System Configuration Guide (V.6)
(November / 1999)
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------Notes |
P2 |
teamserver HS900 ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
P9 |
teamserver M800 series -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
P11 |
teamserver L800 series --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
P13 |
teamserver G800 series -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
P14 |
teamserver C800 series--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
P15 |
teamserver C300 series--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
P16 |
teamserver C350ie --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
P17 |
teamserver Network Cards----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
P17 |
teamserver Internal Devices --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
P18 |
teamserver External Devices -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
P19 |
teamserver Rackmount --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
P20 |
Hardware --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
P21 |
|
|
Index
The numbers on the left hand side of each page correspond to the various options available with teamservers as follows :
CPU slot
RAM module slot
3.5 inch HDD Bay
5 inch Bay
RS-232C
PCI slot
ISA slot
Redundant PSU
Others
Key to
Or |
And |
|
1
NOTES
This System Configuration Guide (V.6) introduces PentiumIIl 450MHz, 500MHz, 550MHz, 600MHz and Pentiumlll Xeon 550MHz models and withdraws all old models.
Please refer to http://www.fujitsu.co.jp/hypertext/InfoPro/msp/teamserver/config.html for old models.
Mounting internal devices in HS900
In HS900, there are two HDD bays (9GB/18GB/36GB disks are available) as system disks.
Storage System (GP5UR1DC4) is required for data storage.
HS900 has no internal 5" bay in chassis, so Backup Cabinet (GP5UR1BC1) is required to mount backup devices.
Mounting internal HDDs in M800i
SCSI Card (GP5-127) or RAID Card (GP5-144/146) is required to setup hard disks.
Storage System (GP5UR1DC4) is required when more than 7HDDs are installed. 14HDDs in total can be mounted in Pedestal version.
Mounting internal HDDs in L800i
L800i have eight HDD bays and up to six 36.4GB HDD can be mounted.
36.4GB HDD cannot be mounted in bays #7 and #8. However 18.2GB HDD can be mounted.
Mounting internal HDDs in G800i, C800i and C300i (except C850ie and C350ie)
G800i, C800i and C300i (except C850ie and C350ie) have eight HDD bays and 18.2GB HDD (1"height) can be mounted.
RCI(Remote Console Interface)
RCI(Remote Console Interface) support
The figure below indicates the availability of the RCI function on each server type.
O: Available(Std.), ●: Available(Opt.), X : N/A -: No server product type
Product |
Pedestal |
Rack |
C300 series |
X |
- |
C800 series |
X |
X |
G800 series |
X |
O |
L800 series |
● |
O |
M800 series |
O |
O |
HS900 |
- |
O |
Restriction of Operating System (M800i/HS900)
Windows NT Server 4.0 supports up to 4CPUs and 4GB of memory.
Windows NT Server 4.0 Enterprise Edition is required for more than 4CPUs and 4GB of Memory.
2
NOTES
Mounting additional memory
(HS900)
A memory board with 16slots is standard equipment and up to 16GB memory can be mounted. When you use over 16memory slots, an additional Memory Board (GP5-RB201) is required. When using two memory boards in HS900, the same memory size must be mounted on each board.
(M800i)
Memory must be expanded in bank units by mounting four similar capacity DIMMs in one bank. DIMMs must also be mounted in ascending order of memory capacity alternately on the two RAM base cards.
(L800i)
Mount the same capacity DIMM's in units of four. (Mounting of DIMM's with different capacities or a set of less than four DIMM's is not allowed) Mount the DIMM's in ascending order of their capacity. Use DIMM slots in the order from bank A (J1 to J4) to bank D (J13 to J16)
(G800i/C800i/C300i)
The motherboard has four slots for RAM modules (including standard equipment), install RAM modules in slot number order. (teamserver C3xxi has three slots)
Additional PSU in G800i
When a DLT unit (GP5-DL351) is mounted, an additional PSU (total two PSU) is required.
The restriction of the mount of 2 CPUs, 5HDD or 3 PCIs is cancelled.
