GarrettCom P80C, P80F User Manual

0 (0)
GarrettCom P80C, P80F User Manual

Magnum P80F & P80C

Personal Switches

Installation and User Guide

www . GarrettCom . com

Magnum P80F & P80C Personal Switches

Installation and User Guide (07/03)

MagnumP80F & P80C Personal Switches

Installation and User Guide

Part #: 84-00079, (Rev B 4/01)

Trademarks

Ethernet is a trademark of Xerox Corporation

NEBS is a trademark of Telcordia Technologies

UL is a registered trademark of Underwriters Laboratories

GarrettCom, Magnum and Personal Switch are trademarks and Personal Switch is a registered trademark of GarrettCom, Inc.

Important: The Magnum P80F & P80C Personal Switch contains no user serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. If problems are experienced with Magnum P80F & P80C Personal Switch products, consult Section 5, Troubleshooting, of this User Guide.

Copyright © 2001 GarrettCom, Inc. All rights reserved. No part

of this publication may be reproduced without prior written permission from

GarrettCom, Inc.

Printed in the United States of America.

www . GarrettCom . com

i

Magnum P80F & P80C Personal Switches

Installation and User Guide (07/03)

Contacting GarrettCom, Inc

Please use the mailing address, phone and fax numbers and email address listed below:

GarrettCom, Inc.

47823 Westinghouse Dr.

Fremont, CA 94539

Phone (510) 438-9071

Fax (510) 438-9072

Website: http://www.GarrettCom.com

email support@garrettcom.com

Federal Communications Commission

Radio Frequency Interference Statement

This equipment generates, uses and can radiate frequency energy and if not installed and used properly, that is in strict accordance with the manufacturer's instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be required to correct the interference.

www . GarrettCom . com

ii

Magnum P80F & P80C Personal Switches

Installation and User Guide (07/03)

The Magnum Line

ETHERNET CONNECTIVITY PRODUCTS

"DESIGNED AND MANUFACTURED IN THE USA"

OVERVIEW

GarrettCom, Inc.offers the premium-quality Magnumline of Ethernet LAN connectivity products with industry-standard functionality and built-in fiber configurability. Magnum products are designed for use in demanding Carrier Class, Industrial Grade and OEM applications where reliability is a primary consideration.

4K-Series Switches, 100 & 10Mbps, copper ports with optional fiber port, with auto-negotiating full switching performance

Quad-Series Fiber Switches, 100 & 10Mbps, fiber and copper ports, mixed-speed and mixed-media types, full switching performance

“Outdoor” Ethernet Switch, for temperature uncontrolled locations 6 10/100 and 2 100Mb fiber ports, can be connected in strings

Mixed-Media Fiber Hub, 16-port Stackable, 10/100 auto-sensing Dual Speed 8-port and 16-port Stackables, 10/100 auto-sensing

Stackable Hubs, SNMP Optional

10Mb series and 100Mb series, both w/ optional port modules

Personal Switches, 10/100Mb

8 port dual speed, Auto-negotiable with fiber option

Personal Hubs, 100Mb or 10/100Mb

8-port, with two switched ports (1 fiber built in)

Personal Hubs, 10Mb series

8-port + AUI, stackable to 5 high, + optional BNC of fiber port 8 or 9-port and 4 or 5-Port Personal Hubs, w/ man. up-link sw.

Media Converters, 10Mb and 100Mb series

All media combinations, incl. fiber ST, SC, mm., single mode

The “X-line” of configurable MiXed Media products: Stackable Concentrators, SNMP optional, 13-Ports Mini-Concentrators, 7 Ports, Repeaters, 2-Ports

Repeater Port Modules (RPMs), 6 types for Ethernet media

Bridge Port Modules (BPMs), 4 types, for segment isolation

Fan-Outs, 10Mb series

2, 4 and 8 Port Models

Transceivers, 10Mb and 100Mb series 10Mb Mini-Transceivers and Coax Models, All Types - Apr, 01

www . GarrettCom . com

iii

Magnum P80F & P80C Personal Switches

Installation and User Guide (07/03)

TABLE OF CONTENTS

 

PAGE

1.0 SPECIFICATIONS ........................................................................................

 

2

1.1

Technical Specifications.....................................................................................

 

2

1.2

Ordering Information..........................................................................................

 

4

2.0 INTRODUCTION..........................................................................................

 

5

2.1

Inspecting the Package and Product ...................................................................

 

5

2.2

Product Description ............................................................................................

 

5

 

2.2.1 Magnum P80F Chassis............................................................................

 

6

 

2.2.2 Magnum P80C Chassis ...........................................................................

 

7

2.3

Up-link on Port # 1SW for Cascading ..............................................................

 

7

2.4

100Mbps Fiber port, ST or SC Connector for P80F ..........................................

8

2.5

Frame buffering and Latency.............................................................................

 

9

2.6

Features and Benefits.........................................................................................

 

10

2.7

Applications (P80F & P80C) .............................................................................

