

Troubleshooting..................................................

21

9

Warranty.............................................................

23

SAVE THESE INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS

G999-393 Manual-ScrewBeltChain-EN indd 2

7/13/12 10 17 AM

1

Safety Information

OVERVIEW OF POTENTIAL HAZARDS

READ THIS SAFETY INFORMATION

CONVENTIONS USED IN THESE INSTRUCTIONS

Garage doors are large, heavy objects that move with the help of springs under high tension and electric motors. Since moving objects, springs under tension, and electric motors can cause injuries, your safety and the safety of others depend on you reading the information in this manual. If you have questions or do not understand the information presented, call your nearest trained door system technician or visit our website at www.geniecompany.com

The following safety alert symbol and signal words are used throughout this manual to call a of hazard and special instructions.

This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.

All safety messages will follow the safety alert symbol and the word “DANGER”, “ WARNING”, or “CAUTION”.

DANGER indicates an imminently hazardous situation which, if NOT avoided, will result in death or serious injury.

WARNING indicates a potentially hazardous situation which, if NOT avoided, could result in death or serious injury.

CAUTION indicates a potentially hazardous situation which, if NOT avoided, may result in injury or property damage.

The word NOTE is used to indicate important steps to be followed or important considerations.

IMPORTANT SAFETY INSTRUCTIONS

Potential

 

 

Hazard

Effect

Prevention

 

 

 

 

 

 

 

 

WARNING

Keep people clear of opening

 

 

 

 

 

 

Could result

while door is moving.

 

 

 

in Death

DO NOT allow children to play

 

 

 

or Serious

 

 

 

Injury

with the door opener.

 

 

 

 

DO NOT operate a door that

 

 

 

 

jams or one that has a

 

 

 

 

broken spring.

 

 

 

WARNING

Turn OFF power before

 

 

 

Could result

removing opener cover.

 

 

 

in Death

 

 

 

 

or Serious

When replacing cover, make

 

 

 

Injury

sure wires are NOT pinched or

 

 

 

 

near moving parts.

 

 

 

 

Opener must be fully

 

 

 

 

grounded.

 

 

 

WARNING

DO NOT try to remove, install,

 

 

 

Could result

repair or adjust springs or

 

 

 

in Death

anything to which door spring

 

 

 

or Serious

parts are fastened, such as,

 

 

 

Injury

wood blocks, steel brackets,

 

 

 

 

cables or other like items.

 

 

 

 

Installations, repairs and

 

 

 

 

adjustments must be done

 

 

 

 

by a trained door system

 

 

 

 

technician, using proper tools

 

 

 

 

and instructions.

 

 

 

 

 

IMPORTANT INSTALLATION INSTRUCTIONS

WARNING

TO REDUCE THE RISK OF SEVERE INJURY OR DEATH

READ AND FOLLOW ALL SAFETY, INSTALLATION AND OPERATION INSTRUCTIONS. If you have any questions or do not understand an instruction, call The Genie® Company or your local Genie® Factory Authorized Dealer.

DO NOT install operator on an improperly balanced door. An improperly balanced door could cause severe injury. Repairs and adjustments to cables, spring assembly, and other hardware must be made by a trained service person using proper tools and instructions.

Remove all ropes, and disable all locks connected to the door before installing operator.

• Where possible,

r. For products having an emergency release, mount the emergency

release within reach, but a

avoiding contact with vehicles to avoid accidental release.

DO NOT connect the operator to the source of power until instructed to do so.

Locate the wall console button: A) Within sight of door. B) At a minimum height of 5 feet so small children cannot reach it. C) Away from all moving parts of the door.

Install the entrapment WARNING label next to the wall button or console, in a prominent location. Install the emergency release tag on, or next to, the emergency release handle.

• The opera

at the center of the doorway. This is about the size

at.

3

2 Features

Begin here onlY after completing assembly and installation of the opener. Review the Assembly and Installation poster to ensure all steps have been performed.

Contact your Genie® Professional Dealer for an installation poster, if needed, or call 1-800-35GENIE. You may also visit www.geniecompany.com to download a PDF file.

