General ARHA36LU, ARHA36LATU, AOHA36LATL, ARHA45LU, ARHA45LATU, AOHA45LATL Technical Manual
R410A
INDOOR UNIT
1. DUCT
AR A36LATU
AR A45LATU
TYPE :
D2D_AR031E/01
2007.09.01
1. FEATURE
MODEL :
DUCT TYPE
AR A36LATU / AO A36LATL
AR A36-45L
DUCT TYPE
AR A36-45L
AR A45LATU / AO A45LATL
FEATURES
Energy saving
High energy saving was realized by making the indoor unit and outdoor
unit fan motor and compressor all DC and optimal design of the refrigerant cycle. Rank A was achieved in European energy rank.
Installation styles
Embedded in Ceiling
Hanging from Ceiling
Slim & compact design
In the case of bottom suction type, as seen from lower rear part.
Control Box united with main unit
One-touch operating and easy-to-install
long-life filter (optional)
In addition to the slim height of 270 mm which is our sales point, further compactification is attained by reducing 65 mm from the width with the flanking
control box embedded inside the chassis.
- (01 - 01) -
Easy maintenance
DUCT TYPE
AR A36-45L
In the case of rear suction type, as seen from lower rear part.
1
4
1.Control box
2.Fan casing
3.Fan
DUCT TYPE
AR A36-45L
4.Motor
2
3
Bottom panel: 2 units
The motor and fan maintenance and dismounting can be made easily by removing
the rear panel and lower part of the casing with the main chassis installed.
Quiet operation
Quiet operation at *29dB(A) possible by quiet mode.
* See our measurement conditions page (01-19).
Static pressure mode setting
Air flow, noise, etc. can be used under the optimum conditions by selecting
the static pressure mode matched to the installation conditions.
Room temperature adjustment correction
Suitable room temperature control is performed by changing the room temperature correction value by simple remote control operation to match the
conditions under which the air conditioner is installed.
Auto restart
The units restart automatically when the current was returned even when
there was a power interruption during operation.
- (01 - 02) -
2. REMOTE CONTROLLER
WIRED REMOTE CONTROLLER
DUCT TYPE
AR A36-45L
FEATURES
Various timer setup (ON / OFF / WEEKLY) are possible.
Equipped with weekly timer as standard function.
(2 times Start / Stop per day for a week)
When setting up a timer, operation mode and a temperature
setup can be changed.
When a failure occurs,the error code is displayed. (Maximum of 16)
Error indication.(A maximum of 16 error histories are memorizable.)
Up to 16 indoor units can be simultaneously controlled.
Economy operation are possible.
Easy installation with a slim shape with no bulge in the back.
The room temperature can be controlled by being detected the temperature
accurately with built-in thermo sensor.
Simple function setting
Setting of the air conditioner selection function is performed by remote controller.
DUCT TYPE
AR A36-45L
High performance and compact size
Three functions are combined in
one unit.
Wired
remote
controller
Built-in timers
Possible to set ON/OFF time to operate twice each day
of the week.
SUMOTUWETH FR SA
7
3126 9
15 18 21
Setup screen example
(Set to Wednesday: 8:00 to 20:00.)
0 3 6 9 12 15 18 21 Time
At "Weekly timer" + "Set back timer" setup
Easy-to-understand time bar display
SUMOTUWETH FR SA
7
3126 9
15 1821
24°C
24°C 28°C 24°C
Screen
after setup
Weekly
timer
Setback
timer
Setback timerWeekly timer
Possible to set temperature for two time spans and
for each day of the week.
SUMOTUWETH FR SA
3126 9
15 18 21
Setup screen example
(Set from Sunday to Saturday: 12:00 to 15:00, 28 °C.)
28°C
0 3 6 9 12 15 18 21 Time
24°C
0 3 6 9 12 15 18 21 Time
28°C
Easy-to-understand operationSimple installation
Components are compatible with standard
switch boxes. Flat back construction allows
equipment to be installed wherever it is
needed.
Timer
area
[
Variable timer control
]
The operation/display sections are zoned according to time and operation, enabling variable programming to match application.
Operation
area
European
switch box
- (01 - 03) -
JIS box
FUNCTIONS
DUCT TYPE
AR A36-45L
15
2
6
7
8
9
10
11
1
3
4
13
12
5
14
Display panel
19
20
16
18
17
1
START/STOP button
Pressed to start and stop operation.
2
Set temperature button
Selects the setting temperature.
3
Master control button
Selects the operating mode(AUTO, HEAT, FAN, COOL, DRY).
4
Fan control button
Selects the fan speed (AUTO, QUIET, LOW, MED, HIGH).
5
Economy button
Turns the economy efficient mode on and off.
6
Timer mode (CLOCK ADJUST) button
Selects the timer mode (OFF TIMER, ON TIMER, WEEKLY TIMER).
Set the current time.
Note :
Specifications are based on the following conditions.
Cooling : Indoor temperature of 27 °CDB / 19 °CWB.and outdoor temperature of 35 °CDB/24 °CWB.
Heating : Indoor temperature of 20 °CDB / 15 °CWB.and outdoor temperature of 7 °CDB/6 °CWB.
Standard static pressure : 30Pa
Pipe length : 7.5 m, Height difference : 0 m.(Outdoor unit - Indoor unit)
Sound pressure level : Install a 2m duct to the outlet port and a 1m duct to the suction poit and measure.
*The maximum current and the maximum input value are the maximum values when operated within the operation (temperature) range.