Fujitsu TX1320 M1 User Manual

0 (0)

Operating Manual - English

FUJITSU Server PRIMERGY TX1320 M1

Operating Manual

Edition July 2014

CommentsSuggestionsCorrections

The User Documentation Department would like to know your opinion of this manual. Your feedback helps us optimize our documentation to suit your individual needs.

Feel free to send us your comments by e-mail to manuals@ts.fujitsu.com.

Certified documentation according to DIN EN ISO 9001:2008

To ensure a consistently high quality standard and user-friendliness, this documentation was created to meet the regulations of a quality management system which complies with the requirements of the standard DIN EN ISO 9001:2008.

cognitas. Gesellschaft für Technik-Dokumentation mbH www.cognitas.de

Copyright and Trademarks

Copyright © 2014 Fujitsu Technology Solutions GmbH.

All rights reserved.

Delivery subject to availability; right of technical modifications reserved.

All hardware and software names used are trademarks of their respective manufacturers.

The contents of this manual may be revised without prior notice.

Fujitsu assumes no liability for damages to third party copyrights or other rights arising from the use of any information in this manual.

No part of this manual may be reproduced in any form without the prior written permission of Fujitsu.

Microsoft, Windows, Windows Server, and Hyper V are trademarks or registered trademarks of Microsoft Corporation in the USA and other countries.

Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the USA and other countries.

Before reading this manual

For your safety

This manual contains important information for safely and correctly using this product.

Carefully read the manual before using this product. Pay particular attention to the accompanying manual "Safety Notes and Regulations" and ensure these safety notes are understood before using the product. Keep this manual and the manual "Safety Notes and Regulations" in a safe place for easy reference while using this product.

Radio interference

This product is a "Class A" ITE (Information Technology Equipment). In a domestic environment this product may cause radio interference, in which case the user may be required to take appropriate measures. VCCI-A

Aluminum electrolytic capacitors

The aluminum electrolytic capacitors used in the product's printed circuit board assemblies and in the mouse and keyboard are limited-life components. Use of these components beyond their operating life may result in electrolyte leakage or depletion, potentially causing emission of foul odor or smoke.

As a guideline, in a normal office environment (25°C) operating life is not expected to be reached within the maintenance support period (5 years). However, operating life may be reached more quickly if, for example, the product is used in a hot environment. The customer shall bear the cost of replacing replaceable components which have exceeded their operating life. Note that these are only guidelines, and do not constitute a guarantee of trouble-free operation during the maintenance support period.

High safety use

This product has been designed and manufactured to be used in commercial and/or industrial areas as a server.

When used as visual display workplace, it must not be placed in the direct field of view to avoid incommoding reflections (applies only to TX server systems).

The device has not been designed or manufactured for uses which demand an extremely high level of safety and carry a direct and serious risk of life or body if such safety cannot be assured.

TX1320 M1

Operating Manual

These uses include control of nuclear reactions in nuclear power plants, automatic airplane flight control, air traffic control, traffic control in mass transport systems, medical devices for life support, and missile guidance control in weapons systems (hereafter, "high safety use"). Customers should not use this product for high safety use unless measures are in place for ensuring the level of safety demanded of such use. Please consult the sales staff of Fujitsu if intending to use this product for high safety use.

Measures against momentary voltage drop

This product may be affected by a momentary voltage drop in the power supply caused by lightning. To prevent a momentary voltage drop, use of an AC uninterruptible power supply is recommended.

(This notice follows the guidelines of Voltage Dip Immunity of Personal Computer issued by JEITA, the Japan Electronics and Information Technology Industries Association.)

Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan

Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan. Documents which contain such technology should not be exported from Japan or transferred to non-residents of Japan without first obtaining authorization in accordance with the above law.

Harmonic Current Standards

This product conforms to harmonic current standard JIS C 61000-3-2.

Only for the Japanese market: About SATA hard disk drives

The SATA version of this server supports hard disk drives with SATA / BC-SATA storage interfaces. Please note that the usage and operation conditions differ depending on the type of hard disk drive used.