SAFETY FEATURES

Safe-T-Beam® (STB) Non-Contact Reversing System

Puts an invisible beam across the door opening. The door stops and reverses to the full open position if anything passes through the beam. LED indicator lights on the powerhead and on the STBs provide a self-diagnostic code if an operational problem exists.

Safe-T-Reverse® Contact Reversing System

Automatically stops and reverses a closing door within two seconds of contact with an object.

Automatic ForceGuardControl

Automatically sets the force required to fully open and close the door for maximum safety.

Watch DogMonitoring System

Monitors the Safe-T-Beam® system to ensure proper functionality and will automatically stop and reverse a closing door if a problem

is detected.

Manual Emergency Release

Manually releases door from door opener. Used during a power failure or other emergency to allow manual opening and closing of door.

SmartSet™ Electronic Programming

Easily adjust the programming to reduce opening speed to a desired rate, vary limits and force, and program new remotes.

Automatic Lighting System

Two bulb lighting system supplies light for safer evening exits and entries. Turns ON when door is activated and automatically turns OFF 4 minutes later.

Integrated Motion Detection (Not available on all models)

Some units have motion detection built into the

powerhead. Lights automatically turn ON when

motion is detected for much safer movement through the garage. Lights will turn OFF after 4 minutes of no motion.

4

opener features

INTELLICODE® 2 Access Security System

A new generation superior encryption system that enhances the security of the door opener by continuously changing the access code each time the remote is used. The door opener responds to each new code only once. An access code copied from a working system and tried again, will not control the door opener.

Wall Console

Operates door opener from inside garage. The wall console has an indicator light with: Open/Close, Sure-Lock, and independent light control buttons.

Home Link and Car2U® compatible. Refer to the programming instructions on page 11.

NOTE: Use this manual ONLY after completing assembly and installation of opener. Review Assembly/Installation Instructions poster. Check that all steps have been completed.

Contact your Genie® Professional Dealer for an

Assembly/Installation Instructions poster, if needed, or call 1-800-35GENIE. You can also go to www.geniecompany.com to download a printable file.

INFRARED PROTECTION FUNCTION

1.The Safe-T-Beam® has no effect on the door during an opening cycle.

2.If the Safe-T-Beam® detects an obstruction when trying to close the door, it will not allow the door to close.

3.When the garage door is closing, if Safe-T-Beam® is interrupted by a person or obstacle, the garage door will stop its downward travel and reverse automatically to its fully opened position.

4.If the Safe-T-Beam® System fails, loses power, or is installed improperly, press and hold the wall console “open/close” button until the door reaches its fully closed position. If you release the “open/close” button on the wall console during the closing movement, the door will reverse automatically to its fully-opened position.

G999-393 Manual-ScrewBeltChain-EN indd 4

7/13/12 10 17 AM

3 Required Programming

NOTE: Before you begin programming, check to make sure there are no objects in the garage door opening.

INTRODUCTION

Now that your Genie garage door opener is installed, you will want to program the opener so that the door opens and closes properly and all remote devices operate correctly. The following steps guide you through setting your opener so it functions properly for you.

The following information will take you through programming your opener’s functional settings for use.

There are only 2 “required” programming processes you will need to follow to set up your garage door opener for operation:

1.“TRAVEL LIMITS”

2.“REMOTE PROGRAMMING”

Term Definitions:

Travel Limits programming allows you to set how far your door travels up or down in opening and closing your garage door.

Remote Programming synchronizes your remote control devices (remotes, wall console, and keypad) with the powerhead.

Force Control refers to how much power is needed to move (open/ close) your particular door and does NOT require programming.

Speed Control refers to how fast or slow your opener opens and closes your particular door and is preset at the factory. This function does NOT require programming.

Overview of PoWERHEAD Controls

This section describes the programming functions on the powerhead of the opener. Use the following information to familiarize yourself with the buttons, LED indicators and products used to program functions.

Powerhead: There are 3 programming buttons and 2 LED lights on the powerhead. Each of the buttons is used to enter and complete the setup programming. The LED lights indicate status or a function change by illuminating ON, OFF, or ON FLASHING in one of three different colors: blue, red or purple.