 

11

3.0 INSTALLATION.........................................................................................

 

14

3.1

Locating Magnum P80F & P80C Personal Switches.........................................

14

 

3.1.1 Table-Top or Shelf Mounting ................................................................

 

14

 

3.1.2 Wall (or Vertical Surface) Mounting .....................................................

 

14

3.2

Connecting Ethernet Media .............................................................................

 

15

 

3.2.1 Connecting Twisted Pair (RJ-45, Cat-3, CAT-5)...................................

15

 

3.2.2 Connecting Fiber Optic SC-type, “Twist-lock” .....................................

16

 

3.2.3 Connecting Fiber Optic ST-Type, “Snap-In”.........................................

16

 

3.2.4 Connecting Fiber Optic Single-mode.....................................................

 

16

 

3.2.5 Power budget Calculation for P80F Fiber media ...................................

17

 

3.2.6 Connecting to NICs which support Auto-Negotiation ...........................

17

3.3 Powering the Magnum P80F & P80C ..............................................................

 

18

4.0 OPERATION ...............................................................................................

 

19

4.1

Dual-Speed Functionality and Switching ..........................................................

 

19

4.2

Auto-negotiation and speed-sensing .................................................................

 

20

4.3

Full or Half duplex, manual selection for P80F Models ....................................

20

4.4

Full or Half duplex, manual selection for P80C ................................................

 

20

4.5 LEDs .................................................................................................................

 

21

4.6

Up-link Port, 1SW or 1 .....................................................................................

 

21

4.7

Use with media converters.................................................................................

 

21

5.0 TROUBLESHOOTING ...............................................................................

 

22

5.1

Before Calling for Assistance ............................................................................

 

22

5.2

When Calling for Assistance .............................................................................

 

23

5.3

Return Material Authorization (RMA) Procedure .............................................

 

23

5.4

Shipping and Packaging Information.................................................................

 

24

APPENDIX A: WARRANTY INFORMATION ...........................................................

 

24

Revisions

Rev B 04/01 : Change the company name to GarrettCom, Inc. (Formerly it was Garrett Communications). There are no changes to the content of the material at this time

Rev A 09/00 : This revision is the initial release of the P80F &P80C Personal Switch user manual.

www . GarrettCom . com

1

Magnum P80F & P80C Personal Switches

Installation and User Guide (07/03)

1.0SPECIFICATIONS

1.1Technical Specifications

Ports Performance

When a port is operating at 100Mbps: Data Rate: 100Mbps

When a port is operating at 10 Mbps: Data Rate: 10 Mbps

Network Standards

100Mb: Ethernet IEEE 802.3u, 100BASE-TX, 100BASE-FX 10 Mb: Ethernet IEEE 802.3, 10BASE-T

Auto-sensing for speed: IEEE 802.3u

Packet-Processing Between Domains

Filtering and Forwarding Rate from 100Mbps ports: 148,800 pps max Filtering and Forwarding Rate from 10 Mbps ports: 14,880 pps max. Processing type: Store and Forward

Auto-learning: 16K address table, shared for all traffic domains Packet buffers: 512KB, dynamically shared on all domains Latency (not including packet time): 100 to 10 Mbps: 5µs

10 to 100Mbps: 5µs

Path Delay Value: 50 BT on all ports

Maximum Ethernet Segment (or Domain) Lengths

10BASE-T (Unshielded twisted pair)

- 100 m (328 ft)

100BASE-TX (CAT 5 UTP)

- 100 m (328 ft)

100BASE-FX, half-duplex: (multi-mode)

- 412 m (1350 ft)

100BASE-FX, full-duplex: (multi-mode)

- 2.0 km (6,562 ft)

100BASE-FX, half-duplex: (single-mode)

- 412 m (1350 ft)

100BASE-FX, full-duplex: (single-mode)

- 20.0 km (65,620 ft)

100BASE-FX, full-duplex: (single-mode, long)

- 40.0 km (131,240 ft)

Operating Environment

 

Ambient Temperature:

32ºF to 120ºF (0ºC to 50ºC)

Storage Temperature:

-5ºC to 160ºF (-20ºC to 70ºC)

Ambient Relative Humidity: 10% to 95% (non-condensing)

Power Supply (External)

 

Input:

95-125 vac at 60Hz for “-d” Models

 

200-250 vac at 50Hz for “-i” Models, which have IEC

 

power cable connector in the external power unit.

Output:

5VDC, 2Amps

Polarity:

center positive, shell negative

Power Consumption: 8 watts typical, 10 watts max.

www . GarrettCom . com

2

Magnum P80F & P80C Personal Switches

Installation and User Guide (07/03)

External -48VDC Power Supply (Optional)

Power Input Voltage: 36 to 70 VDC (auto ranging), “-, GND, +” Power Consumption: 8 watts typical, 10 watts max.

