SPLIT TYPE
AIR CONDITIONER
CASSETTE
Models Indoor unit Outdoor unit
AUG30FUAR AOG30FNBWL
AUG30UUAR AOG30UNBWL
type (50Hz)
2005.07.29
CONTENTS
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
REFRIGERANT SYSTEM DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . .4
CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
ERROR CONTENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
INDOOR PRINTED CIRCUIT BOARD CIRCUIT DIAGRAM . . . . .8
OUTDOOR PRINTED CIRCUIT BOARD CIRCUIT DIAGRAM . .10
DISASSEMBLY ILLUSTRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
STANDARD ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
SPECIFICATIONS
TYPE COOLING COOLING & HEATING
INDOOR UNIT
OUTDOOR UNIT
COOLING CAPACITY (kW) 8.40 8.40
HEATING CAPACITY (kW) ------- 9.50
ELECTRICAL DATA
POWER SOURCE (V) 230
FREQUENCY (Hz) 50
RUNNING
CURRENT
INPUT WATTS (kW)
E.E.R. (kW/kW)
STARTING CURRENT (A) 70
MOISTURE REMOVAL ( /hr) 3.0
COOLING 13.6 13.6
(A)
HEATING ------- 13.1
COOLING 2.95 2.95
HEATING ------- 2.78
COOLING 2.85 2.85
HEATING ------- 3.42
COMPRESSOR
TYPE
DISCRIMINATION 5JS330DAE01
REFRIGERANT R410A (g) 2,300
AUG30FUAR AUG30UUAR
AOG30FNBWL AOG30UNBWL
Hermetic type, 2 poles, Single phase,
Induction motor, Rotary
HIGH 560 C 560 H 540
FAN SPEED LOW 390 C 390 H 390
(r.p.m.) S-LOW 250 C 250 H 250
AIR FLOW
DIMENSIONS
H x W x D (mm)
WEIGHT
NET / GROSS (kg) OUTDOOR 68 / 74 69 / 75
MAX PIPE LENGTH / HEIGHT (m) 30 / 15
REMOTE CONTROLLER TYPE WIRED
INDOOR
OUTDOOR HI / LO 780 / 400
INDOOR 1,250
(m3/h)
OUTDOOR 3,300
INDOOR 246 x 830 x 830
GRILLE 35 x 940 x 940
OUTDOOR 830 x 900 x 330
INDOOR 34 / 44
MED 480 C 480 H 480
ADDITIONAL REFRIGERANT CHARGE (R410A)
PIPE LENGTH 7.5 m 2,300 g 2,300 g
FULL CHARGE
AMOUNT
ADDITIONAL CHARGE 20 g / m 40 g / m
10 m 2,350 g 2,400 g
20 m 2,550 g 2,800 g
30 m 2,750 g 3,200 g
- 1 -
2005.07.29
REFRIGERANT SYSTEM DIAGRAM
Models :AUG30FUAR / AOG30FNBWL
OUTDOOR UNIT
Condenser
THo
Compressor
Strainer
Pressure
Check Valve
Accumulator
Capillary
Tube
INDOOR UNIT
Refrigerant pipe
15.88mm(5/8")
Charging
Valve
Evaporator
Refrigerant pipe
9.52mm(3/8")
Models :AUG30UUAR / AOG30UNBWL
OUTDOOR UNIT
Pressure
Check Valve
4-Way
Muffler
Condenser
Strainer
Valve
Compressor
Capillary
Tube
INDOOR UNIT
Refrigerant pipe
15.88mm(5/8")
Charging
Valve
Accumulator
Evaporator
Strainer
2005.07.29
Refrigerant pipe
9.52mm(3/8")
: Cool
: Heat
- 4 -
Model :
AUG30UUA R
INDOOR UNIT
Model :
AOG30UNBWL
OUTDOOR UNIT
COMPRESSOR
SR
RED
COMPRESSOR
CAPACITOR
BLACK
FUSE
GRAY
C
C M
BLACK
INTERNAL
OVERLOAD
PROTECTOR
WHITE
WHITE
WHITE
1NL23
THERMAL
PROTECTOR
15
RELAY
46
RED
BLACK
TERMINAL
F M
FAN MOTOR
FAN MOTOR
CAPACITOR
RED
RED
WHITE
BLACK
1364
BLUE
1364
RED
WHITE
BLACK
YELLOW
YELLOW
GRAY
GRAY
21
21
4321
7531
21
21
GRAY
BLACK
21
21
BLACK
BROWN
21
21
BROWN
BLACK
13
21
BLACK
THERMISTOR
(PIPE TEMP.)
