Fujitsu AOU18RXQ, AWU18CXQ, AOU18CXQ, AWU24RXQ, AWU24CXQ User Manual

...
0 (0)

OPERATING MANUAL

ROOM AIR CONDITIONER

WALL MOUNTED TYPE

Indoor Unit

AWU18CXQ

AWU18RXQ

AWU24CXQ

AWU24RXQ

Outdoor Unit

AOU18CXQ

AOU18RXQ

AOU24CXQ

AOU24RXQ

KEEP THIS MANUAL

FOR FUTURE REFERENCE

FUJITSU GENERAL LIMITED

P/N9373459019

CONTENTS

SAFETY PRECAUTIONS ..........................................

1

FEATURES AND FUNCTIONS .................................

2

NAME OF PARTS ......................................................

3

PREPARATION ..........................................................

5

OPERATION ..............................................................

6

AIR CLEANING OPERATION ....................................

8

TIMER OPERATION ..................................................

9

MANUAL AUTO OPERATION ................................

10

ADJUSTING THE DIRECTION OF AIR CIRCULATION .....

11

SWING OPERATION ............................................

12

CLEANING AND CARE ........................................

13

CLEANING THE ELECTRONIC AIR CLEAN UNIT .....

14

SELECTING THE REMOTE CONTROL UNIT

 

SIGNAL CODE .....................................................

16

TROUBLESHOOTING ..........................................

17

OPERATING TIPS .................................................

18

SAFETY PRECAUTIONS

Before using the appliance, read these “PRECAUTIONS” thoroughly and operate in the correct way.

The instructions in this section all relate to safety; be sure to maintain safe operating conditions.

“DANGER”, “WARNING” and “CAUTION” have the following meanings in these instructions:

DANGER!

This mark indicates procedures which, if improperly performed, are most likely to

result in the death of or serious injury to the user or service personnel.

 

 

 

WARNING!

This mark indicates procedures which, if improperly performed, might lead to the

death or serious injury of the user.

 

 

CAUTION!

This mark indicates procedures which, if improperly performed, might possibly result

in personal harm to the user, or damage to property.

 

 

 

DANGER!

CAUTION!

1

Do not attempt to install this air conditioner by yourself.

This unit contains no user-serviceable parts. Always consult authorized service personnel for repairs.

When moving, consult authorized service personnel for disconnection and installation of the unit.

Do not become over-exposed to cold air by staying in the direct path of the air flow of the air conditioner for extended periods of time.

Do not insert fingers or objects into the outlet port or intake grilles.

Do not start and stop air conditioner operation by turning off the electrical breaker or disconnecting the power supply plug and so on.

Take care not to damage the power supply cord.

In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical breaker or disconnect the power supply plug, and consult authorized service personnel.

Provide occasional ventilation during use.

Do not direct air flow at fireplaces or heating apparatus.

Do not climb on, or place objects on, the air conditioner.

Do not hang objects from the indoor unit.

Do not set flower vases or water containers on top of air conditioners.

Do not expose the air conditioner directly to water.

Do not operate the air conditioner with wet hands.

Do not pull power supply cord.

Turn off power source when not using the unit for extended periods.

Always turn off the electrical breaker or disconnect the power supply plug whenever cleaning the air conditioner or the air filter.

Connection valves become hot during Heating; handle with care.

Check the condition of the installation stand for damage.

Do not place animals or plants in the direct path of the air flow.

Do not drink the water drained from the air conditioner.

Do not use in applications involving the storage of foods, plants or animals, precision equipment, or art works.

Do not apply any heavy pressure to radiator fins.

Operate only with air filters installed.

Do not block or cover the intake grille and outlet port.

Ensure that any electronic equipment is at least one metre away from either the indoor or outdoor units.

Avoid installing the air conditioner near a fireplace or other heating apparatus.

When installing the indoor and outdoor units, take precautions to prevent access by infants.