S.M.A.R.T.function
S.M.A.R.T. function is available in the conbinations shown below:
■ : Corresponds , x:Does not correspond , -:N/A
|
|
|
|
Internal Hard disk units |
|
|
|
|
|
|
|
Hard disk cabinet |
|
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
IDE |
|
|
|
|
|
SCSI Hard disks |
|
|
|
|
|
|
GP5UR1DC4/GP5MS622A |
|
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Models |
Standard |
Standard |
|
SCSI card |
|
|
|
|
|
RAID card |
|
|
SCSI card |
|
|
RAID card |
|||
equipment |
equipment |
|
|
|
|
|
|
|
|
|
|
||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
GP5-125 |
GP5-126 |
GP5-127 |
GP5U141 |
GP5U142 |
GP5-143 |
GP5-144 |
GP5-146 |
GP5-125 |
GP5-126 |
GP5-127 |
GP5U141 |
GP5-144 |
GP5-146 |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
C300i (GP5C300-375) |
■ |
- |
■ |
- |
|
- |
|
x |
- |
■ |
- |
|
- |
■ |
- |
- |
x |
- |
- |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
C300i (GP5C377-379) |
■ |
- |
- |
■ |
|
- |
|
x |
- |
■ |
- |
|
- |
- |
- |
■ |
x |
- |
- |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
C800i |
- |
■ |
- |
- |
|
- |
|
x |
- |
■ |
- |
|
- |
■ |
- |
- |
x |
- |
- |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
G800i |
- |
■ |
- |
- |
|
- |
|
- |
x |
- |
■ |
|
■ |
- |
- |
■ |
x |
■ |
■ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
L800i |
- |
■ |
- |
- |
|
- |
|
- |
- |
- |
■ |
|
■ |
- |
- |
■ |
- |
■ |
■ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
M800i |
- |
- |
- |
- |
|
■ |
|
- |
- |
- |
■ |
|
■ |
- |
- |
■ |
- |
■ |
■ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
HS900 |
- |
■ |
- |
- |
|
- |
|
- |
- |
- |
■ |
|
■ |
- |
- |
■ |
- |
■ |
■ |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3
NOTES
Hard disk cabinet/RAID card/SCSI card
●Hard disk cabinet
GP5MS622A: Up to four can be connected to C300i, C800i, G800i and L800i. : Up to six can be connected to M800i.
Note: The Operating System must be installed on an internal hard disk.
●RAID card (GP5U141/GP5-144/GP5-146)
Up to two Hard disk cabinets can be connected with one RAID card. (Up to three can be connected with one GP5-144 card)
When connecting two GP5MS622A, GP5-144 RAID card is reguired on G800i, L800i, M800i and HS900. One GP5U141 cannot be used to connect external disk array (Hard disk cabinet) and internal disk array. One GP5-146 in G/L800i cannot be used to connect external disk array (Hard disk cabinet) and internal disk array.
One RAID card can not be used for botn internal and external array configuration. 2 RAID cards are reguired in this case.
GP5-144/146 can only be used with GP5-144/146, they cannot be mixed with
GP5U141/142/-143.
Up to two GP5-146 can be used for internal array configuration in G800i.
When connecting three RAID cards in G800i, the internal HDD must be connected using GP5-144.
●RAID card (GP5U142/GP5-143) Only for use with internal HDD.
Only one RAID card can be used per server.
●SCSI card (GP5-125/GP5-126/GP5-127)
Internal and external devices cannot be connected to the same SCSI card.
Maximum number of daisy chain connections allowed :
(1) Up to four external devices (but not Hard disk cabinets) can be connected by daisy chain. (2)Only one Hard disk cabinet can be connected. (Daisy chain connection is not available)
Disk array configuration
• Physical pack • • • • • • • • • • • • • • • • |
A collection of physical HDDs comprising a RAID. |
• Logical drive • • • • • • • • • • • • • • • • • |
Logical drive (ex. D: ) seen by the Operating System. |
• Partition • • • • • • • • • • • • • • • • • • • • • • • |
One of the logical access units into which a logical drive is divided. |
Physical pack |
|
|
|
HDD |
HDD |
HDD |
HDD |
Partition 1 |
|
|
|
Partition 2 |
|
|
|
<Restrictions> |
|
|
|
(1)Physical pack must contain the same type(size) of HDDs.
(2)Maximum logical drive size is 2TB (GP5U141/U142/-143/-144/-146).
Logical drive A
Logical drive B
* Drives can be divided into partition.
Logical drive C
4
NOTES
(3) The number of HDDs comprising a physical pack is as shown below.
RAID Level
RAID 0
RAID 1 |
|
RAID 5 |
) |
) )
Discription
The data is broken down into blocks,each on a separate disk drive
Duplicates the disk and writes
the same data onto two disks.
