Fisher & Paykel DD24DV2T, DD24DDFT User Manual

0 (0)

DOUBLE DISHDRAWERTM DISHWASHER

DD24DDFT & DD24DV2T

models

INSTALLATION GUIDE

US CA

591385 A 08.17

1SAFETY AND WARNINGS

!WARNING!

Electrical Shock Hazard

Before installing the dishwasher, remove the house fuse or open the circuit breaker. If permanently connecting the dishwasher, be sure the power is isolated and the dishwasher unplugged.

GROUNDING INSTRUCTIONS

This appliance must be grounded. In the event of a malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This appliance is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is installed and grounded in accordance with all local codes and ordinances. WARNING - Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt as to whether the appliance is properly grounded.

If the dishwasher is installed as a permanently connected appliance: GROUNDING INSTRUCTIONS - This appliance must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the appliance.

Do not modify the power supply plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified electrician. Do not use an extension cord, adapter plug or multiple outlet box.

Failure to follow this advice may result in electrical shock or death.

!WARNING!

Cut Hazard

Take care - panel edges are sharp.

Failure to use caution could result in injury or cuts.

IMPORTANT SAFETY INSTRUCTIONS

Installation of this dishwasher requires basic mechanical and electrical skills. Be sure to leave these Instructions with the Customer.

Installation must comply with your local building, electricity, and plumbing regulations. At the completion of the dishwasher installation, the Installer must perform the Final Checklist.

Remove all packaging materials supplied with the dishwasher. This dishwasher is manufactured for indoor use only.

Ensure all water connections are turned OFF. It is the responsibility of the plumber and electrician to ensure that each installation complies with all Codes and Regulations. The dishwasher MUST be installed to allow for future removal from the enclosure if service is required.

The switched power outlet must be outside the dishwasher cavity, so that it is accessible after installation.

Care should be taken when the appliance is installed or removed to reduce the likelihood of damage to the power supply cord and hoses.

If the dishwasher is to be relocated from one installation to another it must be kept upright to avoid damage from water spillage.

Make sure only new hoses are used for connection (supplied with the dishwasher). Old hoses should not be reused.

Failure to install the dishwasher correctly could invalidate any warranty or liability claims. If the product is installed in a motor vehicle, boat or similar mobile facility, you must bring the vehicle, boat or mobile facility containing the product to the service shop at your expense or pay the service technician’s travel to the location of the product.

This dishdrawer is intended for connection to the hot-water supply.

IMPORTANT!

SAVE THESE INSTRUCTIONS

The models shown in this installation guide may not be available in all markets and are subject to change at any time. For current details about model and specification availability in your country, please go to our 1 website www.fisherpaykel.com or contact your local Fisher & Paykel dealer.

2PARTS SUPPLIED

Drain hose

Drain hose

Wire clip (2)

Clamp (1)

Side mounting

Top

support (1)

joiner (1)

(for securing

(for securing

bracket kit

mounting

 

 

Drain hose joiner)

Drain hose joiner)

(A and B) (2)

brackets (2)

 

 

 

 

OPTIONAL

OPTIONAL

Phillips

Rubber washer

Moisture protection

Hexagonal

Prefinished

Edge Protector (1)

5⁄8” (16 mm)

for inlet hose (1)

tape (1)

socket for feet

toekick (1)

(If the services hole

screws (9)

(comes already

(to prevent moisture

adjustment (2)

 

is through a metal

 

fitted)

damage to cabinetry)

(long & short)

 

partition, the hole must

 

 

 

 

 

be protected with the

 

 

 

 

 

Edge Protector supplied

 

 

 

 

 

to prevent damage to the

 

 

 

 

 

power cord or hoses.)

