Fluke 75, 21, 77, 23 User Manual

0 (0)

®

77/75/23/21

Series III Multimeter

Instruction Sheet

W Read First: Safety Information

Never use the meter if the meter or test leads look damaged.

Be sure the test leads and switch are in the correct position for the desired measurement.

Never measure resistance in a circuit when power is applied.

Never touch the probes to a voltage source when the test leads are plugged into the 10 A or 300 mA input jack.

Never apply more than the rated voltage between any input jack and earth ground.

Be careful when working with voltages above 60 V dc or 30 V ac rms. Such voltages pose a shock hazard.

Keep your fingers behind the finger guards on the test probes when making measurements.

WWarning

To avoid false readings, which could lead to possible electric shock or personal injury, replace the battery as soon as the battery indicator (M) appears.

Symbols

W

Y

T

Read First: Safety Information

Dangerous Voltage May Be Present

Double Insulation

Overvoltage Installation Category per IEC 1010:

CAT II

CAT III

Typical locations include; main wall outlets, local appliances, and portable equipment.

Typical locations include switches in the fixed installation and equipment for industrial use permanently connected to the fixed installation.

PN 650512 August 1997 Rev.2, 7/98

ã 1997, 1998 Fluke Corporation. All rights reserved. Printed in U.S.A.

All product names are trademarks of their respective companies

Input Jacks

Milliamp

Amp

V

600V CAT

1000V CAT

FUSED

Volts, Ohms,

Diode Test

Common

Terminal

hc1f.eps

See Specifications for overload protection.

Autorange

The meter defaults to autorange when you turn on the meter.

Manual Range

Manual ranging is available in V ac, V dc, ohms, A ac, and A dc.

MANUAL

MANUAL

RANGE RANGE

Momentary

CAT

CAT

+_

hc11f.eps

To return to autorange, press for 1 second or turn the rotary switch.

Automatic Touch Holdâ Mode

W Warning

To avoid electric shock, do not use the Touch Holdâ mode to determine if a circuit with high voltage is dead. The Touch Holdâ mode will not capture unstable or noisy readings.

The Touch Holdâ mode automatically captures and displays stable readings for all functions.

HOLD

AUTO HOLD

HOLD

HOLD

RANGE

RANGE

RANGE

Momentary

V

 

V

 

V

 

 

 

 

 

 

CAT

 

 

 

 

 

CAT

+

_

+

_

+

_

 

 

 

 

Single Beep

 

 

 

 

 

 

hc4f.eps

When the meter captures new input, it beeps and a new reading is displayed.

Note

Stray voltages can produce a new reading.

To exit the Touch Holdâ mode, press momentarily or turn the rotary switch.

Bar Graph

The bar graph shows readings relative to the full scale value of the displayed measurement range and indicates polarity.

hc15f.eps

Fluke 75, 21, 77, 23 User Manual

Standby

If the meter is on but is inactive for an hour (20 minutes in diode test), the display goes blank and displays four bar graph segments. To resume operation, turn the rotary switch or press a button.

AC and DC Voltage (K L mL)

Volts AC

Volts DC

Millivolts DC

RANGE RANGE

V V

mV

RANGE

 

CAT

 

CAT

 

CAT

 

CAT

 

CAT

 

CAT

+

_

+

_

+

_

 

 

 

 

 

hc3f.eps

Resistance (e)

Turn off the power and discharge all capacitors. An external voltage across a component will give invalid resistance readings.

RANGE

CAT

CAT

+_

hc7f.eps