Do not use inflammable gases near the air conditioner.

When restarting the air conditioner after a long period of disuse, turn the power switch on at least 12 hours before starting the unit.

When cleaning the heat exchanger, do not get any water, liquid detergent, etc., on the electronic air clean filter. The filter may be damaged.

FEATURES AND FUNCTIONS

AUTOMATIC OPERATION

COOLING MODEL

Merely press the START/STOP button, and the unit will begin automatic operation in the Cooling or Dry mode as appropriate, in accordance with the thermostat setting and the actual temperature of the room.

HEAT & COOL MODEL (REVERSE CYCLE)

Merely press the START/STOP button, and the unit will begin automatic operation in either the Heating, Cooling or Monitor modes as appropriate, in accordance with the thermostat setting and the actual temperature of the room.

ELECTRONIC AIR CLEAN FILTER

Electrical power is used to charge the filter to remove contaminants from the air and to effectively collect dust and remove odors. It also helps to reduce the bacterial activity.

SLEEP TIMER

COOLING MODEL

When the SLEEP timer button is pressed during Cooling or Dry mode, the thermostat setting is gradually raised during the period of operation. When the set time is reached, the unit automatically turns off.

HEAT & COOL MODEL (REVERSE CYCLE)

When the SLEEP timer button is pressed during Heating mode, the air conditioner’s thermostat setting is gradually lowered during the period of operation; during Cooling or Dry mode, the thermostat setting is gradually raised during the period of operation. When the set time is reached, the unit automatically turns off.

WIRELESS REMOTE CONTROL UNIT

The WIRELESS REMOTE CONTROL UNIT allows convenient control of air conditioner operation.

OMNI-DIRECTIONAL AIR FLOW (SWING OPERATION)

Three-dimensional control over air direction swing is possible through dual use of both an UP/DOWN air direction swing and RIGHT/LEFT air direction swing. Since UP/DOWN air direction flaps operate automatically according to the operating mode of the unit, it is possible to set air direction based on the operating mode.

REMOVABLE INTAKE FILTER

The indoor unit’s INTAKE FILTER can be removed for easy cleaning and maintenance.

MILDEW-RESISTANT FILTER

The INTAKE FILTER has been treated to resist mildew growth, thus allowing cleaner use and easier care.

2

Fujitsu AOU18RXQ, AWU18CXQ, AOU18CXQ, AWU24RXQ, AWU24CXQ User Manual

NAME OF PARTS

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

Fig. 1

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

Fig. 2

 

 

 

 

 

4

 

 

 

 

 

3

 

 

 

 

 

B

 

 

 

0

 

7

6

5

8

 

 

A

 

Fig. 3

 

 

 

 

 

 

 

 

 

 

 

 

C

 

Fig. 5

 

 

 

 

 

 

 

F

 

 

 

 

D

9

 

 

 

 

 

 

 

 

 

E

Fig. 4

 

 

 

 

 

 

 

 

Fig. 6

 

 

 

 

 

 

 

Fig. 8

 

 

 

 

Fig. 7

 

 

 

 

3

 

 

 

 

 

Fig. 1 Indoor Unit

1 Operating Control Panel (Fig. 2)

2 MANUAL AUTO button

3 Remote Control Signal Receiver

4 Indicator Lamps (Fig. 3)

5 OPERATION Indicator Lamp

(green ......

COOL, DRY, FAN)

(red ..........

*HEAT)

6 TIMER Indicator Lamp (yellow)

7SWING Indicator Lamp (orange) (VERTICAL/HORIZONTAL SWING)

8AIR CLEAN Indicator Lamp (green)

If the TIMER indicator lamp flashes when the timer is operating, it indicates that a fault has occurred with the timer setting (See page 19 Auto Restart).