If the Drain hoses supplied are not long enough to reach your services, you must use a Drain Hose Extension Kit P/N 525798 which will extend the drain hoses by 11’ 10” (3.6m). The kit is available from the nearest Fisher & Paykel Authorized Service Center, or Toll free 1.888.936.7872 or www.fisherpaykel.com

2

3OPTIONALLY HARD WIRING PRIOR TO INSTALLATION

3-A REMOVE THE LOWER DRAWER

To prevent kinked hoses

Either sit the drawer down on the left hand side (recommended) or rotate the drawer clockwise, resting it on its side after removal.

3

1

4

Push drawer runners back in on either side.

Sit the drawer down

2

4”

(100

mm)

 

 

 

 

 

3

Press the release tabs in on either side and push back to release drawer from runners. Lift drawer off runners.

4

Push drawer runners back in

on either side.

Rotate the drawer clockwise (max. 90o) and rest on side.

3-B REMOVE THE ACCESS COVER & REMOVE POWER

3

1 Clip

1 Clip

Access cover

1With a flat-bladed screwdriver, push in the clips and slide out the access cover.

2Unscrew the electronics module cover.

3Carefully pull out the electronics module and rest on the chassis base out of the way.

4With a screwdriver, unclip the plastic harness cover and hinge open.

5Slide the terminal block cover sideways to unlock and hinge open

to access the terminal block.

6Unscrew the Live, Neutral and Earth

wires as shown.

7Unscrew the three screws on the base as shown and remove the cord from the product.

 

2

 

Electronics

5

module

Terminal

 

Block cover

4

Remove existing

power cord

7 6

7

3

Fisher & Paykel DD24DV2T, DD24DDFT User Manual

3OPTIONALLY HARD WIRING PRIOR TO INSTALLATION

3-C TERMINATE MAINS WIRING AS SHOWN AND REPLACE MODULE AND COVERS

8 9

IMPORTANT!

Ensure the mains wires are routed UNDERNEATH all other harness wiring from the electronics module.

11

10

 

 

8

Fit a suitable cable clamp for the

 

 

 

conduit through the metal knockout.

 

12

 

Ensure wiring is routed through or

 

 

under under housing ribs.

 

 

9

Screw down the Live, Neutral and

 

 

 

Earth wires correctly.

 

 

10

Push the plastic harness cover back

 

 

 

over. It should clip back into place

 

 

11

Fold down and slide back the

 

 

 

terminal block cover.

 

 

12

Refit the electronics module back

 

14

 

into position, being careful of wiring.

13

13

Replace the screw securing the

 

 

electronics module.

 

 

 

 

 

14

Slide the access cover back,

 

 

 

ensuring the 2 clips shown are fully

locked in place.

NOTE: Use copper conductors only.

3-D REFIT THE DRAWER ONTO THE RUNNERS & CLOSE

2

Before refitting the

 

drawer, ensure the hoses

 

are not twisted and the

 

latches at the rear of

1

each drawer runner are

facing forward.

Lift or rotate counter-clockwise the drawer back onto the drawer runners on either side.

3

4

4” (100

mm)

 

Pull the release tabs forward on both sides 4” (100 mm). Ensure the tabs are fully pulled forward and click into place.

Release tab

4

4PRODUCT DIMENSIONS

Handles may vary

H

K

I

FRONT

B

E

PLAN

C

J

G

A

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROFILE

 

N

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DD24DDFT

 

DD24DV2T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRODUCT DIMENSIONS

 

 

 

 

INCHES (MM)

 

INCHES (MM)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A Overall height of product 1

 

 

 

 

34 - 36 3/8” (864-924) 2

 

34 - 36 3/8” (864-924) 2

 

 

 

 

 

B Overall width of product

 

 

 

 

23 9/16” (599)

 

23 13/16” (605)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C Overall depth of product (excl. handle)

 

 

 

 

22 9/16” (573)

 

22 3/4” (578)

 

 

 

 

 

D Depth of chassis (to back of front drawer panel)

 

 

 

 

21 3/4” (553)

 

21 3/4” (553)

 