The data is broken down into blocks and each blocks is written together with parity bits on a separate disk drive.
(
(
(
HDDs
-2~8
-2
-3~8
|
) |
Duplicates the disk and broken |
( |
- 3~8 |
RAID 6 |
down into blocks, each on a |
separate disk. (RAID0+1)
(4)The same RAID level must be use when dividing a physical pack into a number of logical drives.
(5)A physical pack must contain only HDDs which are connected by the same RAID card.
(6)A RAID card can support more than one physical pack. ( even if different RAID levels)
(7)Internal and external array devices cannot be connected to the same RAID card. (except for M8xx)
Additional bus-slots
The number of bus-slots which can be used depends on each model.
Capacity of logical drives
The capacity of logical drive is same as the capacity of connected HDD.
The capacity of the logical drive is half the capacity of connected HDD.
The capacity of each logical drive is the number of connected HDDs - 1).
The capacity of each logical drive is the half the capacity of connected HDD. (GP5-143/144)
Product |
Number of standard bus-slots |
Product ID |
REMARKS |
|
|
|
|
|
|
HS900 |
PCI(64bit-66MHz)x4 |
GP5T9A32R |
|
Two PCIs(64bit-33MHz) are used for standard LAN card and |
|
PCI(64bit-33MHz)x6 |
GP5T9A22R |
|
standard RAID card. |
|
|
|
|
|
M890ie |
PCI(64bit)x5 |
GP5M895AL |
GP5M895BL |
LAN card is mounted in a PCI(32bit)slot. |
M880ie |
PCI(32bit)x5 |
GP5M885AL |
GP5M885BL |
|
|
PCI/ISA(32bit)x1 |
|
|
|
|
|
|
|
|
L890ie |
PCIx6 |
GP5L895L |
GP5L895LR |
LAN card is mounted in a PCIslot. |
L880ie |
PCI/ISAx1 |
GP5L885L |
GP5L885LR |
|
L870ie |
|
GP5L875L |
GP5L875LR |
|
|
|
|
|
|
G870ix |
PCIx4 |
GP5G879L |
GP5G879LR |
All of the slots are available |
G870ie |
PCI/ISAx1 |
GP5G878L |
GP5G878LR |
|
G870i |
ISAx1 |
GP5G877L |
GP5G877LR |
|
|
|
|
|
|
C870ix |
PCIx3 |
GP5C876 |
GP5C876R |
All of the slots are available |
C870ie |
ISAx2 |
GP5C875 |
GP5C875R |
|
C870i |
|
GP5C871 |
GP5C871R |
|
C850ie |
|
GP5C855 |
GP5C855R |
|
|
|
|
|
|
C370ix |
PCIx4 |
GP5C379 |
|
All of the slots are available |
C370ie |
ISAx1 |
GP5C378 |
|
|
C370i |
|
GP5C377 |
|
|
C350ie |
|
GP5C355 |
|
|
|
|
|
|
|
5
NOTES
Number of mountable optional cards
HS900
|
|
|
Maximum |
|
REMARKS |
Cards |
Product ID |
Bus |
number of |
Total |
|
|
|
|
cards mounted |
|
|
RAID card |
Standard |
|
|
|
|
(Ultra2 Wide LVB) |
equipment |
PCI64 |
1 |
|
|
RAID card |
|
|
|
|
|
(Ultra2 Wide LVD) |
GP5-144 |
PCI64 |
7 |
8 |
|
RAID card |
|
|
|
|
|
(Ultra2 Wide LVD) |
GP5-146 |
PCI64 |
7 |
|
|