Please refer to the following internet address for further information on the usage and operation conditions of each available type of hard disk drive:

http://jp.fujitsu.com/platform/server/primergy/harddisk/

Operating Manual

TX1320 M1

Only for the Japanese market:

Shielded LAN cables should be used in this product.

IAlthough described in this manual, some sections do not apply to the Japanese market. These options and routines include:

– CSS (Customer Self Service)

TX1320 M1

Operating Manual

Operating Manual

TX1320 M1

Contents

1

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . .

11

1.1

Concept and target groups for this manual . . . . . . . . .

12

1.2

Documentation overview . . . . . . . . . . . . . . . . . . .

12

1.3

Notational conventions . . . . . . . . . . . . . . . . . . . .

13

2

Functional overview . . . . . . . . . . . . . . . . . . . . . .

15

2.1Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

2.2

Server specification . . . . . . . . . . . . . . . . . . . . . .

24

3

Installation steps, overview . . . . . . . . . . . . . . . . . .

31

4

Important information . . . . . . . . . . . . . . . . . . . . .

33

4.1Safety instructions . . . . . . . . . . . . . . . . . . . . . . . 33

4.2

CE conformity . . . . . . . . . . . . . . . . . . . . . . . . .

41

4.3

FCC Class A Compliance Statement . . . . . . . . . . . . .

42

4.4

Transporting the server . . . . . . . . . . . . . . . . . . . .

43

4.5

Environmental protection . . . . . . . . . . . . . . . . . . .

43

5

Hardware installation . . . . . . . . . . . . . . . . . . . . . .

45

5.1

Unpacking the server . . . . . . . . . . . . . . . . . . . . .

46

5.2Setting up the server . . . . . . . . . . . . . . . . . . . . . . 47

5.2.1

Positioning the server vertically . . . . . . . . . . . . . . . . . 48

5.2.2Positioning the server horizontally . . . . . . . . . . . . . . . . 51

5.3Connecting devices to the server . . . . . . . . . . . . . . . 53

5.4Connecting the server to the mains . . . . . . . . . . . . . . 54

5.4.1

Using cable ties . . . . . . . . . . . . . . . . . . . . . . . . . 54

TX1320 M1

Operating Manual

Contents

5.5Notes on connecting/disconnecting cables . . . . . . . . . . 56

6

Starting up and operation .

.

. . . . . . .

. . . . . . . . . .

. 59

6.1

Opening the drive cover .

.

. . . . . . .

. . . . . . . . . .

. 59

6.2Opening the HDD cover . . . . . . . . . . . . . . . . . . . . . 62

6.3Controls and indicators . . . . . . . . . . . . . . . . . . . . . 63

6.3.1

Front of server . . . . . . . . . .

. . . . . . . . . . . . . . . . 63

6.3.1.1

Local diagnostic indicators . .

. . . . . . . . . . . . . . . . 64

6.3.1.2

Control elements . . . . . . .

. . . . . . . . . . . . . . . .

65

6.3.1.3

Indicators on the control panel

. . . . . . . . . . . . . . . .

66

6.3.1.4ID card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67

6.3.1.5 Indicators on the drives . . . . . . . . . . . . . . . . . . . . 68

6.3.2Rear of the server . . . . . . . . . . . . . . . . . . . . . . . . . 70

6.4

Switching the server on and off

. .

.

. . . . . . . . .

.

.

.

.

73

6.5

Configuring the server . . . .

. . .

.

. . . . . . . . .

.

.

.

.

75

6.5.1Configuring the onboard SATA controller . . . . . . . . . . . . . 75

6.5.2Configuring the SAS/SATA RAID controller . . . . . . . . . . . . 75

6.5.3Configuring the server and installing the operating system

with the ServerView Installation Manager . . . . . . . . . . . . . 76

6.5.4Configuring the server and installing the operating system

without the ServerView Installation Manager . . . . . . . . . . . 77

6.6

Cleaning the server . . . . .

