Specifications

Model

CV400

CV401

CV300

 

CV301

CV200

CV201

CLKT

 

 

 

 

 

 

 

 

100 mm, 75 mm and

Size

95 mm (4 in)

75 mm (3 in)

50 mm (2 in)

50 mm (4, 3 and 2 in)

General

 

 

 

 

 

 

 

 

Voltage range

 

 

Any

 

 

Any

NEMA Environment

 

 

 

 

 

 

 

 

Type

 

 

Type 4/12 (indoor/outdoor)

 

 

Type 3/12

AutoGround™

 

 

 

Yes

 

 

Yes

ClirVu® Optic

 

 

 

Yes

 

 

Yes

Operating

 

 

 

 

 

 

 

-40 °C to

temperature

-40 °C to +232 °C (-40 ° F to +450 °F) and +260 °C (500 °F) intermittent

+232 °C (-40 ° F to +450 °F)

Ratings and testing

 

 

 

 

 

 

 

 

Arc-Tested (IEEE

 

 

 

 

 

 

 

 

C37.20.7)

 

63 kA for 30 cycles @ 60Hz at KEMA

 

50 kA for 30 cycles @ 60 Hz at KEMA

UL 50V component

 

 

 

 

 

 

 

 

recognition

 

 

 

Yes

 

 

Yes

UL 50 /NEMA Envi-

 

 

NEMA Type 4/12

 

 

 

ronmental Rating

 

 

 

 

NEMA Type 3/12

 

 

 

 

 

 

 

UL1558

 

 

 

Yes

 

 

No

CSA C22.2 No.

 

 

 

Yes

 

 

Yes

CSA Type Rating

 

 

Type 4

 

 

Type 3/12

IP rating

 

 

IP67 at TUV

 

 

IP55

Lloyds Register

 

 

Up to 11 kV marine switchgear, indoor or outdoor (offshore only)

Vibration rating

 

 

IEC60068-2-6 at TUV

 

 

IEC60068-2-6

Humidity rating

 

 

IEC60068-2-3 at TUV

 

 

IEC60068-2-3

Install

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50 mm 43.2 mm (1.7 in);

Actual mounting hole

 

 

 

 

 

 

 

75 mm 69.9 mm (2.75 in);

diameter required

115.42 mm (4.544 in)

89.89 mm (3.539 in)

61.37 mm (2.416 in)

100 mm 92 mm (3.62 in)

Greenlee Punch Kit =

742BB = 2984AV /

739BB = 1431AV /

76BB = 441AV /

50 mm 06974/04013; 75 mm

Punch / Die

2983AV

1432AV

442AV

04247/04246; 100 mm Hole Saw Only

Door Latch

Hand Turn

Security Key

Hand Turn

 

Security Key

Hand Turn

Security Key

Hand turn

Optics

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100 mm, 75 mm and

Optic insert diameter

95 mm (3.74 in)

75 mm (2.96 in)

50 mm (1.97 in)

50 mm (4, 3 and 2 in)

Warranty

 

 

Lifetime replacement against manufacturing defects

For more detailed specifications download datasheets at www.fluke.com/irwindows

Fluke Corporation

PO Box 9090, Everett, WA 98206 U.S.A.

Fluke Europe B.V.

PO Box 1186, 5602 BD

Eindhoven, The Netherlands

Modification of this document is not permitted without written permission from Fluke Corporation.

For more information call:

In the U.S.A. (800) 443-5853 or Fax (425) 446-5116

In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222

In Canada (800)-36-FLUKE or Fax (905) 890-6866

From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116

Web access: http://www.fluke.com

©2006-2013 Fluke Corporation.

Specifications subject to change without notice. Printed in U.S.A. 8/2013 3839848G_EN

COMPLIANCE without compromise SAFETY without sacrifice

YOUR RESULTS MATTER

ClirVu® Series

IR Windows

Fluke CV401, CV300, CV301, CV200, CV201 User Manual

Every time you open a panel cover, you expose yourself to

the potential dangers of arc flash.

99.9 % of all arc flash incidents occur when the panel door is opened. Eliminate that risk with ClirVu® IR windows.

Safety shouldn’t be secondary

If Fluke has learned anything in more than 65 years, it’s not to compromise quality in order to beat a competitor’s price. Asking, “How well can we make it?” versus “How cheaply can we make it?” may not win price wars, but it has established Fluke as the standard of excellence, and the preferred name in test and measurement equipment.

Compliance.

The future is clear.

“Better safe than sorry,” is becoming a modern mantra for companies who want protection from the physical and economic tragedies that can result from arc flash incidents.

If there’s ever a problem, it won’t be a question of whether or not you’ve done the minimums, but whether you’ve done as much as possible to protect your people. With Fluke IR Windows comes the confidence that when it comes to the safety of your people, you have not compromised.

Fluke ClirVu®

IR Windows

Not just a better window —a clearer view.

The solution

Don’t open the panel door.

Once a ClirVu® IR Window is installed, there’s no more need to power down or remove panels—you may never have to open the panel door again. Inspections are conducted quickly, easily, and of course, safely. Decreasing risks of arc flash may also result in lower insurance costs.

Your greatest investment is not what’s behind the panel, so when Fluke made the decision to manufacture infrared windows, our priority was to offer the ultimate protection for the electricians, engineers and inspectors who risk their lives doing their jobs.

At the same time, the quest for safety has led to numerous technological advancements resulting in faster installation and inspections. It’s safe to say, ClirVu is all you need to be both compliant and more productive at your job.

1

www.fluke.com/irwindows 2

Loading...
+ 2 hidden pages