9 Intake Filter (Fig. 4)

; UP/DOWN Air Direction Flaps

A RIGHT/LEFT Air Direction Louvers

(behind UP/DOWN Air Direction Flaps)

B Drain Hose

C Electronic Air Clean Unit (Fig. 4)

Fig. 5 Outdoor Unit

D Intake Port

E Outlet Port

F Pipe Unit

 

Fig. 6 Remote Control Unit

 

 

 

 

 

 

 

 

 

 

G AIR CLEAN button

 

 

H MASTER CONTROL button

 

 

I SET TEMP./SET TIME buttons (

)

 

J Signal Transmitter

 

 

K TIMER button

 

 

L FAN CONTROL button

 

 

M START/STOP button

 

 

N AIR FLOW DIRECTION

 

 

VERTICAL SET button

 

 

O AIR FLOW DIRECTION

 

 

VERTICAL SWING button

 

 

P AIR FLOW DIRECTION

 

 

HORIZONTAL SET button

 

 

Q AIR FLOW DIRECTION

 

 

HORIZONTAL SWING button

 

 

R TIME ADJUST button

 

 

S ACL button

 

Rear side (Fig. 7)

TTEST RUN

Touch the two metal contacts with a metallic object to send the signal to perform a test run.

Perform a test run only when installing the air conditioner. If the signal to perform a test run is received during normal operation, the air conditioner’s thermostat will malfunction.

If the signal to perform a test run is received during normal operation, the unit will switch to the test operation mode and the indoor unit’s OPERATION and TIMER indicator lamps will flash simultaneously.

To stop the test operation mode, press the START/STOP button to stop the air conditioner.

U Remote Control Unit Display (Fig. 8) V Transmit Indicator

W Clock Display

X Operating Mode Display Y T imer Mode Display

Z Fan Speed Display

[ Temperature Set Display \ T imer Set Indicator

] Temperature Set Indicator

4

PREPARATION

Load Batteries (R03/LR03 × 2)

1

Press and slide the battery compartment lid on the re-

verse side to open it.

 

 

Slide in the direction of the arrow while pressing the mark.

2

Insert batteries.

 

Be sure to align the battery polarities (

) correctly.

3

Close the battery compartment lid.

Set the Current time

1

Press the TIME ADJUST button (Fig. 6 R).

Use the tip of a ball-point pen or other small object to press the button.

2

Use the (

) SET TIME buttons (Fig. 6 I) to adjust

the clock to the current time.

 

button: Press to advance the time.

 

button: Press to reverse the time.

 

(Each time the buttons are pressed, the time will be advanced/reversed in

 

one-minute increments; hold the buttons depressed to change the time

 

quickly in ten-minute increments.)

3

Press the TIME ADJUST button again.

This completes the time setting and starts the clock.

To Use the Remote Control Unit

The remote control unit must be pointed at signal receiver (Fig. 1 3) to operate correctly.

Operating range: About 7 meters.

When a signal is properly received by the air conditioner, a beeping sound will be heard.

If no beep is heard, press the remote control unit button again.

Remote Control Unit Holder

Insert

Slide up

 

Press in

Pull out

Screws

 

1 Mount the Holder. 2 Set the Remote Control Unit.

3 To remove the Remote

 

Control Unit (when use at

 

hand).

CAUTION!

Take care to prevent infants from accidentally swallowing batteries.

When not using the remote control unit for an extended period, remove the batteries to avoid possible leakage and damage to the unit.

If leaking battery fluid comes in contact with your skin, eyes, or mouth, immediately wash with copious amounts of water, and consult your physician.

Dead batteries should be removed quickly and disposed of properly, either by placing in a public battery collection receptacle, or by returning to appropriate authority.

Do not attempt to recharge dry batteries.

Never mix new and used batteries, or batteries of different types.

Batteries should last about one year under normal use. If the remote control unit’s operating range becomes appreciably reduced, replace the batteries and press the ACL button with the tip of a ballpoint pen or other small object.

5

Loading...
+ 14 hidden pages