. . . . . . . . . . . . . . . . . . 78

7

Property and data protection

. . . . . . . . . . . . . . . . . . 79

7.1

Mechanical access protection . . . . . . . . . . . . . . . . . 79

7.2BIOS Setup security functions . . . . . . . . . . . . . . . . . 79

8

Troubleshooting and tips . . . . . . . . . . . . . . . . . . . . 81

8.1Power-on indicator remains unlit . . . . . . . . . . . . . . . . 81

8.2

Server switches itself off . . . . . . . . . . . . . . . . . . . . 82

8.3Screen remains blank . . . . . . . . . . . . . . . . . . . . . . 82

8.4

Flickering stripes on monitor screen . . . . . . . . . . . . . 83

Operating Manual

TX1320 M1

Contents

8.5

No screen display or display drifts . . . . . . . . . . . . . . 83

8.6No mouse pointer displayed on screen . . . . . . . . . . . . 83

8.7

Incorrect date and time . . . . . . . . . . . . . . . . . . . .

84

8.8

Drives reported as “dead” when starting system . . . . . .

84

8.9

Added drive reported as defective . . . . . . . . . . . . . .

84

8.10

Error message on screen . . . . . . . . . . . . . . . . . . .

85

TX1320 M1

Operating Manual

Contents

Operating Manual

TX1320 M1

1 Introduction

The PRIMERGY TX1320 M1 server is an Intel-based server for small and medium-sized networks and can be used in the horizontal position or as a desktop model.

The PRIMERGY TX1320 M1 server features exceptionally low energy consumption, very quiet running and a compact size. As a result, it is also the ideal solution for small offices.

Thanks to its highly developed hardware and software components, the PRIMERGY TX1320 M1 server offers a high level of data security and availability. This includes hot-plug HDD modules (2.5-inch variant), the ServerView Operations Manager for server management, Prefailure Detection and Analysing (PDA), and Automatic Server Reconfiguration and Restart (ASR&R).

Security functions in the BIOS-setup protect the data on the server against manipulation. Additional security is provided by the lockable drive cover.

TX1320 M1

Operating Manual

11

Introduction

1.1Concept and target groups for this manual

This operating manual describes how to install, set up and operate your server.

This operating manual is intended for those responsible for installing the hardware and ensuring that the system runs smoothly. It contains all the information you need to put your PRIMERGY TX1320 M1 into operation.

To understand the various expansion options, you will need to be familiar with the fields of hardware and data transmission and you will require a basic knowledge of the underlying operating system.

1.2Documentation overview

More information on your PRIMERGY TX1320 M1 can be found in the following documents:

"Quick Start Hardware - FUJITSU Server PRIMERGY TX1320 M1" (only included as a printed copy)

"Quick Start Guide"

"Safety Notes and Regulations" manual

"" for the Japanese market

"Warranty" manual

"" for the Japanese market

"ServerView Suite Local Service Concept - LSC" manual

"Returning used devices" manual and "Service Desk" leaflet

"" for the Japanese market

"FUJITSU Server PRIMERGY TX1320 M1 Upgrade and Maintenance Manual"

“D3239 BIOS Setup Utility for FUJITSU Server PRIMERGY TX1320 M1 Reference Manual"

12

Operating Manual

TX1320 M1

Fujitsu TX1320 M1 User Manual

Introduction

IAll documentation on PRIMERGY hardware and ServerView software is available online from the Fujitsu manuals server at:

For the global market http://manuals.ts.fujitsu.com

For the Japanese market: http://jp.fujitsu.com/platform/server/primergy/manual

The complete PRIMERGY documentation set can also be downloaded as a DVD ISO image at:

For the global market: ftp://ftp.ts.fujitsu.com/images/serverview/manuals

For the Japnese market: http://jp.fujitsu.com/primergy/downloads

Further sources of information:

ServerView Suite Glossary

Manual for the monitor

Documentation for the boards and drives

Operating system documentation

Information files in your operating system

1.3Notational conventions

The following notational conventions are used in this manual:

Text in italics

indicates commands or menu items.

"Quotation marks"

indicate names of chapters and terms that are being

 

emphasized.