THERMISTOR
(OUTDOOR TEMP.)
THERMISTOR
(DISCHARGE TEMP.)
4WV
SOLENOID COIL
BLACK
13
21
21
21
3
51
21
3
BLACK
RED
21
21
RED
21
21
BELT HEATER
PRINTED CIRCUIT BOARD
PURPLE
31
21
PURPLE
TRANSFORMER
2005.07.29
TO POWER SUPPLY
TO INDOOR
UNIT
FUSE
- 6 -
ERROR CONTENTS
(1) Stop the air conditioner operation.
(2) Press the master control button and the fan control button simultane-
ously for 2 seconds or more to start the test run.
Test run display
(3) Press the start/stop button to stop the test run.
[SELF-DIAGNOSIS]
When the error indication E:EE is displayed, follow the following items
to perform the self-diagnosis. E:EE indicates an error has occurred.
1. REMOTE CONTROLLER DISPLAY
1) Stop the air conditioner operation.
2) Press the set temperature buttons simultaneously for 5 seconds or more to start the self-diagnosis.
Refer to the following tables for the description of each error code.
Unit number (usually 0)
Error code
SUMOTUWETH FR
SA
Ex. Self-diagnosis
(3) Press the set temperature buttons simultaneously for 5 sec-
onds or more to stop the self-diagnosis.
Error code Error contents
00
01
02
03
04
05
06
07
08
09
0A
0b
0c
0d
0E
0F
11
12
13
14
Communication error
(indoor unit remote controller)
Communication error
(indoor unit outdoor unit)
Room temperature sensor open
Room temperature sensor short-circuited
Indoor heat exchanger temperature sensor open
Indoor heat exchanger temperature sensor shortcircuited
Outdoor heat exchanger temperature sensor open
Outdoor heat exchanger temperature sensor shortcircuited
Power source connection error
Float switch operated
Outdoor temperature sensor open
Outdoor temperature sensor short-circuited
Discharge pipe temperature sensor open
Discharge pipe temperature sensor short-circuited
Outdoor high pressure abnormal
Discharge pipe temperature abnormal
Model abnormal
Indoor fan abnormal
Outdoor signal abnormal
Outdoor EEPROM abnormal
2. OUTDOOR UNIT LEDS
When the outdoor temperature drops, the outdoor units fans may switch
to low speed.
ERROR : HEAT & COOL MODEL (REVERSE CYCLE) ONLY
The LED lamps operate as follows according to the error contents.
Error display
LED1 LED2
0.1 sec.
ON
OFF
Quick flash continued Quick flash continued
0.5 sec.
ON
OFF
1 quick flash repeated Lighting continued
ON
OFF
2 quick flash repeated Lighting continued
ON
OFF
3 quick flash repeated Lighting continued
4 quick flash repeated Lighting continued Outdoor temperature
5 quick flash repeated Lighting continued
6 quick flash repeated Lighting continued Indoor unit error
7 quick flash repeated Lighting continued Discharge temperature
8 quick flash repeated Lighting continued
When the fault is cleared, the LED lamp goes off.
However, for discharge pipe temperature abnormal and high pressure
abnormal, the LED lamp lights continuously for 24 hours, as long as the
power is not turned off.
2 sec.
0.5 sec.
2 sec.
0.5 sec.
2 sec.
ON
OFF
ON
OFF
ON
OFF
ON
OFF
0.1 sec.
Error contents
Model abnormal or
EEPROM abnormal
Power source
connection error
Discharge temperature sensor error
Outdoor heat
exchanger temperature sensor error
sensor error
Communication signal error
abnormal
High pressure abnormal
- 7 -
2005.07.29