SCSI card |
|
|
|
|
|
(Ultra2 Wide LVD) |
GP5-127 |
PCI64 |
6 |
|
|
SCSI card |
|
|
|
|
|
(Ultrawide Diff) |
GP5-123 |
PCI64 |
2 |
|
For external disk array |
|
|
|
|
|
|
Fibre Channel Card |
GP5-FC101 |
PCI64 |
2 |
2 |
|
|
|
|
|
|
|
LAN card (1000Base-SX) |
GP5-183 |
PCI64 |
1 |
|
|
LAN card (100Base-TX) |
GP5-185 |
PCI64 |
3 |
4 |
|
|
Standard |
|
|
|
|
LAN card (100Base-TX) |
equipment |
PCI64 |
1 |
|
|
|
|
|
|
|
|
Server Monitor Module |
GP5USM103 |
PCI64 |
1 |
1 |
|
|
|
|
|
|
|
M800i
|
|
|
Maximum |
|
REMARKS |
Cards |
Product ID |
Bus |
number of cards |
Total |
|
|
|
|
mounted |
|
|
RAID card |
|
|
|
|
|
(Ultra2 Wide LVD) |
GP5-144 |
PCI64 |
5 |
5 |
|
RAID card |
|
|
|
|
|
(Ultra2 Wide LVD) |
GP5-146 |
PCI64 |
4 |
|
|
SCSI card |
|
|
|
|
|
(Ultra2 Wide LVD) |
GP5-127 |
PCI64 |
5 |
|
|
SCSI card |
|
|
|
|
|
(Ultrawide Diff) |
GP5-123 |
PCI64 |
2 |
|
For external disk array |
|
|
|
|
|
|
Fibre Channel Card |
GP5-FC101 |
PCI64 |
2 |
2 |
|
|
|
|
|
|
|
LAN card (1000Base-SX) |
GP5-183 |
PCI64 |
1 |
|
|
LAN card (100Base-TX) |
GP5-185 |
PCI32 |
3 |
4 |
|
|
|
||||
|
Standard |
|
|
|
|
LAN card (100Base-TX) |
equipment |
PCI32 |
1 |
|
Mounted in PCI slot3(fixed) |
|
|
|
|
|
|
Server Monitor Module |
GP5USM102 |
PCI32 |
1 |
1 |
|
|
|
|
|
|
|
* Up to six cards can be mounted when an ISA card is used.
L800i
|
|
|
Maximum |
|
|
REMARKS |
|||
Cards |
Product ID |
Bus |
number of |
Total |
|||||
|
|
|
cards mounted |
|
|
|
|||
SCSI card |
|
|
|
|
|
|
|
|
|
(Ultrawide Diff) |
GP5-123 |
PCI |
2 |
|
|
|
|
|
For external disk array |
SCSI card |
|
|
|
|
3 |
|
|
|
GP5-127can beused to connect internal |
(Ultra2 Wide LVD) |
GP5-127 |
PCI |
3 |
|
|
|
|
|
SCSI devices(GP5-DL351,GP5-ML301). |
RAID card |
|
|
|
|
|
|
7* |
|
|
(Ultra2 Wide LVD) |
GP5-144 |
PCI |
3 |
|
|
|
|
|
|
|
|
|
|
|
|
||||
RAID card |
|
|
|
|
|
|
|
|
|
(Ultra2 Wide LVD) |
GP5-146 |
PCI |
2 |
|
|
|
|
|
|
Fibre Channel Card |
GP5-FC101 |
PCI |
2 |
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
LAN card (1000Base-SX) |
GP5-183 |
PCI |
1 |
|
4 |
|
|
|
It must be mounted in PCI-A2 |
|
|
|
|
||||||
|
|
|
|
|
|
|
|
||
LAN card (100Base-TX) |
GP5-185 |
PCI |
3 |
|
|
|
|
|
|
|
Standard |
|
|
|
|
|
|
|
|
LAN card (100Base-TX) |
equipment |
PCI |
1 |
|
|
|
|
|
Mounted in PCI-A1(fixed) |
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
Server Monitor Module |
GP5USM102 |
PCI |
1 |
|
|
|
|
|
It must be mounted in PCI-A3 |
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
* Up to six cards can be mounted when an ISA card is used.