 

 

Ê

describes activities that must be performed in the order

 

shown.

 

 

VCAUTION!

pay particular attention to texts marked with this symbol.

Failure to observe this warning may endanger your life,

 

destroy the system or lead to the loss of data.

Iindicates additional information, notes and tips.

TX1320 M1

Operating Manual

13

Introduction

14

Operating Manual

TX1320 M1

2 Functional overview

This section provides information on the features and technical data of the PRIMERGY TX1320 M1 server.

2.1Features

Intel® Xeon®, Pentium®, or Core i3 processor

The server has an Intel® Xeon®, Pentium®, or Core i3 processor for high-speed data processing.

Customer Self Service (CSS)

The PRIMERGY Customer Self Service (CSS) concept enables you to identify and replace the affected component yourself in the case of certain error scenarios.

In the CSS concept, you can replace the following components yourself in the event of an error:

Hot-plug hard disk drives

Memory modules

System fans

Expansion cards

For information on replacing these components, see the "FUJITSU Server PRIMERGY TX1320 M1 Upgrade and Maintenance Manual".

CSS indicators on the control panel and on the back of the PRIMERGY server provide you with information if a CSS event arises.

In addition, CSS errors are displayed in the ServerView Operations Manager, the server management software from Fujitsu.

In the event of errors, the ServerView Operations Manager refers you directly to the affected component and its order information in the Illustrated Spares catalog of the server in question. (This feature is not available for the Japanese market.)

TX1320 M1

Operating Manual

15

Functional overview

IFurther information on the CSS concept is provided in the "PRIMERGY ServerView Suite Local Service Concept - LSC" manual on the PRIMERGY ServerView Suite DVD.

For the latest information on optional products provided for the TX1320 M1 see the configurator of the server:

http://ts.fujitsu.com/products/standard_servers/index.html

(for the EMEA market)

http://jp.fujitsu.com/platform/server/primergy/system/

(for the Japanese market)

System board

The features of the system board are described in the "FUJITSU Server PRIMERGY TX1320 M1 Upgrade and Maintenance Manual" and in the "D3239 BIOS Setup Utility for FUJITSU Server PRIMERGY TX1320 M1 Reference Manual" for the firmware.

Trusted Platform Module (TPM)

A Trusted Platform Module (TPM) for safer storage of keys can be implemented as an option. This module enables programs from third party manufacturers to store key information (e.g. drive encryption using Windows Bitlocker Drive Encryption).

The TPM is activated via the BIOS system (for more information, refer to the “D3239 BIOS Setup Utility for FUJITSU Server PRIMERGY TX1320 M1 Reference Manual").

VCAUTION!

When using the TPM, note the program descriptions provided by the third party manufacturers.

You must also create a backup of the TPM content. To do this, follow the third party manufacturer's instructions. Without this backup, if the TPM or the system board is faulty you will not be able to access your data.

If a failure occurs, please inform your service about the TPM activation before it takes any action, and be prepared to provide them with your backup copies of the TPM content.

16

Operating Manual

TX1320 M1

Functional overview

Hard disk drives

The server is shipped with one of the following drive cages:

For up to two non hot-plug 3.5-inch SATA hard disk drives:

Up to two 3.5-inch SATA HDD modules can be used in the drive cage. Each HDD module can accommodate an SATA hard disk drive with a maximum height of 1 inch.

For up to six 2.5-inch SAS/SATA hard disk drives:

Up to four 2.5-inch SAS/SATA HDD modules can be used in the drive cage, up to two 2.5-inch SAS/SATA HDD modules can be used in the expansion box. Each HDD module can accommodate an SAS/SATA hard disk drive with a 2.5-inch format. The modules are connected to the SAS/SATA backplane wirelessly. This allows HDD modules to be plugged in or pulled out easily. If the server has a corresponding RAID configuration, defective HDD modules can also be replaced during operation.

Hybrid configurations of SAS and SATA HDD modules are not supported.

