Frigidaire F30WC19EB, F30WC19EC, F30WC19EQ, F30WC19ES, F36WC19EB Installation Guide

...
0 (0)
j .," ,,/_n_#
F30WC, F36WC, & F42WC SERIES
4-WAY CONVERTIBLE RANGE HOOD
INTENDED FOR DOMESTIC COOKING ONLY
IMPORTANT
For Non-ducted (Ductfree) Installation:
a) Purchase non-ducted filter separately. b) Remove and discard damper/duct connector and louver cover
c) Follow all steps except steps inside dotted lines.
For Ducted Installation: I-F_T_o'_ all steps, including steps inside dotted lines. 1
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN- JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufac- turer. If you have questions, contact the manufacturer at
the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at ser- vice panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the service panel.
3. installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhaust- ing of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code au-
thorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any solid-state speed control de- vice.
8. To reduce the risk of fire, use only metal ductwork.
9. Use with approved cord-connection kit only.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when cooking flaming foods.
3. Clean ventilation fans frequently. Grease should not be al- lowed to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the size of the surface element.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PRE-
VENT BURNS. Ifthe flames do not go out immediately, EVACU- ATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.
4. Use an extinguisher ONLY if: A. You know you have a Class ABC extinguisher and you
already know how to operate it.
B. The fire is small and contained in the area where it started. C. The fire department is being called.
D. You can fight the fire with your back to an exit. * Based on "Kitchen Fire Safety Tips" published by NFPA.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and! or unbalanced impellers, keep drywall spray,
construction dust, etc. off power unit.
3. Your hood motor has a thermal overload which will automatically shut off the motor if it becomes overheated. The motor will restart when it cools down. If the motor continues to shut off
and restart, have the hood serviced.
4. For best capture of cooking impurities, your range hood should be mounted 18-24" above the cooking surface.
5. Please read specification label on product for further information and requirements.
INSTALLER: Leave This Manual With
the Homeowner.
HOMEOWNER: Use and Care
Information on Page 5.
TOOLS AND
MATERIALS REQUIRED
TOOLS [3 Drill, electric or ratchet drive [3 1-1/4" Spade bit
[3 Common head and phillips head screwdriver [3 Pliers
[3 Tape measure or ruler and pencil r For Ducted Installations ONLY: 1
I [3 Saber saw or drywall saw I L [3 Metal snips j
MATERIALS [3 Electrical wiring and supplies of type to comply with local
codes r [3 Roof or wall cap 1 I [3 Roof cement or caulk I L [3 Duct and duct tape j
For Installation on Kitchen Cabinets with Recessed Bottoms Only: [3 Two 1" x 2" x 12" (approximate length) wood strips (pur-
chase locally) [3 Four 1-1/4" long flat head wood screws (purchase locally)
to fasten strips to cabinet bottom
PLANNING DUCTWORK INSTALLATION
FIG. 1A
FIG. 1B
FIG. 1C
FIG. 1D
WALL CAP
WALL CAP
4" x 10" DUCT
ROOFCAP
1/4" x 10" DUCT
ADJUSTABLE ELBOW
WALL CAP
Begin planning ductwork by deciding where the duct will run between the range hood and the outside. For best performance, use the shortest possible duct run and a minimum number of
elbows. There are several choices shown - FIGS. 1A- 1E. In more complex ducting situations, a 3-1/4" rectangular ducting
range hood can be converted to a round duct by means of a transition.
FIG. IA. Ducting directly through the wall (for range hoods mounted on an exterior wall). Shown are two ways to duct through an outside wall. If a wall cap is used directly off the back of the
hood, special care must be taken to make sure that the damper in the damper/duct connector on the hood and damper in the wall cap do not interfere with each other when the hood is oper-
ating. This could result in either inadequate air delivery or back drafts. If this condition does exist, remove the hood damper flap. Sometimes when using a wall cap it is easier to duct vertically
and then use an elbow as shown in FIG. lB. FIG. lC. Ducting straight up through the roof using
3-1/4" x 10" rectangular duct. (For single story installations.) FIG. 1D. Ducting between the ceiling joists (for multi-story instal-
lations) or through the soffit space above the cabinets (where the soffit connects to an outside wall).