G800i
|
|
|
Maximum |
|
|
|
REMARKS |
||
Cards |
Product ID |
Bus |
number of cards |
|
|
Total |
|||
|
|
|
mounted |
|
|
|
|
||
SCSI card |
|
|
|
|
|
|
|
|
|
(Ultrawide Diff) |
GP5-123 |
PCI |
2 |
|
|
|
|
|
For external disk array |
SCSI card |
|
|
|
|
|
|
|
|
Use for external SCSI devices |
(Ultra2 Wide LVD) |
GP5-127 |
PCI |
3 |
|
|
|
|
|
|
RAID card |
|
|
|
|
|
|
|
|
|
(Ultrawide SE) |
GP5U141 |
PCI |
2 |
|
|
|
|
|
Internal/external array configuration |
RAID card |
|
|
|
3 |
|
|
|
|
|
(Ultrawide) |
GP5U142 |
PCI |
1 |
|
|
|
|
|
Only for internal array configuration |
RAID card |
|
|
|
|
|
|
|
5 |
Internal/external array configuration |
(Ultra2 Wide LVD) |
GP5-144 |
PCI |
3 |
|
|
|
|
|
Cannot be used with GP5U141/142 |
RAID card |
|
|
|
|
|
|
|
|
Internal/external array configuration |
(Ultra2 Wide LVD) |
GP5-146 |
PCI |
2 |
|
|
|
|
|
Cannot be used with GP5U141/142 |
Fibre Channel Card |
GP5-FC101 |
PCI |
2 |
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
LAN card (1000Base-SX) |
GP5-183 |
PCI |
1 |
|
3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
LAN card (100Base-TX) |
GP5-184 |
PCI |
3 |
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
Server Monitor Module |
GP5USM102 |
PCI |
1 |
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
|
|
|
|
|
|
|
|
C800i
|
|
|
Maximum |
|
REMARKS |
|
Cards |
Product ID |
Bus |
number of |
Total |
||
|
|
|
cards mounted |
|
|
|
|
|
|
|
|
|
|
RAID card |
|
|
|
|
|
|
(Ultrawide SE) |
GP5U141 |
PCI |
2 |
2 |
3 |
Internal/external array configuration |
RAID card |
|
|
|
|
|
|
(Ultrawide SE) |
GP5-143 |
PCI |
1 |
|
|
Only for internal array configuration |
SCSI card |
GP5-125 |
PCI |
3 |
|
|
Only for external SCSI devices |
|
|
|
|
|
|
|
LAN card (1000Base-SX) |
GP5-183 |
PCI |
1 |
|
3 |
|
LAN card (100Base-TX) |
GP5-185 |
PCI |
3 |
|
|
|
Server Monitor Module |
GP5USM102 |
PCI |
1 |
|
|
|
|
|
|
|
|
|
|
C300i (GP5C377-379)
|
|
|
Maximum |
|
REMARKS |
Cards |
Product ID |
Bus |
number of cards |
Total |
|
|
|
|
mounted |
|
|
|
|
|
|
|
|
SCSI card |
GP5-126 |
PCI |
1 |
3 |
|
|
|
|
|
|
|
SCSI card |
GP5-127 |
PCI |
3 |
|
|
|
|
|
|
|
|
RAID card |
|
|
|
|
|
(Ultrawide SE) |
GP5U141 |
PCI |
2 |
|
Internal/external array configuration |
|
|
|
|
|
|
RAID card |
|
|
|
|
|
(Ultra2 Wide LVD) |
GP5-143 |
PCI |
1 |
|
|
|
|
|
|
|
|
LAN card (100Base-TX) |
GP5-185 |
PCI |
3 |
3 |
|
|
|
|
|
|
|
Server Monitor Module |
GP5USM102 |
PCI |
1 |
1 |
|
|
|
|
|
|
|
C300i (GP5C300-375)
|
|
|
Maximum |
|
REMARKS |
Cards |
Product ID |
Bus |
number of |
Total |
|
|
|
|
cards mounted |
|
|
SCSI card |
GP5-125 |
PCI |
3 |
3 |
|
|
|
|
|
|
|
RAID card |
|
|
|
|
|
(Ultrawide SE) |
GP5U141 |
PCI |
2 |
|
Internal/external array configuration |
|
|
|
|
|
Only for internal array configuration |
|
|
|
|
|
|
|
|
|
|
|
(Cannot be used with GP5-143) |
RAID card |
|
|
|
|
Only for internal array configuration |