D

 

E Depth of drawer front panel (excl. handle)

 

 

 

 

13/16” (20)

 

1” (25)

 

 

F Height of chassis 1

 

 

 

 

33 11/16” (855)

 

33 11/16” (855)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G Height of drawer front panels

 

 

 

 

30” (762)

 

30” (762)

 

 

 

 

 

H Height of upper drawer front panel

 

 

 

 

17 3/8” (442)

 

17 3/8” (442)

 

 

 

 

 

I Height of lower drawer front panel

 

 

 

 

12 1/4” (312)

 

12 1/4” (312)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J Height from top of drawer front panel to top of chassis

 

 

 

 

1/16” (2)

 

1/16” (2)

 

 

 

 

 

K Ventilation gap between drawer front panels

 

 

 

 

5/16” (8)

 

5/16” (8)

 

O

 

L Height of toekick (customisable)

 

 

 

 

2 13/16 - 5” (72-127)

 

2 13/16 - 5” (72-127)

 

 

 

 

 

M Depth from front of drawer panel to front of toekick (adjustable) 3

 

 

 

 

1 1/2 - 4” (38-102)

 

1 11/16 - 4 3/16” (43-107)

 

 

 

 

 

N Height of leveling feet (adjustable)

 

 

 

 

3/8 - 2 11/16” (9-69) 2

 

3/8 - 2 11/16” (9-69) 2

 

 

 

 

 

O Maximum extension of drawer

 

 

 

 

21 9/16” (547)

 

21 9/16” (547)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 includes 1/16” (2mm) high bracket slots 2 depending on adjustment of leveling feet

5

3 adjustable to match toekick recess on adjoining cabinetry

5CABINETRY DIMENSIONS

Q

R

Bracket slots

PLAN

CABINETRY DIMENSIONS

PInside height of cavity*

QInside width of cavity

RInside depth of cavity

SRecommended height of adjacent cabinet space

THeight of toekick space*

* depending on adjustment of leveling feet

DD24DDFT

INCHES (MM)

min. 34” (864)

23 5/8” (600)

min. 22 1/16” (560)

30” (762)

DD24DV2T

INCHES (MM)

min. 34” (864)

24” (610)

min. 22 1/16” (560)

30” (762)

3 15/16” - 6 5/16” (100-160) 3 15/16” - 6 5/16” (100-160)

S

P

T

PROFILE

Minimum clearances from adjacent cabinetry

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

min. 1/2” (13 mm)

 

 

 

 

 

 

 

 

 

 

 

min. 1/16” (2 mm)

 

 

 

 

clearance from a

 

 

 

 

 

 

 

clearance

 

 

 

 

corner cupboard

 

 

 

 

 

to adjacent

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cupboard door

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

6 CAVITY PREPARATION

COUNTERTOP

Moisture

3/8” protection (10 mm) tape must

be applied.

These marks indicate formed bracket screw locations, if securing by drawer removal.

If there is no side partition, you can construct timber bracing as something to secure into.

Services hole

Can be located either side of dishwasher, preferably at the bottom of the cavity, as shown. If adequate clearance, services hole can be made higher to clear toekick space. If hole is higher, ensure drain hose(s) are routed straight into the waste connection.

If the hole is through wood, make sure its edges are smooth and rounded.

If the hole is through metal, ensure you fit the supplied Edge Protector to prevent damage to the power cord.

IMPORTANT!

The power outlet must be located in a

cabinet adjacent to the dishwasher cavity. 110-120 VAC max. 15 A

max. 17 11⁄16” (450 mm)

ø max. 1 1/2” (38 mm)

min. 7 7⁄8” (200 mm)

Water Connection

Recommended HOT (Maximum 140°F/60°C).

Supplied hose to

suit 3⁄8” (9 mm) male compression fitting.