Onboard SATA controller

A SATA controller is integrated on the system board; up to four SATA hard disk drives can be connected to the controller. The LSI Embedded MegaRAID software (SATA Software RAID) supports RAID levels 0, 1 and 10.

For more information on configuring the controller, see section "Configuring the onboard SATA controller" on page 75.

TX1320 M1

Operating Manual

17

Functional overview

SAS/SATA RAID controller

The server is available with the following SAS/SATA RAID controllers for operating the internal SAS/SATA hard disk drives:

Modular RAID 0/1 controller with "Integrated Mirroring Enhanced" (SAS IME) for SAS1.0

RAID levels 0, 1 and 1E are supported for internal hard disk drive configurations.

Modular RAID 0/1 controller with "MegaRAID functionality" (SAS MegaRAID) for SAS1.0 and SAS2.0

RAID levels 0, 1,10 and 1E are supported for internal hard disk drive configurations.

Modular RAID 5/6 controller with "MegaRAID functionality" (SAS MegaRAID) for SAS1.0 and SAS2.0

RAID levels 0, 1, 10, 1E, 5, 50, 6 and 60 are supported for internal hard disk drive configurations. As an option, a battery backup unit (BBU) or a flash backup unit (FBU) can save the memory content even if the power fails. Cache memory size of 512 MB or 1 GB is available.

IFor more information on configuring the controller, see section "Configuring the server" on page 75.

Further information on SAS/SATA RAID controllers is provided in the "Modular RAID Controller Installation Guide" (on the Fujitsu manuals server under x86 Servers - Storage Adapters - LSI RAID / SCSI Controllers).

Further information on other SAS/SATA RAID controllers (e.g. for operating external SAS/SATA hard disk drives or tape drives) is available on ServerView Suite DVD under x86 Servers - Expansion Cards - Storage Adapters - LSI RAID / SCSI Controllers.

18

Operating Manual

TX1320 M1

Functional overview

Accessible drives/components

Two mounting locations are available:

a 3.5-inch bay for a backup drive.

a 5.25-inch bay with a slimline DVD drive.

The accessible drives cannot be replaced during operation.

Power supply

The server has a built-in power supply unit, which automatically sets itself to a mains voltage in the range 100V - 240V.

High level of availability and data security

When memory data is accessed, 1-bit errors are identified in the main memory and automatically corrected with the error correcting code (ECC) method.

ASR&R (Automatic Server Reconfiguration and Restart) restarts the system in the event of an error and automatically "hides" the defective system components.

The PDA (Prefailure Detection and Analysis) technology from Fujitsu analyzes and monitors all components that are critical for system reliability.

A RAID controller supports different RAID levels and increase the availability and data security of the system.

The hot-plug HDD modules provide additional availability.

TX1320 M1

Operating Manual

19

Functional overview

iRMC S4 with integrated management LAN connector

The iRMC S4 (integrated Remote Management Controller) is a Baseboard Management Controller (BMC) with integrated management LAN connector and expanded functionality that was previously only available with additional plug-in cards. In this way, the iRMC S4 enables complete control of PRIMERGY servers, regardless of system status, and thus particularly the control of PRIMERGY servers that are in the "out-of-band" system status.

Major functions supported by the iRMC S4 include the following:

Browser access via iRMC S4´s own Web server

Secure communication (SSH, SSL)

Power Management for the managed server (depending on its system status)

Power Consumption Management

Connecting virtual drives as remote storage

Text-based and graphic console bypass (Advanced Video Redirection)

Remote Storage

Command Line Interface (CLI)

Simple, interactive or script-based iRMC S4configuration

Customer Self Service (CSS)

iRMC S4´s own user management

Multi-computer, global iRMC S4 user administration using an LDAP Directory Service

Automatic network configuration via DNS / DHCP

Power supply of the iRMC S4 via the system standby supply

Full-coverage alarm management

System Event Log (SEL) reading and processing

IPMI support

CIM / WS-MAN support

Internal Event Log for user login / logout auditing

20

Operating Manual

TX1320 M1

Functional overview

More information about the iRMC S4 can be found in the "iRMC S4 - integrated Remote Management Controller" user guide (on the Fujitsu manuals server under x86 Servers - Software - ServerView Suite - Out-Of-Band Management).

