DGebrauchsanweisung

Tauchpumpe/Schmutzwasserpumpe

GB Operating Instructions

Submersible Pump/Dirty Water Pump

FMode d’emploi

Pompe pour eaux claires/Pompe pour eaux chargées

NL Gebruiksaanwijzing

Dompelpomp/Vuilwaterpomp

SBruksanvisning

Dränkbar pump/spillvattenpump

IIstruzioni per l’uso

Pompa sommersa/Pompa sommersa per acqua sporca

EManual de instrucciones

Bomba sumergible/Bomba para aguas sucias

PInstruções de utilização

Bomba submersível/Bomba para esgotos

DK Brugsanvisning

Dykpumpe/Pumpe til snavset vand

D

GB

F

NL

S

I

E

P

DK

GB

GARDENA Submersible Pump 6000 S/

Dirty Water Pump 6000 SP

Welcome to the garden of GARDENA ...

Please read these operating instructions carefully and observe the notes given. Use these operating instructions to familiarise yourself with your Pump, its proper use and the notes on safety.

For safety reasons, children under the age of 16 and people not familiar with these operating instructions must not use this pump.

 

Please Keep these operating instructions in a safe place.

 

Contents:

1. Where to use your GARDENA Pump. . . . . . . . . . . . . . . . . . .

10

 

2.

Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

 

3.

Using the Pump for the First Time . . . . . . . . . . . . . . . . . . . .

12

 

4.

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13

 

5.

Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

 

6.

Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

 

7.

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

14

 

8.

Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

15

 

9.

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

16

1. Where to use your GARDENA Pump

 

 

 

Correct use:

The GARDENA pump is intended for private use around the house

 

and garden. It is primarily intended for drainage purposes if flooding

 

(please ensure this word is not split over 2 lines) occurs but also

 

for transferring water to and from tanks and pumping them out,

 

 

for drawing water from wells and shafts, for draining boats and

 

 

yachts and for aerating and circulating water for limited periods.

Liquid conveyed:

The GARDENA pump is suitable for conveying:

 

 

• Submersible pump 6000 S: clean to slightly dirty water with a

 

 

max. particle size of 5 mm,

 

 

• Dirty water pump 6000 SP: dirty water with a max. particle size

 

 

of 25 mm,

 

 

and swimming pool water (provided that the additives have been

 

measured and added in accordance with manufacturers’ instruc-

 

tions) and soapy water.

 

 

The pump can be fully submerged (watertight encapsulation) and

 

can be lowered down to a depth of 9 m into the water.

 

 

 

Please note:

The GARDENA pump is not intended for long term use (e. g.

 

use for continuous circulation) in a pond. The length of life

 

 

of the pump will be shortened accordingly if used in this way.

 

Corrosive, flammable or explosive substances (e.g. petrol,

 

 

paraffin, cellulose thinners); grease, oil, salt water and

 

 

sewage must not be conveyed by the pump. The temperature

 

of the liquid conveyed may not exceed 35 °C.

 

 

 

 

 

10

2. Safety Instructions

Electrical safety:

DANGER ! Electric shock !

The pump must not be operated if there are people in the swimming pool or garden pond.

Ensure that the electrical plug and socket connections are fitted in an area which cannot flood.

Protect power plug from moisture.

According to DIN VDE (German Electrical Engineers’ Association) 0620, mains power cables must not have a smaller cross-section than the rubber-sheathed cables of the designation H05 RNF. The cable length must be at least 10 m.

Data indicated on the type plate must match technical data of the mains supply.

According to DIN VDE 0100, pumps may only be operated in swimming pools, garden ponds and wells via a fault current circuit breaker with a nominal fault current of 30 mA.

Swimming pools and garden ponds should be designed according to international and national design regulations.

For safety reasons we recommend that the pump is always operated by a residual -current device (DIN VDE 0100-702 and 0100-738).

If in doubt please consult a qualified electrician.

Protect plug and power cable from heat, oil and sharp edges.

The connection cable of the pump cannot be replaced. If the cable is damaged the pump must be scrapped.

Do not pull out the power cable

socket as a method of turning the pump off.

The power cable or the float switch must not be used for mounting or relocating the pump. For submerging or lifting/securing the pump, fix a rope to the pump’s carrying handle.

In Austria, according to ÖVE B/EN 60 555 parts 1 to 3, pumps which are used in swimming pools and garden ponds, and equipped with firm power cable should be fed via an ÖVE approved isolating transformer

– rated voltage must not exceed 230 V.

In Switzerland mobile appliances which are used outdoors must be connected via a residual-current device.

Operating instructions:

 

Before operating the pump look

see if

there is any damage to the

(especially

to the power cable and plug).

 

Clear the outlet line before use. Avoid

running the pump with the

side

closed off for more than 10 minutes.

against closed delivery side of

pump.

Observe the minimum water

and the

max. delivery height (see 8. Technical

Data).

 

A damaged pump must not be

 

In case of damage, please have

pump

checked by our GARDENA Service Centre.

Dry-running operation causes increased wear and is to be avoided. Therefore, in manual operation the pump must be immediately unplugged when water fails to flow

Observe the pump at all times during manual operation.

Take care that the pump is located where the inlet openings at the suction are not obstructed neither completely nor partly.

Stand the pump on a brick if using

a pond.

Safety instructions:

 

Thermal motor protector:

 

The pump is automatically

off on

overheating by the built-in thermal motor

protector. After having cooled

the

motor automatically switches on again (see 7. Troubleshooting).

Automatic Air bleed valve:

The automatic air bleed valve eliminates any air pockets in the pump. During process, e and air

bubbles appear underwater. This is not a defect of your pump, but serves to deaerate the pump, but serves to remove air from the pump.

It may take several seconds for the air to escape when the pump is immersed for the first time.

e

GB

11

GB

3. Using the Pump for the First Time

Hose diameter

13 mm (1/2”)

 

 

15 mm (5/8”)

25 mm (1”)

38 mm (11/2”)

 

19 mm (3/4”)

 

 

 

 

 

 

 

 

Hose connection

 

 

 

 

 

 

 

 

 

 

of universal fitting

 

 

 

 

 

a

 

b

a

 

 

 

b

 

 

Hose connection

Connection kits needed for 13 - 19 mm hoses:

Cut off topmost

Do not cut off any

Cut off top two

nipple at a

nipples

nipples at b

13 mm (1/2”): GARDENA Pump Connection Set, Art. No. 1750

15 mm (5/8”): GARDENA Tap Connector, Art. No. (2)902, and Standard Hose Connector, Art. No. (2)916

19 mm (3/4”): GARDENA Pump Connection Set, Art. No. 1752

Best results in delivery capacity are achieved when using 38 mm (11/2”) hoses.

Connecting the hose: The universal fitting llows connection of all the hoses listed in the table above.

1.Screw L-piece into the pump.

2.Cut off nipples of the universal fitting which are not needed, to match the hose connection.

3.Screw the universal fitting onto the pump.

4. Connect the hose to the universal fitting .

We recommend that 38 mm (11/2”)- and 25 mm (1”) hoses should be fastened with an additional GARDENA hose clamp Art. No. 7193.

Only for 13 mm (1/2”) hose:

The universal fitting can also be equipped with a GARDENA

Regulator Valve Art. No. (2)977 so that the contents of the outlet line do not flow back through the pump after pumping. The Regulator Valve can be ordered from your GARDENA dealer.