(Ultra2 Wide LVD) |
GP5-143 |
PCI |
1 |
|
(Cannot be used with GP5U142) |
LAN card (100Base-TX) |
GP5-185 |
PCI |
3 |
3 |
|
Server Monitor Module |
GP5USM102 |
PCI |
1 |
1 |
|
6
NOTES
The differentiation between current models and new models
1. Connectivity/Use of new product options with older models
I. The figure below indicates the applicability of new options on previous (released before August, 1999) models
Figure1 |
Product |
Option |
Product ID |
Applicable |
Remarks |
|
|
|
|
to older |
|
|
|
Hard disk drive-9GB |
GP5-HD9G3 |
O |
Please refer to Figure2 |
|
|
|
|
|
|
|
C300series |
Hard disk drive-9GB |
GP5-HD9G3B |
O |
Please refer to Figure2 |
|
|
|
|
|
|
|
|
Hard disk drive-18GB |
GP5-HD8G1 |
O |
|
|
|
|
|
|
|
|
|
Hard disk drive-18GB |
GP5-HD8G1B |
O |
|
|
|
|
|
|
|
|
|
Hard disk drive-13GB |
GP5-HD3E1 |
O |
|
|
|
|
|
|
|
|
|
LAN card |
GP5-185 |
O |
Successor of GP5-182/184 |
|
|
|
|
|
|
|
|
SCSI card |
GP5-127 |
X |
|
|
|
|
|
|
|
|
|
SCSI card |
GP5-126 |
X |
|
|
|
|
|
|
|
|
|
RAID card |
GP5-143 |
O |
However, used as Ultrawide SCSI interface in older models |
|
|
|
|
|
|
|
|
SCSI cable |
GP5-839 |
X |
|
|
|
|
|
|
|
|
|
|
GP5-840 |
X |
|
|
|
|
|
|
|
|
|
|
GP5-841 |
O |
Successor of GP5-838 |
|
|
|
|
|
|
|
|
Hard disk cabinet |
GP5MS622A |
O |
Successor of GP5MS621A |
|
|
|
|
|
|
|
C800series |
Hard disk drive-9GB |
GP5-HD9G3 |
O |
Please refer to Figure2 |
|
|
|
|
|
|
|
|
Hard disk drive-9GB |
GP5-HDH96 |
O |
Please refer to Figure2 |
|
|
|
|
|
|
|
|
Hard disk drive-18GB |
GP5-HD8G1 |
O |
Please refer to Figure2 |
|
|
|
|
|
|
|
|
Hard disk drive-18GB |
GP5-HDH83 |
O |
Please refer to Figure2 |
|
|
|
|
|
|
|
|
LAN card |
GP5-185 |
O |
Successor of GP5-182/184 |
|
|
|
|
|
|
|
|
Hard disk cabinet |
GP5S622A |
O |
Successor of GP5MS621A |
|
|
|
|
|
|
|
G800 series |
Hard disk drive-9GB |
GP5-HDH96 |
O |
Please refer to Figure2 |
|
|
|
|
|
|
|
|
Hard disk drive-18GB |
GP5-HDH83 |
O |
Please refer to Figure2 |
|
|
|
|
|
|
|
|
LAN card |
GP5-185 |
O |
Successor of GP5-182/184 |
|
|
|
|
|
|
|
|
SCSI card |
GP5-127 |
O |
Successor of GP5-125/GP5-126 |
|
|
|
|
|
|
|
|
RAID card |
GP5-146 |
O |
Successor of GP5-145 with Windows NT only |
|
|
|
|
|
For Netware/Intranetware, please use GP5-145 |
|
|
|
|
|
|
|
|
Hard disk cabinet |
GP5MS622A |
O |
Successor of GP5MS621A |
|
|
DLT unit |
GP5-DL351 |
O |
Two PSU (one is standard) are required when mounting GP5-DL351 |
|
|
|
|
|
|
|
L800 series |
Hard disk drive-9GB |
GP5-HDH97 |
O |
Please refer to Figure2 |
|
|
|
|
|
|
|
|
Hard disk drive-9GB |
GP5-HDH98 |
O |
Please refer to Figure2 |
|
|
|
|
|
|
|
|
Hard disk drive-18GB |
GP5-HDH84 |
O |
Please refer to Figure2 |
|
|
|
|
|
|
|
|
Hard disk drive-18GB |
GP5-HDH85 |
O |
Please refer to Figure2 |
|
|
|
|
|
|
|
|
Hard disk drive-36GB |
GP5-HDH61 |
O |
New |
|
|
|
|
|
|
|
|
LAN card |
GP5-185 |
O |
Successor of GP5-182/184 |