Water Pressure

Water softener models

Max. 1 MPa (145 psi)

Min. 0.1 MPa (14.5 psi)

Models without water softener

Max. 1 MPa (145 psi) Min. 0.03 MPa (4.3 psi)

Kosher requirements

Drains will need to be separated to satisfy kosher requirements. We suggest you confirm acceptability with your local rabbi in respect to kosher installations.

7

7 MAXIMUM DISTANCE OF HOSES & CORD FROM CHASSIS EDGE

LEFT HAND SIDE

Drain hoses - 78 1/2” (2000mm)

Inlet hose - 64 3/4” (1650mm)

Power cord (excl.plug) - 29 1/2” (750mm)

RIGHT HAND SIDE

Drain hoses - 70 1/2” (1800mm)

Inlet hose - 49” (1250mm)

Power cord (excl.plug) - 27 1/2” (700mm)

8

NOW CHOOSE WHICH INSTALLATION METHOD (A) OR (B)

IS MORE SUITABLE FOR YOUR CABINETRY...

8RECOMMENDED METHOD (A) - SECURE WITHOUT DRAWER REMOVAL (FRAMELESS CABINETRY ONLY)

8-A ATTACH SIDE MOUNTING BRACKETS

 

Clip all four side mounting brackets

 

 

into their slots using a flat-bladed

 

B

screwdriver. Ensure they’re securely

A

fitted before sliding product into cavity.

 

 

 

B

 

A

 

A

 

B

A

B

The mounting slots are in pairs, one on each side diagonally across the product. A bracket must match A slot and B bracket must match B slot.

When fitting brackets, ensure the ends are not pushed down into the chassis.

9-A PULL THROUGH HOSES & PUSH INTO THE CAVITY

optionally attach the

When fitting brackets,

two top mounting

ensure the ends are

brackets

not pushed down into

(x2)

the chassis.

 

Initially level the product

You can raise or lower the product by twisting the feet. Then take care when pushing the product into the cavity

that you do not bend the feet.

As you push product in, pull through hoses and cord, ensuring they don’t get kinked or twisted.

9

!0-A SECURE TO THE CABINETRY ON THE SIDES

!1-A OPTIONALLY SECURE TO THE CABINETRY ABOVE

1

Open the drawer halfway.

Using a flat bladed screwdriver, prise the grey rubber plug out of the trim moulding.

2

Replace the grey rubber plug back into the trim moulding and ensure the trim seal is facing forward.

3

The top mounting brackets will only

(x2) bend upwards a maximum of 10 mm.

Using a small

 

Philips screwdriver,

 

screw through the

 

trim moulding,

 

securing the side

 

mounting bracket

 

to the cabinetry.

 

Do not damage

 

the rubber

 

trimseal.

Repeat for all

 

four brackets.

!2-A AFTER SECURING, REFER TO ‘FIT THE SUPPLIED TOEKICK PANEL’ STEP

10

8ALTERNATIVE METHOD (B) - SECURE BY DRAWER REMOVAL

8-B PULL THROUGH HOSES & PUSH INTO THE CAVITY

optionally attach the

 

two top mounting

When fitting brackets,

brackets

ensure the ends are

(x2)

not pushed down into

the chassis.

Initially level the product

 

You can raise or lower the product by twisting the feet. Then take care when pushing the product into the cavity

that you do not bend the feet.

As you push product in, pull through hoses and cord, ensuring they don’t get kinked or twisted.

11

9-B REMOVE THE LOWER DRAWER

To prevent kinked hoses

Either sit the drawer down on the left hand side (recommended) or rotate the drawer clockwise, resting it on its side after removal.

1

2

4”

(100mm)

 

 

 

Press the release tabs in on either side and push back to release drawer from runners. Lift drawer off runners.

3

4

Push drawer runners back in

on either side.

Sit the drawer down

3

4

Push drawer runners back in on either side.

Rotate the drawer clockwise (max. 90o) and rest on side.

Loading...
+ 28 hidden pages