There are 4 programs (The 2 “Factory Set” programs are unlikely to need changes.)

1.Door Travel Limits Program

This program is used to set how far your door travels up and down.

2.Remote Programs (Default menu)

These show you how to program your remotes to synch with additional remote control devices, wall consoles, keypads, and the powerhead.

3.Door Force Program (Factory Set)

This program is only used for minor adjustments under certain circumstances.

4.Door Speed Program (Factory Set)

This program does not require manually initiated changes.

NOTE: The 3 programming buttons are for programming ONLY. These buttons should NOT be used to operate the opener once the Required Programming section has been successfully completed.

ROUND LED

Close Travel

Open Travel

Indicator

Button

PROGRAM

 

 

SET

+

LONG LED

Indicator

Located on bottom of Powerhead.

PROGRAM

 

Enters into and selects programming menus.

 

SET

 

Multi-function; move door during programming

+ and advance through menus

 

5

G999-393 Manual-ScrewBeltChain-EN indd 5

7/13/12 10 17 AM

3

Required Programming

 

 

TRAVEL LIMITS

 

 

 

 

WARNING

3

Release down arrow button (-) and the long LED

• Make sure doorway is in view and clear of obstacles and

 

will begin flashing.

 

 

 

 

people to avoid injury or damage to property.

 

PROGRAM

 

• DO NOT operate this unit from wall console before LIMITS

 

 

are set. Severe damage to the opener can occur.

 

 

 

• The shuttle MUST be engaged to carriage BEFORE setting limits.

 

 

 

See Installation Poster (if provided) or call Customer Service at

 

SET

+

1-800-35GENIE or visit www.geniecompany.com

 

NOTE: If shuttle/bullet has NOT been engaged to carriage, do so now. See page 17.

NOTE: Before setting limits confirm wall console red indicator light (or backlight) is ON. If not illuminated, check for correct wiring or the Sure-Lock switch may be activated.

Closing Garage Door (Down Limits)

1

Lift the door open by hand until the shuttle/bullet

 

engages the carriage on the rail.

 

1

1

2

 

2

Press and hold the down arrow button (-) for

 

2 seconds until the long LED comes on blue

 

(round LED remains off).

PROGRAM

 

PROGRAM

SET

+

SET

 

HOLD

 

 

2 seconds

 

6

 

 

G999-393 Manual-ScrewBeltChain-EN indd

6

 

4

Press and hold the down arrow button (-) until

 

garage door is fully closed on floor, then release.

 

PROGRAM

 

 

SET

+

 

 

HOLD

 

PROGRAM

 

 

SET

+

NOTE: You have 30 seconds to execute each step. If you see two solid red or flashing LEDs on the Powerhead, you have run out of time and must go back to the beginning of the step and start over. You can restart as many times as necessary to complete each step.

(continued next page)

7/13/12 1017 AM

Genie GPOWER 900, 900, 1200-1500, TRILOG 1200-1500, SC 1200-1500 User Manual

3 Required Programming

5

Press and release the Program Set button (both

8

Press and hold the up arrow button (+) until door

 

LEDs flash blue and go off).

 

 

is fully open, then release. Watch carriage as

 

 

 

 

 

it approaches the power head to avoid contact

 

PROGRAM

 

PROGRAM

 

with powerhead.

 

 

 

 

 

 

 

 

 

 

 

PROGRAM

 

 

 

+

 

 

 

 

 

 

 

 

SET

 

 

 

 

 

 

HOLD

The DOWN (closed) limit is programmed.

 

 

 

Opening Garage Door (Up Limits)

 

 

 

NOTE: Beginning with garage door closed is recommended but not

 

 

 

necessary.

 

 

 

 

 

6

Press and hold the up arrow button (+) for

 

 

 

 

2 seconds until the long LED light comes on blue

 

 

 

 

(round LED remains off).

 

 

 

 

 

PROGRAM

 

PROGRAM

 

 

 

 

 

 

 

PROGRAM

 

 

SET

SET

 

 

 

 

 

 

HOLD

 

 

 

 

 

2 seconds

 

SET

 

 

 

 

 

7

Release up arrow button (+) and the round LED

 

 

 

 

will begin flashing.