FIG. 1E. Straight up through the roof using 3-1/4" x 10" to 6" round duct transition and 6" round duct (for single-story installa-
tions). FIG. 1F. Straight up through the roof using 7" round duct (for
single-story installations). Requires optional damper Model Damp Kit available from your local dealer.
FIG. 1E
FIG. 1F
6"ROUND DUCT 3-1/4" x 10"
TO6" ROUND
DUCT TRANSITION
ROOF CAP
.IROOFCAP
7"ROUN_ DAMPERMoDEL
"DAMPKIT"
PREPARINGTHE RANGE HOOD FIG. 2
1. Unpack hood and check contents. You should receive: 1 - Aluminum Filter
1 - 3-1/4" x 10" Damper/Duct Connector (mounted inside of hood for shipping only) (Save screws for mounting.)
1 - 7" Round Duct Plate (mounted on top of hood) (not shown) (Save screws for mounting.)
2. Remove 7" round duct plate from top of hood. Set duct plate
aside - with mounting screws.
3. Remove wiring box cover. Under cover find:
For Ductfree Installations Only:
4. For ductfree installation, remove louver cover from front (or inside) of hood. (FIG. 3)
I Louvers on front of hood must be open and visible I
5. Remove either top or rear electrical knockout depending upon whether wiring will enter hood from wall or cabinet. (FIG. 4)
rDUCTED INSTALLATION ONLY I NOTE
Louver cover must be installed as shown in Figure 3 to
I function in ducted mode. I
'6. Remove appropriate duct knockout on hood by inserting
screwdr ver nto edge of knockout and break ng tabs hod ng
I knockout to hood. You may have to tap screwdriver with ham-
mer to break tabs. Peel knockout back with pliers. (FIG. 5)
17. Fit damper/duct connector over opening and secure inplace with black sheet metal screws. (FIG. 6) Hinge pins and damper/duct connector should be toward top
of hood for ducting through wall or toward back of hood for ducting through cabinet above hood. Seal joint between
damper/duct connector and hood with duct tape.
8. 7" round ducted discharge only: Re-install 7" round duct plate removed in Step #2 under "PREPARING THE RANGE HOOD" section. For best performance, line up the 7" round
duct plate with the 7" round opening on hood. Mount duct
plate to hood with 2 screws from duct plate and 2 screws
from 3¼"x 10" damper. Install a 7" round damper (purchase separately). Damper flap must open freely in direction of air flow (away from range hood).
for hood to function in ductfree mode.
NOTE
I
I
FIG, 3
FIG. 4
FIG. 5
DAMPE_DUCTCONNECTOR
/1\
/
J
PREPARING THE INSTALLATION LOCATION
MOUNT HOOD SO THAT Bo'rroM OF HOOD IS 18"-24"ABOVE COOKING SURFACE. TOP FRONT EDGE OF HOOD SHOULD BE FLUSH WITH FRONT OF CABINET FRAME.
IF DISTANCE BETWEEN WALL AND FRONT OF CABINET FRAME IS MORE THAN 12" THERE WILL BE A SPACE BE-
TWEEN BACK OF HOOD AND WALL. THIS IS NORMAL.
OMIT STEP 9 if range hood will be installed under cabinets with flush bottom.
9. (For installation on recessed bottom cabinets only) Attach a wood filler strip at each side of recessed area under cabi-
net. (Use two 1" x 2" strips cut to length.) If recess is more than 1" use thicker strips. Attach strips with 1-1/4" screws
about 3" from each end. See FIG. 7.
lO.Measure and mark the following (FIGS. 7 & 8):
a) Electrical line opening
r b) Duct opening 1
L i
11.Drill four pilot holes in corners of marked duct opening as shown and cut opening with saber saw or keyhole saw.
12.Use 1-1/4" drill bit to drill opening for electrical connection in wall or cabinet.
1&Hold hood up against cabinet bottom and trace keyhole slots
onto cabinet bottom of filler strips.
14.Screw the four supplied 7/8" wood screws for mounting the hood into the exact center of the narrow end of the keyhole
slots marked underneath the cabinet. Allow 3/8" of the screws to project, so the hood can be fitted into place.
NOTE
FIG. 6
FIG, 7
" f S
,__)
_ t ¢_7
_],._ CUT STRIPS TO FIT_, _
/
%
_ [O P____.EU_S;HLC!!TE_
RANGE HOOD ELECTRICAL
,/
WIRING OPENING
Loading...