Server management

Server management is implemented using the ServerView Operations Manager supplied and the PDA (Prefailure Detection and Analysis) technology from Fujitsu. PDA reports the threat of a system error or overload at an early stage, allowing preventive measures to be taken.

The ServerView Operations Manager enables the management of all PRIMERGY servers in the network via a central console. The ServerView Operations Manager supports the following functions:

Round-the-clock monitoring, regardless of server status

High-performance, graphical console bypass (AVR) protected by HTTPS/SSL (128 bit)

Remote storage via USB

Remote power on

Intrusion detection in the floorstand model

Temperature monitoring of the CPU and the surrounding area

Detailed status and error reports for processors and main memory

Watchdog timer for Automatic Server Reconfiguration and Restart (ASR&R) in the event that memory modules or processors fail

Power monitoring

End-of-life monitoring of fans with prompt notification before failure

Watchdog timer for monitoring the operating system with ASR&R

Further information on the ServerView Operations Manager is provided in the associated documentation.

TX1320 M1

Operating Manual

21

Functional overview

ServerView Installation Manager

You can configure the PRIMERGY server quickly and precisely with the ServerView Installation Manager software provided. User-guided menus are available for installing the server operating system (for further details see section "Configuring the server" on page 75).

Service and support

PRIMERGY servers are easy to maintain and modular, thus enabling quick and simple maintenance.

The handles and locks (touch points) used to exchange components are colored green to ensure simple and immediate recognition.

In order to prevent the components from being damaged by incorrect handling when they are being installed and removed, the areas of all components that can be touched without damaging them are also marked green.

PRIMERGY diagnostic LEDs fitted on the system board indicate which component (memory module, processor, fan or expansion card) is not functioning properly.

The Flash EPROM program supplied with the Fujitsu utilities supports a fast BIOS update.

With the iRMC (integrated Remote Management Controller) on the system board, the PRIMERGY TX1320 M1 server can also be maintained and serviced remotely. This enables remote diagnosis for system analysis, remote configuration and remote restart should the operating system or hardware fail.

22

Operating Manual

TX1320 M1

Functional overview

ServerView Remote Management

ServerView Remote Management is the remote management solution from Fujitsu for PRIMERGY servers. ServerView Remote Management and the relevant hardware components integrated on the system board allow remote monitoring and maintenance as well as fast restoration of operation in the event of errors.

Remote monitoring and maintenance avoids time-consuming and costly on-site repairs and reduces service costs. This leads to a reduction in the total cost of ownership and an excellent return on investment for the remote management solution.

The administrator can access all system information and information from the sensors such as fan speeds or voltages via the iRMC S4's Web interface (see section "iRMC S4 with integrated management LAN connector" on page 20).

You can also start the text-based or graphic console bypass (Advanced Video Redirection, AVR) and connect virtual drives as remote storage.

IMore information about the iRMC S4 can be found in the "iRMC S4 - integrated Remote Management Controller" user guide (on the Fujitsu manuals server under x86 Servers - Software - ServerView Suite - Out-Of- Band Management).

TX1320 M1

Operating Manual

23

Functional overview

2.2Server specification

This section explains the specifications for the server. The specifications for this server are liable to be updated without any notice. Please be forewarned.

System Board

System board type

D3239

 

 

Chipset

Intel® C224

Processor

 

 

 

Processor quantity and

1x Intel® Xeon® E3-1200 v3 (quad-core), Celeron®,

type

Pentium®, Core® i3

Memory Modules Configuration

 

 

Memory slots

4

 

 

Memory slot type

UDIMM (DDR3)

 

 

Memory capacity

2 GB - 32 GB

(min. - max.)