Network Cable Connectors - for eight RJ-45 shielded female ports and 1 fiber port 100Mbps: Category 5 UTP/STP, fiber (50/125, 62.5/125, 9/125 micron)

10 Mbps: Category 3, 4, 5 UTP (Note: auto-sensing does not sense cable type) Maximum Load per port: 60 mA

Up-Link, Port # 1 or 1SW

Port # 1 (switched RJ-45) has a manual crossover (MDIX up-link) switch for connection to a central switch or to another P80F, P80C (or equal) unit. The uplink port # 1 is auto-sensing for speed, and its auto-negotiating up-link feature works the same at 10 Mbps or 100Mbps speed and at fullor half-duplex mode.

Fullor Half-Duplex selection on switched Ports # 2 or 2SW for Magnum P80F

Manual switch selects fiber port for FDX or HDX. See Section 4.3 for details.

Full-Fixed or Auto-negotiation selection on switched Ports # 2 or 2SW for Magnum P80

Manual switch selects port #2 for “FF” or “A”. See Section 4.3 for details.

Packaging

Enclosure: Rugged high-strength sheet metal. Metal mounting clips included. Suitable for wiring closet shelf, wall or desktop mounting. Dimensions: 1.25 in H x 6.75 in W x 5.0 in D (3.2 cm x 17.1 cm x 12.7 cm) Weight (of Switch unit): 1.0 lb. (455 g.)

Weight (of power supply unit): 1.0 lb. (455 g.) Cooling method: Convection

LED Indicators

PWR: Steady On when power applied ERROR: Self-test at power up failed

SPEED (with LINK ON): ON = 100Mbps; OFF = 10 Mbps LINK/ACT: Steady On for LINK with no traffic, blinking indicates port

is transmitting / receiving. F/H: ON = full-duplex, OFF = half-duplex

Agency Approvals

 

UL Listed (UL 1950), cUL, CE

 

Emissions: meets FCC Part 15, Class B

 

Warranty: Three years, return to factory

Made in USA

www . GarrettCom . com

3

Magnum P80F-MTRJ-d, or -i:
Magnum P80F-SSCL-d, or -i:
Magnum P80F-SSC-d, or -i:
Magnum P80F-MST-d, or -i:

Magnum P80F & P80C Personal Switches

Installation and User Guide (07/03)

1.2Ordering Information

Magnum P80F, 10/100 Personal Switch

with a 100Mb Fiber Port

Magnum P80F-MSC-d, or -i: 8-port Personal Switch with one 100Mbps switched fiber port (multi-mode SC-type connector), and seven “N-way” halfor full-duplex switched RJ-45 10/100 auto-negotiating ports. Includes store-and-forward switching that filters and forwards data moving between the ports. The internal switch has 16K nodes address table and 512KB packet buffers. External power supply.

Same as P80F but with multi-mode STtype fiber connector.

Same as P80F but with single-mode SC-type fiber connector.

Same as P80F but with single-mode (Long reach, 40Km) SC-type fiber connector. Same as P80F but with multi-mode MTRJtype fiber connector.

Magnum P80C, 10/100 Personal Switch with all copper ports

Magnum P80C-d, or -i: 8-port 10/100Mb “copper” office switch with eight 10/100 N-way auto-negotiating switched ports. Includes store-and-forward switching that filters and forwards data moving between the ports. The internal switch has 16K nodes address table and 512KB packet buffers. External power supply.

Use “-d” suffix for external power supply at 115vac 60Hz; use “-i” suffix for external at 230vac 50Hz.

GarrettCom reserves the right to change specifications, performance characteristics and / or model offerings without notice.

www . GarrettCom . com

4

Magnum P80F & P80C Personal Switches

Installation and User Guide (07/03)

2.0INTRODUCTION

2.1Inspecting the Package and Product

Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage that you believe occurred during shipment or delivery. Inspect the contents of this package for any signs of damage and ensure that the items listed below are included.

This package should contain:

1Magnum P80F Personal Switch with a Fiber Port, or Model P80C with all copper ports.

1 External Power Supply, 5VDC from either 115v 60Hz or 230v 50Hz

1 Set of metal clips and screws for secure shelf or wall-mounting

1 Installation and User Guide

1 Product Registration Card

Remove the Magnum P80F or P80C Personal Switch from the shipping container. Be sure to keep the shipping container should you need to ship the unit at a later date. To validate the product warranty, please complete and return the enclosed Product Registration Card to GarrettCom as soon as possible.

In the event there are items missing or damaged, contact your supplier. If you need to return the unit, use the original shipping container. Refer to Chapter 5, Troubleshooting, for specific return procedures.

2.2Product Description - General

The P80-series Personal Switches provide the performance of a built-in 100Mb switched fiber link upstream, coupled with the convenience of switched 10/100Mb copper ports for workplace LAN connections, all in one compact unit.

Magnum P80F “Future-proof Fiber” models have been designed with one full-duplex 100Mbps switched fiber port, and seven of “N-way” switched RJ-45 with full / half-duplex 10/100 auto-negotiating RJ-45 ports. The P80C “Copper” model has been designed with all eight RJ-45 switched ports with “N-way” x half/full duplex capability and functions as 10/100 auto-

www . GarrettCom . com

5

Loading...