|
|
|
|
|
|
|
|
SCSI card |
GP5-127 |
O |
Successor of GP5-125/GP5-126 |
|
|
|
|
|
|
|
|
RAID card |
GP5-146 |
O |
|
|
|
|
|
|
|
|
|
Hard disk cabinet |
GP5MS622A |
O |
Successor of GP5MS621A |
|
|
|
|
|
|
|
|
RCI card |
GP5-RC101 |
O |
New for Pedestal type, Standard equipment for Rackmount type |
|
|
|
|
|
|
|
M800 series |
Hard disk drive-9GB |
GP5-HDH97 |
O |
Please refer to Figure2 |
|
|
|
|
|
|
|
|
Hard disk drive-9GB |
GP5-HDH98 |
O |
Please refer to Figure2 |
|
|
|
|
|
|
|
|
Hard disk drive-18GB |
GP5-HDH84 |
O |
Please refer to Figure2 |
|
|
|
|
|
|
|
|
Hard disk drive-18GB |
GP5-HDH85 |
O |
Please refer to Figure2 |
|
|
|
|
|
|
|
|
Hard disk drive-36GB |
GP5-HDH61 |
O |
New |
|
|
|
|
|
|
|
|
LAN card |
GP5-185 |
O |
Successor of GP5-182/184 |
|
|
|
|
|
|
|
|
SCSI card |
GP5-127 |
O |
Successor of GP5-125/GP5-126 |
|
|
|
|
|
|
|
|
RAID card |
GP5-146 |
O |
|
|
|
|
|
|
|
|
|
Hard disk cabinet |
GP5MS622A |
O |
Successor of GP5MS621A |
|
|
|
|
|
|
II. Ultra wide or Ultra2 Wide on C300 series
The new C300 series (GP5C377, GP5C378, GP5C379) supports Ultra2 Wide SCSI.
To use new C300 series as an Ultra2 Wide system, Ultra2 Wide HDD, Ultra2 Wide SCSI (RAID) card and Ultra2 Wide SCSI cable are required
Previous models (GP5C300 to GP5C375 - Released Jul,1999) cannot support Ultra2 Wide even if Ultra2 Wide SCSI HDD, card & cable are mounted.
For connection details, please refer to "Available SCSI cards for C300i"
7
NOTES
Available SCSI card for C300i
(1) GP5C377/378/379 (Ultra2 Wide)
Connected device |
|
SCSI card |
Channel |
Cable |
Remarks |
Internal HDD |
|
GP5-126 |
Internal Channel |
GP5-839 |
Up to four HDDs |
|
|
|
(68pin) |
|
|
Internal Backup device |
|
GP5-126 |
Internal Channel |
GP5-841 |
|
|
|
|
(50pin) |
|
|
|
|
|
|
|
|
|
|
GP5-127 |
Internal Channel |
GP5-840 |
When using EIDE HDD or |
|
|
|
(68pin) |
|
RAID, GP5-127 must be |
|
|
|
|
|
used instead of GP5-126* |
|
|
|
|
|
|
Hard disk cabinet |
|
GP5-127 |
External Channel |
GP5MU823A |
|
|
|
|
(68pin) |
|
|
*SCSI card (GP5-126) is required for connecting SCSI HDD |
|
|
|||
(2) GP5C300-375 (Ultra wide) |
|
|
|
|
|
Connected device |
|
SCSI card |
Channel |
Cable |
Remarks |
Internal HDD (SCSI) |
|
GP5-125 |
Internal Channel |
GP5-837 |
Up to four HDDs |
|
|
|
(68pin) |
|
|
|
|
|
|
|
|
Internal Backup device |
|
GP5-125 |
Internal Channel |
GP5-841 |
|
|
|
|
(50pin) |
|
|
|
|
|
|
|
|
Hard disk cabinet |
|
GP5-125 |
External Channel |
GP5MU823A |
|
|
|
|
(68pin) |
|
|
|
|
|
|
|
|
# of SCSI Channel of each SCSI card is as below:
SCSI card |
Internal |
External |
GP5-125 |
2(68pin+50pin) |
1(68pin) |
GP5-126 |
2(68pin+50pin) |
1(68pin) |
GP5-127 |
1(68pin) |
1(68pin) |
2.Internal HDD
The HDD line-up has changed. The figure below indicates each product and its successor. Current and successor HDDs of the same size can be used together in the same physical pack.