 

 

 

Memory protection

ECC

 

 

Memory notes

1600 MHz memory modules with 2, 4, or 8 GB

 

 

Interfaces

 

 

 

USB connectors

7x USB 2.0 (UHCI) with 480 MBit/s (4x external at

 

the rear, 2x external at the front, 1x internal for UFM,

 

no USB wake-up)

 

3x USB 3.0 (UHCI) with 5 GBit/s (2x external at the

 

rear, 1x internal for backup device)

Graphics (15-pin)

1 x VGA

 

 

Serial 1 (9-pin)

1 x serial RS-232-C, usable for iRMC or system or

 

shared

 

 

LAN / Ethernet (RJ-45)

2 x Gbit/s Ethernet

 

 

24

Operating Manual

TX1320 M1

Functional overview

Service LAN (RJ45) 1 x dedicated service LAN port for iRMC S4 (10/100/1000 Mbit/s) Service LAN traffic can be switched to shared onboard Gbit LAN port

Onboard or integrated controllers

RAID Controller

Modular RAID 0/1 controller with "Integrated

 

 

Mirroring Enhanced" (SAS IME) for SAS1.0.

 

 

RAID levels 0, 1 and 1E are supported for internal

 

 

hard disk drive configurations.

 

 

 

 

 

 

Modular RAID 0/1 controller with "MegaRAID

 

 

functionality" (SAS MegaRAID) for SAS1.0 and

 

 

SAS2.0.

 

 

RAID levels 0, 1,10 and 1E are supported for internal

 

 

hard disk drive configurations.

 

 

 

 

 

 

Modular RAID 5/6 controller with "MegaRAID

 

 

functionality" (SAS MegaRAID) for SAS1.0 and

 

 

SAS2.0. RAID levels 0, 1, 10, 1E, 5, 50, 6 and 60 are

 

 

supported for internal hard disk drive configurations.

 

 

 

SATA Controller

A 6-port SATA controller is integrated on the system

 

 

board; up to four SATA hard disk drives can be

 

 

connected to the controller. The LSI Embedded

 

 

MegaRAID software (SATA Software RAID)

 

 

supports RAID levels 0, 1 and 10.

Remote Management

Integrated Remote Management Controller

Controller

(iRMC S4, 32 MB attached memory incl. graphics

 

 

controller), IPMI 2.0 compatible

 

 

 

Trusted Platform

Infineon / 1.2 (option)

Module (TPM)

 

 

 

 

 

 

Slots

 

 

 

 

 

PCI-Express x8 Gen3

 

2x

 

 

 

PCI-Express x4 Gen2

 

1x (mechanically x8)

 

 

 

PCI-Express x1 Gen2

 

1x (mechanically x4)

 

 

 

Slot notes

 

in SAS configuration 1x PCI-Express occupied by

 

 

 

modular RAID controller

TX1320 M1

Operating Manual

25

Status LED at system System status (orange / yellow) rear side: Identification (blue)
LAN connection (green) LAN speed (green / yellow) CSS (yellow)

Functional overview

Drive bays

Hard disk bay

6x 2.5-inch hot-plug SAS/SATA or 2x 3.5-inch non

configuration

hot-plug SATA

 

 

 

Accessible drive bays

1x 3.5/1.6-inch for backup devices; 1x 5.25/0.5-inch

 

 

for CD-RW/DVD

 

 

 

Notes accessible drives

all possible options described in relevant system

 

 

configurator

 

 

 

Operating Panel

 

 

 

 

Operating buttons

On/off switch

 

 

 

 

 

NMI button

 

 

 

 

 

Reset button

 

 

 

 

 

ID button

 

 

Status LEDs

System status (orange / yellow)

 

 

 

 

 

Identification (blue)

 

 

 

 

 

Hard disks access (green)

 

 

 

 

 

Power (orange / green / yellow)

 

 

 

 

 

CSS (yellow)

 

 

 

 

 

HDD (orange)

 

 

 

 

 

PSU (orange)

 

 

 

 

 

TEMP (orange)

 

 

 

 

 

CPU (orange)

 

 

 

 

 

MEM (orange)

 

 

 

 

 

FAN (orange)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26

Operating Manual

TX1320 M1

Loading...