 

9

 

 

 

 

 

 

Press and release the Program Set button (both

 

 

PROGRAM

 

 

LEDs flash blue and go off).

 

 

 

 

 

 

 

 

 

 

 

 

PROGRAM

PROGRAM

 

 

SET

 

 

 

– +

 

The UP (open) limit is programmed.

 

BOTH DOOR LIMITS ARE NOW PROGRAMMED.

 

7

G999-393 Manual-ScrewBeltChain-EN indd 7

7/13/12 10 17 AM

3 Required Programming

Wall Console / Overview

This opener has a serial

MODEL AC SR3

THE GENIE COMPANY

number sticker in which

FCC ID: B8Q AC SR3

Residential Door Operator

IC: 2 33A-CS 1D

120V. 60HZ. 5A

the serial numbers begin

S/N:10XXXX XXXXXXX

 

with 10 or higher.

 

 

 

 

 

 

Wall consoles from other manufacturers may not work with openers of these serial number groups. Use only the wall console provided with this unit. Each wall console has three buttons.

In your carton you will find one of the following wall consoles:

Series II Wall Consoles with White Buttons

Indicator Light

Large white button will display Red when wall console is properly wired and Sure-Lock is OFF. When Sure-Lock is ON, this light is off

Open/Close Button

Use this button to open or close garage door. When Sure-Lock™ is ON, the Open/Close button will CLOSE the door only.

NoTE: Constant button pressure in the CLOSE mode will override STB fault in the powerhead and close door.

Independent Light Control Button

Use this button to turn powerhead lights ON. Powerhead lighting will remain ON until this button is pressed again or a door action has been completed.

NoTE: If opener has a Motion Detector sensor, it will keep powerhead lights ON as long as motion is detected.

Sure-Lock Button

When Sure-Lock is ON, the powerhead cannot be activated by the wall console or a remote.

Press and release (or until red light goes off) to activate Sure-Lock.

Press and release to turn Sure-Lock OFF.

Open/Close Button

 

Opens and closes door from inside garage.

 

Indicator Light

 

–Red indicator backlight is ON.

To powerhead

–When Sure-Lock™ is

 

ON, the indicator light is OFF

 

Sure-Lock™ Button

 

– LOCK disables controls after

 

door is completely closed.

B/W

 

W

– UNLOCK allows controls to

 

work normally.

 

Independent Light Control Button

Controls door opener lights from inside garage.

8

Series III Wall Consoles with Black Buttons

Indicator Light

Indicator light will display Red when wall console is properly wired and Sure-Lock is OFF. When Sure-Lock is ON, indicator light flashes.

Open/Close Button

Use this button to open or close garage door. When Sure-Lock™ is ON, the Open/Close button will CLOSE the door only.

NoTE: Constant button pressure in the CLOSE mode will override STB fault in the powerhead and close door.

Independent Light Control Button

Use this button to turn powerhead lights ON. Powerhead lighting will remain ON until this button is pressed again or a door action has been completed.

NoTE: If opener has a Motion Detector sensor, it will keep powerhead lights ON as long as motion is detected.

Sure-Lock Button

When Sure-Lock is ON, the powerhead cannot be activated by the wall console or a remote.

Press and hold for 5 seconds (or until Indicator Light flashes) to activate Sure-Lock.

Press and release to turn Sure-Lock OFF.

Open/Close Button

Opens and closes door from inside garage.

Indicator Light

 

–Red indicator light is

To powerhead

always ON.

–When Sure-Lock™ is ON,

 

the indicator light flashes.

 

Sure-Lock™ Button

 

– LOCK disables controls

 

after door is completely

W

closed.

B/W

– UNLOCK allows controls to

 

work normally.

 

Independent Light Control Button

Controls door opener lights from inside garage.

TIP

FROM STBs

FROM WALL

WALL CONSOLE

CONSOLE

NOT NOT

USED USED

 

 

 

STB

BWC

IWC

STB

BWC

IWC

 

 

 

 

 

 

G999-393 Manual-ScrewBeltChain-EN indd 8

7/13/12 10 17 AM

Loading...
+ 16 hidden pages