Figure 2
Main unit |
Product |
Current HDD |
Succesor HDD |
Remarks |
|
|
Product ID |
Product ID |
|
C300 series |
Hard disk drive-4GB |
GP5-HD4G5 |
GP5-HD4G51 |
|
|
|
|
GP5-HD4G5B |
For mounting in 5" bay |
|
Hard disk drive-9GB |
GP5-HD9G2 |
GP5-HD9G3 |
|
|
|
|
GP5-HD9G3B |
For mounting in 5" bay |
C800 series |
Hard disk drive-4GB |
GP5-HD4G5 |
GP5-HD4G51 |
|
|
Hard disk drive-4GB |
GP5-HDH44 |
GP5-HDH461 |
Can be used with GP5-HDH46 |
|
Hard disk drive-9GB |
GP5-HD9G3 |
GP5-HD9G3 |
|
|
Hard disk drive-9GB |
GP5-HDH92 |
GP5-HDH96 |
Can be used with GP5-HDH95 |
G800 series |
Hard disk drive-4GB |
GP5-HDH44 |
GP5-HDH461 |
Can be used with GP5-HDH46 |
|
Hard disk drive-4GB |
GP5-HDH46 |
GP5-HDH461 |
|
|
Hard disk drive-9GB |
GP5-HDH92 |
GP5-HDH96 |
Can be used with GP5-HDH95 |
|
Hard disk drive-9GB |
GP5-HDH95 |
GP5-HDH96 |
|
L800 series |
Hard disk drive-4GB |
GP5-HDH45 |
GP5-HDH451 |
|
M800 series |
Hard disk drive-9GB |
GP5-HDH93 |
GP5-HDH97 |
|
|
Hard disk drive-9GB |
GP5-HDH94 |
GP5-HDH98 |
|
|
Hard disk drive-18GB |
GP5-HDH81 |
GP5-HDH84 |
|
|
Hard disk drive-18GB |
GP5-HDH82 |
GP5-HDH85 |
|
Successor products of the same size can be used as additional HDD in a physical pack that contains current/previous products.
8
System Configuration
teamserver HS900
teamserver HS900 series
CPU: Pentium® lll Xeon™ (550MHz) x 2(~8) , Cache (L1+L2) : 32KB+2MB/1MB, Internal Hard disk bay:(Hot-plug) 2bays,
2 x Ultra2 Wide SCSI Onboard, 2ch RAID Card, CD-ROM, LAN Card (Std.), Redundant Power Supply (Std.)/FAN (Std.), Intel LANDesk® Server Manager/Servervisor, ServerWizard
|
GP5T9A32R |
[Rackmount Type] |
|
||
|
|
2CPU, Memory:1GB(ECC), HDD:Option |
|
GP5T9A22R |
[Rackmount Type] |
|
|
2CPU, Memory:1GB(ECC), HDD:Option |
|
|
|
[Rackmount type]
CPU
Standard : 2CPUs |
Max : 8CPUs |
q
|
|
|
|
|
|
|
|
|
|
Memory |
Max. memory: 32GB |
|
|
|
|
|
|
|
|
w |
|
|
Standard memory : 1GB (128MB-DIMM 8) |
w |
Additiond Memory Board |
|
GP5-RB201 |
Internal Hard Disk
Up to two HDDs can be mounted in the main unit
SCSI on board
y
RAID Card (GP5-146 : std.)
Connect with Storage System
y
SCSI Card (Ultra2 Wide) |
|
|
|
|
|
|
SCSI Cable(3m) |
||
GP5-127 |
|
|
||
|
|
GP5MU823A |
||
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SCSI
GP5S-833
CPU Field Upgrade Kit (Pentium®III Xeon™-550MHz (2MB) 1)
GP5-FG203T
CPU Field Upgrade Kit (Pentium®III Xeon™-550MHz (1MB) 1)
GP5-FG202T
Additional Memory - 256MB (128MB-DIMM 2)
GP5-RM25J
Additional Memory - 512MB (256MB-DIMM 2)
GP5-RM51J
Memory - 1024MB (512MB-DIMM 2)
Additional Memory - 2048MB (1024MB-DIMM 2)
GP5-RM2J
Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
GP5-HDH98T
Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
GP5-HDH85T
Hard Disk Drive - 36GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
GP5-HDH61T
Hard Disk Drive - 9GB (Ultra2 Wide.10,000rpm)
Hard Disk Drive - 18GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
GP5-HDH85
Hard Disk Drive - 36GB (Ultra2 Wide.10,000rpm)
(Hot Plug)
- 9GB (Ultra2 Wide.7,200rpm)
SCSI Cable(10m)
GP5S-834
Redundant Power Supply Unit GP5U R1PU1
9