Frigidaire FFHT1826LK, FFHT1817LS, FFHT2126LQ, FFHT1725LK, FFHT2116LS Wiring Diagram

...
0 (0)
Frigidaire FFHT1826LK, FFHT1817LS, FFHT2126LQ, FFHT1725LK, FFHT2116LS Wiring Diagram

PERFORMANCE DATA

NO LOAD & NO DOOR OPENINGS AT MID-POINT CONTROL SETTING

Capacitor Run or Induction Run

 

65°F (18°C) Ambient

90°F (32°C) Ambient

 

 

 

 

 

 

Operating Time

 

25 to 35%

45 to 55%

 

 

 

 

 

 

 

Freezer Temperature

 

2° to 8°F (-17° to -13°C)

0° to 5°F

(-18° to -15°C)

 

 

 

 

 

 

Refrigerator Temperature

 

35° to 40°F (2° to 4°C)

35° to 40°F (2° to 4°C)

 

 

 

 

 

 

 

Low Side Pressure (cut-in)

 

8 to 16 psig

( 55 to 110

8 to 16 psig

(55 to 110 kPa)

 

kPa)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low Side Pressure (cut-out)

 

1 to 4 psig (7 to 28 kPa)

1 to 4 psig (7 to 28 kPa)

 

 

 

 

 

 

High Side Pressure (last 1/3

 

110 to 120 psig (758 to

150 to 175 psig (1034 to 1207

cycle)

 

827 kPa)

 

 

kPa)

 

 

 

 

 

 

Wattage (last 1/3 cycle)

 

140 to 185

140 to 185

 

 

 

 

 

 

Amps (running)

 

1.1 to 1.6

1.1 to 1.6

 

 

 

 

 

 

Base Voltage

 

115 vac (127 vac max)

115 vac (127 vac max)

 

 

 

 

 

 

 

 

DEFROST SPECIFICATIONS

 

 

 

 

 

 

 

Cabinet Size

 

Thermostat

 

Heater

 

 

 

 

 

 

 

Cut-in

Cut-out

Watts

 

Ohms

 

 

 

 

 

 

 

 

 

 

18’ & 21’

 

25°F

47°F (8°C)

375

 

35

 

(-4°C)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14’, 15’ & 17’

 

25°F (-4°C

47°F (8°C)

325

 

41

 

 

 

 

 

 

 

Mechanical Timer - Defrost 30 minutes every 10 hours of compressor run time. Electronic Timer (ADC) - Defrost up to 24 minutes every 6-72 hours of compressor run time.

CONDENSER FAN MOTOR

Watts

 

RPM

 

Amps

 

 

 

 

 

2.3

 

1100 CW Opposite

 

0.15 Running

 

Shaft

 

 

 

 

 

 

 

 

 

 

 

ICE MAKER SPECIFICATIONS

 

 

 

 

 

Electrical

 

115 vac (127 vac max)

 

60 Hertz

 

 

 

 

 

Thermostat

 

Opens at 48°F (9°C)

 

Closes at 15°F ( -9°C)

 

 

 

 

Models with Orange wire close

Heater Voltage

 

165 vac

 

 

 

at 8.96°F (-12.8°C)

 

 

 

 

 

 

 

 

 

 

ICE MAKER CONNECTOR PLUG CONNECTIONS

 

 

 

 

 

Wire Number

 

Wire Color

 

Connects to:

 

 

 

 

 

1

 

Green / Yellow

 

Ground

 

 

 

 

 

2

 

Yellow

 

Water Valve

 

 

 

 

 

3

 

Black

 

Line

 

 

 

 

 

4

 

Light Blue

 

Neutral

 

 

 

 

 

SERVICE DATA SHEET

241588205

STANDARD - AUTOMATIC DEFROST TOP MOUNT FREEZER - R134a

IMPORTANT SAFETY NOTE

The information provided herein is designed to assist qualified repair personnel only. Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance.

IMPORTANT

If any green grounding wires are removed during servicing, they must be returned to their original position and properly secured.

IMPORTANT

PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.

ICE MAKER INFORMATION

Test Cycling: Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to com-

plete the cycle.

Water Fill Volume: The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 95 to 105cc (3.2 to 3.6 oz.). When a water valve is replaced, the fill volume must be checked.

NOTE

Some products come equipped with an Electronic Defrost Control. To initiate defrost, depress the fresh food light switch 5 times in 6 seconds (light bulb must be working). To terminate defrost, depress the fresh food light switch 5 times in 6 seconds.

CAUTION

All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will distort the plastic liner.

Loading...
+ 1 hidden pages